bundling along column – inside Cabinet using 300I ties... Huawei bundling of discrete cables near connectors on backplane– inside Cabinet Bundle the discrete cables near the connectors

Trang 1

Course No.: QA-CI-003

Compiled by: Engineering Center Service Management Dept.Issue Date: 2004-11-15

Technical Specifications for Cable Bundling Of Exchange

Trang 2

Huawei

Objective

To best utilize the cable ties attached to the

delivery to bundle the subscriber and trunk

cables of an exchange

Application:

Exchange and (for reference of) other products

Note:

The figures and the spaces between cable ties

in this course are for reference only.

Trang 3

Table of Contents

1 Cable Tie

2 Technical Specifications for Cable Tie Mounting

3 Technical Specifications for Cable Bundling

4 Subscriber Cable

5 Single-core Trunk

6 8-core Trunk

7 Power Cable

8 Power Bus Cable

9 Alarm Indicator Cable

10 Emergency Serial Port Cable

11 Power and Signal Cable of Fan

Trang 5

Techinical Specifications for Cable Tie Mounting

1 Mount the cable ties in even spaces and at an appropriate degree of tightness.

2 Cut off the end of each cable tie in a way that no sharp

Trang 6

Huawei

Technical Specifications for Cable Bundling

1 Arrange the cables in a bundle closely, straight, and

neatly

2 The cables in a trough may not be bundled Arrange them

neatly They cannot cross each other They cannot overflow the trough

3 Route the signal cables separately from the power cables.

4 Bend a cable, if required, evenly and softly

5 The total thickness of the cables under a floor cannot

exceed 3/4 of the floor height.

6 The cables can cross within one meter after they exit the cabinet.

7 Do not damage the insulation layer of the cables when

bundling them.

8 Do not join cables.

Trang 7

Subscriber Cable–inside Cabinet

subrack section of a column and fix them through

baffle rings

lower) using 100M ties.

Trang 8

Huawei

bundling on beam–inside Cabinet

using 150I ties

Trang 9

bundling along column – inside Cabinet

using 300I ties

Trang 10

Huawei

bundling of discrete cables near connectors on

backplane– inside Cabinet

Bundle the discrete cables near the connectors on each backplane at three points (upper, medium and lower) using 100M ties.

Trang 11

Subscriber Cable–outside Cabinet (between

Rack and MDF)

A Bundle the cables using 150I and 300I ties.

B Tighten every four cables into one bundle using 150I ties Connect them serially into a square

C Mount cable ties in an even space of 400 mm

(reference).

D Mount 300I ties onto the bending points and to fix the cables on the cabling rack.

Trang 12

Huawei

cabling on cabling rack–outside Cabinet

Trang 13

cabling ladder–outside Cabinet

Trang 14

Huawei

in raised floor–outside Cabinet

Trang 15

in raised floor–outside Cabinet

Trang 16

Huawei

Subscriber Cable–in MDF

A Bundle the cables using 300I and 100M ties.

B Tighten every four cables into one bundle using 300I ties Connect them serially and fix them on a column in the MDF.

C Mount cable ties in an even space of 150 mm

(reference) or according to the actual situations of the

MDF.

D Bundle the stripped discrete cables using 100M ties.

E Wrap the stripped sections using tapes

Trang 17

MDF -discrete cables

Bundle the stripped discrete cables using 100M ties

Trang 18

Huawei

MDF -Keep a certain margin 、 stripped sections

Keep a certain margin , Wrap the stripped sections using tape s.

Trang 19

MDF - bundling along columnBundle the cables using 300I ties.

Trang 20

Huawei Single-core Trunk–inside Cabinet

beam to the column on either side.

subrack section of a column and fix them through baffle rings

backplane using 100M ties.

Trang 21

near connectors on backplane – inside Cabinet

Bundle the cables using 100M ties.

Trang 22

Huawei

bundling along column – inside Cabinet

Bundle the cables using 300I ties.

Trang 23

inside Cabinet

Trang 24

Huawei

Single-core Trunk–outside Cabinet

(between Rack and DDF)

A Bundle the cables using 300I ties.

kinked

C Mount cable ties in an even space of 400 mm

(reference).

Trang 25

Single-core Trunk–outside Cabinet

(between Rack and DDF)

Trang 26

B Mount cable ties in an even space of 150 mm

(reference) or according to the actual situations

of the DDF.

C Bundle the cables near the connectors in the

Trang 27

DDF - near the connectors

Bundle the cables near the connectors in the DDF using 100M ties.

Trang 28

Huawei

DDF - near the connectors

Trang 29

DDF -along a column

Bundle the cables on along a column using 300I ties.

Trang 30

Huawei

8-core Trunk–inside Cabinet

and those along a column using 300I ties.

B Fix the subscriber cables of each subrack

along the beam to the column on either side.

C Mount three evenly spaced cable ties along

each subrack section of a column and fix them

through baffle rings

each backplane using 100M ties.

Trang 31

near connectors on backplane – inside Cabinet

Bundle the cables using 100M

ties.

Trang 32

Huawei

on a beam and along a column – Inside Cabinet

Trang 34

Huawei

8-core Trunk–in DDF

A Tighten every four cables into one bundle

using 300I ties Connect them serially into a

square and fix them in the DDF.

B Mount cable ties in an even space of 150 mm (reference) or according to the actual situations

of the DDF.

C Bundle the cables near the connectors in the DDF using 100M ties.

D Similar to the bundling of the single-core

trunk cables in the DDF

Trang 35

8-core Trunk–in DDF

Trang 36

Huawei

Power Cable

A Bundle the cables using 300I ties.

B Mount cable ties in an even space of 400 mm Tighten every four cables into one bundle

Trang 37

Power Cable -inside PDF

Trang 38

Huawei

Power Cable -inside PDF

Trang 39

Power Cable -outside Cabinet

Trang 40

Huawei

Power Cable -outside Cabinet

Trang 41

Power Bus Cable ( 95 mm2)

B Mount cable ties in an even space of 500

mm.

Trang 42

Huawei

Power Bus Cable ( 95 mm2)

Trang 43

Alarm Indicator Cable(1)

Keep the cables away from the heat dissipation hole in cabinet top.

A The row and column indicator control cables include a row indicator signal cable, column indicator signal cable, and row indicator cascade cable They drive the row and column

indicators on top of the cabinet.

B A row indicator signal cable and a column indicator signal cable share the same structure They have a 4PIN connector at one end and six UT soldering flakes at the other Fix the three soldering flakes on the three black cables to one side of the

three row and column indicators Fix the other three soldering flakes on the red, yellow, and green cables to the other side of the red, yellow, and green row and column indicators.

Trang 44

Huawei

Alarm Indicator Cable(2)

C For C841AMD (widely used in the previous

cabinets) insert the row indicator in J8 and the

column indicator in J9 in the AMD in the power

distribution box J6 and J7 are connected using the

row indicator cascade cable.

D For CB01AMD (used in the later assembled

cabinets) insert the row indicator in J6 and the

column indicator in J7 in the power distribution

box J4 and J5 are connected using the row

indicator cascade cable The row indicator cascade

cable has a 4PIN connector at either end.

Trang 45

Alarm Indicator Cable

Keep the cables away from the heat dissipation hole in cabinet top.

Trang 46

Huawei Emergency Serial Port Cable

The emergency serial ports refer to the serial data

paths throughout the entire AM/CM and SPM system

They have connection with all subracks except CKM

They are applicable for status data report of PWS,

alarm data report of AMD, and data report and

equipment maintenance of other boards in emergency

cases The entire emergency serial port system

consists of the serial port cables in various lengths

and the connected communication nodes The cables

inside a cabinet have already been installed before the

delivery The cables between cabinets need be

installed on the site There are the following two

categories of serial port cables:

Common emergency serial port communication

cable

Trang 47

Emergency Serial Port Cable

Common emergency serial port communication cable

1 All common emergency serial port communication

cables have a 4PIN connector at either end They connect

the nodes in AM/CM and SPM, including the CB01AMD in

the power distribution box and the backplanes of the

subracks.

2 There are two serial ports in the upper right (seen from

the back) of the backplane of each subrack that requires

emergency serial connection Connect the two ports in

parallel All of the ports can be connected with one serial

bus.

3 JT1 and JT2 are the serial ports in a backplane J12 and

J13 are the serial ports in AMD.

4 There are five types of emergency serial port

communication cable according to the length: 0.4-m cable, 0.8-cable, 1.2-m cable, 2.5-m cable and 4-m cable.

Trang 48

Huawei Emergency Serial Port Cable

Emergency serial port communication cable of BAM

1 An emergency serial port communication cable of

BAM connects the serial port in AMD in the BAM with

the emergency serial port in the basic cabinet.

2 An emergency serial port communication cable

has a 4PIN connector at either end Insert one end in

the serial port J12 in CB01AMD in the main control

subrack, and the other end in the serial port J12 (or

J13) in CB01AMD in the BAM.

Trang 49

Power and Signal Cable of Fan

The power and signal cable of fan supplies working

power for the fans and reporting the status signals of

the fans to the monitor unit It has a blue power

connector, a black power connector, and a fan signal

connector The power connectors are inserted in a

busbar The fan signal connector is inserted in J2 in

CB01AMD(or J1.7 in C841AMD) in the power

distribution box They have been inserted before the

delivery Pay attention to the power connector polarity

when changing the connectors on the site.

Trang 50

B The cables of an alarm box include a signal cable and a

Trang 51

Alarm Box

D The power cable supplies –48V power for the alarm box.

E The DIP switches S1 and S3 are used for setting the working mode The two RS232 ports P1 and P2 serve the serial

.

Trang 52

Huawei

Clock Cable

A The clock cables provide 8K and 2M reference clock

sources for the subracks.

B The clock cables are routed from the CKM subrack to

the subracks that require the reference clock sources.

C A clock cable is a four-pair twisted cable Its connectors are: 2  5PIN + 2  2  5PIN.

Trang 53

Network Cable Terminal

A The terminal system of AM/CM is a distributed and

hierarchical Server/Client architecture The Server side consists of the BAM Server and Switch There is a WS on the side of a Client.

B Tighten the screws on the connector of a load cable.

Trang 54

Huawei

Network Cable

Trang 55

Network Cable

Trang 56

Huawei

Tail Fiber

A Protect the tail fibers outside the cabinet in tubes.

B Tail fiber coiling diameter  8 cm

Trang 57

tail fibers - excess tail fibers

A coil of excess tail fibers shall be greater than 8cm in

diameter Fix it on a beam or tail fiber frame.

Trang 58

Huawei

tail fibers -on backplane

Bundle the tail fibers using 100M ties.

Trang 59

tail fibers -on backplane

Trang 61

61

Trang 62

Huawei

Trang 63

63

Trang 64

Huawei

Thanks

Ngày đăng: 28/06/2017, 15:15

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN