5/07 • 103742AE Fiber Distributing Cabinets The OMX600® fiber distributing cabinet provides mounting locations for termination, splice and storage panels.. 5/07 • 103742AE Preterminated
Trang 15/07 • 103742AE
Introduction 94
Things to Consider When Ordering 96
Fiber Distributing Cabinets 97
Preterminated Fiber Termination Panels with Pigtails 98
Preterminated Fiber Termination Panels with Multifiber Cable-IFC 99
Adapter-Only Fiber Termination Panels 100
Splice Panels 101
Value-Added Module (VAM) Chassis 102
Jumper Storage Panel 103
Interbay Management Panel 103
Frame Installation Kit 103
End Guard 103
Splice Frame 104
Splice Tray 105
Cable Clamp 105
Standard Cross-Connect Patch Cord Lengths 106
Ordering Information for Patch Cords and Attenuators 106
Trang 25/07 • 103742AE
Introduction
Termination Panel
The OMX600 termination panels are available with 72, 96 or 144 (with LC) adapters These panels can be ordered with adapters only or preterminated with either intrafacility (IFC), outside plant (OSP) cables or pigtails for ease of installation The panels are available with industry-standard connector/adapter styles
Splice Panel
The OMX600 splice panel provides protection and a mounting location for ADC’s round splice trays Each splice panel is two mounting positions tall and holds 24 splice trays Each splice tray can house up to 24 splices
Storage Panel
The storage panel enables storage of fiber-optic jumper slack within an OMX600 frame Each jumper storage module is one module position tall The interbay management panel provides off-frame storage of jumper slack ADC recommends the use of 2.0 mm patch cords to maximize the cable management potential
Value-Added Module (VAM) Chassis
Adding signal management and enhancement functions, such as splitters, couplers and wavelength division mulitplexers, optimizes the value of your fiber network, by providing nonintrusive access to the optical signal for monitoring and testing signal integrity The OMX600 VAM chassis accommodates various splitter and WDM modules
ADC has developed the OMX600® optical distribution frame to meet today‘s network demands Designed with total front access, the OMX600 has five right-hand and five left-hand mounting positions and can be installed back-to-back or against a wall to save valuable office floor space
This high-density frame terminates and splices up to 576 fibers in a
600 mm x 300 mm (23.6" x 11.8") footprint
Product Overview
Limited floor space where versatility is a necessity
Number of fibers, future growth potential
Termination panels 72, 96 and 144 (LC connectors only)
Trang 3
5/07 • 103742AE
Introduction
Configurations
The modular OMX600® product line can be configured to optimize the network All OMX600
configurations listed below are completely front-facing, enabling wall-mount or back-to-back
configurations The OMX600 can be enclosed with lockable front doors and end guards for increased
fiber protection and security
Configuration 1
576 terminations and 576 splices (using the 96-position panel)
432 terminations and 432 splices (using the 72-position panel) 2.14 m x 900 mm x 300 mm (7' x 35.4" x 11.8")
Interconnect or cross-connect solution Includes two off-frame jumper storage panels
Configuration 2
288 terminations and 288 splices (using the 96-position panel)
216 terminations and 216 splices (using the 72-position panel) 2.14 m mm x 600 mm x 300 mm (7' x 23.6" x 11.8") Interconnect solution
On-frame jumper storage
Other configurations are available upon request Please contact ADC Technical Assistance Center
Configuration 4
576 terminations and 288 splices (using the 96-position panel)
432 terminations and 216 splices (using the 72-position panel) 2.14 m x 600 mm x 300 mm (7' x 23.6" x 11.8")
Cross-connect solution On-frame jumper storage
Configuration 3
480 terminations (using the 96-position panel)
360 terminations (using the 72-position panel) 2.14 m x 600 mm x 300 mm (7' x 23.6" x 11.8") Interconnect or cross-connect solution
On-frame jumper storage
Trang 45/07 • 103742AE
Things to Consider When Ordering How to Order
1) Select desired Frame
- Fiber Distributing Cabinet - Page 97 _
2) Select desired Fiber Termination Panels
- Preterminated Fiber Termination Panels with
- Preterminated Fiber Termination Panels with Multifiber Cable-IFC - Page 99 _
- Adapter-Only Fiber Termination Panels - Page 100 _
- Splice Panels - Page 101 _
Optional Equipment
3) Value-Added Module (VAM) Chassis - Page 102 _ 4) Jumper Storage Panel - Page 103 _ 5) Interbay Management Panel - Page 103 _ 6) Frame Installation Kit - Page 103 _
10) Patch Cord - Pages 122–126* _ 11) In-Line Attenuator - Page 127 _
*See page 106 for standard cross-connect patch cord lengths
Trang 55/07 • 103742AE
Fiber Distributing Cabinets
The OMX600® fiber distributing cabinet provides mounting locations for termination, splice and storage
panels It is a completely front-facing frame; all mounting, maintenance and cable access is done on the front of the frame A lower trough allows multiple frames to be mounted in a continuous lineup The
frame is shipped with lockable front doors (locks ordered separately) Preconfigured frames are available
Catalog Number
MX6-TSF6030-7Z4
Dimensions (HxWxD)
2.14 m x 600 mm x 300 mm (7' x 23.6" x 11.8")
O r d e r i n g I n f o r m a t i o n
Description
OMX600 seismic zone 4 rated
fiber distributing cabinet
Please contact ADC Technical Assistance Center to order a preconfigured OMX600 frame
600 mm (23.6") 300 mm(11.8")
300 mm (11.8")
Front View
2.14 m (7')
Trang 65/07 • 103742AE
Preterminated Fiber Termination Panels with Pigtails
The OMX600® preterminated pigtail panels are available with either stranded or ribbon preterminated fiber bundles The panels are mounted on the frame and the fiber bundles are then routed directly to the splice section of the OMX600 frame This makes installation of the panels quick and easy, saving valuable installation time Preterminated pigtail panels may be ordered with a ”left“ orientation (mounts on the left side
of the frame) or a ”right“ orientation (mounts on the right side of the frame) ADC recommends the use of 2.0 mm patch cords to maximize the cable management potential of the OMX600
96-Position Panel
Catalog Number MX6-PM 0
Number of Pigtail Assemblies
06 For use with 72-position panel
08 For use with 96-position panel
12 For use with 144-position panel
Panel Capacity
A 72-position
B 96-position
C 144-position (LC only)
Connector/Adapter Type Singlemode
7 SC ultra polish
L SC angled polish
2 FC ultra polish
K LC ultra polish
M LC angled polish
Multimode (62.5/125 μm)
9 SC
A FC
P LC
Pigtail Type
1 12-fiber stranded
3 12-fiber ribbon
4 8-fiber stranded
5 8-fiber ribbon
8 6-fiber stranded
6 6-fiber ribbon
Block Orientation
L Left
R Right
Other configurations are available upon request Please contact ADC Technical Assistance Center
Trang 75/07 • 103742AE
Preterminated Fiber Termination Panels with Multifiber Cable – IFC
The OMX600® preterminated panel is available with
indoor rated intrafacility cable (IFC) in ribbon or stranded
configurations All panels are 100% factory tested to guarantee
continuity and reliable connections Preterminated panels make
installation quick and easy, reducing labor costs Panels may be
ordered with a ”left“ orientation (mounts on the left side of
the frame) or a ”right“ orientation (mounts on the right side of
the frame) ADC recommends the use of 2.0 mm patch cords
to maximize the cable management potential of the OMX600
96-Position Termination Panel Catalog Number
MX6-FM 0
Panel Capacity
A 72-position
B 96-position
C 144-position (LC only)
Connector and Adapter Type #1
Singlemode
7 SC ultra polish
L SC angled polish
2 FC ultra polish
K LC ultra polish (144 only)
M LC angled polish (144 only)
Multimode (62.5/125μm)
9 SC
P LC (144 only)
1 Panels using ADC‘s standard cable offering have a shorter lead time than panels using a specific cable
manufacturer ADC only provides GR-409 compliant cable that meets or exceeds our high quality standards.
Connector Type #2
Singlemode
0 No connector/stub end
7 SC ultra polish
L SC angled polish
2 FC ultra polish
K LC ultra polish
M LC angled polish
Multimode (62.5/125 μm)
0 No connector/stub end
9 SC
P LC
Cable Type (IFC Riser) Singlemode
ZB 72-fiber stranded
KA 72-fiber ribbon
ZC 96-fiber stranded
EF 96-fiber ribbon
ZD 144-fiber stranded
FK 144-fiber ribbon
Multimode (62.5/125 μm)
VM 72-fiber stranded
WM 96-fiber stranded
Block Orientation
L Left
R Right
Standard Single-Ended
016 16 m (50')
023 23 m (75')
031 31 m (100')
046 46 m (150')
061 61 m (200')
077 77 m (250')
092 92 m (300')
122 122 m (400')
153 153 m (500')
Non-Standard
Use XXX for length in meters
Other configurations are available upon request Please contact ADC Technical Assistance Center
Trang 85/07 • 103742AE
Adapter-Only Fiber Termination Panels
The OMX600® fiber termination panel with adapters only is available with 72-, 96- or 144-positions Panels may be ordered with a ”left“
orientation (mounts on the left side of the frame)
or a ”right“ orientation (mounts on the right side of the frame) ADC recommends the use
of 2.0 mm patch cords to maximize the cable management potential of the OMX600
72-Position Adapter-Only Fiber Termination Panel
Catalog Number MX6-TM 00
Panel Capacity
A 72-position
B 96-position
C 144-position (LC only)
Connector and Adapter Type Singlemode
7 SC ultra polish
L SC angled polish
2 FC ultra polish
K LC ultra polish
M LC angled polish
Multimode (62.5/125 μm)
9 SC
P LC
Other configurations are available upon request Please contact ADC Technical Assistance Center.
Block Orientation
L Left
R Right
Trang 95/07 • 103742AE
Splice Panels
The OMX600® splice panel provides mounting
positions and protection for 24 splice trays The
splice panel is the height of two termination panels
(30") The module may be ordered with a ”left“
orientation (mounts on the left side of the frame)
or a ”right“ orientation (mounts on the right side
of the frame) Splice panels must be mounted to
the frame starting in the bottom position
Catalog Number
MX6-24SPNL-R MX6-24SPNL-L
O r d e r i n g I n f o r m a t i o n
Description
OMX600 splice panel accommodates 24 splice trays
Right orientation
Left orientation
Splice Panel
Trang 105/07 • 103742AE
Value-Added Module (VAM) Chassis
Value-Added Module (VAM) System
ADC offers an expansive line of monitor, splitter, WDM and CWDM VAM plug-in modules designed
to meet all application needs Please reference the Value-Added Module (VAM) System Catalog
#101663AE for details at www.adc.com or contact ADC Customer Service.
The OMX600® high-density VAM chassis is designed to fit into any open chassis location within new or existing OMX600 fiber distribution frames Each chassis can accommodate a maximum of 18 high-density VAM plug-in modules, 18 bulkhead plates, 18 blank plates or any combination thereof
O r d e r i n g I n f o r m a t i o n
OMX600 high-density VAM chassis, unloaded
- left orientation; accommodates up to 18 single
OMX600 high-density modules
373 mm x 227 mm x 286 mm (14.7" x 8.9" x 11.3")
MX6-HDVAMCHAS-L
OMX600 high-density VAM chassis, unloaded
- right orientation; accommodates up to 18 single
OMX600 high-density modules
373 mm x 227 mm x 286 mm (14.7" x 8.9" x 11.3")
MX6-HDVAMCHAS-R
MX6-HDVAMCHAS-L
(Left Orientation)
MX6-HDVAMCHAS-R
(Right Orientation)
VAM Chassis
(Right Orientation)
Trang 115/07 • 103742AE
Interbay Management Panel
The OMX600 interbay management panel provides slack storage between
frames for interconnect or cross-connect jumpers The interbay management
panel is necessary when no jumper storage is provided on the OMX frame itself.
Frame Accessories
Jumper Storage Panel
The OMX600® jumper storage panel provides for jumper storage functionality within
the frame Up to five jumper storage panels can be mounted on one side of an OMX600
frame Jumper storage panels must be mounted to the frame starting in the bottom position
Catalog Number
MX6-ENDGRD
Dimensions (HxD)
2.14 m x 300 mm (84" x 11.8")
O r d e r i n g I n f o r m a t i o n
Description
End guard
End Guard
The OMX600 end guard provides protection for the fibers entering and exiting frames at the ends
of a lineup The end guard attaches directly to the frame, but does not add to the overall frame width
End guards are not required when ordering splice frames
Catalog Number
MX6-JSM00000
O r d e r i n g I n f o r m a t i o n
Description
Jumper storage panel
Dimensions (HxWxL)
368 mm x 127 mm x 248 mm (14.5" x 5" x 9.75")
Frame Installation Kit
Frame installation kits may be used on network frames and are seismic zone 4 rated
Catalog Number
RAC-MX0616
RAC-MX0615
O r d e r i n g I n f o r m a t i o n
Description
Concrete floor frame installation kit, includes:
(2) M8 bolts, 90 mm (3.5")
(4) M8 nuts
(8) flat washers
(4) lock washers
shims and anchor plates
Raised floor frame installation kit, includes:
(4) threaded rods M12 x 1 m (3.28")
(12) heavy nuts, lock and flat washers
(4) nuts with springs, M12
(2) 1.8 m (5.9") unistrut
(1) anchor kit
Catalog Number
MX6-IMP150
Dimensions (HxWxL)
2.14 m x 150 mm x 300 mm (84" x 15.9" x 11.8")
O r d e r i n g I n f o r m a t i o n
Description
Interbay management panel
Trang 125/07 • 103742AE
Frame Accessories Splice Frame
The OMX600® splice frame is a high-density splice solution, housing up to 1,440 splices within a 23.6- by 11.8-inch footprint Shipped complete with the necessary cable management, it features slots which secure and protect the round splice trays and can hold up to sixty 12-fiber splice trays on each vertical The frame is shipped with lockable front doors and may be ordered for applications in which the cables enter from above or below
2.14 m (7')
610 mm
Catalog Number
MX6-SPL6030-A-D7Z4 MX6-SPL6030-A-U7Z4 FEC-ACCCLMP01 MX6-SPLIFCCLMP
Dimensions (HxWxD)
2.14 m x 610 mm x 305 mm (7' x 24" x 12")
O r d e r i n g I n f o r m a t i o n
Description Fully configured splice frame
accommodates up to 1440 splices
Cable enters from underfloor Cable enters from top
Splice frame cable clamps for
OSP cable IFC cable
Trang 135/07 • 103742AE
Panel Accessories
Splice Tray
The round splice tray used in the OMX600®
simplifies installation and maintenance The
tray stores up to 9.8-feet of slack allowing the
installer to roll the tray away from the frame to
perform splicing
Catalog Number FST-DRS _ _ - _ _
00 FT HS MT
Empty Bare fusion Heat shrink (single fiber fusion) Mechanical (mass fusion)
Splice Type Drawer Capacity
1
For 8-fiber ribbon only
12
16
24
321
Other configurations are available upon request Please contact ADC Technical Assistance Center
Cable Clamp
The OMX600 cable clamp is used to secure the OSP/IFC cable to the base or top of the frame in
a non-splice frame
Catalog Number
OSP-CLPFEC-LG MX6-ACC001
O r d e r i n g I n f o r m a t i o n
Description
OSP/IFC cable clamp for
Top entry cables
Underfloor cable entry