Command output in this release might vary from command output in previous releases.White papers and briefs v IBM Systems Director ftp://ftp.software.ibm.com/common/ssi/sa/wh/n/xbw03006us

Trang 4

Before using this information and the product it supports, read the information in “Notices” on page 281.

© Copyright IBM Corporation 1999, 2011.

US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract

Trang 5

About this publication vii

Conventions and terminology vii

Publications and related information vii

Web resources x

How to send your comments xi

Chapter 1 Hardware platform events 1

IBM BladeCenter and System x platform-specific events 18

CIM events 18

MPA events 70

IBM Power platform-specific events 125

Computer System 125

Ethernet Port 136

Fan 137

Fibre Channel Port 138

Memory 139

Optical Drive 141

PCI Device 142

Physical Volume 143

Processor 144

USB Port 145

IBM System Storage platform-specific events 146

Battery 147

Disk Drive 147

RAID Controller 148

Storage Pool 148

Storage Subsystem 148

Storage Volume 149

Switch 149

PET events 149

PET > Environmental 150

PET > Firmware 152

PET > Hardware 154

PET > System 156

SNMP events 157

ibmSystemMIB 158

ibmSystemRaid 170

Chapter 2 IBM Systems Director tasks, software, and operating system events 201

Director > Director Agent 201

Director > Director Agent > Process Monitors 201

Director > Director Agent > Resource Monitors 203

Director > Scheduler 204

Director > Scheduler > Job 204

Director > Scheduler > System 205

IBM Systems Director Program events 207

Agent events 207

Automation Event Actions events 207

Security 208

Status events 210

System Configuration events 210

Updates 212

Virtualization events 215

Director > Correlation > Common Agent events 223

Operating System 224

Trang 6

CIM > Windows NT Event Log 225

CIM > Windows NT Service 225

CIM > Windows Registry 225

Windows Event Log events 225

Chapter 3 Sources of events in an IBM Systems Director environment 227

CIM event sources 227

The MPA event source in IBM Director, version 5.10 and later 227

PET event source 228

ibmSystemMIB event source 228

Chapter 4 Extended details and variable-binding information 229

Extended details for CIM events 229

Extended details for HMC CIM events 229

Extended details for the Director > Director Agent events 229

Extended details for the IBM Systems Director Program > Security events 230

Extended details for MPA events 230

Extended details for PET events 230

Variable-binding information for IBM Systems Director SNMP events 231

Chapter 5 CIM indications in IBM Systems Director 233

IBM_MgmtHwLogStatus CIM indication 233

IBMx_AutomaticServerRestartEvent CIM indication 234

IBMPSG_ChassisEvent CIM indication 234

IBMPSG_DASDBackplaneEvent CIM indication 235

IBMPSG_ErrorLogEvent CIM indication 235

IBMPSG_FanEvent CIM indication 236

IBMPSG_GenericFanEvent CIM indication 236

IBMPSG_GenericVoltageEvent CIM indication 237

IBMPSG_LeaseExpirationEvent CIM indication 237

IBMPSG_MemoryPFEvent CIM indication 238

IBMPSG_NetworkAdapterFailedEvent CIM indication 238

IBMPSG_NetworkAdapterOfflineEvent CIM indication 239

IBMPSG_NetworkAdapterOnlineEvent CIM indication 239

IBMPSG_PFAEvent CIM indication 240

IBMPSG_PowerSupplyEvent CIM indication 240

IBMPSG_ProcessorPFEvent CIM indication 241

IBMPSG_RedundantNetworkAdapterEvent CIM indication 241

IBMPSG_RedundantNetworkAdapterSwitchbackEvent CIM indication 242

IBMPSG_RedundantNetworkAdapterSwitchoverEvent CIM indication 242

IBMPSG_RemoteLoginEvent CIM indication 243

IBMPSG_SMARTEvent CIM indication 243

IBMPSG_SPPowerSupplyEvent CIM indication 243

IBMPSG_StorageEvent CIM indication 244

Adjusting disk-space event threshold values on Linux systems 245

Adjusting disk-space event threshold values on Windows systems 245

IBMPSG_TemperatureEvent CIM indication 246

IBMPSG_VoltageEvent CIM indication 246

IBMPSG_WarrantyExpirationEvent CIM indication 247

ADPT_ArrayFlashCopyComplete CIM indication 247

ADPT_ArrayFlashCopyDetected CIM indication 247

ADPT_ArrayFlashCopyFail CIM indication 248

ADPT_ArrayRebuildComplete CIM indication 248

ADPT_ArrayRebuildDetected CIM indication 248

ADPT_ArrayRebuildFail CIM indication 249

ADPT_ArraySyncComplete CIM indication 249

ADPT_ArraySyncDetected CIM indication 249

ADPT_ArraySyncFail CIM indication 250

ADPT_CompactionComplete CIM indication 250

ADPT_CompactionDetected CIM indication 250

Trang 7

ADPT_CompactionFail CIM indication 251

ADPT_CompressionComplete CIM indication 251

ADPT_CompressionDetected CIM indication 251

ADPT_CompressionFail CIM indication 252

ADPT_ConfigFail CIM indication 252

ADPT_ControllerAdded CIM indication 252

ADPT_ControllerBadStripes CIM indication 253

ADPT_ControllerBatteryOvertemp CIM indication 253

ADPT_ControllerBatteryTempNormal CIM indication 253

ADPT_ControllerFail CIM indication 254

ADPT_ControllerFailover CIM indication 254

ADPT_ControllerMismatchedVersions CIM indication 254

ADPT_ControllerReplaced CIM indication 255

ADPT_CopyBackComplete CIM indication 255

ADPT_CopyBackDetected CIM indication 255

ADPT_CopyBackFail CIM indication 256

ADPT_DeadBattery CIM indication 256

ADPT_DeadBatteryCache CIM indication 256

ADPT_DecompressionComplete CIM indication 257

ADPT_DecompressionDetected CIM indication 257

ADPT_DecompressionFail CIM indication 257

ADPT_DefunctDrive CIM indication 258

ADPT_DefunctDriveFRU CIM indication 258

ADPT_DefunctReplaced CIM indication 258

ADPT_DriveAdded CIM indication 259

ADPT_DriveClearComplete CIM indication 259

ADPT_DriveClearDetected CIM indication 259

ADPT_DriveClearFail CIM indication 260

ADPT_DriveRemoved CIM indication 260

ADPT_DriveVerifyComplete CIM indication 260

ADPT_DriveVerifyDetected CIM indication 261

ADPT_DriveVerifyFail CIM indication 261

ADPT_EnclosureFail CIM indication 261

ADPT_EnclosureFanFail CIM indication 262

ADPT_EnclosureFanInstalled CIM indication 262

ADPT_EnclosureFanOK CIM indication 262

ADPT_EnclosureFanRemoved CIM indication 263

ADPT_EnclosureOK CIM indication 263

ADPT_EnclosurePowerSupplyFail CIM indication 263

ADPT_EnclosurePowerSupplyInstalled CIM indication 264

ADPT_EnclosurePowerSupplyOK CIM indication 264

ADPT_EnclosurePowerSupplyRemoved CIM indication 264

ADPT_EnclosureTempFail CIM indication 265

ADPT_EnclosureTempOK CIM indication 265

ADPT_ExpansionComplete CIM indication 265

ADPT_ExpansionDetected CIM indication 266

ADPT_ExpansionFail CIM indication 266

ADPT_FlashCopyComplete CIM indication 266

ADPT_FlashCopyDetected CIM indication 266

ADPT_FlashCopyFail CIM indication 267

ADPT_InitComplete CIM indication 267

ADPT_InitDetected CIM indication 267

ADPT_InitFail CIM indication 267

ADPT_LogicalDriveAdded CIM indication 268

ADPT_LogicalDriveBlocked CIM indication 268

ADPT_LogicalDriveCritical CIM indication 268

ADPT_LogicalDriveCriticalPeriodic CIM indication 269

ADPT_LogicalDriveOffLine CIM indication 269

ADPT_LogicalDriveOK CIM indication 269

ADPT_LogicalDriveRemoved CIM indication 270

ADPT_LogicalDriveUnblocked CIM indication 270

Trang 8

ADPT_MigrationComplete CIM indication 270

ADPT_MigrationDetected CIM indication 271

ADPT_MigrationFail CIM indication 271

ADPT_NoControllers CIM indication 271

ADPT_PFADrive CIM indication 272

ADPT_PFADriveFRU CIM indication 272

ADPT_PollingFail CIM indication 272

ADPT_RebuildComplete CIM indication 273

ADPT_RebuildDetected CIM indication 273

ADPT_RebuildFail CIM indication 273

ADPT_SyncComplete CIM indication 274

ADPT_SyncDetected CIM indication 274

ADPT_SyncFail CIM indication 274

ADPT_TestEvent CIM indication 275

ADPT_UnsupportedDrive CIM indication 275

LSI_RAID_HS_Fail CIM indication 275

LSI_RAID_LD_Degraded CIM indication 276

LSI_RAID_LD_Offline CIM indication 276

LSI_RAID_LD_Optimal CIM indication 276

LSI_RAID_PD_Fail CIM indication 277

LSI_RAID_PD_HS CIM indication 277

LSI_RAID_PD_PartOf_LD_Add CIM indication 277

LSI_RAID_PD_PartOf_LD_Fail CIM indication 278

LSI_RAID_RbldComplete CIM indication 278

LSI_RAID_RbldFail CIM indication 278

LSI_RAID_RbldStart CIM indication 279

LSI_RAID_SMART_Error CIM indication 279

Notices 281

Trademarks 282

Index 285

Trang 9

About this publication

This publication provides reference information for commands available in IBM®Systems Director These commands fall into two broad categories:

v Commands used to perform IBM Systems Director tasks These commands are implemented using the IBM Systems Director command-line interface, IBM Systems Director.

v Commands used to configure, start, or stop IBM Systems Director and database These commands are entered directly on the command line when the action should be performed.

Conventions and terminology

These notices are designed to highlight key information:

Note: These notices provide important tips, guidance, or advice.

Important: These notices provide information or advice that might help you avoid inconvenient or difficult situations.

Attention: These notices indicate possible damage to programs, devices, or data.

An attention notice appears before the instruction or situation in which damage can occur.

Publications and related information

You can view the same content in the IBM Systems Director Information Center as PDF documents To view a PDF file, you need Adobe Acrobat Reader, which can

be downloaded for free from the Adobe Web site at http://get.adobe.com/reader/.

Information centers and topic collections

v IBM Systems http://publib.boulder.ibm.com/eserver/

View the IBM Systems information center landing page, which provides integrated information for multiple IBM Systems products.

v IBM Systems Director publib.boulder.ibm.com/infocenter/director/pubs/index.jsp Updated periodically, the IBM Systems Director topic collection contains the most up-to-date documentation available for IBM Systems Director.

v IBM Systems Director plug-ins http://publib.boulder.ibm.com/infocenter/director/pubs/topic/extensions/ extensionparent.html

View the IBM Systems information center for information about how to install and use plug-ins that extend the functionality of IBM Systems Director.

v IBM Systems Director Upward Integration Modules (UIMs) publib.boulder.ibm.com/infocenter/systems/topic/uims/fqs0_main.html Read the IBM Systems Director Upward Integration Modules (UIM) topic collection to learn about how to install and use upward integration modules and

Trang 10

management packs that enable non-IBM workgroup and enterprise-management products to interpret and display data that is provided by Common Agent and Platform Agent.

v IBM Systems Director API Licensing http://www.ibm.com/vrm/4api1 View the license information regarding use of IBM Systems Director APIs and their associated documentation Fill out the form to request API access After your information is reviewed, you will be contacted with additional information regarding access to and use of the APIs.

Publications

Release Notes® 6.3

Provides an easy reference to planning, install and troubleshooting information for IBM Systems Director.

IBM Systems Director Planning Guide

Provides planning information, including hardware requirements for running IBM Systems Director components, supported IBM Systems Director hardware, operating systems, databases, and workgroup and enterprise systems-management software.

PDF files for installing IBM Systems Director Server

Provides detailed instructions to prepare for, install, and configure the IBM Systems Director Server.

PDF files for installing IBM Systems Director agents

Provides detailed instructions to prepare for and install IBM Systems Director agents on your managed systems, as well as, prepare for agentless managed systems.

PDF files for upgrading and migrating IBM Systems Director Server

Provides detailed instructions to upgrade and migrate the IBM Systems Director Server.

PDF files for upgrading and migrating IBM Systems Director agents

Provides detailed instructions to upgrade and migrate IBM Systems Director agents.

Systems Management Guide

Provides detailed instructions for using the Web interface and managing systems and resources in your environment.

Hardware Command Line User's Guide

Provides information about installing and using the Hardware Command

Trang 11

Line (formerly known as the IBM Management Processor Command-Line Interface) Command output in this release might vary from command output in previous releases.

White papers and briefs

v IBM Systems Director

ftp://ftp.software.ibm.com/common/ssi/sa/wh/n/xbw03006usen/

XBW03006USEN.PDF

This paper provides a detailed overview of the changes in IBM Systems Director V6.1, including the new Web interface, security features, operating system agents, integrated plug-ins and additional plug-ins that can be separately

v Performance Tuning and Scaling Guide for IBM Systems Director 6.2

Hardware requirements for running IBM Systems Director Server

Provides information about how to plan, implement, configure, and use an IBM Systems Director Server to manage a large configuration with optimal

performance The Performance Tuning and Scaling Guide also contains

information about the following topics:

– Running IBM Systems Director plug-ins, such as IBM Systems Director Active Energy Manager®and IBM Scalable Systems Manager

– Integration with Tivoli® products

– Implementing high availability

IBM Redbooks® publications

Implementing IBM Systems Director 6.1

Tip: Be sure to note the date of publication and to determine the version of IBM Systems Director software to which the Redbooks publication refers.

Further information

Also see the following resources for further information about IBM Systems

Director:

v For alerts, discussions, news, parts and product information, and specific

troubleshooting workarounds for IBM Systems Director, see the Support & downloads Web site at http://www.ibm.com/support/us/en/.

Tip: To locate the information that you need, enter “IBM Systems Director” in

the Search field and click Search You can then narrow your results by document

type or product category, or use additional search terms.

Trang 12

v For white papers, technotes, tips, and other documents related to IBM Systems Director, see the Techdocs Web site at http://w3.ibm.com/support/techdocs/ atsmastr.nsf/Web/Techdocs.

Tip: To locate the information that you need, either select the categories that you want to search or select UNMARKED to search all categories Then enter “IBM

Systems Director” in the for: field and click Search.

v For solutions to all types of situations that other customers have encountered, see the IBM Systems Director customer forum at www.ibm.com/

v IBM Systems Director Downloads www.ibm.com/systems/management/director/downloads/

View the IBM Systems Director Downloads Web site on ibm.com which provides links to download code IBM Systems Director, IBM Systems Director plug-ins, and IBM Systems Director upward integration modules.

v IBM Systems Director Documentation and Resources www.ibm.com/systems/management/director/resources/

View the IBM Systems Director Documentation and Resources Web site on ibm.com which provides links to product documentation, redbooks, redpapers, white papers, and learning modules related to IBM Systems Director, IBM Systems Director plug-ins, and IBM Systems Director upward integration modules.

v IBM Systems Director Upward Integration www.ibm.com/systems/software/director/downloads/integration.html View the IBM Systems Director Upward Integration Web site on ibm.com which provides more information about IBM Systems Director upward integration modules created by IBM and other companies IBM Systems Director UIMs enable third-party workgroup and enterprise systems-management products to interpret and display data that is provided by IBM Systems Director Platform Agent managed system.

v IBM Systems Director Best Practices Wiki www.ibm.com/developerworks/wikis/display/WikiPtype/

IBM+Systems+Director+Best+Practices+Wiki View updated documentation and best practices for IBM Systems Director on various systems.

v IBM Servers www.ibm.com/servers/

View the IBM Servers Web site to learn about IBM Systems server and storage products.

Trang 13

v IBM ServerProven www.ibm.com/servers/eserver/serverproven/compat/us/

View the IBM ServerProven Web site to learn about hardware compatibility of IBM System x® and BladeCenter®systems with IBM applications and

middleware, including IBM Systems Director.

Forums

v IBM Systems Director www.ibm.com/developerworks/forums/forum.jspa?forumID=759 View the IBM Systems Director forum Web site on ibm.com to discuss product-related issues pertaining to IBM Systems Director, IBM Systems Director UIMs, and IBM Systems Director extensions This Web site includes a link for obtaining the forum using a Rich Site Summary (RSS) feed.

v IBM Systems Director SDK www.ibm.com/developerworks/forums/forum.jspa?forumID=1852&start=0 View the IBM Systems Director SDK forum Web site to discuss issues pertaining

to the IBM Systems Director Software Development Kit (SDK) This Web site includes a link for obtaining the forum using a Rich Site Summary (RSS) feed.

v IBM Systems www.ibm.com/developerworks/forums/dw_esforums.jsp View the IBM Systems forums Web site on ibm.com to learn about various forums that are available to discuss technology-related and product-related issues pertaining to IBM Systems hardware and software products This Web site includes a link for obtaining the forum using a Rich Site Summary (RSS) feed.

How to send your comments

Your feedback is important in helping to provide the most accurate and highest quality information.

If you have any comments about this book or any other IBM Systems Director publication, go to the IBM Systems Director information center Web site at publib.boulder.ibm.com/infocenter/director/pubs/index.jsp There you will find the feedback page where you can enter and submit comments.

Trang 15

Chapter 1 Hardware platform events

IBM Systems Director introduces a new set of event types that categorize all possible events by the hardware or devices in your systems-management environment.

v For a hardware events severity-level name and number cross reference, see Table 1.

v For events that can be generated by multiple hardware platforms, including IBM BladeCenter and System x systems, see Table 2.

v For events that are specific to IBM Power®systems, see “ IBM Power platform-specific events.”

v For events that are specific to IBM System Storage®, see “IBM System Storage platform-specific events.”

Use the following table to map event severity-level names to numbers.

Table 1 Severity level name-number cross reference

Severity level name Severity number

Using your Web browser Find in page feature, use the following table to look up

events by their IBM Director 5.20 name The link provided displays the version 5.20 event documentation that still applies to the new version 6.1 event.

Table 2 Hardware-platform events cross reference

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > Service Event Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Resolution

CIM > System > Service Event Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Warning

CIM > System > Service Event Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Minor

CIM > System > Service Event Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Critical

CIM > System > Service Event Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Fatal

Trang 16

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > Temperature Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Resolution

CIM > System > Temperature Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Minor

CIM > System > Temperature Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Critical

CIM > System > Voltage Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Resolution

CIM > System > Voltage Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Minor

CIM > System > Voltage Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Operational Condition > Critical

CIM > System > Life Cycle Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Life Cycle > Virtual server has been created.CIM > System > Life Cycle Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Life Cycle > Virtual server has been deleted.CIM > System > Life Cycle Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Life Cycle > Host has been added

CIM > System > Life Cycle Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Life Cycle > Host has been deleted

CIM > System > Power State Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Power State > Virtual server has been started.CIM > System > Power State Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Power State > Virtual server has been shut down.CIM > System > Power State Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Power State > Host has been powered on.CIM > System > Power State Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Power State > Host has been powered off.CIM > System > IP Change Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >

IP Address Changed > IP Address has beenchanged

CIM > System > RAID > RAID Drive Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem LifeCycle > Removed

CIM > System > RAID > RAID Drive Added Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem LifeCycle > Added

Trang 17

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID Unsupported

Drive

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem

Configuration > Unsupported Drive

v CIM > System > RAID > RAID PFA Drive

v CIM > System > RAID > RAID PFA Drive FRU

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem

Operational Condition > Predictive FailureAnalysis (PFA)

CIM > System > RAID > RAID Drive Clear

Detected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveClear > Detected

CIM > System > RAID > RAID Drive Clear Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveClear > Failed

CIM > System > RAID > RAID Drive Clear

Complete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveClear > Completed

CIM > System > RAID > RAID Sync Detected Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveSynchronization > Detected

CIM > System > RAID > RAID Sync Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveSynchronization > Failed

CIM > System > RAID > RAID Sync Complete Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveSynchronization > Completed

CIM > System > RAID > RAID Drive Verify

Detected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveVerify > Detected

CIM > System > RAID > RAID Drive Verify Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveVerify > Failed

CIM > System > RAID > RAID Drive Verify

Complete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveVerify > Completed

CIM > System > RAID > RAID Controller Added Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >RAID Controller > RAID Subsystem Life Cycle >Added

CIM > System > RAID > RAID Controller

Replaced

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >RAID Controller > RAID Subsystem Life Cycle >Replaced

CIM > System > RAID > RAID Config Fail Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >RAID Controller > RAID Subsystem

Configuration > Failed

Trang 18

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID No Controllers Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >RAID Controller > RAID Subsystem

Configuration > No ControllersCIM > System > RAID > RAID Controller

Mismatched Versions

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >RAID Controller > RAID Subsystem

Configuration > Mismatched Versions

v CIM > System > RAID > RAID Controller Fail

v CIM > System > RAID > RAID Polling Fail

v CIM > System > RAID > RAID Controller BadStripes

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >RAID Controller > RAID Subsystem OperationalCondition > Failed

CIM > System > RAID > RAID Controller Failover Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >RAID Controller > RAID Subsystem OperationalCondition > Failover

CIM > System > RAID > RAID Test Event Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >RAID Controller > RAID Subsystem OperationalCondition > Test

v CIM > System > RAID > RAID Enclosure Fail

v CIM > System > RAID > RAID Enclosure OK

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >RAID Controller > RAID Subsystem Enclosure >Failed

CIM > System > Host Bus Adapter Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >RAID Controller > RAID Subsystem Adapter >Status

CIM > System > RAID > RAID Logical Drive OK Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > OK

v CIM > System > RAID > RAID Logical DriveCritical

v CIM > System > RAID > RAID Logical DriveCritical Periodic

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Critical

CIM > System > RAID > RAID Logical DriveBlocked

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Blocked

CIM > System > RAID > RAID Logical DriveUnblocked

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Unblocked

CIM > System > RAID > RAID Logical DriveAdded

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Added

CIM > System > RAID > RAID Logical DriveRemoved

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Removed

Trang 19

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree

v CIM > System > RAID > RAID Logical Drive

CIM > System > RAID > RAID Array Rebuild

Detected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArrayRebuild > Detected

CIM > System > RAID > RAID Array Rebuild Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArrayRebuild > Failed

CIM > System > RAID > RAID Array Rebuild

Complete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArrayRebuild > Completed

CIM > System > RAID > RAID Array Sync

Detected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArraySynchronization > Detected

CIM > System > RAID > RAID Array Sync Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArraySynchronization > Failed

CIM > System > RAID > RAID Array Sync

Complete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArraySynchronization > Completed

CIM > System > RAID > RAID Migration

Detected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemMigration > Detected

CIM > System > RAID > RAID Migration Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemMigration > Failed

CIM > System > RAID > RAID Migration

Complete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemMigration > Completed

CIM > System > RAID > RAID Compression

Detected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompression > Detected

CIM > System > RAID > RAID Compression Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompression > Failed

CIM > System > RAID > RAID Compression

Complete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompression > Completed

CIM > System > RAID > RAID Decompression

Detected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemDecompression > Detected

Trang 20

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID Decompression

Fail

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemDecompression > Failed

CIM > System > RAID > RAID DecompressionComplete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemDecompression > Completed

CIM > System > RAID > RAID FlashCopy®

Detected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemFlashCopy > Detected

CIM > System > RAID > RAID FlashCopy Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemFlashCopy > Failed

CIM > System > RAID > RAID FlashCopyComplete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemFlashCopy > Completed

CIM > System > RAID > RAID CompactionDetected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompaction > Detected

CIM > System > RAID > RAID Compaction Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompaction > Failed

CIM > System > RAID > RAID CompactionComplete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompaction > Completed

CIM > System > RAID > RAID ExpansionDetected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemExpansion > Detected

CIM > System > RAID > RAID Expansion Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemExpansion > Failed

CIM > System > RAID > RAID ExpansionComplete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemExpansion > Completed

CIM > System > RAID > RAID CopybackDetected

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCopyback > Detected

CIM > System > RAID > RAID Copyback Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCopyback > Failed

CIM > System > RAID > RAID CopybackComplete

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCopyback > Completed

Trang 21

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID Init Detected Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemInitialization > Detected

CIM > System > RAID > RAID Init Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemInitialization > Failed

CIM > System > RAID > RAID Init Complete Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemInitialization > Completed

v CIM > System > RAID > RAID Defunct Drive

v CIM > System > RAID > RAID Defunct Drive

FRU

Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem DefunctDrive > Detected

CIM > System > RAID > RAID Defunct Replaced Managed Resource > Managed System Resource >

Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem DefunctDrive > Replaced

v CIM > System > RAID > RAID Dead Battery

v CIM > System > RAID > RAID Dead Battery

Cache

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Battery >Operational Condition > Failed

CIM > System > RAID > RAID Controller Battery

Overtemp

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Battery >Temperature > High

CIM > System > RAID > RAID Controller Battery

Temp Normal

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Battery >Temperature > Normal

CIM > System > RAID > RAID Enclosure Fan

Removed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan > RAIDSubsystem Life Cycle > Removed

CIM > System > RAID > RAID Enclosure Fan

Installed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan > RAIDSubsystem Life Cycle > Added

CIM > System > RAID > RAID Enclosure Fan Fail Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Fan > RAIDSubsystem Operational Condition > FailedCIM > System > RAID > RAID Enclosure Fan OK Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Fan > RAIDSubsystem Operational Condition > OKCIM > System > RAID > RAID Enclosure Temp

Fail

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Sensor >Numeric Sensor > Temperature Sensor > HighCIM > System > RAID > RAID Enclosure Temp

OK

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Sensor >Numeric Sensor > Temperature Sensor > NormalCIM > System > RAID > RAID Enclosure Power

Supply Removed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > RAID Subsystem Life Cycle > RemovedCIM > System > RAID > RAID Enclosure Power

Supply Installed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > RAID Subsystem Life Cycle > Added

Trang 22

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID Enclosure Power

Supply Fail

Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > RAID Subsystem Operational Condition

> FailedCIM > System > RAID > RAID Enclosure Power

Supply OK

Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > RAID Subsystem Operational Condition

> OKMPA > Unknown Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Unknown > Unknown

MPA > Component > Chassis > Configuration Managed Resource > Managed System Resource >

Physical Resource > Physical Package > PhysicalFrame > Chassis > Operational Condition >Configuration Error

v MPA > Component > Chassis > MaximumCooling

v MPA > Component > Chassis > Failed

v MPA > Component > Chassis > CoolingCapacity

Managed Resource > Managed System Resource >Physical Resource > Physical Package > PhysicalFrame > Chassis > Operational Condition >Temperature

MPA > Component > Bus > Communication Managed Resource > Managed System Resource >

Physical Resource > Physical Package > PhysicalFrame > Chassis > Operational Condition > BusCommunication Failure

MPA > Component > Chassis > Direct SerialAttach Module > Disabled

Managed Resource > Managed System Resource >Physical Resource > Physical Package > PhysicalFrame > Chassis > Open Fabric Manager >Deactivated

MPA > Component > Blade Server > Removed Managed Resource > Managed System Resource >

Physical Resource > Physical Connector > Slot >Life Cycle > Removed

MPA > Component > Blade Server > Inserted Managed Resource > Managed System Resource >

Physical Resource > Physical Connector > Slot >Life Cycle > Added

MPA > Component > Blade Server > Incompatible Managed Resource > Managed System Resource >

Physical Resource > Physical Connector > Slot >Operational Condition > Configuration Error

v MPA > Component > Blade Server >

MPA > Component > Blade Server > VPD Managed Resource > Managed System Resource >

Physical Resource > Physical Connector > Slot >Operational Condition > Not RecognizedMPA > Component > Blade Server > Throttled Managed Resource > Managed System Resource >

Physical Resource > Physical Connector > Slot >Operational Condition > Throttled

MPA > Component > Blade Server >

Communication

Managed Resource > Managed System Resource >Physical Resource > Physical Connector > Slot >Operational Condition > Communication ErrorMPA > Component > Blade Server > Capacity on

Demand

Managed Resource > Managed System Resource >Physical Resource > Physical Connector > Slot >Capacity On Demand > Activated

Trang 23

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Service Processor >

Removed

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor > LifeCycle > Removed

MPA > Component > Service Processor > Inserted Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Hardware Control Point > Service Processor > LifeCycle > Added

MPA > Component > Service Processor >

Network Stack

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Network Stack StartedMPA > Component > Service Processor > Restart Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Restarted

v MPA > Component > Service Processor >

MPA > Component > Service Processor >

Communication

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Blade Server BaseboardManagement Controller (BMC) CommunicationError

v MPA > Component > Service Processor >

Failover

v MPA > Component > Service Processor > Active

v MPA > Component > Service Processor >

Inactive

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Failover

MPA > Component > Service Processor >

Redundancy

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > RedundancyMPA > Component > Service Processor > Test Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Test

v CIM > System > IPMI Log

v MPA > Component > Service Processor > Log

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Hardware Log > Threshold

MPA > Component > Service Processor >

Out-of-Band > Enabled

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Out-Of-Band Connection > ActivatedMPA > Component > Service Processor >

Out-of-Band > Disabled

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Out-Of-Band Connection > Deactivated

Trang 24

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Service Processor >

Out-of-Band > Port

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Out-Of-Band Connection > Port ChangedMPA > Component > Service Processor > Secure

Out-of-Band > Enabled

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Secure Out-Of-Band Connection > ActivatedMPA > Component > Service Processor > Secure

Out-of-Band > Disabled

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Secure Out-Of-Band Connection > DeactivatedMPA > Component > Service Processor > Secure

Out-of-Band > Port

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Secure Out-Of-Band Connection > Port ChangedMPA > Component > Service Processor > User

Account > Inactive

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >User Account > Deactivated

MPA > Component > Service Processor > UserAccount > Active

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >User Account > Activated

MPA > Component > Service Processor >

Password > Change Required

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >User Account > Password Change RequiredCIM > System > System Enclosure Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > IntrusionMPA > Component > Server > Configuration Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > ConfigurationError

CIM > System > Automatic Server Restart Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > AutomaticServer Restart

MPA > Component > Server Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > Reset

MPA > Component > Server > Power > Disabled Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > Power DisabledMPA > Component > Server > Power > Disabled Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > Power EnabledMPA > Component > Server > Power > Hibernate Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > HibernateMPA > Component > Server > Power > Standby Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > Standby

Trang 25

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Server > Power > Restart Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > RestartedMPA > Component > Server > Power > Off Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > Powered OffMPA > Component > Server > Power > On Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > Powered OnMPA > Component > Server > State Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > State ChangeMPA > Component > BIOS > Corrupted Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > BIOS CorruptedMPA > Component > BIOS > Fault Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > BIOS FaultMPA > Component > SMP Expansion Module >

Disabled

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Server > Operational Condition > SMP ExpansionModule Disabled

v CIM > System > PFA

v MPA > Component > PFA

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Server > Operational Condition > PredictiveFailure Analysis (PFA)

CIM > System > Error Log Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Operational Condition > Log

MPA > Server Watchdog > Boot Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Deployment > Boot Failure

MPA > Server Watchdog > POST Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Deployment > POST Failure

MPA > Server Watchdog > OS Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Deployment > FailedOs

MPA > Server Watchdog > Loader Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Deployment > Load Failure

MPA > Platform Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Scalable Partition > Alerts

MPA > Platform Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Scalable Partition > Logical PartitionState Change

MPA > Platform Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Scalable Partition > Physical PartitionMode Change

CIM > System > Lease Expiration Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Asset > Lease Expired

Trang 26

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > Warranty Expiration Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Server > Asset > Warranty Expired

MPA > Component > Multiplexer ExpansionModule > Removed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Multiplexer Card Module > Life Cycle

> RemovedMPA > Component > Multiplexer Expansion

Module > Inserted

Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Multiplexer Card Module > Life Cycle

> AddedMPA > Component > Multiplexer Expansion

Module > Failed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Multiplexer Card Module > OperationalCondition > Failed

MPA > Component > Alarm Panel > Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Alarm Panel Module > Life Cycle >Removed

MPA > Component > Alarm Panel > Inserted Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Alarm Panel Module > Life Cycle >Added

MPA > Component > Alarm Panel > Power > Off Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Alarm Panel Module > Power > OffMPA > Component > Alarm Panel > Power > On Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Alarm Panel Module > Power > OnMPA > Component > Clock Module > Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Clock Module > Life Cycle > RemovedMPA > Component > Clock Module > Inserted Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Clock Module > Life Cycle > AddedMPA > Component > Clock Module > Power >

Off

Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Clock Module > Power > OffMPA > Component > Clock Module > Power >

On

Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Clock Module > Power > OnMPA > Component > I/O Interposer > Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Input/Output (I/O) Module > LifeCycle > Removed

MPA > Component > I/O Interposer > Inserted Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Input/Output (I/O) Module > LifeCycle > Added

MPA > Component > Chassis > Direct SerialAttach Module > Removed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Baggage Cart Module > Life Cycle >Removed

Trang 27

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Chassis > Direct Serial

Attach Module > Inserted

Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Baggage Cart Module > Life Cycle >Added

MPA > Component > VRM > Configuration Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Voltage Regulator Module (VRM) >Configuration > Change

MPA > Component > VRM > Failed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Voltage Regulator Module (VRM) >Operational Condition > Failed

MPA > Component > Media Tray > Failed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Media Tray Module > OperationalCondition > Failed

MPA > Component > Media Tray > Temperature

Unavailable

Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Media Tray Module > Temperature >Not Available

MPA > Component > Concurrent KVM > Failed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Keyboard, Video, Mouse (KVM)Module > Operational Condition > FailedMPA > Component > Front Panel > Failed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > LogicalModule > Front Panel Module > OperationalCondition > Failed

CIM > System > Processor Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Processor >Life Cycle > Removed

CIM > System > Processor Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Processor >Life Cycle > Added

v MPA > Component > CPU > Configuration

v MPA > Component > CPU > Absent

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Processor >Operational Condition > Configuration ErrorMPA > Component > CPU > Failed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Processor >Operational Condition > Failed

CIM > System > Processor PFA Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Processor >Operational Condition > Predictive FailureAnalysis (PFA)

MPA > Component > I/O Module > Removed Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Switch > Life Cycle > Removed

MPA > Component > I/O Module > Inserted Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Switch > Life Cycle > Added

v MPA > Component > I/O Module > Power >

Trang 28

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > I/O Module > Power > On Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Switch > Power > On

MPA > Component > I/O Module >

Configuration

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > ConfigurationChange

MPA > Component > I/O Module > Mismatch Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Switch > Operational Condition > ConfigurationError

MPA > Component > I/O Module > Power >

Disabled

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > Not Recognized

v MPA > Component > I/O Module > InsufficientPower

v MPA > Component > I/O Module > Fuse

v MPA > Component > I/O Module > OverCurrent®

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > Power StateChanged

v MPA > Component > I/O Module > Failed

v MPA > Component > I/O Module > POST

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > FailedMPA > Component > I/O Module > Redundancy Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Switch > Operational Condition > Redundancy

v MPA > Component > I/O Module > Stacking >

MPA > Component > I/O Module > Zoning Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Switch > Operational Condition > ZoningMPA > Component > I/O Module >

Communication

Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > CommunicationError

v MPA > Component > Fan > Removed

v MPA > Component > Fan Pack > Removed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan > LifeCycle > Removed

v MPA > Component > Fan > Inserted

v MPA > Component > Fan Pack > Inserted

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan > LifeCycle > Added

MPA > Component > Fan > Configuration Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Fan >Operational Condition > Configuration ErrorCIM > System > Fan Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Fan >Operational Condition > Threshold

v MPA > Component > Fan > Failed

v MPA > Component > Fan Pack > Failed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan >Operational Condition > Failed

Trang 29

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree

v MPA > Component > Fan > PFA

v MPA > Component > Fan Pack > PFA

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan >Operational Condition > Predictive FailureAnalysis (PFA)

MPA > Component > DASD > Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Life Cycle > RemovedMPA > Component > DASD > Inserted Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Life Cycle > AddedMPA > Component > DASD > Configuration Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Operational Condition >Configuration Error

v CIM > System > DASD Backplane

v CIM > System > SMART Drive

v MPA > Component > DASD > Failed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Operational Condition >Failed

MPA > Component > DASD > PFA Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Operational Condition >Predictive Failure Analysis (PFA)

CIM > System > Disk Space Low Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Available Percentage >Disk Space

MPA > Component > Power Supply > Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > PowerSupply > Life Cycle > Removed

MPA > Component > Power Supply > Inserted Managed Resource > Managed System Resource >

Logical Resource > Logical Device > PowerSupply > Life Cycle > Added

v MPA > Component > Power Supply >

Configuration

v MPA > Component > Power Supply > Absent

Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > Operational Condition > ConfigurationError

v CIM > System > Power Supply

v MPA > Component > Power Supply > Failed

Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > Operational Condition > FailedMPA > Component > Power Supply > PFA Managed Resource > Managed System Resource >

Logical Resource > Logical Device > PowerSupply > Operational Condition > PredictiveFailure Analysis (PFA)

CIM > System > Memory Managed Resource > Managed System Resource >

Physical Resource > Physical Component > Chip

> Physical Memory > Life Cycle > RemovedCIM > System > Memory Managed Resource > Managed System Resource >

Physical Resource > Physical Component > Chip

> Physical Memory > Life Cycle > AddedMPA > Component > DIMM > Absent Managed Resource > Managed System Resource >

Physical Resource > Physical Component > Chip

> Physical Memory > Operational Condition >Configuration Error

Trang 30

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > Memory PFA Managed Resource > Managed System Resource >

Physical Resource > Physical Component > Chip

> Physical Memory > Operational Condition >Predictive Failure Analysis (PFA)

MPA > Component > DIMM > Failed Managed Resource > Managed System Resource >

Physical Resource > Physical Component > Chip

> Physical Memory > Operational Condition >Failed

MPA > Component > DIMM > Disabled Managed Resource > Managed System Resource >

Physical Resource > Physical Component > Chip

> Physical Memory > Operational Condition >Deactivated

MPA > Component > Management ModuleInterposer > Removed

Managed Resource > Managed System Resource >Physical Resource > Physical Connector >ManagementModule > Life Cycle > RemovedMPA > Component > Management Module

Interposer > Inserted

Managed Resource > Managed System Resource >Physical Resource > Physical Connector >ManagementModule > Life Cycle > AddedMPA > Component > Battery > Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Battery > LifeCycle > Removed

MPA > Component > Battery > Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Battery > LifeCycle > Added

MPA > Component > Battery > Unreliable Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Battery >Operational Condition > Not ReliableMPA > Component > Battery > Failed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Battery >Operational Condition > Failed

MPA > Component > RAID > Failed Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >RAID Controller > Operational Condition > FailedMPA > Component > Storage Module > Removed Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Storage Subsystem > Life Cycle > RemovedMPA > Component > Storage Module > Inserted Managed Resource > Managed System Resource >

Logical Resource > System > Computer System >Storage Subsystem > Life Cycle > Added

v MPA > Component > Storage Module > Failed

v MPA > Component > Storage Module >

MPA > Component > USB > Removed Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Controller >USB Controller > Life Cycle > RemovedMPA > Component > USB > Inserted Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Controller >USB Controller > Life Cycle > Added

MPA > Component > USB > Over Current Managed Resource > Managed System Resource >

Logical Resource > Logical Device > Controller >USB Controller > Operational Condition > OverCurrent

Trang 31

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Power Subsystem > Over

Power

Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Power Exceeded

MPA > Component > Power Subsystem > Over

Current

Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Over Current

MPA > Component > Power Subsystem > Low

Fuel

Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Low Fuel

MPA > Component > Power Subsystem > Over

Subscription

Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Over Power SubscriptionMPA > Component > Power Subsystem >

Mismatched Power Supplies

Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Configuration ErrorMPA > Component > Power Subsystem >

Redundancy

Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Redundancy

CIM > System > Network Adapter Managed Resource > Managed System Resource >

Physical Resource > Physical Package > Card >Life Cycle > Network interface card (NIC)Removed

CIM > System > Network Adapter Managed Resource > Managed System Resource >

Physical Resource > Physical Package > Card >Life Cycle > Network interface card (NIC) AddedCIM > System > Network Adapter Managed Resource > Managed System Resource >

Physical Resource > Physical Package > Card >Operational Condition > Network interface card(NIC) Offline

CIM > System > Network Adapter Managed Resource > Managed System Resource >

Physical Resource > Physical Package > Card >Operational Condition > Network interface card(NIC) Online

CIM > System > Network Adapter Managed Resource > Managed System Resource >

Physical Resource > Physical Package > Card >Operational Condition > Network interface card(NIC) Failed

MPA > Component > I/O Board > Failed Managed Resource > Managed System Resource >

Physical Resource > Physical Package > Card >Operational Condition > I/O Board FailureMPA > Component > Processor Board > Failed Managed Resource > Managed System Resource >

Physical Resource > Physical Package > Card >Operational Condition > Processor Board FailureMPA > Component > Expansion Card > Failed Managed Resource > Managed System Resource >

Physical Resource > Physical Package > Card >Operational Condition > Daughter Card Failure

Trang 32

Table 2 Hardware-platform events cross reference (continued)

IBM Director 5.20 event name

IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree

v CIM > System > Redundant Network AdapterFailover

v CIM > System > Redundant Network AdapterSwitchBack

v CIM > System > Redundant Network AdapterSwitchOver

Managed Resource > Managed System Resource >Physical Resource > Physical Package > Card >Operational Condition > Network interface card(NIC) Failover

MPA > Component > Blade Expansion Unit >

Failed

Managed Resource > Managed System Resource >Physical Resource > Physical Package > BladeExpansion Unit > Operational Condition > BladeExpansion Unit Failed

v CIM > System > Voltage

v MPA > Environmental > Voltage

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Sensor >Numeric Sensor > Voltage Sensor > Out Of Range

v CIM > System > Temperature

v MPA > Environmental > Temperature

Managed Resource > Managed System Resource >Logical Resource > Logical Device > Sensor >Numeric Sensor > Temperature Sensor > High

IBM BladeCenter and System x platform-specific events

The events listed in this section are specific for the IBM BladeCenter and System x hardware platforms In IBM Director 5.20, these were called the CIM and MPA events In IBM Systems Director 6.1, the CIM and MPA events are still used, but are mapped to hardware component categories Use the Hardware-platform event cross-reference table to find the 5.20 event name and its equivalent 6.1 event name.

If you select the CIM check box in the Event Filter Builder tree, the event filter will

process all of the event types that are specified in the CIM subtree.

Event type Event text Severity Category Extended details

applicable

Notapplicable

None

CIM > System

The System events occur when a change in the state of a Platform Agent managed system or Common Agent managed system managed system is detected These events also occur when a change in the state of a Hardware Management Console (HMC) is detected.

Details

The CIM > System event types use a standard set of extended details.

Trang 33

If you select the System check box in the Event Filter Builder tree, the event filter

will process all of the event types that are specified in the System subtree.

Event type Event text Severity Category Extended details

applicable

Notapplicable

None

CIM > System > Automatic Server Restart:

The Automatic Server Restart event occurs when the operating system locks up and no longer responds Subsequently, a system restart (reboot) begins This event

is supported on servers with Intelligent Platform Management Interface (IPMI).

AutomaticServer Restart

The last system restart was due to theautomatic server restart hardware

AutomaticServer Restart

The last system restart was not due tothe automatic server restart hardware

Informational Resolution None

CIM > System > DASD Backplane:

The DASD Backplane event occurs when the Remote Supervisor Adapter detects that the state of the system hard disk drive changes with respect to its availability.

DASDBackplane

Drive drive has reported a fault This

event must be cleared manually

where drive is the affected hard disk

drive

Critical Alert None

CIM > System > Disk Space Low:

The Disk Space Low event occurs when the state of system hard disk drive space changes with respect to user-defined levels of hard disk drive space remaining By default, the warning level is 5% remaining and critical level is 3% remaining.

Trang 34

v If the severity is Critical or Warning: Remove files from the specified hard disk

or lower the minimum threshold.

v If the category is Resolution: The error has been resolved This event is informative only.

Details

Event type Event text Severity Category

Additional extended details

Disk Space Low Logical drive name fell below threshold

of threshold MB The current value is

value MB.

where:

v name is the affected logical drive.

v threshold is the critical threshold

value

v value is the amount of current disk

space available

Critical Alert None

Disk Space Low Logical drive name fell below threshold

of threshold MB The current value is

value MB.

where:

v name is the affected logical drive.

v threshold is the warning threshold

value

v value is the amount of current disk

space available

Disk Space Low Logical drive name free space is normal.

The current value is value MB.

where name is the affected logical drive and value is the amount of current disk

space available

Informational Resolution None

Disk Space Low Logical drive name status could not be

determined

where name is the affected logical drive.

Unknown Resolution None

CIM > System > Error Log:

The Error Log event occurs when the Remote Supervisor Adapter detects that its error log is at 75% or 100% of its capacity.

Trang 35

Event type Event text Severity Category

Additional extended details

Error Log The system management processor error

log is 75% full This event must becleared manually

Warning Alert None

Error Log The system management processor error

log is full This event must be clearedmanually

Warning Alert None

CIM > System > Fan:

The Fan event occurs when the state of a system fan has changed with respect to the manufacturer-defined revolutions per minute (rpm) values This event is sent when a fan stops, is removed, or is not performing optimally.

Resolution

v If the severity is Critical: Replace the specified fan that has failed.

v If the category is Resolution: The error has been resolved This event is

informative only.

Details

Event type Event text Severity Category

Additional extended details

Fan Fan Sensor number fell below threshold

of threshold rpm The current value is

speed rpm.

where:

v number is the affected fan sensor.

v threshold is the critical fan threshold

value

v speed is the current fan speed.

Note:This event must be clearedmanually

Critical Alert None

Fan Fan Sensor number reports normal.

where number is the affected fan sensor.

Informational Resolution None

CIM > System > Host Bus Adapter:

The Host Bus Adapter events occur when a QLogic Fibre Channel Host Bus

Adapter detects a change in its state or configuration.

Trang 36

CIM > System > IP Change:

The IP Change event occurs when a change in an IP address used by the HMC is detected.

Resolution

No resolution This event is informative only.

Details

The CIM > System event types for HMC use a standard set of extended details.

Event type Event text Severity Category Additional extended details

IP Change The IP Address associated with HMC number

has changed

where number identifies the HMC.

Informational Alert v Description indicates the

type of event

v OldIPAddress indicates the

previous IP address used

by the HMC

v NewIPAddress indicates the

new IP address used bythe HMC

CIM > System > IVM Unconfigured:

The IVM Unconfigured event occurs when an IVM becomes unconfigured.

Typically, this occurs when a user migrates an IVM-managed system to HMC management.

Resolution

No resolution This event is informative only.

Details

The CIM > System event types for HMC use a standard set of extended details.

Event type Event text Severity Category Additional extended details

IVM Unconfigured IVM is not configured Informational Alert None

CIM > System > IPMI Log:

The IPMI Log event occurs when the system-management processor error log is 75% full or full This event is supported on servers with Intelligent Platform Management Interface (IPMI).

Resolution

To correct this problem, reduce the number of events in the event log You can clear the event log using the BIOS configuration utility on the server or remotely using the OSA SMBridge utility See the documentation for your server or the IBM

Redbooks publication IBM eServerxSeries® and BladeCenter Server Management

(SG24-6495).

Trang 37

Event type Event text Severity Category

Additional extended details

IPMI Log The system management processor error

log is 75% full This event must becleared manually

Warning Alert None

IPMI Log The system management processor error

log is full This event must be clearedmanually

Warning Alert None

CIM > System > Lease Expiration:

The Lease Expiration event occurs when the system lease expiration date has been reached with respect to the value configured for the date in the Asset ID task.

Resolution

v If the severity is Warning: The lease has expired.

v If the category is Resolution: The error has been resolved This event is informative only.

Details

The date value is provided by the Asset ID task The Lease page in the Asset ID

task includes the End Date field where you can set the lease expiration date The

date is stored in the IBMPSG_Lease.LeaseEndDate CIM property that is monitored

at regular poll intervals A CIM indication is generated when the system CIMOM starts and when a state change is detected relative to the internal poll interval.

Event type Event text Severity Category Additional extended details

Lease Expiration The lease on system has expired It expired

on date.

where system is the affected system and date

is the lease expiration date

Lease Expiration The lease on system is normal It will expire

on date.

where system is the affected system and date

is the lease expiration date

Informational Resolution None

CIM > System > Life Cycle:

The Life Cycle event occurs when an LPAR is created or deleted on a system managed by the Hardware Management Console (HMC) The event also occurs when a CEC is managed by the HMC or removed from management by the HMC.

Resolution

No resolution This event is informative only.

Trang 38

The CIM > System event types for HMC use a standard set of extended details.

Additional extended details

Life Cycle LPAR name has been created.

where name identifies the LPAR created.

Minor Alert LifeCycleEvent indicates

whether the CEC wasadded or removed frommanagement by the HMC.Life Cycle LPAR name has been deleted.

where name identifies the deleted LPAR.

Minor Alert LifeCycleEvent indicates

whether the CEC wasadded or removed frommanagement by the HMC.Life Cycle CEC cec is now managed by HMC hmc.

where cec identifies the CEC and hmc identifies the

HMC

Minor Alert LifeCycleEvent indicates

whether the CEC wasadded or removed frommanagement by the HMC.Life Cycle CEC cec is no longer managed by HMC hmc.

where cec identifies the CEC and hmc identifies the

HMC

Minor Alert LifeCycleEvent indicates

whether the CEC wasadded or removed frommanagement by the HMC

CIM > System > Memory:

The Memory event occurs when the currently available memory in a system changes with respect to availability due to a modification during a system shut down.

Event type Event text Severity Category Additional extended details

Memory Memory configuration reduced from

previous MB to current MB.

where previous is the previous memory size and current is the current memory size.

Memory Memory configuration increased from

previous MB to current MB.

where previous is the previous memory size and current is the current memory size.

Informational Resolution None

CIM > System > Memory PFA:

The Memory PFA event occurs when a dual inline memory module (DIMM) in a system is about to fail.

Resolution

v If the severity is Critical: Replace the specified DIMM that is failing or has failed.

Trang 39

v If the category is Resolution: The error has been resolved This event is informative only.

Details

Event type Event text Severity Category Additional extended details

Memory PFA Memory device identified as memory in

bank slot is predicting an imminent failure.

where slot is the affected memory slot.

Memory PFA Memory device identified as memory in

bank slot is not predicting a failure.

where slot is the affected memory slot.

Informational Resolution None

CIM > System > Network Adapter:

The Network Adapter events occur when a network interface card (NIC) in a system fails, goes offline, or goes online.

Resolution

v If the severity is Critical or Minor: Replace the specified NIC that has failed.

v If the category is Resolution: The error has been resolved This event is informative only.

Details

If you select the Network Adapter check box in the Event Filter Builder tree, the

event filter will process all of the event types that are specified in the Network Adapter subtree.

Additional extended details

applicable

Notapplicable

v DeviceID is the ID for

the component if thereare more than one of thesame component andyou are trying to fix aparticular instance

v Resolution provides

information that canhelp resolve a hardwareproblem in the server

You can choose to select specific event types that are displayed under the Network Adapter node in the Event Filter Builder tree The event filter will process only the event types that you select.

Trang 40

Event type Event text Severity Category Additional extended details

Failed The network adapter failed Critical Alert v DeviceID is the ID for the

component if there aremore than one of the samecomponent and you aretrying to fix a particularinstance

v Resolution provides

information that can helpresolve a hardwareproblem in the server.Offline The network adapter is offline Minor Alert v DeviceID is the ID for the

component if there aremore than one of the samecomponent and you aretrying to fix a particularinstance

v Resolution provides

information that can helpresolve a hardwareproblem in the server.Online The network adapter is online Informational Resolution v DeviceID is the ID for the

component if there aremore than one of the samecomponent and you aretrying to fix a particularinstance

v Resolution provides

information that can helpresolve a hardwareproblem in the server

CIM > System > PFA:

The PFA event occurs when the Remote Supervisor Adapter detects that a component in a system is about to fail.

PFA Predictive Failure Detected Please check

the system management processor errorlog for more information This eventmust be cleared manually

Critical Alert None

CIM > System > Power State:

The Power State event occurs when a change in the power state of a CEC or LPAR

is detected.