• Dry cable core• Available in singlemode, 50µm and 62.5µm multimode and hybrid construction • Dry water block buffer tubes • All-dielectric or armored construction • Designed for duct o

Trang 1

® S tr

Fiber Optic Cable Solutions

Outside Plant Cable 196

Indoor/Outdoor Cable 198

Compact Building™ Cables 202

Breakout Cables 206

Closet Distributions LCF Optical™ Cables 208

Furcation Tubing 214

Trang 2

• Dry cable core

• Available in singlemode, 50µm and 62.5µm multimode and hybrid construction

• Dry water block buffer tubes

• All-dielectric or armored construction

• Designed for duct or lashed aerial installations

• Excellent crush and impact resistance

• High pulling force

• Easy to install

• UV resistant outer sheath

• All cables tested to EIA/TIA FOTP standards

• Available with rodent-resistant armoring

• Wide operating temperature range:

-40° to +70°C (-40° to +158°F)

• Excellent above and below ground reliability

• Low attenuation for optimum signal reliability

PE Outer Jacket3.0mm (0.12in) Dry Water Block Buffer TubeAramid Yarn Strength Members

250µm UV Colored Optical FiberCentral Strength Member (Dielectric)Water Swellable Tape

Rip Cord

PE Outer Jacket3.0mm (0.12in) Dry Water Block Buffer TubeAramid Yarn Strength Members

250µm UV Colored Optical FiberCentral Strength MemberWater Swellable TapePlastic Coated Corrugated SteelRip Cord

Loose Tube

Armored Loose Tube

Ordering information follows on the next page

Trang 3

Outside Plant Cable

Loose Tube, Polyethylene Jacketed Cables

11.712.714.716.818.918.921.913.4 14.316.418.420.520.523.516.2 18.39.7 10.3

0.460.500.580.660.740.740.860.53 0.560.640.720.800.800.920.64 0.720.38 0.40

94107141176216228315

179 199247299353365474

351 444

91 151

637295118145153211

120 133166200237245318

235 298

61 101

QXXXLTSDNAYYY

QXXXLTSDARYYY

QXXXLTDDARYYY

QXXXLTSUNIYYY QXXXLTSUARYYY

* Replace XXX with fiber count

Replace YYY with fiber type:

010 = Singlemode

062 = 62.5/125µm multimode

62E = 62.5/125µm Enhanced multimode

50E = 50/125µm multimode

50U = 50/125µm Ultra multimode laser optimized to 300m

5U5 = 50/125µm Ultra multimode laser optimized to 550m

Trang 4

Dry Loose Tube Cables:

Riser and Plenum Listed OFNR/FT-4 and OFNP/FT-6 c(ETL)us

Features

• Can be placed anywhere in the network, inter/intrabuilding backbones in duct, aerial, or riser applications

• Dry cable core and dry buffer tubes provide effective water blocking without the need for traditional gel filler

• Bypass transition points from outdoor to indoor to reduce installation times

• Available in singlemode, 50/125µm, 62.5µm multimodes, and hybrid configurations

• Excellent flame retardancy

• Flexible design for easy installation

• Color-coded buffer tubes and fibers

• Wide operating temperature: -40° to +75°C (-40° to +167°F)

Indoor/Outdoor Dry Loose Tube (up to 12 fibers)

250µm UV Colored Optical Fiber3.0mm Thermoplastic Tube Dry Water Blocking Buffer TubeStrength Member

UV Flame-Resistant Outer Jacket

250µm UV Colored Optical Fiber3.0mm Thermoplastic Tube Dry Water Blocking Buffer Tube

Dielectric Central Strength MemberStrength Member

UV Flame-Resistant Outer JacketIndoor/Outdoor Dry Loose Tube (up to 144 fibers)

Ordering information follows on the next page

Trang 5

Dry Loose Tube Cables:

Riser and Plenum Listed OFNR/FT-4 and OFNP/FT-6 c(ETL)us

18–728496108120132144

6.6 10.411.512.413.314.315.216.217.218.26.6

11.712.613.614.615.716.617.6

0.26 0.410.450.490.520.560.600.640.680.720.26

0.460.500.540.570.620.660.70

48 113110156171206229261295337

48

130138163192223257294

32 7774105115138154175198226

32

8793110129150172197

QXXXDLTIORYYY

QXXXDLTIOPYYY

* Replace XXX with fiber count

Replace YYY with fiber type:

010 = Singlemode

062 = 62.5/125µm multimode

62E = 62.5/125µm Enhanced multimode

50E = 50/125µm multimode

50U = 50/125µm Ultra multimode laser optimized to 300m

5U5 = 50/125µm Ultra multimode laser optimized to 550m

Trang 6

• Low smoke, zero halogen (LSZH)

• 900µm tight buffered fibers designed for one-pass mechanical stripping

• Excellent crush, cut and abrasion resistance, flame retardancy

• Constructions available with four to 24 fibers

• UV resistant jacket

• Flexible design, easy to install

• Color-coded buffered fibers

• All cables tested to Telcordia and EIA/TIA FOTP standards

• Well-suited for direct termination; no need

to splice at building entrance

• Installs in conduits between buildings

• Eliminates need for indoor cable transition point

• Tight buffer fibers eliminate need for fan out kits

• Armored versions available for rodent resistance

Optical Performance

Ordering information follows on the next page

Trang 7

50U = 50/125µm Ultra multimode laser optimized to 300m

5U5 = 50/125µm Ultra multimode laser optimized to 550m

Contact ADC for additional jacket colors and constructions

via four 3.125Gbps channels multiplexed with WWDM technology

Multimode

(LR/ER)

Trang 8

OFNP/FT-6 c(UL)us Plenum Cable

• Easy-to-strip outer jacket

• Features TrueNet technology to improve cable performance (up to 24 fibers)

Ordering information follows on the next page

Trang 9

OFNP/FT-6 c(UL)us Plenum Cable

Strength Member

72-Fiber Cable

OFNP Outer Jacket 12-Fiber Subunit Aramid Yarn Strength Members 900µm Tight Buffered Fibers Rip Cord

Dielectric Central Strength Member

* Replace YYY with fiber type:

via four 3.125Gbps channels multiplexed with WWDM technology

Multimode

(LR/ER)

Trang 10

OFNR/FT-4 c(UL)us Riser Cable

Ordering information follows on the next page

Trang 11

OFNR/FT-4 c(UL)us Riser Cable

12-Fiber Cable

OFNR Outer Jacket900µm Tight Buffered Fiber Aramid Yarn Strength MembersDielectric Central

Dielectric Central Strength Member

Transmission Performance—

Guaranteed Minimum Link Lengths

via four 3.125Gbps channels multiplexed with WWDM technology

Multimode

(LR/ER)

* Replace YYY with fiber type:

Trang 12

• 900µm tight buffered fibers designed for one-pass mechanical stripping

• Constructions available with four to 24 fibers

• Available with 1.6mm, 2.0mm, 2.4mm, and 2.9mm subunits

• All-dielectric construction includes aramid yarn tensile strength members

• All cables tested to Telcordia and EIA/TIA FOTP standards

• Ideal for applications requiring direct connections to terminal equipment

• Individual subunits allow for easy routing

of fibers to termination points while maintaining fiber protection

• Good for increased robustness

Dielectric Central Strength MemberPlenum, 6-Fiber Cable

Riser, 6-Fiber Cable

Flame Retardant OFNP Outer JacketRip Cord

SubunitAramid Yarn Strength Members

Dielectric Central Strength MemberFlame Retardant Core WrapFlame Retardant OFNR Outer JacketRip Cord

SubunitAramid Yarn Strength Members

Ordering information follows on the next page

Trang 13

010 = Singlemode

062 = 62.5/125µm multimode

62E = 62.5/125µm Enhanced multimode

50E = 50/125µm multimode

50U = 50/125µm Ultra multimode laser optimized to 300m

5U5 = 50/125µm Ultra multimode laser optimized to 550m

OFNR/FT-4 c(UL)us Riser and OFNP/FT-6 c(UL)us Plenum Cables

Contact ADC for additional jacket colors and constructions

Guaranteed Minimum Link Lengths

via four 3.125Gbps channels multiplexed with WWDM technology

Multimode

(LR/ER)

Trang 14

• Evenly distributed aramid yarn strength member simplifies terminations

• Eliminates the need to furcate for hybrid patch cords, thus reducing labor costs

• Versatile buffer size can be configured for specific small-form-factor connectors

• Reduced shrink back minimizes attenuation and connector separation

Applications

• Communications closet patch cord assemblies

• Workstation outlet patch cord assemblies

• Hybrid patch cords: small-form-factor connectors to legacy connectors

Compliances

Heavy metal/lead-free cable independently verified to comply with current worldwide environmental demands

• Restriction of the Use of Hazardous Substances (RoHS) (2002/95/EC)

• State of California Safe Drinking and Toxic Enforcement Act of 1986 (Proposition 65)

• ISO/IEC 11801, IEC 60794-2, Optical Fiber Cables–Part 2

• Telcordia GR-409-CORE, EIA/TIA FOTPs

• TIA/EIA 568-B

• (UL) 910, NEC OFNP, FT-6

Performance information follows on the next page

and CAP-046A (ICP-AES)

and CAP-046A (ICP-AES)

and CAP-046A (ICP-AES)

and CAP-046A (ICP-AES)

chromium value through calibration

of the UV-V15 spectrophotometer

Trang 15

Heavy Metal/Lead-Free c(UL)us OFNP/FT-6 Plenum Listed Cable

Closet Distribution LCF Optical Cable™

Optical Performance

Transmission Performance—Guaranteed Minimum Link Lengths

via four 3.125Gbps channels multiplexed with WWDM technology

Simplex

Aramid Yarn Strength MembersLead-Free Outer Jacket900µm Plenum Lead-Free BufferZip Cord

Aramid Yarn Strength MembersLead-Free Outer Jacket900µm Plenum PVC Buffer

Duplex

Lead-Free Outer Jacket900µm Plenum Lead-Free BufferOptical Fiber

Aramid Yarn Strength Members

Ordering information follows on the next page

Multimode

(LR/ER)

Trang 16

Heavy Metal/Lead-Free c(UL)us OFNP/FT-6 Plenum Listed Cable

Trang 17

Closet Distribution LCF Optical Cable™

Heavy Metal/Lead-Free c(UL)us OFNR/FT-4 Riser Listed Cable

Features

• Evenly distributed aramid yarn strength member simplifies terminations

• Eliminates the need to furcate for hybrid patch cords, thus reducing labor costs

• Versatile buffer size can be configured for specific small-form-factor connectors

• Reduced shrink back minimizes attenuation and connector separation

Applications

• Communications closet patch cord assemblies

• Workstation outlet patch cord assemblies

• Hybrid patch cords: small-form-factor connectors to legacy connectors

Compliances

• Heavy metal/lead-free cable independently verified to comply with current worldwide

environmental demands

• Restriction of the Use of Hazardous Substances (RoHS) (2002/95/EC)

• State of California Safe Drinking and Toxic Enforcement Act of 1986 (Proposition 65)

• ISO/IEC 11801, IEC 60794-2, Optical Fiber Cables–Part 2

• Telcordia GR-409-CORE, EIA/TIA FOTPs

• TIA/EIA 568-B

• (UL) 1666, NEC OFNR, FT-4

Performance information follows on the next page

and CAP-046A (ICP-AES)

and CAP-046A (ICP-AES)

and CAP-046A (ICP-AES)

and CAP-046A (ICP-AES)

chromium value through calibration

of the UV-V15 spectrophotometer

Trang 18

Transmission Performance—Guaranteed Minimum Link Lengths

via four 3.125Gbps channels multiplexed with WWDM technology

OFNR Outer Jacket900µm PVC BufferAramid Yarn Strength MembersZip Cord

OFNR Outer Jacket900µm PVC BufferAramid Yarn Strength Members

OFNR Outer Jacket900µm PVC BufferOptical FiberAramid Yarn Strength Members

Ordering information follows on the next page

Multimode

(LR/ER)

Trang 19

Closet Distribution LCF Optical Cable™

Heavy Metal/Lead-Free c(UL)us OFNR/FT-4 Riser Listed Cable

Trang 20

• Variety of sizes to fit specific applications

• Craft-friendly color scheme for easy identification

• Choice of materials to suit specific requirements

• Minimal shrinkage materials are available

• Non out-gassing versions available

• Made with RoHS compliant materials

• (UL) 94 materials available

Furcation Tubing Materials

• Patching active devices

• Terminating loose tube cables

• Fortifying distribution cables for patch cable applications

• Buffering bare fibers in coupler and splitter applications

• Specialty fiber assemblies

Lead-Free Outer JacketInner Tube

Aramid Yarn Strength MembersPull String

Ordering information follows on the next page

Trang 21

for extreme temperatures and chemical resistance

for low shrink requirements; material meets (UL) 94 V-0

inner tube, designed for 900µm buffers

inner tubing; for specialty fibers

for LC connector applications