1 - General note MC during construction stage Construction hoarding Site Preparation Site Office and Office Facility Site Security & Management team Traffic, road maintenance and transpo
Trang 1Issuance date: 30-Oct-2017
Revision: 0A SUMMARY
Section No 1 - General note
(MC) during construction stage
Construction hoarding Site Preparation Site Office and Office Facility Site Security & Management team Traffic, road maintenance and transportation
HSE Construction method Bonds and insurance Authorities Approval Additional works
Concrete works Reinforcement works
Formworks Additional works
owner including roofing works, the landscape works
Masonry works Waterproofing works Tiling, hardener, stone, timber works Skimcoat and Emulsion painting works
Ceiling / False ceiling works
Roofing Doors and Windows works
Metal works Kitchen Cabinets and Mirror cabinets
Signage works Loose furniture for public areas, security room, Building Management
Office Additional works
Lift works Plumbing works MVAC works Fire Fighting and Prevention works
Electrical works Additional works
including landscape Leveling grading works
Road, pavement, out side corridor floor works
Gate & fence works Stormwater drainage system works
Landscape works Swimming pool, balance tank, pool deck, water fountain playground,
children's playround works Canopy main entrance works Loose furniture for pool deck, changing room, out door gym
equipment and children playround
MEP infrastructure works
PACKAGE: SUPERSTRUCTURE SCOPE OF WORKS
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 2Issuance date: 30-Oct-2017
Revision: 0A SUMMARY
PACKAGE: SUPERSTRUCTURE SCOPE OF WORKS BAO MINH EZLAND APARTMENT District 9, HCMC
River clearance, cleaning and other
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 3SECTION NO 1 - GENERAL NOTE
A
The Bill of Quantities are to be read in conjunction with all other sections contained in these documents
which shall be construed as being complementary to one another The Quantities given are for
information only and shall be checked and verified by the Contractors No Claim shall be allowed for
errors or omissions int his Bill of quantities.
B
Allow against the items or in the prices for everything contained in these Bill of Quantities which has a
monetary value Items which are not priced or have dashes or other like marks inserted in the cash
columns will be deemed to be of no value or included elsewhere in the tender and no Payment
whatsoever will be included in Interim Payment in the event of no amounts being inserted Lump sums are
not to be given when unit rates are applicable.
C
All rates, amounts and / or percentage values in these Bills shall be entered up to two decimal places gor
United States Dollars and no decimal places for Vietnamese Dong In cases where more than two
decimal places are entered, only the first two decimals will be used.
D The rates and prices entered in the Bill shall be deemed to be the full inclusive value of the work covered
by the several items including the following, unless expressly stated otherwise;
(i) Labour and costs in connection therewith.
(ii) The supply of materials, equipment, plant, goods storage and cost in connection therewith including
waste and delivery to Site.
(iii) All construction equipment plant and costs in connection therewith.
(iv) Fixing, erecting and installing or placing of materials, equipment, plant and goods in position including
all necessary temporary works and materials.
(v) Movement of piling frames into position and about the Site, any necessary excavation or filling
required to place the frames, raising or lowering the frames and any staging, barges or the like required to
support the frames.
(vi) Driving/boring through and/or breaking up any soil material, sandstone, shale, rock or boulders and
the like at any depth.
(vii) Removal of underground obstructions together and all work in connection therewith.
(viii) Removing all surplus spoil due to piling works from Site.
(ix) Replacing incorrectly piles, damaged piles and piles which fail under tests.
(x) Safety equipment and measures such as oxygen tanks, breathing apparatus, etc for workers operating
below the surface.
(xi) The cost of any additional work due to eccentricity of piles and/or damaged or displaced piles.
(xii) Idling time for all equipment, plant and labour for whatever reason, except on particular instruction
from the Construction Manager
(xiii) Sampling and testing materials, equipment, plant and goods, testing, workmanship, providing,
storing, packing and transporting samples to and from the place of testing
(xiv) General obligations, liabilities and risks involved in the execution of the Works set forth or reasonably
implied in the tender documents including procurement of all necessary insurances.
(xv) Establishment charges, overheads and profit.
(xvi) Payment of all taxes, fees, charges as maybe imposed on the Contractor or due to the Works.
(xvii) Items against which no price or rate is entered shall be deemed to be covered by the other rates and
prices in the Bill of Quantities.
(xviii) All rates and prices entered here inbelow shall be deemed to be in Vietnam Dongs.
E
The Contractor is deemed to have read all other related documents, Specflcations and Bills of Quantities,
etc and in particular to have studied the tender drawings to be fully aware of the full extent of the Works
described under each Direct Contractor's Works and the corresponding interface with the Contractor's
own Work.
PACKAGE: SUPERSTRUCTURE
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 4SECTION NO 2 - CONSTRUCTION PRELIMINARIES
Employer Contractor
1.1
Hoarding, Entrance gates, Billboard for main façade building
(follow axis A)
Main Contractor will be handed over by Substrucutre Contractor
x
1.2 Fence for the rest of the sides surrounding the Site Main Contractor will be handed over by Substrucutre Contractor x
1.3
Fence and hoarding during construction time Maintain and repair it as necessary to keep this condition during the
1.4
Supply maintain and removal Sign board with name of
Employerr, CM, PM, QS, Architect and M&E Consultant
Maintain and repair it as necessary to keep this condition during the
Include connection with Service providers (EVN) installation, maintenance, consumption, remove but not including temporary Transformer for construction, Allowance for stand-by generator will use during the construction period, as long as full back up peractivities on site, lighting for night shift
x
Temporary Earthing system including supply, install, remove,…fee during construction time
2.2 Temporary water for construction time
Include connection with Service providers (SAWACO) installation, maintenance, consumption, remove as long as full back up peractivities
2.3 The water drainage system
Include connection, installation, maintenance, removeas well as for construction and testing & commissioning
The water drainage system must be separate from the construction drainage system
And Comply with DTM accessment & DTM approval for construction stage and EZLAND Method Statement Guidelines
x
2.4 Telephone - internet system
Include connection with Service providers (Viettel, )
- Number of telephone lines: 04 line, including connecting
- LAN system and fiber internet with wifi, including connecting Following TCVN/codes/norms/Manufacturer requirements Communication charges
x
Site Arrangement
Safety training, rebar workshop, rebar fabrication yard, formwork workshop area, stores for materials
All must ensure the sufficient area for use
Finishing base made of concrete with 100 mm thick Following TCVN/codes/norms/Manufacturer requirements
x
Canteen If canteen is installed, it shall be located outside the building, with tight
control of cleanliness and and approved by the authorities x
2.8 Guard post Location anear Entrance gate, included: table, chair, light, fan,… x
2.9 Washing bay
Main Contractor will be handed over by Substrucutre Contractor, maintain and repair it as necessary to keep this condition during the construction period
x
2.10 Temporary accommodation for workers Not allowed inside the Project and no any worker is allowed to stay on
2.11 All other work that the contractor deems necessary to serve
3.1 The Employer Office
* Provide and maintain temporary site Office, for the Employer staff and Consultant, with private room for PD/PM with surficient working spaces for 20 staff minimum
Meeting room with whiteboard for 30 people Temporary toilet
Sample room, store rooms
* Provide the private motorbike parking with roof
* Daily cleaning
x
3.2 Facilities for Employer Office
Provide and maintain:
- A3, A4 photocopier with functioning of color printing and color scanning, printing via wifi
- A3 and A4 paper
- Telephone: 4 lines, full internet
- Shelf, cabinets tables, chairs which is sufficient for working and meeting of 20 poeple
- Walkie-Talkie: 6 sets
- Electric water heater including drink water
x
4 Security & Management team Following TCVN/codes/norms/Manufacturer requirements
BAO MINH EZLAND APARTMENT District 9, HCMC
PACKAGE: SUPERSTRUCTURE
Remarks
* To be provided for temporary toilets, cleaning, etc
And Comply with DTM accessment & DTM approval for construction stage and EZLAND Method Statement Guidelines
2.7
2.1 Temporary power for construction time, including power
network
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 5SECTION NO 2 - CONSTRUCTION PRELIMINARIES
Employer Contractor
PACKAGE: SUPERSTRUCTURE
Remarks
4.2 Management team
Allowance for site management staff mobilization and demobilization (including expat If any) including travelling, accommodation, out-of-pocket expenses
x
5 Traffic, road maintenance and transportation
5.1 Internal Traffic and maintenance
Main Contractor can use internal road from substructure package and can propose additional road to make sure site transportation as required
Temporary road need to be strong and clean during construction stage Maintain and repair during the construction period
x
5.2 External traffic and maintenance
Control external traffic for trucks coming to site Periodic check the status of external road and repair immediately in during construction stage
x
6 HSE
6.1 Hygiene
* Time to time cleaning all site including roads surrounding site
* Clean all dump truck before going out of site
* Provide sufficient number of WC for workers
* Organize regular pest control including mosquito, termite
x
6.2 Safety
Including but not limited
* Safety staff
* First Aid
* Safety instruction signage at all locations can be dangerous
* Safety plan, evacuation plan, tools PPE for contractor
* Safety walk way
* Tools PPE for Employer staff and Consultant: 20 sets (included safety helmets, safety boots, reflective jackets)
* Tools PPE for guests: 20 sets (included safety helmets, safety boots, reflective jackets)
* Periodic inspect/test the machines, tower crane, hoist, etc
x
6.3 Environment
* Control and limit dust continously
* Provide temporary septic tank before discharging
* The water drainage system must be separate from the construction drainage system
* And Comply with DTM accessment & DTM approval for construction stage and EZLAND Method Statement Guidelines
x
6.4 Rubbish cleaning * Provide center point for rubbish stores, discharge daily
* Time to time cleaning the site out of water, rubbish x 6.5 Site fire fighiting system Provision of site security services during the Contract period x
All construction methods will be submitted for approval prior to commence works on site
7.1 General
7.1.1 Works protections
Works need to be protected prior to carry our next works
Hardener slab:
- Surface protection: recommended to cover, protect the surface to avoid staining, discoloration, or mechanical impact
All exposed sleeves / cables:
- Proper boxes & cap to cover and secure to floor
x
7.1.2 Durable and long term use
Works are designed and constructed well to make sure they are durable for long term use
The nature of works should be designed based on location eg outdoor works and indoor works to make sure all works are suitable for respective areas,
x
7.1.3 Survey & mornitoring Main Contractor to propose report of observation of subsidence and
inclination for the building and neighbor buildings x 7.1.4 Scaffolding system and surrounding scaffolding The scaffolding must be comply to safety requirement and adapted to
7.1.5 All necessary works independent checking of construction
method
Allowance for all necessary works independent checking of
7.1.6 Submission of materials' sample for approval including
resubmision of alternatives and lor substitution
Allowance for any cost in connection herewith for submission of materials' sample for approval including resubmision of alternatives and lor substitution
x
7.1.7 Preparing and submission all as buili drawings Including but not limited x
7.21 Excavation * Provide adapted construction method to make sure there is no any
inclinations and displacements of compressed piles x
7.22 Formwork for slab & Beam
* To ensure the surface of areas that are not covered by false ceiling, are flat for direct putty and painting eg living room, bed room
* Drawings and inspection sheet must be submitted to Consultant/PU for prior to permission to use
* Inspection of formwork is mandatory for each demoulding
* Use aluminum formwork for typical floors and plywood for other floors
x
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 6SECTION NO 2 - CONSTRUCTION PRELIMINARIES
Employer Contractor
BAO MINH EZLAND APARTMENT District 9, HCMC
PACKAGE: SUPERSTRUCTURE
Remarks
7.23 Formwork for shear wall, columns and staircase,…
* Use formwork based on standardized sizes and meets construction standards
* Drawings and inspection sheet must be submitted to Consultant for prior to permission to use
* Inspection of formwork is mandatory for each demoulding
x
7.24 Concrete
* The slab must be poured out of the hot weather and rainy weather
* All tests are required
* Curing concrete is required to prevent hairline crack, using plastic / fabric sheet cover and chemical where required,
x
7.25 Reinforcement Following TCVN/codes/norms/Manufacturer requirements x
7.3 Architecture works
7.31 Bricklaying
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 3.1
x
7.3.2 Plastering
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 3.2
x
7.3.3 Skim coat
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 3.3
x
7.3.4 Screeding/ rendering
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 3.4
x
7.3.5 Tiling
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 3.5
x
7.3.6 Emulsion Paint
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 3.6
x
7.3.7 Aluminum doors & windows
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 3.7
x
7.3.8 Wooden laminate flooring
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 3.8
x
7.3.9 Cement / concrete block Following TCVN/codes/norms/Manufacturer requirements x
7.3.10 False ceiling Following TCVN/codes/norms/Manufacturer requirements x
7.3.11 Wooden doors Following TCVN/codes/norms/Manufacturer requirements x
7.3.12 Steel doors Following TCVN/codes/norms/Manufacturer requirements x
7.4 MEP works
7.4.1 Quality requirements for MEP works
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 4.1
x
7.4.2 Electrical wiring system
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 4.2
x
7.4.3 Floor trap
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 4.3
x
7.4.4 Drilling and fixing
Following TCVN/codes/norms/Manufacturer requirements and
"Reference Buiding Method Statement Guidelines" Ref: EZLAND
-BM-2016 - A0 Item 4.4
x
7.5 Metal Works
7.5.1 Installation of anchor bolt, metal works, metal accesories in
wet/outdoor areas Following TCVN/codes/norms/Manufacturer requirements x
7.5.2
Installation of metal accesories in dry/indoor areas such as
Hardware instalation and accessories doors stoppers,locks,
handles, hinges,
Following TCVN/codes/norms/Manufacturer requirements x
Contractor is encouraged to use tower crane #1 which is being used for Substructure package
In case that foundation of crane #1 does not meet Contractor's requirement, Contractor to propose new one to ensure schedule
x
Include: foundation,installation and erection, operation, dismantling and demobilization of tower cranes including licensed driver, banksman and maintenance, foundation and piling, embedded anchor bolts, mast jacking up, bracing, material landing platforms for cranes, power and fuel used for operation
x
Safety inspection cost and approval for use x
As per Method statement by Contractor to make sure safety and construction schedule
Include: foundation,installation and erection, operation, dismantling and demobilization of hoits including licensed driver, banksman and maintenance, foundation and piling, embedded anchor bolts, mast jacking up, bracing, material landing platforms for cranes, power and fuel used for operation
x 7.6.1
7.6.2
Tower cranes # 1, #2
Hoits
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 7SECTION NO 2 - CONSTRUCTION PRELIMINARIES
Employer Contractor
PACKAGE: SUPERSTRUCTURE
Remarks
Safety inspection cost and approval for use x
7.6.3 Equipment and tools Including but not limited: Mobilisation & Demobilization to other
10 Authority Approval
Allowance for obtaining from Authorities all notices,necessary application, licenses or permits for all other matters during Construction time
x
11 On the acceptance for operatuon of project construction
upon its complettion
To estimate cost for testing and commissioning, handover, connect including but not limit MEP systems as Fire Fighting, connect to public transportation, electric, plumbing, garbage, exhausted air,
x
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 8PACKAGE: SUPERSTRUCTURE
1 Concrete, Steel reinforcement Following TCVN/codes/norms/Manufacturer requirements
1.1
Slab, beam Concrete B30- Holcim
Steel reinforcement (SD 390) - Hoa phat/ Mien Nam / Pomina
1.2
Roof slab, beam, tum floor Waterprofing Concrete B30- Holcim
Steel reinforcement (SD 390) - Hoa phat/ Mien Nam / Pomina
1.3
Blade shear walls Concrete B45 (ground floor to 11th floor), B40 (upper floors),
-Holcim Steel reinforcement (SD 390) - Hoa phat/ Mien Nam / Pomina Vinakyoei or or equivalent
x
1.4
Lift Core walls Concrete B45 (ground floor to 11th floor), B40 (upper floors),
-Holcim Steel reinforcement (SD 390) - Hoa phat/ Mien Nam / Pomina Vinakyoei or or equivalent
x
1.5
Staircase * The steps will be casted in concrete, no solid brick steps
Concrete B30- Holcim Steel reinforcement (SD 390) - Hoa phat/ Mien Nam / Pomina Vinakyoei or or equivalent
x
1.6
Steel reinforcement (SD 390) - Hoa phat/ Mien Nam / Pomina
1.7
Parapet wall on roof Concrete B30- Holcim
Steel reinforcement (SD 390) - Hoa phat/ Mien Nam / Pomina
2 Formwork
Following TCVN/codes/norms/Manufacturer requirements '* Use formwork based on standardized sizes and meets construction standards
* Drawings and inspection sheet must be submitted to Consultant for prior to permission to use
* Inspection of formwork is mandatory for each demouldin
x
SCOPE OF WORKS
Scope of
Remarks Employer's Requirements
SECTION NO 3 - STRUCTURE WORKS
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 9Employer Contractor
1 Masonry works
1.1
Burnt clay Brick works * 200mm thickness burnt brick wall all facades/envelops of building
* Link to concrete wall by tie bar
* Laying bricks must comply with the manufacturer's requirements: the thickness of mortar joints, for laying a tolerance of 4mm on 2 meters
* 1 solid brick line for each 5 hollow brick lines
* No holes of hollow brick facing out the facade,
* solid brick 5 layer for bottom of WC / bathroom wall, , wall all facades, wall for the steel door, aluminum door
* Strengthen concrete beam for every wall which higher than 3m, 80x80x190 - 4 Hollow Clay Brick/ 40x80x190 - 2 Hollow Clay Brick Mac 75
*Wc wall use burnt clay brick Unit rate including Lintel & Stiffener refer to architecture design & structure drawing
x
1.2
Non-burnt blocks * Use for all internal wall (100mm & 200mm thk where applicable),
* Link to concrete wall by tie bar
* Laying bricks must comply with the manufacturer's requirements: the thickness of mortar joints, for laying a tolerance of 3mm on 2 meters (aluminium ruler)
Unit rate including Lintel & Stiffener refer to architecture design & structure drawing,
x
1.3
Plastering to brick wall
* Warterprofing mortar for external side
* Warterprofing mortar for internal wall Wc
* Normal mortar for internal side
* The application of the cement must be by via a layer of scratch coat The dosage should be perfectly quantified by dosing and mechanic mixing
* Wire mesh to prevent crack at corner of wall, surround openings, along MEP conduit, along the joint btw 2 different materials
* Strip lines / joints on facade where applicable
x
1.4
Plastering to non-burnt blocks * Use mortar as stated in specification of non burnt brick
* Plastering must comply with the manufacturer's requirements: the thickness for laying and the flatnesse tolerance
* Wire mesh to prevent crack at corner of wall, surround openings, along MEP conduit, along the joint btw 2 different materials
x
1.5 Concrete louver blocks for façade (hollow type) Refer to architecture design x
2.1
STP, Septic tank Standard waterproofing product
Waterproofing by waterproofing bitimen menbrane layer for internal wall and bottom, top slab
x 2.2 Lift Standard waterproofing product
Waterproofing by waterproofing bitimen menbrane layer for internal wall x 2.3
Domestic water tank, fire tank Standard waterproofing product
Waterproofing by bush cement - based waterproofing layer for internal wall and bottom, top slab
x
2.4
Yard, Balcony, Loggia, aircon ledge, Wc Standard waterproofing product
Waterproofing by bush cement - based waterproofing layer with skirting 300mm- refer architecture drawing
x Including water proofing for open floor 2.5
Terrace garden Standard waterproofing product
* Cementitious or Bitumen membrane with trees, root resistant, with skirting 300mm- refer architecture drawing
* Hairline crack resistant
x
2.6
Roof, tum floor Standard waterproofing product
* Cementitious or Bitumen membrane with skirting 300mm- refer architecture drawing
* Hairline crack resistant
x
3 Tilings, hardener, stone, timber works
3.1
Staircase including padded rooms , steps Hardener- Sikafloor Chapdur Grey (Sika) or equivalent, , including skirting
Hardener direct on concrete steps, cutting the anti-slip line at the corner of
3.2
Parking area, ramp, Hardener direct on concrete floor, , including skirting
Sikafloor Chapdur Grey (Sika) or equivalent
*Ramp including non-slip joint
x
3.3
Domestic water tank, fire tank * Ceramic tile
* water resistant grouting (pointing) x 3.4 GF lobby rooms *Homogenous tiles 600mm x 600mm* Water resistant seals (pointing) , with 70mm in height skirting x
3.5
GF, 1F, 2F, 3F corridors & all typical corridors
Including water meter rooms, electricity meter rooms,
* Homogenous tiles 600mm x 600mm , with 70mm in height skirting
* Water resistant grouting (pointing)
x 3.6 Lift frame GF Granite stone,hairline stainless steel x
3.7 Lift frame 1F, 2F, 3F, Typical floors (jamb and lintel) Homogenousgranit tiles, only surrounding lift doors x
3.8 Community rooms, children playround room, Gym room, manager room,security room with 70mm height skirting Homogenous tiles 600mm x 600mm, ncl Screeding x
3.9 Apartment - Living room, kitchen area, small bedrooms, including door-sill Homogenous tiles 600mm x 600mm, with 70mm height skirting ncl.Screeding, i x
3.10 Apartment - Master Bedrooms Laminate timber, with 70mm height skirting ncl Screeding x
Apartment - Wc floor, other area, including door-sill * Anti-slip homogenous tiles 300mm x 300mm , ncl screeding
* Water resistant seals (pointing) x Apartment - Bathroom floor for shower area * Anti-slip homogenous tiles 300mm x 300mm , ncl screeding
* Water resistant seals (pointing) x 3.12 Wc wall of Apartment and other area * Homogenous tiles 300mm x 600mm , ncl screeding
* Water resistant seals (pointing) x 3.13 Apartment - Yard, balcony, loggia, aircon ledges, including door-sill Homogenous tiles 300mm x 600mm, with 70mm height skirting ncl.Screeding x
3.14 Rubbish stores floor * Ceramic tiles 300mm x 300mm x
3.15
Garden 11F Bazan stone
Concrete grass block Finish wall by washed stone x 3.16 Door mats in carpet at entrances the carpet tile door mats at GF lobbies x
3.17 Painting line for intrernal parking Epoxy paintFollowing TCVN/codes/manufacturer x
3.11
SECTION NO 4 - ARCHITECTURAL WORKS
Scope of
Remarks
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART
P03 TEN DOC SOW REV A
Trang 10Employer Contractor
PACKAGE: SUPERSTRUCTURE
SECTION NO 4 - ARCHITECTURAL WORKS
Scope of
Remarks
3.18 Ceramic tile backsplash to kitchen of apartment *Finish by tiles* Water resistant seals (pointing) x
3.19 Ceramic tiling to roof of 3F (F8) Ceramic tile
3.20 Other area Refer to architecture design x
4 Putty and Emulsion painting works
4.1 External wall on façade outdoor emulsion paints, special façade, water resistant, washable x
4.2 Finishing layer by spray concrete glue on the wall of façade GF By spray concrete glue
Following TCVN/codes/manufacturer x 4.3
Parkings, technical rooms, corridors, lobby, community rooms, etc Indoor emulsion paints, The areas which are exposed to dirty, the paint has
to be adapted for the intense dirty (washable paint mat, or similar)
*Note: Shear wall of parking area use outdoor emulsion paints x 4.4 Apartment - Living room, bedrooms, kitchen area Indoor low VOC emulsion paints x
4.5
Apartment - Bathroom ceiling and kitchen above the counter kitchen indoor moisture resistant low VOC emulsion paints
All WC and have the access panel with sufficient size for maintenance x 4.6
Apartment - Yard, balcony, loggia, aircon ledges, exter, outdoor emulsion paints
x
5 Ceiling/False ceiling works
5.1
Concealed gypsum ceiling, thickness 9mm 9 mm thick gypsum board incl shadow line
Standard gypsum board by Gyproc or equivalent Frame system Vinh tuong or equivalent
x
5.2
Exposed gypsum ceiling, thickness 9 mm 9mm thickness gypsum board, size 600x600mm
Standard gypsum board by Gyproc or equivalent Frame system Vinh tuong or equivalent
x
5.3
Apartment - WC 9mm thickness moisture resistant gypsum board
Standard gypsum board by Gyproc or equivalent Frame system Vinh tuong or equivalent
x
5.4
Apartment - bulk head, ME pile system * 9mm thickness gypsum board to hide copper pipes for aircon
Standard gypsum board by Gyproc or equivalent Frame system Vinh tuong or equivalent
x 5.5 Bare soffit concrete slab & beam No plastering x
6 Roofing
6.1
Roof Heat tile- U 200x200x75mm
Crushed concrete-mesh steel, makes area slope thickness layer around
7.1
Apartment - entrance door MDF door with melamine surface, fireproof
Hardwares are in Germany brands like ABUS, WUERTH, HAFELE or equivalent
Note: Door lock with 3 modes: key lock, number lock, card
x
7.2
Apartment - bedrooms door MDF door, 900mm x 2200mm
With stopper, door locks in Germany brands like ABUS, WUERTH, HAFELE or equivalent
Other hardwares are standard equipments
x
7.3
Apartment - bathroom door Moisture resistant MDF door, 800mm x 2200mm
With stopper, door locks in Germany brands like ABUS, WUERTH, HAFELE or equivalent x
7.4
General Aluminum doors and windows Size of aluminum doors and windows as architectural design
8.36mm laminated tempered glass thickness minimum Hardware are in Germany brands like ABUS, WUERTH, HAFELE or equivalent
x
7.5
Glass partition, aluminum frame Size of Glass partition as architectural design
8.36mm laminated tempered glass thickness minimum Hardware are in Germany brands like ABUS, WUERTH, HAFELE or equivalent
x
7.6
Shower screen * Fixed tempered glass panel for shower screen excluding glass door,
height= 2000mm
* Only master bathroom
x 7.7
Fire rated doors Staircase doors, technical room doors, doors for the GF lift lobby
x 7.8
Where fire rated door is not required such as riser for water meter,
electricity meter, etc
MDF door with veneer surface, wood frame, fireproof Hardwares are in Germany brands like ABUS, WUERTH, HAFELE or equivalent
x 7.9 Roller shutter doors * For ramp of parking x
7.10 Aluminium louvers and louver Following TCVN/codes/manufacturer x
8.1 FF Staircase, and Community rooms 60mm diameter steel handrail x
8.2 Loggia, private loggia Steel plate 70mm x 5mm for handrail of all loggia, yard, private balcony (
8.3 Out side corridor floor Steel plate 70mm x 5mm for handrail of all corridor ( H= 1.3m) x
8.4 Steel Staircase for aparment Steel staircase with steel handrail x
8.5 Steel Staircase in shophouse Steel staircase with steel handrail x
8.6
Ramp and handicaped ramp * 60mm diameter steel handrail
* Follow TCVN/codes/norms and any specific requirement from Authorities
on Handicaped
x 8.7 Stainless steel for lift, tanks Following TCVN/codes/manufacturer x
8.8 V-protection for all columns/shear wall in parking area Galv V steel, x
8.9 Steel grating for ram wide 300mm, (Included angle steel V50x50x5) Following TCVN/codes/manufacturer x
8.10 Steel grid for parking area Following TCVN/codes/manufacturer x
8.11 Steel frame lavabo include granit for changing room Following TCVN/codes/manufacturer x
8.12 Partition laminat for Wc for changing room Following TCVN/codes/manufacturer x
Other
8.13
Canopy at GF walkway, drop-off and roof garden 11F * Steel frame, glass roof, including accessories
* Canopy at GF is designed to protect the pedestrial walking from the entrance to GF lobbies
* All canopies are designed for the long term used and durable in outdoor condition,
* The width of canopy is wider than width of walkway below
x
8.14 Speed reducer of parking Following TCVN/codes/manufacturer x
8.15 Car stop Following TCVN/codes/manufacturer x
8.16 Door mats in carpet at entrances Following TCVN/codes/manufacturer x
171030
BM ART
P03 TEN RFI
001
App 02-171030
BM ART