The cable features a dry construction making the installation of connectors simple and quick.. The dielectric cable meets the latest standards for UL OFNR-LS and is constructed of materi
Trang 1w w w a d c c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
ADC’s indoor/outdoor tight buffer cables are flexible and easy to install The cable features a dry construction making the installation of connectors simple and quick The dielectric cable meets the latest standards for (UL) OFNR-LS and is constructed of materials that contain no halogens and no heavy metals Cables can be installed between buildings and within buildings, eliminating the need for splicing or fanout kits.
Features:
Low smoke, zero halogen
900 µm tight buffered fibers designed for
one-pass mechanical stripping
Excellent crush, cut and abrasion resistance,
flame retardancy
Constructions available with 4 to 24 fibers
UV resistant jacket
Flexible design, easy to install
Color-coded buffered fibers
All cables tested to Telcordia and EIA/TIA
FOTP standards
Well suited for direct termination; no need
to splice at building entrance
Installs in conduits between buildings
Offers a convenient alternative to PVC
riser cables
•
•
•
•
•
•
•
•
•
•
•
Armored versions available for rodent resistance
Additional jacket colors and constructions available
Applications:
Tunnels and power plants Industrial environments Outdoors subject to rough handling
Compliances:
Telcordia GR-409-CORE, EIA/TIA FOTPs (UL) 1666, NEC OFNR
TIA/EIA 568-B IEC 332-3C (Distribution 4-12 Fibers) IEC 332-1 (Distribution 16-24 Fibers)
•
•
•
•
•
•
•
•
•
•
Trang 22
w w w a d c c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Specifications
Indoor/Outdoor Distribution Cable
LSZH Outer Jacket
900 µm Tight Buffer
E-Glass Central Strength Member Ripcord
LSZH Outer Jacket
900 µm Tight Buffer
E-Glass Central Strength Member Ripcord
Environmental Characteristics
Storage Temperature -40˚ to 70 ˚C (-40˚ to 158 ˚F)
Operating Temperature -20˚ to 70 ˚C (-4˚ to 158 ˚F)
Installation Temperature 0˚ to 70 ˚C (32˚ to 158 ˚F)
Mechanical Characteristics
Max Tensile Load N (lbf)
Short Term
Long Term
669 (150)
334 (75)
669 (150)
334 (75)
1339 (300)
669 (150)
1339 (300)
669 (150)
Min Bend Radius mm (in.)
Short Term
Long Term
118 (4.7)
590 (2.3)
122 (4.8)
610 (2.4)
157 (6.2)
307 (7.9)
168 (6.6)
840 (3.3)
Trang 33
w w w a d c c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Transmission Performance —Guaranteed Minimum Link Lengths
Gigabit Ethernet Link Length (SX/LX)
10 Gigabit Ethernet Link Length (SR/LX4) 2
Multimode
(LR/ER)
2 10 Gigabit Ethernet distance guarantees at the long wavelength are achieved via four
3.125 Gbps channels multiplexed with WWDM technology
Optical Performance
Maximum Attenuation (dB/km)
Typical Attenuation (dB/km)
Bandwidth 1
(MHz/km)
Multimode
1 Bandwidth measurements specified overfilled launch conditions (OFL)
Trang 4Website: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website
ADC Telecommunications, Inc., P.O Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice At any time, you may verify product specifications by contacting our headquarters office in Minneapolis ADC Telecommunications, Inc views its patent portfolio as an important corporate asset and vigorously enforces its patents Products or features contained herein may be covered by one or more U.S or foreign patents An Equal Opportunity Employer
105162AE 8/07 Revision © 2007 ADC Telecommunications, Inc All Rights Reserved
*Replace YYY with fiber type:
010 = Singlemode
062 = 62.5/125 µm Multimode
050 = 50/125 µm Multimode
50E = 50/125 µm Enhanced Multimode