Trang 1ALCATEL BSS A9120 BSC With Multipair Cables
Extension Manual
3BK 17186 0002 RJZZA Ed.05
Trang 2Status RELEASEDShort title INS
All rights reserved Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel/Evolium
BLANK PAGE BREAK
Trang 3Contents
Preface 5
1 General Information 7
1.1 Hardware Description 8
1.1.1 General Information 8
1.1.2 Racks Configuration 9
1.1.3 Weight and Dimensions 10
1.2 Restrictions 10
1.3 Prerequisite 10
1.4 Initial State 10
1.5 Final State 10
1.6 Operating Principle 11
1.7 Time Schedule 12
1.8 Information Required 12
2 Preliminary Checks 13
2.1 Before Leaving for the Site 14
2.2 Before Starting (on Arrival at the Site) 14
3 Racks Installation 15
3.1 Rack Delivery 16
3.2 Mechanical Assembling 18
3.2.1 Preparing the Rack Already in Operation 18
3.2.2 Racks Positioning 20
3.2.3 Racks Assembling 21
3.2.4 Top Structures Fitting 22
3.2.5 Right Side Panel Installation 22
3.2.6 Horizontal Cable Way Installation 23
4 Inter-Rack Cabling 25
5 PCM Cables Installation 29
5.1 Cable Installation in the Cable Way 30
5.2 Cable Routing at Back of Rack 30
5.3 Connecting to the Extension Racks 31
5.4 PCM Cable Testing 34
6 Power Cables Connecting 35
6.1 Option: Case of 2-Wire Power System 36
6.2 Case of 3-Wire Power System Connection (Standard Installation) 39
6.3 Test the Power Supply 41
7 Finishing Installation 43
7.1 Mechanical Assembly Finishing 44
7.2 Finishing 46
Appendix A : Abbreviations 47
Appendix B : List of Items Required 49
Trang 4Contents
Trang 5Preface
Purpose This document describes how to extend on site a A9120 BSC with mutipair
cables of ALCATEL BSS (one or two racks)
Audience This document is intended for:
InstallersSite administratorsSupervisorsProject managersField service techniciansOccasional users
Assumed Knowledge You must have a basic understanding of the following:
Basic knowledge of Alcatel BSS equipmentExperience of electrical mounting and cabling
Trang 6Preface
Trang 7PrerequisiteInitial StateFinal StateTime ScheduleInformation Required
Trang 9G S 2
1 /7
D D
CC
S
WC
H
G S 2 2/0
S
WC
H
G S 2 2/1
S
WC
H
G S 2 2/2
S
WC
H
G S2 2/3
S
WC
H
G S 2 2/4
S
WC
H
G S2 2/5
S
WC
H
G S2 2/6
S
WC
H
G S 2
2 /7
D D
CC
S
WC
H
G S 2 3/0
S
WC
H
G S2 3/1
S
WC
H
G S 2 3/2
S
WC
H
G S2 3/4
S
WC
H
G S 2 3/5
S
WC
H
G S 2 3/6
S
WC
H
G S2 3/7
D D
CC
H
AS 6
D T
CC
02 0
D T
CC021
S
WC
H
AS 3
S
WC
H
A S 7
D T
CC
0 30
D T
CC
034 035 03 6 037 Q A
7
T T T T
D D C
C
T C U
C
01 0
C U
C
01 1
C U
C
01 2
C U
C
01 3
C U C U
I U A
Q A 2
H
G S 2 0/0
S
WC
H
G S 2 0/1
S
WC
H
G S 2 0/2
S
WC
H
G S 2 0/3
S
WC
H
G S 2 0/4
S
WC
H
G S 2 0/5
S
WC
H
G S2 0/6
S
WC
H
G S 2 0/7
D D
CC
SAU 01
SAU 02
SAU 03
SAU 04
SAU 05
SAU 06
SAU 07
SAU 08
G S 1 0/5
S
W
C H
G S1 0/7
D D
DC converter removed, starting from rack variant 3BK 06796 AAAC
Figure 2: Example of Extension Rack B, C or D (Front View)
Trang 10Before starting the extension:
The racks and installation kits are packed and delivered on siteRack A or Rack A+rack B or Rack A+rack B +rack C are already in operation
1.5 Final State
After finishing the extension:
The extension racks are ready for commissioning
The extension racks are not powered up
All the PCM cables between rack and site DDF must be installed for each rack.The internal cables are installed but not connected to operational racks
Trang 111 General Information
1.6 Operating Principle
Preparation before leaving for the site
Delivery Unpack the equipment
Install the racks on their final locations
Assemble the racks together
Fit the top structure Fit the top rack horizontal cable tray
Fit the inter−rack cables
Run the PCM cables from the racks to the DDF
Connect the PCM cbles
Connect the power supply
Fit the labels, panels, doors
Finish the installation
Trang 12Total for two men
(*1) transportation time to final location depending of the site
Trang 132 Preliminary Checks
2 Preliminary Checks
This chapter describes preparation for the operation in two steps:
Before leaving for the siteBefore starting (On arrival at the site)
Trang 142 Preliminary Checks
2.1 Before Leaving for the Site
Check that prerequisites have been
satisfied
SeePrerequisite (Section 1.3)
Check availability of all Information
Required
SeeInformation Required (Section 1.8)
Check availability of documentation SeeDocuments Required (in appendix B); check the
edition and release of the documents
Check availability of tools SeeTools Required (in appendix B); refer to the “Tools
catalogue“ for checking the contentCheck calibration label when asked
Check availability of supplies SeeConsumable Supplies (in appendix B)
2.2 Before Starting (on Arrival at the Site)
Check applicable notifications and
Check that the safety instructions have
been applied
Refer to “General Wiring Handbook” to check that thesafety precautions have been taken in accordance withthe safety instructions
Read instructions in the event of anomaly Refer to “General Wiring Handbook” for instructions
Fill in premises inspection form Refer to “BSS site premises inspection, post handover” and
complete “Premise inspection form” (CEL)
Fill in completion check list Complete the header field of the “Completion Check List”
See “Tools catalogue“ and note measurementThe CCL is to be completed as each instruction is carriedout
Check the antistatic wrist strap Check that the resistance of the antistatic wrist strap is
greater then 1 Mohm and connect it to the rack’s earth
Check availability of Alcatel kits SeeInstallation Kits (in appendix B)
Trang 153 Racks Installation
3 Racks Installation
This chapter describes how to :Move the racks to their final locationsUnpack the racks
Prepare the racks already in operationPosition the racks
Level the racksAssemble the racks togetherAssemble the horizontal cable way
The extension rack must be assembled with operating racks
Before making mechanical installation or connection, ensure that the generalsafety instructions are applied (see General Wiring Handbook)
Trang 163 Racks Installation
3.1 Rack Delivery
Figure 3: Crane Transportation or Pallet Transportation
Procedure 1 Check the number of packages.
2 Report any damages on the carrier’s delivery note.
3 Unpack the equipment.
4 Inspect the racks for cracks, scratches, damages to boards
5 Check the serial number
6 Complete the CCL
Trang 173 Racks Installation
Figure 4: Unpacking the Rack, then Checking the Serial Number
Trang 183 Racks Installation
3.2 Mechanical Assembling
3.2.1 Preparing the Rack Already in Operation
12 12 12
Figure 5: Horizontal Cable Tray (Example on normal floor with site cable tray)
Trang 193 Racks Installation
Figure 6: Lateral Panel and Its Supports
Procedure 1 Remove the screws between horizontal cable tray and right support (see
Figure5)
2 Remove the right side panel (2 in Figure6)
3 Remove the two rack top earthing brackets (1 in Figure6)
4 Remove the three lateral panel supports ( Figure6)
Trang 203 Racks Installation
3.2.2 Racks Positioning
Procedure 1 Move the racks to their final location.
Figure 7: Moving the Rack
2 Position the racks in order A, B, C, D.
Rack A Rack A Rack C
C
Rack D
Trang 213 Racks Installation
Figure 9: Leveling Feet
3.2.3 Racks Assembling
Figure 10: Assembling the Racks
Procedure 1 Assemble the racks together without tightening the screw (1 in Figure10)
2 Insert the spacers (detail) on the screws between the rack (3 in Figure).
3 Insert the bottom contact rails (2 in Figure).
4 Tighten slightly the screws.
5 Fit the bottom contact cover plates (using M6 self theading screws)
Trang 223 Racks Installation
3.2.4 Top Structures Fitting
Figure 11: Top Structure
1 Remove the rear cable clamp from top structure
2 Fix the top structure to the rack (4 screws).
3.2.5 Right Side Panel Installation
Trang 233 Racks Installation
3 Screw the screws 1AD 00007 0146 to the side panel without tightening them.
4 Position the right side panel (2).
5 Tighten the fastening screws.
3.2.6 Horizontal Cable Way Installation
1
2
12 12 12
3
4
Figure 12: Horizontal Cable Way Mounting
5 6
Figure 13: Fish Plate Mounting
Procedure 1 Lay the mounting on (1) the top of right panel (2) See Figure12
2 Fix the pre-cut horizontal cable tray (3) to the mountings.
3 Mount the fish plates (5) and braids between cable trays (6) See Figure13
4 Connect earth braid (4 in Figure12) between structure and horizontalcable tray
Trang 243 Racks Installation
Trang 264 Inter-Rack Cabling
Figure 14: Cabling Between Racks (Rear View)
Example of connection to the rack A, address 03::36BA03:
Trang 274 Inter-Rack Cabling
Procedure 1 Run the inter-connection loom at the rear of the racks.
2 Using addresses indicated on labels, approach the end of cables.
3 Connect the cables to the extension racks.
Do not connect the cables to the rear of operating racks
4 Tie the cables to the racks.
Trang 284 Inter-Rack Cabling
Trang 295 PCM Cables Installation
5 PCM Cables Installation
This chapter describes the procedure to :run the cables in the cable trayconnect cables at the rack sideThe connection to the site DDF is described in document :
“Installation method of DDF for BSS equipment”
Trang 305 PCM Cables Installation
5.1 Cable Installation in the Cable Way
Procedure 1 Install the cables in PCM compartment of cable tray.
2 Attach the cables with plastic tie wraps.
3 Mark cables with a marker.
4 Cut the cables at good lenght.
5 Mark the cable extremities.
5.2 Cable Routing at Back of Rack
Procedure 1 Tie the cables to the first half cable clamp using tie wraps (1 inPicture 1)
2 Run the inter-connection loom at the rear of the extension racks.
3 Tie the cables to the racks.
4 For compatibility with EDGE, the BSC can be delivered with IK 7 or IK 8
top structure In this case, 4 additional multipair cables can be fitted tostructure (seePicture 2)
Trang 315 PCM Cables Installation
5 If not the EDGE case compatibility, use the 4 left and 4 right cable pass cuts
for multipair cable, leaving the the 2 central cutouts free
Figure 16: Positioniong the Cables into the Clamps at Back of Racks Using Different Top Structures
5.3 Connecting to the Extension Racks
To avoid errors, it is necessary to work cable by cable.
Each cable is split in two branches (in Y) Each branch must be labeled.The following figure shows the principle of labeling for each cable split in Y andlabeled near connectors
Trang 325 PCM Cables Installation
Figure 17: Example of Rack A Labels Positionning
1 Connect all pairs of the first cable to the corresponding subracks (see
Table 1)
2 Pass the pairs in the black plastic clamps (seePicture.)
Trang 335 PCM Cables Installation
Trang 345 PCM Cables Installation
5.4 PCM Cable Testing
For this procedure an ohm-meter and a 100-ohm resistor are required Twomen are needed
Figure 18: Case of 120 Ohms Cables
Figure 19: Case of 75 Ohms Cables
Trang 356 Power Cables Connecting
6 Power Cables Connecting
This chapter describes how to:
change power system from 3-wires to 2-wires (option)connect the rack to the existing power bus
Before making and electrical connection, ensure that the safety instructions areapplied (see General Wiring Handbook)
It is essential that :switches of new racks are OFFinstallers works with insulated toolsinstallers works with safety equipment (glasses, gloves )
Trang 366 Power Cables Connecting
6.1 Option: Case of 2-Wire Power System
The standard installation is 3-wire system where 0 volt and GND are separated(-48V / 0V / GND) If needed by customer (option), the rack must be changedfrom 3-wire to 2 wire system
Procedure 1 Remove cable SG/EG - EG TAB filter (3BK 07838 AN - 1 in Figure21)
2 Remove BATRET - BATRET EMA filter (3BK 07836 AN - 2 in Figure21)
3 Remove the filtered BATRET cable (3BK 07844 AP - 3 in Figures21and23)
4 Remove the two earth cables from the vertical frame work (3BK 07839 AR
- 4 in 21and23)
5 Swap the positions of the small cables on the TRU (211 27978 AA - 5
in23and24)
6 Add BATRET EG TAB filter (3BK 07 835 AN - E in Figure22)
7 Install the 17 earth braid jumpers (211 03875 AA):
from 02::17ZA03 to 02::18ZA03from 02::37ZA03 to 02::38ZA03from 02::57ZA03 to 02::58ZA03from 03::02ZA03 to 03::03ZA03from 03::34ZA03 to 03::35ZA03from 04::02ZA03 to 04::03ZA03from 04::29ZA03 to 04::30ZA03from 04::61ZA03 to 04::62ZA03from 06::02ZA03 to 06::03ZA03from 06::34ZA03 to 06::35ZA03from 07::17ZA03 to 07::18ZA03from 07::22ZA03 to 07::23ZA03from 07::49ZA03 to 07::50ZA03from 07::54ZA03 to 07::55ZA03from 08::02ZA03 to 08::03ZA03from 08::41ZA03 to 08::42ZA03from 08::61ZA03 to 08::62ZA03
8 Install the small cable on the TRU (211 27978 AA - H in Figure24)
9 Install the earth cables from EG Tab Filter to the TRU (3BK 07843 AL
-D in Figures22and24)
10 Install the two earth cables to the vertical busbar (211 27975 AA - A and B
in Figure24)
Trang 376 Power Cables Connecting
Trang 386 Power Cables Connecting
Trang 396 Power Cables Connecting
6.2 Case of 3-Wire Power System Connection (Standard
Installation)
6 : cable between rack and clamps
Figure 25: Power Clamp View
Trang 406 Power Cables Connecting
Figure 26: Rack Power Cables
Order of work : GND, since BATRET, since BAT A, since BAT B.
Procedure 1 Remove the first skin of power bus cable
2 Fit the cable clamp to power bus and to cables of top structure (to achieve
good contact, do not remove the conducting grease)
3 Tighten hard the nut (1 in Figure25)
Trang 416 Power Cables Connecting
6.3 Test the Power Supply
1 : BAT B filtered –48V
3 : BAT A filtered –48V
Figure 27: TRU (rear rack)
To test the power supply:
1 Check that rack breakers are “OFF”.
2 At the TRU board of each rack, measure the voltage and the 48 Volts polarity.
Trang 426 Power Cables Connecting
Trang 437 Finishing Installation
7 Finishing Installation
This chapter describes :the finishing of mechanical installationthe labeling of rack
Trang 447 Finishing Installation
7.1 Mechanical Assembly Finishing
Trang 457 Finishing Installation
A =13 mm ; B = 16 mm ; C = 13 mm
To finish the mechanical assembly:
1 Fit the header panels of the rack.
2 Fit the cross member assembly between the racks.
3 Install the front rack upper grid.
4 Fit the second PCM cable gland.
5 Install the rear rack upper grid.
6 Install the doors (pull down the sliding rod).
7 Label the rack (rack B in example).
Trang 467 Finishing Installation
7.2 Finishing
Before leaving the site:
1 Close the doors
2 Clear away packaging
3 Clean the site
4 Leave the rack key to the door.
Trang 48Appendix A : Abbreviations
Trang 49Appendix B : List of Items Required
Appendix B: List of Items Required
Installation Kits The following table is used to check, on site, the mandatory or optional delivery
item kits
The used symbols are:
• mandatory kit
∇technical choice kit
◊customer option kit
• Top structure
∇75 Ohms
∇120 Ohms
IK1IK2
3BK 08772 AA3BK 08772 AB
1/rack1/rack
• Top structure (EDGE compatible)
∇75 Ohms
∇120 Ohms
IK7IK8
3BK 08772 AG3BK 08772 AH
1/rack1/rack
• Inter-rack cable kit
∇between rack A and rack B
∇between rack A and rack B and rack C
CINE 4CINE 6
3BK 06691 AA3BK 06691 AB
11
◊DDF
• DDF 2 meter for 4 x MP24
• Mechanical part for 24 x JS10
• Terminal block 10 pairs
• Label for 24 x JS10
DDFMP24JS10LAB
1AD 02846 00011AD 02843 00011AD 06634 00111AD 02854 0001
11241
1AC 00369 00081AC 00362 0001
rollroll