Command output in this release might vary from command output in previous releases.White papers and briefs v IBM Systems Director ftp://ftp.software.ibm.com/common/ssi/sa/wh/n/xbw03006us
Trang 4Before using this information and the product it supports, read the information in “Notices” on page 281.
© Copyright IBM Corporation 1999, 2011.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract
Trang 5About this publication vii
Conventions and terminology vii
Publications and related information vii
Web resources x
How to send your comments xi
Chapter 1 Hardware platform events 1
IBM BladeCenter and System x platform-specific events 18
CIM events 18
MPA events 70
IBM Power platform-specific events 125
Computer System 125
Ethernet Port 136
Fan 137
Fibre Channel Port 138
Memory 139
Optical Drive 141
PCI Device 142
Physical Volume 143
Processor 144
USB Port 145
IBM System Storage platform-specific events 146
Battery 147
Disk Drive 147
RAID Controller 148
Storage Pool 148
Storage Subsystem 148
Storage Volume 149
Switch 149
PET events 149
PET > Environmental 150
PET > Firmware 152
PET > Hardware 154
PET > System 156
SNMP events 157
ibmSystemMIB 158
ibmSystemRaid 170
Chapter 2 IBM Systems Director tasks, software, and operating system events 201
Director > Director Agent 201
Director > Director Agent > Process Monitors 201
Director > Director Agent > Resource Monitors 203
Director > Scheduler 204
Director > Scheduler > Job 204
Director > Scheduler > System 205
IBM Systems Director Program events 207
Agent events 207
Automation Event Actions events 207
Security 208
Status events 210
System Configuration events 210
Updates 212
Virtualization events 215
Director > Correlation > Common Agent events 223
Operating System 224
Trang 6CIM > Windows NT Event Log 225
CIM > Windows NT Service 225
CIM > Windows Registry 225
Windows Event Log events 225
Chapter 3 Sources of events in an IBM Systems Director environment 227
CIM event sources 227
The MPA event source in IBM Director, version 5.10 and later 227
PET event source 228
ibmSystemMIB event source 228
Chapter 4 Extended details and variable-binding information 229
Extended details for CIM events 229
Extended details for HMC CIM events 229
Extended details for the Director > Director Agent events 229
Extended details for the IBM Systems Director Program > Security events 230
Extended details for MPA events 230
Extended details for PET events 230
Variable-binding information for IBM Systems Director SNMP events 231
Chapter 5 CIM indications in IBM Systems Director 233
IBM_MgmtHwLogStatus CIM indication 233
IBMx_AutomaticServerRestartEvent CIM indication 234
IBMPSG_ChassisEvent CIM indication 234
IBMPSG_DASDBackplaneEvent CIM indication 235
IBMPSG_ErrorLogEvent CIM indication 235
IBMPSG_FanEvent CIM indication 236
IBMPSG_GenericFanEvent CIM indication 236
IBMPSG_GenericVoltageEvent CIM indication 237
IBMPSG_LeaseExpirationEvent CIM indication 237
IBMPSG_MemoryPFEvent CIM indication 238
IBMPSG_NetworkAdapterFailedEvent CIM indication 238
IBMPSG_NetworkAdapterOfflineEvent CIM indication 239
IBMPSG_NetworkAdapterOnlineEvent CIM indication 239
IBMPSG_PFAEvent CIM indication 240
IBMPSG_PowerSupplyEvent CIM indication 240
IBMPSG_ProcessorPFEvent CIM indication 241
IBMPSG_RedundantNetworkAdapterEvent CIM indication 241
IBMPSG_RedundantNetworkAdapterSwitchbackEvent CIM indication 242
IBMPSG_RedundantNetworkAdapterSwitchoverEvent CIM indication 242
IBMPSG_RemoteLoginEvent CIM indication 243
IBMPSG_SMARTEvent CIM indication 243
IBMPSG_SPPowerSupplyEvent CIM indication 243
IBMPSG_StorageEvent CIM indication 244
Adjusting disk-space event threshold values on Linux systems 245
Adjusting disk-space event threshold values on Windows systems 245
IBMPSG_TemperatureEvent CIM indication 246
IBMPSG_VoltageEvent CIM indication 246
IBMPSG_WarrantyExpirationEvent CIM indication 247
ADPT_ArrayFlashCopyComplete CIM indication 247
ADPT_ArrayFlashCopyDetected CIM indication 247
ADPT_ArrayFlashCopyFail CIM indication 248
ADPT_ArrayRebuildComplete CIM indication 248
ADPT_ArrayRebuildDetected CIM indication 248
ADPT_ArrayRebuildFail CIM indication 249
ADPT_ArraySyncComplete CIM indication 249
ADPT_ArraySyncDetected CIM indication 249
ADPT_ArraySyncFail CIM indication 250
ADPT_CompactionComplete CIM indication 250
ADPT_CompactionDetected CIM indication 250
Trang 7ADPT_CompactionFail CIM indication 251
ADPT_CompressionComplete CIM indication 251
ADPT_CompressionDetected CIM indication 251
ADPT_CompressionFail CIM indication 252
ADPT_ConfigFail CIM indication 252
ADPT_ControllerAdded CIM indication 252
ADPT_ControllerBadStripes CIM indication 253
ADPT_ControllerBatteryOvertemp CIM indication 253
ADPT_ControllerBatteryTempNormal CIM indication 253
ADPT_ControllerFail CIM indication 254
ADPT_ControllerFailover CIM indication 254
ADPT_ControllerMismatchedVersions CIM indication 254
ADPT_ControllerReplaced CIM indication 255
ADPT_CopyBackComplete CIM indication 255
ADPT_CopyBackDetected CIM indication 255
ADPT_CopyBackFail CIM indication 256
ADPT_DeadBattery CIM indication 256
ADPT_DeadBatteryCache CIM indication 256
ADPT_DecompressionComplete CIM indication 257
ADPT_DecompressionDetected CIM indication 257
ADPT_DecompressionFail CIM indication 257
ADPT_DefunctDrive CIM indication 258
ADPT_DefunctDriveFRU CIM indication 258
ADPT_DefunctReplaced CIM indication 258
ADPT_DriveAdded CIM indication 259
ADPT_DriveClearComplete CIM indication 259
ADPT_DriveClearDetected CIM indication 259
ADPT_DriveClearFail CIM indication 260
ADPT_DriveRemoved CIM indication 260
ADPT_DriveVerifyComplete CIM indication 260
ADPT_DriveVerifyDetected CIM indication 261
ADPT_DriveVerifyFail CIM indication 261
ADPT_EnclosureFail CIM indication 261
ADPT_EnclosureFanFail CIM indication 262
ADPT_EnclosureFanInstalled CIM indication 262
ADPT_EnclosureFanOK CIM indication 262
ADPT_EnclosureFanRemoved CIM indication 263
ADPT_EnclosureOK CIM indication 263
ADPT_EnclosurePowerSupplyFail CIM indication 263
ADPT_EnclosurePowerSupplyInstalled CIM indication 264
ADPT_EnclosurePowerSupplyOK CIM indication 264
ADPT_EnclosurePowerSupplyRemoved CIM indication 264
ADPT_EnclosureTempFail CIM indication 265
ADPT_EnclosureTempOK CIM indication 265
ADPT_ExpansionComplete CIM indication 265
ADPT_ExpansionDetected CIM indication 266
ADPT_ExpansionFail CIM indication 266
ADPT_FlashCopyComplete CIM indication 266
ADPT_FlashCopyDetected CIM indication 266
ADPT_FlashCopyFail CIM indication 267
ADPT_InitComplete CIM indication 267
ADPT_InitDetected CIM indication 267
ADPT_InitFail CIM indication 267
ADPT_LogicalDriveAdded CIM indication 268
ADPT_LogicalDriveBlocked CIM indication 268
ADPT_LogicalDriveCritical CIM indication 268
ADPT_LogicalDriveCriticalPeriodic CIM indication 269
ADPT_LogicalDriveOffLine CIM indication 269
ADPT_LogicalDriveOK CIM indication 269
ADPT_LogicalDriveRemoved CIM indication 270
ADPT_LogicalDriveUnblocked CIM indication 270
Trang 8ADPT_MigrationComplete CIM indication 270
ADPT_MigrationDetected CIM indication 271
ADPT_MigrationFail CIM indication 271
ADPT_NoControllers CIM indication 271
ADPT_PFADrive CIM indication 272
ADPT_PFADriveFRU CIM indication 272
ADPT_PollingFail CIM indication 272
ADPT_RebuildComplete CIM indication 273
ADPT_RebuildDetected CIM indication 273
ADPT_RebuildFail CIM indication 273
ADPT_SyncComplete CIM indication 274
ADPT_SyncDetected CIM indication 274
ADPT_SyncFail CIM indication 274
ADPT_TestEvent CIM indication 275
ADPT_UnsupportedDrive CIM indication 275
LSI_RAID_HS_Fail CIM indication 275
LSI_RAID_LD_Degraded CIM indication 276
LSI_RAID_LD_Offline CIM indication 276
LSI_RAID_LD_Optimal CIM indication 276
LSI_RAID_PD_Fail CIM indication 277
LSI_RAID_PD_HS CIM indication 277
LSI_RAID_PD_PartOf_LD_Add CIM indication 277
LSI_RAID_PD_PartOf_LD_Fail CIM indication 278
LSI_RAID_RbldComplete CIM indication 278
LSI_RAID_RbldFail CIM indication 278
LSI_RAID_RbldStart CIM indication 279
LSI_RAID_SMART_Error CIM indication 279
Notices 281
Trademarks 282
Index 285
Trang 9About this publication
This publication provides reference information for commands available in IBM®Systems Director These commands fall into two broad categories:
v Commands used to perform IBM Systems Director tasks These commands are implemented using the IBM Systems Director command-line interface, IBM Systems Director.
v Commands used to configure, start, or stop IBM Systems Director and database These commands are entered directly on the command line when the action should be performed.
Conventions and terminology
These notices are designed to highlight key information:
Note: These notices provide important tips, guidance, or advice.
Important: These notices provide information or advice that might help you avoid inconvenient or difficult situations.
Attention: These notices indicate possible damage to programs, devices, or data.
An attention notice appears before the instruction or situation in which damage can occur.
Publications and related information
You can view the same content in the IBM Systems Director Information Center as PDF documents To view a PDF file, you need Adobe Acrobat Reader, which can
be downloaded for free from the Adobe Web site at http://get.adobe.com/reader/.
Information centers and topic collections
v IBM Systems http://publib.boulder.ibm.com/eserver/
View the IBM Systems information center landing page, which provides integrated information for multiple IBM Systems products.
v IBM Systems Director publib.boulder.ibm.com/infocenter/director/pubs/index.jsp Updated periodically, the IBM Systems Director topic collection contains the most up-to-date documentation available for IBM Systems Director.
v IBM Systems Director plug-ins http://publib.boulder.ibm.com/infocenter/director/pubs/topic/extensions/ extensionparent.html
View the IBM Systems information center for information about how to install and use plug-ins that extend the functionality of IBM Systems Director.
v IBM Systems Director Upward Integration Modules (UIMs) publib.boulder.ibm.com/infocenter/systems/topic/uims/fqs0_main.html Read the IBM Systems Director Upward Integration Modules (UIM) topic collection to learn about how to install and use upward integration modules and
Trang 10management packs that enable non-IBM workgroup and enterprise-management products to interpret and display data that is provided by Common Agent and Platform Agent.
v IBM Systems Director API Licensing http://www.ibm.com/vrm/4api1 View the license information regarding use of IBM Systems Director APIs and their associated documentation Fill out the form to request API access After your information is reviewed, you will be contacted with additional information regarding access to and use of the APIs.
Publications
Release Notes® 6.3
Provides an easy reference to planning, install and troubleshooting information for IBM Systems Director.
IBM Systems Director Planning Guide
Provides planning information, including hardware requirements for running IBM Systems Director components, supported IBM Systems Director hardware, operating systems, databases, and workgroup and enterprise systems-management software.
PDF files for installing IBM Systems Director Server
Provides detailed instructions to prepare for, install, and configure the IBM Systems Director Server.
PDF files for installing IBM Systems Director agents
Provides detailed instructions to prepare for and install IBM Systems Director agents on your managed systems, as well as, prepare for agentless managed systems.
PDF files for upgrading and migrating IBM Systems Director Server
Provides detailed instructions to upgrade and migrate the IBM Systems Director Server.
PDF files for upgrading and migrating IBM Systems Director agents
Provides detailed instructions to upgrade and migrate IBM Systems Director agents.
Systems Management Guide
Provides detailed instructions for using the Web interface and managing systems and resources in your environment.
Hardware Command Line User's Guide
Provides information about installing and using the Hardware Command
Trang 11Line (formerly known as the IBM Management Processor Command-Line Interface) Command output in this release might vary from command output in previous releases.
White papers and briefs
v IBM Systems Director
ftp://ftp.software.ibm.com/common/ssi/sa/wh/n/xbw03006usen/
XBW03006USEN.PDF
This paper provides a detailed overview of the changes in IBM Systems Director V6.1, including the new Web interface, security features, operating system agents, integrated plug-ins and additional plug-ins that can be separately
v Performance Tuning and Scaling Guide for IBM Systems Director 6.2
Hardware requirements for running IBM Systems Director Server
Provides information about how to plan, implement, configure, and use an IBM Systems Director Server to manage a large configuration with optimal
performance The Performance Tuning and Scaling Guide also contains
information about the following topics:
– Running IBM Systems Director plug-ins, such as IBM Systems Director Active Energy Manager®and IBM Scalable Systems Manager
– Integration with Tivoli® products
– Implementing high availability
IBM Redbooks® publications
Implementing IBM Systems Director 6.1
Tip: Be sure to note the date of publication and to determine the version of IBM Systems Director software to which the Redbooks publication refers.
Further information
Also see the following resources for further information about IBM Systems
Director:
v For alerts, discussions, news, parts and product information, and specific
troubleshooting workarounds for IBM Systems Director, see the Support & downloads Web site at http://www.ibm.com/support/us/en/.
Tip: To locate the information that you need, enter “IBM Systems Director” in
the Search field and click Search You can then narrow your results by document
type or product category, or use additional search terms.
Trang 12v For white papers, technotes, tips, and other documents related to IBM Systems Director, see the Techdocs Web site at http://w3.ibm.com/support/techdocs/ atsmastr.nsf/Web/Techdocs.
Tip: To locate the information that you need, either select the categories that you want to search or select UNMARKED to search all categories Then enter “IBM
Systems Director” in the for: field and click Search.
v For solutions to all types of situations that other customers have encountered, see the IBM Systems Director customer forum at www.ibm.com/
v IBM Systems Director Downloads www.ibm.com/systems/management/director/downloads/
View the IBM Systems Director Downloads Web site on ibm.com which provides links to download code IBM Systems Director, IBM Systems Director plug-ins, and IBM Systems Director upward integration modules.
v IBM Systems Director Documentation and Resources www.ibm.com/systems/management/director/resources/
View the IBM Systems Director Documentation and Resources Web site on ibm.com which provides links to product documentation, redbooks, redpapers, white papers, and learning modules related to IBM Systems Director, IBM Systems Director plug-ins, and IBM Systems Director upward integration modules.
v IBM Systems Director Upward Integration www.ibm.com/systems/software/director/downloads/integration.html View the IBM Systems Director Upward Integration Web site on ibm.com which provides more information about IBM Systems Director upward integration modules created by IBM and other companies IBM Systems Director UIMs enable third-party workgroup and enterprise systems-management products to interpret and display data that is provided by IBM Systems Director Platform Agent managed system.
v IBM Systems Director Best Practices Wiki www.ibm.com/developerworks/wikis/display/WikiPtype/
IBM+Systems+Director+Best+Practices+Wiki View updated documentation and best practices for IBM Systems Director on various systems.
v IBM Servers www.ibm.com/servers/
View the IBM Servers Web site to learn about IBM Systems server and storage products.
Trang 13v IBM ServerProven www.ibm.com/servers/eserver/serverproven/compat/us/
View the IBM ServerProven Web site to learn about hardware compatibility of IBM System x® and BladeCenter®systems with IBM applications and
middleware, including IBM Systems Director.
Forums
v IBM Systems Director www.ibm.com/developerworks/forums/forum.jspa?forumID=759 View the IBM Systems Director forum Web site on ibm.com to discuss product-related issues pertaining to IBM Systems Director, IBM Systems Director UIMs, and IBM Systems Director extensions This Web site includes a link for obtaining the forum using a Rich Site Summary (RSS) feed.
v IBM Systems Director SDK www.ibm.com/developerworks/forums/forum.jspa?forumID=1852&start=0 View the IBM Systems Director SDK forum Web site to discuss issues pertaining
to the IBM Systems Director Software Development Kit (SDK) This Web site includes a link for obtaining the forum using a Rich Site Summary (RSS) feed.
v IBM Systems www.ibm.com/developerworks/forums/dw_esforums.jsp View the IBM Systems forums Web site on ibm.com to learn about various forums that are available to discuss technology-related and product-related issues pertaining to IBM Systems hardware and software products This Web site includes a link for obtaining the forum using a Rich Site Summary (RSS) feed.
How to send your comments
Your feedback is important in helping to provide the most accurate and highest quality information.
If you have any comments about this book or any other IBM Systems Director publication, go to the IBM Systems Director information center Web site at publib.boulder.ibm.com/infocenter/director/pubs/index.jsp There you will find the feedback page where you can enter and submit comments.
Trang 15Chapter 1 Hardware platform events
IBM Systems Director introduces a new set of event types that categorize all possible events by the hardware or devices in your systems-management environment.
v For a hardware events severity-level name and number cross reference, see Table 1.
v For events that can be generated by multiple hardware platforms, including IBM BladeCenter and System x systems, see Table 2.
v For events that are specific to IBM Power®systems, see “ IBM Power platform-specific events.”
v For events that are specific to IBM System Storage®, see “IBM System Storage platform-specific events.”
Use the following table to map event severity-level names to numbers.
Table 1 Severity level name-number cross reference
Severity level name Severity number
Using your Web browser Find in page feature, use the following table to look up
events by their IBM Director 5.20 name The link provided displays the version 5.20 event documentation that still applies to the new version 6.1 event.
Table 2 Hardware-platform events cross reference
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > Service Event Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Resolution
CIM > System > Service Event Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Warning
CIM > System > Service Event Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Minor
CIM > System > Service Event Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Critical
CIM > System > Service Event Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Fatal
Trang 16Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > Temperature Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Resolution
CIM > System > Temperature Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Minor
CIM > System > Temperature Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Critical
CIM > System > Voltage Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Resolution
CIM > System > Voltage Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Minor
CIM > System > Voltage Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Operational Condition > Critical
CIM > System > Life Cycle Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Life Cycle > Virtual server has been created.CIM > System > Life Cycle Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Life Cycle > Virtual server has been deleted.CIM > System > Life Cycle Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Life Cycle > Host has been added
CIM > System > Life Cycle Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Life Cycle > Host has been deleted
CIM > System > Power State Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Power State > Virtual server has been started.CIM > System > Power State Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Power State > Virtual server has been shut down.CIM > System > Power State Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Power State > Host has been powered on.CIM > System > Power State Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Power State > Host has been powered off.CIM > System > IP Change Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >
IP Address Changed > IP Address has beenchanged
CIM > System > RAID > RAID Drive Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem LifeCycle > Removed
CIM > System > RAID > RAID Drive Added Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem LifeCycle > Added
Trang 17Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID Unsupported
Drive
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem
Configuration > Unsupported Drive
v CIM > System > RAID > RAID PFA Drive
v CIM > System > RAID > RAID PFA Drive FRU
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem
Operational Condition > Predictive FailureAnalysis (PFA)
CIM > System > RAID > RAID Drive Clear
Detected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveClear > Detected
CIM > System > RAID > RAID Drive Clear Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveClear > Failed
CIM > System > RAID > RAID Drive Clear
Complete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveClear > Completed
CIM > System > RAID > RAID Sync Detected Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveSynchronization > Detected
CIM > System > RAID > RAID Sync Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveSynchronization > Failed
CIM > System > RAID > RAID Sync Complete Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveSynchronization > Completed
CIM > System > RAID > RAID Drive Verify
Detected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveVerify > Detected
CIM > System > RAID > RAID Drive Verify Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveVerify > Failed
CIM > System > RAID > RAID Drive Verify
Complete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > RAID Subsystem DriveVerify > Completed
CIM > System > RAID > RAID Controller Added Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >RAID Controller > RAID Subsystem Life Cycle >Added
CIM > System > RAID > RAID Controller
Replaced
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >RAID Controller > RAID Subsystem Life Cycle >Replaced
CIM > System > RAID > RAID Config Fail Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >RAID Controller > RAID Subsystem
Configuration > Failed
Trang 18Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID No Controllers Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >RAID Controller > RAID Subsystem
Configuration > No ControllersCIM > System > RAID > RAID Controller
Mismatched Versions
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >RAID Controller > RAID Subsystem
Configuration > Mismatched Versions
v CIM > System > RAID > RAID Controller Fail
v CIM > System > RAID > RAID Polling Fail
v CIM > System > RAID > RAID Controller BadStripes
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >RAID Controller > RAID Subsystem OperationalCondition > Failed
CIM > System > RAID > RAID Controller Failover Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >RAID Controller > RAID Subsystem OperationalCondition > Failover
CIM > System > RAID > RAID Test Event Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >RAID Controller > RAID Subsystem OperationalCondition > Test
v CIM > System > RAID > RAID Enclosure Fail
v CIM > System > RAID > RAID Enclosure OK
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >RAID Controller > RAID Subsystem Enclosure >Failed
CIM > System > Host Bus Adapter Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >RAID Controller > RAID Subsystem Adapter >Status
CIM > System > RAID > RAID Logical Drive OK Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > OK
v CIM > System > RAID > RAID Logical DriveCritical
v CIM > System > RAID > RAID Logical DriveCritical Periodic
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Critical
CIM > System > RAID > RAID Logical DriveBlocked
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Blocked
CIM > System > RAID > RAID Logical DriveUnblocked
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Unblocked
CIM > System > RAID > RAID Logical DriveAdded
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Added
CIM > System > RAID > RAID Logical DriveRemoved
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem LogicalDrive > Removed
Trang 19Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree
v CIM > System > RAID > RAID Logical Drive
CIM > System > RAID > RAID Array Rebuild
Detected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArrayRebuild > Detected
CIM > System > RAID > RAID Array Rebuild Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArrayRebuild > Failed
CIM > System > RAID > RAID Array Rebuild
Complete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArrayRebuild > Completed
CIM > System > RAID > RAID Array Sync
Detected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArraySynchronization > Detected
CIM > System > RAID > RAID Array Sync Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArraySynchronization > Failed
CIM > System > RAID > RAID Array Sync
Complete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem ArraySynchronization > Completed
CIM > System > RAID > RAID Migration
Detected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemMigration > Detected
CIM > System > RAID > RAID Migration Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemMigration > Failed
CIM > System > RAID > RAID Migration
Complete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemMigration > Completed
CIM > System > RAID > RAID Compression
Detected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompression > Detected
CIM > System > RAID > RAID Compression Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompression > Failed
CIM > System > RAID > RAID Compression
Complete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompression > Completed
CIM > System > RAID > RAID Decompression
Detected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemDecompression > Detected
Trang 20Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID Decompression
Fail
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemDecompression > Failed
CIM > System > RAID > RAID DecompressionComplete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemDecompression > Completed
CIM > System > RAID > RAID FlashCopy®
Detected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemFlashCopy > Detected
CIM > System > RAID > RAID FlashCopy Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemFlashCopy > Failed
CIM > System > RAID > RAID FlashCopyComplete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemFlashCopy > Completed
CIM > System > RAID > RAID CompactionDetected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompaction > Detected
CIM > System > RAID > RAID Compaction Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompaction > Failed
CIM > System > RAID > RAID CompactionComplete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCompaction > Completed
CIM > System > RAID > RAID ExpansionDetected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemExpansion > Detected
CIM > System > RAID > RAID Expansion Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemExpansion > Failed
CIM > System > RAID > RAID ExpansionComplete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemExpansion > Completed
CIM > System > RAID > RAID CopybackDetected
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCopyback > Detected
CIM > System > RAID > RAID Copyback Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCopyback > Failed
CIM > System > RAID > RAID CopybackComplete
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemCopyback > Completed
Trang 21Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID Init Detected Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemInitialization > Detected
CIM > System > RAID > RAID Init Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemInitialization > Failed
CIM > System > RAID > RAID Init Complete Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID SubsystemInitialization > Completed
v CIM > System > RAID > RAID Defunct Drive
v CIM > System > RAID > RAID Defunct Drive
FRU
Managed Resource > Managed System Resource >Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem DefunctDrive > Detected
CIM > System > RAID > RAID Defunct Replaced Managed Resource > Managed System Resource >
Logical Resource > Logical Device > StorageExtent > Logical Disk > RAID Subsystem DefunctDrive > Replaced
v CIM > System > RAID > RAID Dead Battery
v CIM > System > RAID > RAID Dead Battery
Cache
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Battery >Operational Condition > Failed
CIM > System > RAID > RAID Controller Battery
Overtemp
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Battery >Temperature > High
CIM > System > RAID > RAID Controller Battery
Temp Normal
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Battery >Temperature > Normal
CIM > System > RAID > RAID Enclosure Fan
Removed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan > RAIDSubsystem Life Cycle > Removed
CIM > System > RAID > RAID Enclosure Fan
Installed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan > RAIDSubsystem Life Cycle > Added
CIM > System > RAID > RAID Enclosure Fan Fail Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Fan > RAIDSubsystem Operational Condition > FailedCIM > System > RAID > RAID Enclosure Fan OK Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Fan > RAIDSubsystem Operational Condition > OKCIM > System > RAID > RAID Enclosure Temp
Fail
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Sensor >Numeric Sensor > Temperature Sensor > HighCIM > System > RAID > RAID Enclosure Temp
OK
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Sensor >Numeric Sensor > Temperature Sensor > NormalCIM > System > RAID > RAID Enclosure Power
Supply Removed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > RAID Subsystem Life Cycle > RemovedCIM > System > RAID > RAID Enclosure Power
Supply Installed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > RAID Subsystem Life Cycle > Added
Trang 22Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > RAID > RAID Enclosure Power
Supply Fail
Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > RAID Subsystem Operational Condition
> FailedCIM > System > RAID > RAID Enclosure Power
Supply OK
Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > RAID Subsystem Operational Condition
> OKMPA > Unknown Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Unknown > Unknown
MPA > Component > Chassis > Configuration Managed Resource > Managed System Resource >
Physical Resource > Physical Package > PhysicalFrame > Chassis > Operational Condition >Configuration Error
v MPA > Component > Chassis > MaximumCooling
v MPA > Component > Chassis > Failed
v MPA > Component > Chassis > CoolingCapacity
Managed Resource > Managed System Resource >Physical Resource > Physical Package > PhysicalFrame > Chassis > Operational Condition >Temperature
MPA > Component > Bus > Communication Managed Resource > Managed System Resource >
Physical Resource > Physical Package > PhysicalFrame > Chassis > Operational Condition > BusCommunication Failure
MPA > Component > Chassis > Direct SerialAttach Module > Disabled
Managed Resource > Managed System Resource >Physical Resource > Physical Package > PhysicalFrame > Chassis > Open Fabric Manager >Deactivated
MPA > Component > Blade Server > Removed Managed Resource > Managed System Resource >
Physical Resource > Physical Connector > Slot >Life Cycle > Removed
MPA > Component > Blade Server > Inserted Managed Resource > Managed System Resource >
Physical Resource > Physical Connector > Slot >Life Cycle > Added
MPA > Component > Blade Server > Incompatible Managed Resource > Managed System Resource >
Physical Resource > Physical Connector > Slot >Operational Condition > Configuration Error
v MPA > Component > Blade Server >
MPA > Component > Blade Server > VPD Managed Resource > Managed System Resource >
Physical Resource > Physical Connector > Slot >Operational Condition > Not RecognizedMPA > Component > Blade Server > Throttled Managed Resource > Managed System Resource >
Physical Resource > Physical Connector > Slot >Operational Condition > Throttled
MPA > Component > Blade Server >
Communication
Managed Resource > Managed System Resource >Physical Resource > Physical Connector > Slot >Operational Condition > Communication ErrorMPA > Component > Blade Server > Capacity on
Demand
Managed Resource > Managed System Resource >Physical Resource > Physical Connector > Slot >Capacity On Demand > Activated
Trang 23Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Service Processor >
Removed
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor > LifeCycle > Removed
MPA > Component > Service Processor > Inserted Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Hardware Control Point > Service Processor > LifeCycle > Added
MPA > Component > Service Processor >
Network Stack
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Network Stack StartedMPA > Component > Service Processor > Restart Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Restarted
v MPA > Component > Service Processor >
MPA > Component > Service Processor >
Communication
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Blade Server BaseboardManagement Controller (BMC) CommunicationError
v MPA > Component > Service Processor >
Failover
v MPA > Component > Service Processor > Active
v MPA > Component > Service Processor >
Inactive
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Failover
MPA > Component > Service Processor >
Redundancy
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > RedundancyMPA > Component > Service Processor > Test Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Operational Condition > Test
v CIM > System > IPMI Log
v MPA > Component > Service Processor > Log
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Hardware Log > Threshold
MPA > Component > Service Processor >
Out-of-Band > Enabled
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Out-Of-Band Connection > ActivatedMPA > Component > Service Processor >
Out-of-Band > Disabled
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Out-Of-Band Connection > Deactivated
Trang 24Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Service Processor >
Out-of-Band > Port
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Out-Of-Band Connection > Port ChangedMPA > Component > Service Processor > Secure
Out-of-Band > Enabled
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Secure Out-Of-Band Connection > ActivatedMPA > Component > Service Processor > Secure
Out-of-Band > Disabled
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Secure Out-Of-Band Connection > DeactivatedMPA > Component > Service Processor > Secure
Out-of-Band > Port
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >Secure Out-Of-Band Connection > Port ChangedMPA > Component > Service Processor > User
Account > Inactive
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >User Account > Deactivated
MPA > Component > Service Processor > UserAccount > Active
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >User Account > Activated
MPA > Component > Service Processor >
Password > Change Required
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Hardware Control Point > Service Processor >User Account > Password Change RequiredCIM > System > System Enclosure Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > IntrusionMPA > Component > Server > Configuration Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > ConfigurationError
CIM > System > Automatic Server Restart Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > AutomaticServer Restart
MPA > Component > Server Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > Reset
MPA > Component > Server > Power > Disabled Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > Power DisabledMPA > Component > Server > Power > Disabled Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > Power EnabledMPA > Component > Server > Power > Hibernate Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > HibernateMPA > Component > Server > Power > Standby Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > Standby
Trang 25Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Server > Power > Restart Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > RestartedMPA > Component > Server > Power > Off Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > Powered OffMPA > Component > Server > Power > On Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > Powered OnMPA > Component > Server > State Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > State ChangeMPA > Component > BIOS > Corrupted Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > BIOS CorruptedMPA > Component > BIOS > Fault Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > BIOS FaultMPA > Component > SMP Expansion Module >
Disabled
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Server > Operational Condition > SMP ExpansionModule Disabled
v CIM > System > PFA
v MPA > Component > PFA
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Server > Operational Condition > PredictiveFailure Analysis (PFA)
CIM > System > Error Log Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Operational Condition > Log
MPA > Server Watchdog > Boot Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Deployment > Boot Failure
MPA > Server Watchdog > POST Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Deployment > POST Failure
MPA > Server Watchdog > OS Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Deployment > FailedOs
MPA > Server Watchdog > Loader Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Deployment > Load Failure
MPA > Platform Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Scalable Partition > Alerts
MPA > Platform Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Scalable Partition > Logical PartitionState Change
MPA > Platform Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Scalable Partition > Physical PartitionMode Change
CIM > System > Lease Expiration Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Asset > Lease Expired
Trang 26Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > Warranty Expiration Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Server > Asset > Warranty Expired
MPA > Component > Multiplexer ExpansionModule > Removed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Multiplexer Card Module > Life Cycle
> RemovedMPA > Component > Multiplexer Expansion
Module > Inserted
Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Multiplexer Card Module > Life Cycle
> AddedMPA > Component > Multiplexer Expansion
Module > Failed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Multiplexer Card Module > OperationalCondition > Failed
MPA > Component > Alarm Panel > Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Alarm Panel Module > Life Cycle >Removed
MPA > Component > Alarm Panel > Inserted Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Alarm Panel Module > Life Cycle >Added
MPA > Component > Alarm Panel > Power > Off Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Alarm Panel Module > Power > OffMPA > Component > Alarm Panel > Power > On Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Alarm Panel Module > Power > OnMPA > Component > Clock Module > Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Clock Module > Life Cycle > RemovedMPA > Component > Clock Module > Inserted Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Clock Module > Life Cycle > AddedMPA > Component > Clock Module > Power >
Off
Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Clock Module > Power > OffMPA > Component > Clock Module > Power >
On
Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Clock Module > Power > OnMPA > Component > I/O Interposer > Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Input/Output (I/O) Module > LifeCycle > Removed
MPA > Component > I/O Interposer > Inserted Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Input/Output (I/O) Module > LifeCycle > Added
MPA > Component > Chassis > Direct SerialAttach Module > Removed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Baggage Cart Module > Life Cycle >Removed
Trang 27Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Chassis > Direct Serial
Attach Module > Inserted
Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Baggage Cart Module > Life Cycle >Added
MPA > Component > VRM > Configuration Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Voltage Regulator Module (VRM) >Configuration > Change
MPA > Component > VRM > Failed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Voltage Regulator Module (VRM) >Operational Condition > Failed
MPA > Component > Media Tray > Failed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Media Tray Module > OperationalCondition > Failed
MPA > Component > Media Tray > Temperature
Unavailable
Managed Resource > Managed System Resource >Logical Resource > Logical Device > LogicalModule > Media Tray Module > Temperature >Not Available
MPA > Component > Concurrent KVM > Failed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Keyboard, Video, Mouse (KVM)Module > Operational Condition > FailedMPA > Component > Front Panel > Failed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > LogicalModule > Front Panel Module > OperationalCondition > Failed
CIM > System > Processor Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Processor >Life Cycle > Removed
CIM > System > Processor Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Processor >Life Cycle > Added
v MPA > Component > CPU > Configuration
v MPA > Component > CPU > Absent
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Processor >Operational Condition > Configuration ErrorMPA > Component > CPU > Failed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Processor >Operational Condition > Failed
CIM > System > Processor PFA Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Processor >Operational Condition > Predictive FailureAnalysis (PFA)
MPA > Component > I/O Module > Removed Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Switch > Life Cycle > Removed
MPA > Component > I/O Module > Inserted Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Switch > Life Cycle > Added
v MPA > Component > I/O Module > Power >
Trang 28Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > I/O Module > Power > On Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Switch > Power > On
MPA > Component > I/O Module >
Configuration
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > ConfigurationChange
MPA > Component > I/O Module > Mismatch Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Switch > Operational Condition > ConfigurationError
MPA > Component > I/O Module > Power >
Disabled
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > Not Recognized
v MPA > Component > I/O Module > InsufficientPower
v MPA > Component > I/O Module > Fuse
v MPA > Component > I/O Module > OverCurrent®
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > Power StateChanged
v MPA > Component > I/O Module > Failed
v MPA > Component > I/O Module > POST
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > FailedMPA > Component > I/O Module > Redundancy Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Switch > Operational Condition > Redundancy
v MPA > Component > I/O Module > Stacking >
MPA > Component > I/O Module > Zoning Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Switch > Operational Condition > ZoningMPA > Component > I/O Module >
Communication
Managed Resource > Managed System Resource >Logical Resource > System > Computer System >Switch > Operational Condition > CommunicationError
v MPA > Component > Fan > Removed
v MPA > Component > Fan Pack > Removed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan > LifeCycle > Removed
v MPA > Component > Fan > Inserted
v MPA > Component > Fan Pack > Inserted
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan > LifeCycle > Added
MPA > Component > Fan > Configuration Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Fan >Operational Condition > Configuration ErrorCIM > System > Fan Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Fan >Operational Condition > Threshold
v MPA > Component > Fan > Failed
v MPA > Component > Fan Pack > Failed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan >Operational Condition > Failed
Trang 29Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree
v MPA > Component > Fan > PFA
v MPA > Component > Fan Pack > PFA
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Fan >Operational Condition > Predictive FailureAnalysis (PFA)
MPA > Component > DASD > Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Life Cycle > RemovedMPA > Component > DASD > Inserted Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Life Cycle > AddedMPA > Component > DASD > Configuration Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Operational Condition >Configuration Error
v CIM > System > DASD Backplane
v CIM > System > SMART Drive
v MPA > Component > DASD > Failed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Operational Condition >Failed
MPA > Component > DASD > PFA Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Operational Condition >Predictive Failure Analysis (PFA)
CIM > System > Disk Space Low Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Media AccessDevice > Disk Drive > Available Percentage >Disk Space
MPA > Component > Power Supply > Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > PowerSupply > Life Cycle > Removed
MPA > Component > Power Supply > Inserted Managed Resource > Managed System Resource >
Logical Resource > Logical Device > PowerSupply > Life Cycle > Added
v MPA > Component > Power Supply >
Configuration
v MPA > Component > Power Supply > Absent
Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > Operational Condition > ConfigurationError
v CIM > System > Power Supply
v MPA > Component > Power Supply > Failed
Managed Resource > Managed System Resource >Logical Resource > Logical Device > PowerSupply > Operational Condition > FailedMPA > Component > Power Supply > PFA Managed Resource > Managed System Resource >
Logical Resource > Logical Device > PowerSupply > Operational Condition > PredictiveFailure Analysis (PFA)
CIM > System > Memory Managed Resource > Managed System Resource >
Physical Resource > Physical Component > Chip
> Physical Memory > Life Cycle > RemovedCIM > System > Memory Managed Resource > Managed System Resource >
Physical Resource > Physical Component > Chip
> Physical Memory > Life Cycle > AddedMPA > Component > DIMM > Absent Managed Resource > Managed System Resource >
Physical Resource > Physical Component > Chip
> Physical Memory > Operational Condition >Configuration Error
Trang 30Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.CIM > System > Memory PFA Managed Resource > Managed System Resource >
Physical Resource > Physical Component > Chip
> Physical Memory > Operational Condition >Predictive Failure Analysis (PFA)
MPA > Component > DIMM > Failed Managed Resource > Managed System Resource >
Physical Resource > Physical Component > Chip
> Physical Memory > Operational Condition >Failed
MPA > Component > DIMM > Disabled Managed Resource > Managed System Resource >
Physical Resource > Physical Component > Chip
> Physical Memory > Operational Condition >Deactivated
MPA > Component > Management ModuleInterposer > Removed
Managed Resource > Managed System Resource >Physical Resource > Physical Connector >ManagementModule > Life Cycle > RemovedMPA > Component > Management Module
Interposer > Inserted
Managed Resource > Managed System Resource >Physical Resource > Physical Connector >ManagementModule > Life Cycle > AddedMPA > Component > Battery > Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Battery > LifeCycle > Removed
MPA > Component > Battery > Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Battery > LifeCycle > Added
MPA > Component > Battery > Unreliable Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Battery >Operational Condition > Not ReliableMPA > Component > Battery > Failed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Battery >Operational Condition > Failed
MPA > Component > RAID > Failed Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >RAID Controller > Operational Condition > FailedMPA > Component > Storage Module > Removed Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Storage Subsystem > Life Cycle > RemovedMPA > Component > Storage Module > Inserted Managed Resource > Managed System Resource >
Logical Resource > System > Computer System >Storage Subsystem > Life Cycle > Added
v MPA > Component > Storage Module > Failed
v MPA > Component > Storage Module >
MPA > Component > USB > Removed Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Controller >USB Controller > Life Cycle > RemovedMPA > Component > USB > Inserted Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Controller >USB Controller > Life Cycle > Added
MPA > Component > USB > Over Current Managed Resource > Managed System Resource >
Logical Resource > Logical Device > Controller >USB Controller > Operational Condition > OverCurrent
Trang 31Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree.MPA > Component > Power Subsystem > Over
Power
Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Power Exceeded
MPA > Component > Power Subsystem > Over
Current
Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Over Current
MPA > Component > Power Subsystem > Low
Fuel
Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Low Fuel
MPA > Component > Power Subsystem > Over
Subscription
Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Over Power SubscriptionMPA > Component > Power Subsystem >
Mismatched Power Supplies
Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Configuration ErrorMPA > Component > Power Subsystem >
Redundancy
Managed Resource > Managed System Resource >Logical Resource > System > AdministrationDomain > Power Domain > OperationalCondition > Redundancy
CIM > System > Network Adapter Managed Resource > Managed System Resource >
Physical Resource > Physical Package > Card >Life Cycle > Network interface card (NIC)Removed
CIM > System > Network Adapter Managed Resource > Managed System Resource >
Physical Resource > Physical Package > Card >Life Cycle > Network interface card (NIC) AddedCIM > System > Network Adapter Managed Resource > Managed System Resource >
Physical Resource > Physical Package > Card >Operational Condition > Network interface card(NIC) Offline
CIM > System > Network Adapter Managed Resource > Managed System Resource >
Physical Resource > Physical Package > Card >Operational Condition > Network interface card(NIC) Online
CIM > System > Network Adapter Managed Resource > Managed System Resource >
Physical Resource > Physical Package > Card >Operational Condition > Network interface card(NIC) Failed
MPA > Component > I/O Board > Failed Managed Resource > Managed System Resource >
Physical Resource > Physical Package > Card >Operational Condition > I/O Board FailureMPA > Component > Processor Board > Failed Managed Resource > Managed System Resource >
Physical Resource > Physical Package > Card >Operational Condition > Processor Board FailureMPA > Component > Expansion Card > Failed Managed Resource > Managed System Resource >
Physical Resource > Physical Package > Card >Operational Condition > Daughter Card Failure
Trang 32Table 2 Hardware-platform events cross reference (continued)
IBM Director 5.20 event name
IBM Systems Director 6.1 event name Note:The name shown also is the click path toview this event in the Event Filter Builder tree
v CIM > System > Redundant Network AdapterFailover
v CIM > System > Redundant Network AdapterSwitchBack
v CIM > System > Redundant Network AdapterSwitchOver
Managed Resource > Managed System Resource >Physical Resource > Physical Package > Card >Operational Condition > Network interface card(NIC) Failover
MPA > Component > Blade Expansion Unit >
Failed
Managed Resource > Managed System Resource >Physical Resource > Physical Package > BladeExpansion Unit > Operational Condition > BladeExpansion Unit Failed
v CIM > System > Voltage
v MPA > Environmental > Voltage
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Sensor >Numeric Sensor > Voltage Sensor > Out Of Range
v CIM > System > Temperature
v MPA > Environmental > Temperature
Managed Resource > Managed System Resource >Logical Resource > Logical Device > Sensor >Numeric Sensor > Temperature Sensor > High
IBM BladeCenter and System x platform-specific events
The events listed in this section are specific for the IBM BladeCenter and System x hardware platforms In IBM Director 5.20, these were called the CIM and MPA events In IBM Systems Director 6.1, the CIM and MPA events are still used, but are mapped to hardware component categories Use the Hardware-platform event cross-reference table to find the 5.20 event name and its equivalent 6.1 event name.
If you select the CIM check box in the Event Filter Builder tree, the event filter will
process all of the event types that are specified in the CIM subtree.
Event type Event text Severity Category Extended details
applicable
Notapplicable
None
CIM > System
The System events occur when a change in the state of a Platform Agent managed system or Common Agent managed system managed system is detected These events also occur when a change in the state of a Hardware Management Console (HMC) is detected.
Details
The CIM > System event types use a standard set of extended details.
Trang 33If you select the System check box in the Event Filter Builder tree, the event filter
will process all of the event types that are specified in the System subtree.
Event type Event text Severity Category Extended details
applicable
Notapplicable
None
CIM > System > Automatic Server Restart:
The Automatic Server Restart event occurs when the operating system locks up and no longer responds Subsequently, a system restart (reboot) begins This event
is supported on servers with Intelligent Platform Management Interface (IPMI).
AutomaticServer Restart
The last system restart was due to theautomatic server restart hardware
AutomaticServer Restart
The last system restart was not due tothe automatic server restart hardware
Informational Resolution None
CIM > System > DASD Backplane:
The DASD Backplane event occurs when the Remote Supervisor Adapter detects that the state of the system hard disk drive changes with respect to its availability.
DASDBackplane
Drive drive has reported a fault This
event must be cleared manually
where drive is the affected hard disk
drive
Critical Alert None
CIM > System > Disk Space Low:
The Disk Space Low event occurs when the state of system hard disk drive space changes with respect to user-defined levels of hard disk drive space remaining By default, the warning level is 5% remaining and critical level is 3% remaining.
Trang 34v If the severity is Critical or Warning: Remove files from the specified hard disk
or lower the minimum threshold.
v If the category is Resolution: The error has been resolved This event is informative only.
Details
Event type Event text Severity Category
Additional extended details
Disk Space Low Logical drive name fell below threshold
of threshold MB The current value is
value MB.
where:
v name is the affected logical drive.
v threshold is the critical threshold
value
v value is the amount of current disk
space available
Critical Alert None
Disk Space Low Logical drive name fell below threshold
of threshold MB The current value is
value MB.
where:
v name is the affected logical drive.
v threshold is the warning threshold
value
v value is the amount of current disk
space available
Disk Space Low Logical drive name free space is normal.
The current value is value MB.
where name is the affected logical drive and value is the amount of current disk
space available
Informational Resolution None
Disk Space Low Logical drive name status could not be
determined
where name is the affected logical drive.
Unknown Resolution None
CIM > System > Error Log:
The Error Log event occurs when the Remote Supervisor Adapter detects that its error log is at 75% or 100% of its capacity.
Trang 35Event type Event text Severity Category
Additional extended details
Error Log The system management processor error
log is 75% full This event must becleared manually
Warning Alert None
Error Log The system management processor error
log is full This event must be clearedmanually
Warning Alert None
CIM > System > Fan:
The Fan event occurs when the state of a system fan has changed with respect to the manufacturer-defined revolutions per minute (rpm) values This event is sent when a fan stops, is removed, or is not performing optimally.
Resolution
v If the severity is Critical: Replace the specified fan that has failed.
v If the category is Resolution: The error has been resolved This event is
informative only.
Details
Event type Event text Severity Category
Additional extended details
Fan Fan Sensor number fell below threshold
of threshold rpm The current value is
speed rpm.
where:
v number is the affected fan sensor.
v threshold is the critical fan threshold
value
v speed is the current fan speed.
Note:This event must be clearedmanually
Critical Alert None
Fan Fan Sensor number reports normal.
where number is the affected fan sensor.
Informational Resolution None
CIM > System > Host Bus Adapter:
The Host Bus Adapter events occur when a QLogic Fibre Channel Host Bus
Adapter detects a change in its state or configuration.
Trang 36CIM > System > IP Change:
The IP Change event occurs when a change in an IP address used by the HMC is detected.
Resolution
No resolution This event is informative only.
Details
The CIM > System event types for HMC use a standard set of extended details.
Event type Event text Severity Category Additional extended details
IP Change The IP Address associated with HMC number
has changed
where number identifies the HMC.
Informational Alert v Description indicates the
type of event
v OldIPAddress indicates the
previous IP address used
by the HMC
v NewIPAddress indicates the
new IP address used bythe HMC
CIM > System > IVM Unconfigured:
The IVM Unconfigured event occurs when an IVM becomes unconfigured.
Typically, this occurs when a user migrates an IVM-managed system to HMC management.
Resolution
No resolution This event is informative only.
Details
The CIM > System event types for HMC use a standard set of extended details.
Event type Event text Severity Category Additional extended details
IVM Unconfigured IVM is not configured Informational Alert None
CIM > System > IPMI Log:
The IPMI Log event occurs when the system-management processor error log is 75% full or full This event is supported on servers with Intelligent Platform Management Interface (IPMI).
Resolution
To correct this problem, reduce the number of events in the event log You can clear the event log using the BIOS configuration utility on the server or remotely using the OSA SMBridge utility See the documentation for your server or the IBM
Redbooks publication IBM eServer™xSeries® and BladeCenter Server Management
(SG24-6495).
Trang 37Event type Event text Severity Category
Additional extended details
IPMI Log The system management processor error
log is 75% full This event must becleared manually
Warning Alert None
IPMI Log The system management processor error
log is full This event must be clearedmanually
Warning Alert None
CIM > System > Lease Expiration:
The Lease Expiration event occurs when the system lease expiration date has been reached with respect to the value configured for the date in the Asset ID task.
Resolution
v If the severity is Warning: The lease has expired.
v If the category is Resolution: The error has been resolved This event is informative only.
Details
The date value is provided by the Asset ID task The Lease page in the Asset ID
task includes the End Date field where you can set the lease expiration date The
date is stored in the IBMPSG_Lease.LeaseEndDate CIM property that is monitored
at regular poll intervals A CIM indication is generated when the system CIMOM starts and when a state change is detected relative to the internal poll interval.
Event type Event text Severity Category Additional extended details
Lease Expiration The lease on system has expired It expired
on date.
where system is the affected system and date
is the lease expiration date
Lease Expiration The lease on system is normal It will expire
on date.
where system is the affected system and date
is the lease expiration date
Informational Resolution None
CIM > System > Life Cycle:
The Life Cycle event occurs when an LPAR is created or deleted on a system managed by the Hardware Management Console (HMC) The event also occurs when a CEC is managed by the HMC or removed from management by the HMC.
Resolution
No resolution This event is informative only.
Trang 38The CIM > System event types for HMC use a standard set of extended details.
Additional extended details
Life Cycle LPAR name has been created.
where name identifies the LPAR created.
Minor Alert LifeCycleEvent indicates
whether the CEC wasadded or removed frommanagement by the HMC.Life Cycle LPAR name has been deleted.
where name identifies the deleted LPAR.
Minor Alert LifeCycleEvent indicates
whether the CEC wasadded or removed frommanagement by the HMC.Life Cycle CEC cec is now managed by HMC hmc.
where cec identifies the CEC and hmc identifies the
HMC
Minor Alert LifeCycleEvent indicates
whether the CEC wasadded or removed frommanagement by the HMC.Life Cycle CEC cec is no longer managed by HMC hmc.
where cec identifies the CEC and hmc identifies the
HMC
Minor Alert LifeCycleEvent indicates
whether the CEC wasadded or removed frommanagement by the HMC
CIM > System > Memory:
The Memory event occurs when the currently available memory in a system changes with respect to availability due to a modification during a system shut down.
Event type Event text Severity Category Additional extended details
Memory Memory configuration reduced from
previous MB to current MB.
where previous is the previous memory size and current is the current memory size.
Memory Memory configuration increased from
previous MB to current MB.
where previous is the previous memory size and current is the current memory size.
Informational Resolution None
CIM > System > Memory PFA:
The Memory PFA event occurs when a dual inline memory module (DIMM) in a system is about to fail.
Resolution
v If the severity is Critical: Replace the specified DIMM that is failing or has failed.
Trang 39v If the category is Resolution: The error has been resolved This event is informative only.
Details
Event type Event text Severity Category Additional extended details
Memory PFA Memory device identified as memory in
bank slot is predicting an imminent failure.
where slot is the affected memory slot.
Memory PFA Memory device identified as memory in
bank slot is not predicting a failure.
where slot is the affected memory slot.
Informational Resolution None
CIM > System > Network Adapter:
The Network Adapter events occur when a network interface card (NIC) in a system fails, goes offline, or goes online.
Resolution
v If the severity is Critical or Minor: Replace the specified NIC that has failed.
v If the category is Resolution: The error has been resolved This event is informative only.
Details
If you select the Network Adapter check box in the Event Filter Builder tree, the
event filter will process all of the event types that are specified in the Network Adapter subtree.
Additional extended details
applicable
Notapplicable
v DeviceID is the ID for
the component if thereare more than one of thesame component andyou are trying to fix aparticular instance
v Resolution provides
information that canhelp resolve a hardwareproblem in the server
You can choose to select specific event types that are displayed under the Network Adapter node in the Event Filter Builder tree The event filter will process only the event types that you select.
Trang 40Event type Event text Severity Category Additional extended details
Failed The network adapter failed Critical Alert v DeviceID is the ID for the
component if there aremore than one of the samecomponent and you aretrying to fix a particularinstance
v Resolution provides
information that can helpresolve a hardwareproblem in the server.Offline The network adapter is offline Minor Alert v DeviceID is the ID for the
component if there aremore than one of the samecomponent and you aretrying to fix a particularinstance
v Resolution provides
information that can helpresolve a hardwareproblem in the server.Online The network adapter is online Informational Resolution v DeviceID is the ID for the
component if there aremore than one of the samecomponent and you aretrying to fix a particularinstance
v Resolution provides
information that can helpresolve a hardwareproblem in the server
CIM > System > PFA:
The PFA event occurs when the Remote Supervisor Adapter detects that a component in a system is about to fail.
PFA Predictive Failure Detected Please check
the system management processor errorlog for more information This eventmust be cleared manually
Critical Alert None
CIM > System > Power State:
The Power State event occurs when a change in the power state of a CEC or LPAR
is detected.