Note: Panels ship with dummy fuses installed in all positions, one fused equipment designation card holder and card, a voltage designation label, two 2-hole lugs per power bus, two ring

Trang 1

Power Distribution Products

Trang 2

Table of Contents

Introduction 1

PowerWorx ® GMT 60e Series Ordering Information 2

Specifications 3

PowerWorx DSX PDP Ordering Information 4

Specifications 4

PowerWorx Traditional GMT Series Ordering Information 5

Specifications 6

Drawings and Sample Configurations 7

PowerWorx Uninterrupted Power GMT Series Ordering Information 8

Drawings and Sample Configuration 8

Specifications 9

PowerWorx SuperFilter ™ GMT Series Ordering Information 10

Specifications 11-12 PowerWorx SuperPower ™ GMT Series Fuse Panels Ordering Information 13

Specifications 14

Drawings and Sample Configurations 15

PowerWorx ® Select Series ™ Fuse Platform Ordering Information 16

Specifications 17

Drawings and Sample Configuration 18

PowerWorx Select Series ™ Fuse Platform with Low Voltage Disconnect Ordering Information 19

Specifications 20

PowerWorx Select Series ™ Circuit Breaker Platform Ordering Information 21

Specifications 22

Drawings and Sample Configurations 23

PowerWorx Accessories Cable Management Bars 24

Compression Lugs 24

Designation Card Holder and Cards 24

GMT Designation Pin Holder 24

GMT Fuses/Fuse Designation Pins – Alarm Indicator 25

GMT Fuse Puller 25

KLM Fuses – Non-Indicator 25

Rear Covers 26

Ring Lug Kit 26

TPA Fuses – Alarm Indicator 26

Trang 3

Table of Contents

PowerWorx ® Advantage Series ™ Platform

Ordering Information 27

Specifications 28

Drawings and Sample Configurations 29

Accessories for Advantage Series ™ Carling Breakers 30

Circuit Breaker Fingerguards 30

Compression Lugs 30

Input Power Terminal Block Cover 30

Output Power Terminal Block Cover 30

TPC Fuses/Fuse Holder 30

TPC Fuse Holder Adapter 30

Index 31-32

Trang 4

As networks and the variety of powered network

devices grow, so does the need for reliable power

distribution and protection in multimedia

broadband networks ADC’s PowerWorx power

distribution products have been engineered from

the ground up to properly protect and distribute

power to valuable, revenue-generating network

equipment

PowerWorx panels are independently tested to

comply with the industry’s highest standards,

including CE, IEC, UL, NEBS Level 3, Telecordia

(BellCore), CSA, and NEC 2002

Flexible PowerWorx configurations suit almost

every network application and the platform sets a

new standard – delivering the power and the

protection that service providers need

• Compliant with all major standards, including

UL, NEBS Level 3, Telcordia (BellCore), NEC

2002, CSA, IEC, and CE

• Backed by ADC quality, manufacturing excellence and exceptional customer service

• Flexible platform for use in central offices, headends, hubs, remote sites, etc.

PowerWorx Platform Decision Matrix

High Amperage Fuse Panel

Low Voltage Disconnect Panel

(GMT, TPA and GMT/TPA Combo Fuses)

Uninterrupted Capabilities Required?

Yes

Uninterrupted Power GMT Panel

Trang 5

As networks and the variety of powered

net-work devices grow, so does the need for reliable

power distribution and protection in multimedia

broadband networks ADC's PowerWorx has

been engineered from the ground up to properly

protect and distribute power to valuable,

rev-enue-generating network equipment

PowerWorx GMT 60e Series panels set a new

standard – delivering the power and the

protec-tion that service providers need So if your

net-work needs power that net-works, use PowerWorx

PowerWorx GMT 60e Series fuse panels deliver

power to valuable, revenue-generating network

equipment located in broadband multiservice

networks The GMT 60e Series accepts input

power up to 60 Amps per bus Up to 15 Ampsper fuse position is standard

PowerWorx panels are independently tested tocomply with the industry's highest standards,including CE, UL, CSA, and NEC 2002 In addi-tion, the GMT 60e Series is backed by a five-yearwarranty

Flexible PowerWorx configurations suit mostevery network application Panels can be mount-

ed into 19-inch (48.3 cm), 23-inch (58.4 cm),Electronic Industries Association (EIA) or WesternElectric Company (WECO), and 600 mm racks

User-friendly ”upside down“ fuse holders andhigh-brilliance LEDs allow technicians to quicklyidentify input power failure and blown fusealarms

GMT60e Series Fuse Panel - Standard front and rear access, EWX-001RGSBD10XEP Standard

GMT fuse type Features set-screw barrel connector input

and set-screw barrel terminal strip output Dual power feed,

10/10 position fuse configuration Does not include an

output alarm Putty white

GMT60e Series Fuse Panel - Standard front and rear access, GMT EWX-001RGSBD10BEP Standard

fuse type Features set-screw barrel connector input and

set-screw barrel terminal strip output Dual power feed, 10/10

position fuse configuration Includes set-screw barrel type alarm

contact connection Putty white

GMT60e Series Fuse Panel - Standard front and rear access, GMT EWX-001RGCBD10BEP Standard

fuse type Features stud-type powering input and set-screw

barrel terminal strip output Dual power feed, 10/10 position

fuse configuration Includes set-screw barrel type alarm

contact connection Putty white

O r d e r i n g I n f o r m a t i o n

Trang 6

Rack Mounting Width:

Rack Unit Spacing:

Fail Alarm Indicators:

Alarm Contact Connection:

Alarm Contact Relay:

Input Feed Connection:

Output Feed Connection:

or fuses.

Approximately 4 lbs (1.8 kg) 19" (48.3 cm) WECO (2")/EIA (1.75") rack unit spacing Flush mounting 23" (58.4 cm) and 600 mm rack extenders also available WECO (2")/EIA (1.75")

Cold-rolled 16 gauge steel Putty white powder-coat

0.2 to 15 Amps

60 Amps (maximum) per bus -48 Vdc (-42 to -56 Vdc tolerance) 12W maximum per bus

Red LED indicates blown fuse Green LED indicates power on Alarm output contacts provided for audible, visual and remote alarms (Optional) Set-screw barrel terminal strip accepts range of wire up to 12 AWG (3.3 mm)

1 Amp maximum Set-screw barrel connector accepts range of wire up to 6 AWG (13.3 mm) Stud-type (accepting two-hole compression lug) accepts range of wire up to

2 AWG (33.6 mm) Distance between barrier walls (stud-type) 62" (15.8 mm) Stud size 25" (6.35 mm) center to center spacing of studs 625" (15.88 mm) Set-screw barrel terminal strip accepts range of wire up to 12 AWG (3.3 mm) Single-post grounding accepts range of wire up to 10 AWG (5.2 mm)

-45°C to 85°C -5°C to 55°C 0% to 95%, non-condensing

Up to 13,000 feet (3.96 km) Five years

Panels ship with one fused-equipment designation card holder and card and one ring lug (for grounding)

* Important Note: The fuse manufacturer recommends that GMT fuses rated 8 to 15 Amps be continuously operated

at no more than 70% of their nominal current rating.

Trang 7

Primarily used to power LEDs in DSX modules, the PDP Series is also used to power auxiliary equipment

such as intraoffice and bridging repeaters as well as communication panels Features two-hole

compression lug-style power input terminals, field-replaceable, high brilliance red LEDs to ensure panel

uptime and enhanced fuse visibility with "upside down" installed GMT fuse holders Panel is compliant

with NEBS Level 3, UL, NEC 1999 and CSA

-42 to -56 Vdc (no strapping required)

60 Amps maximum per bus 125V maximum

Electrical Specifications

20-Position Fuse Panel

3 amp maximum GMT fuse, two-hole

compression lug input and screw-down barrier

terminal strip output Features single power feed,

single 20 position fuse configuration, fuse alarm

LED, wire wrap alarm contact connection and

EIA/WECO mounting option Putty White.

3 amp maximum GMT fuse, two-hole

compression lug input and screw-down barrier

terminal strip output Features single power feed,

single 20 position fuse configuration, fuse alarm

LED, wire wrap alarm contact connection and

EIA/WECO mounting option Black

Trang 8

With input power up to 65 Amps per bus, the

Traditional GMT Series eliminates the need to stock

varying amperage fuse panels Fuse management is

simplified by accommodating up to 15 Amps of

out-put power per fuse position – without the need to

space fuses A self-configuring voltage and polarity

feature allows a single panel to support most

applica-tions, providing ±24Vdc or ±48Vdc power

Note: Panels ship with dummy fuses installed in all positions, one fused equipment designation card

holder and card, a voltage designation label, two 2-hole lugs per power bus, two ring lugs (for

PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PWDP

front and rear access with GMT fuse, two-hole compression

lug input and screw-down barrier terminal strip output

Features dual power feed, 10/10 position fuse configuration,

power on and fuse alarm LED, wire wrap alarm contact

connection and EIA/WECO mounting option Putty white

PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PSDB Standard

front and rear access with GMT fuse, two-hole compression

lug input and screw-down barrier terminal strip output

Features dual power feed, 10/10 position fuse configuration,

power on and fuse alarm LED, screw-down barrier terminal

strip alarm contact connection and EIA/WECO mounting

option Black

PowerWorx Traditional GMT Series Fuse Panel - Total front PWX-002FGCSD10PWDP Standard

access with GMT fuse, two-hole compression lug input and

screw-down barrier terminal strip output Features dual

power feed, 10/10 position fuse configuration, power on

and fuse alarm LED, wire wrap alarm contact connection

and EIA/WECO mounting option Putty white

PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PSDP Standard

front and rear access with GMT fuse, two-hole compression

lug input and screw-down barrier terminal strip output

Features dual power feed, 10/10 position fuse configuration,

power on and fuse alarm LED, screw-down barrier terminal

strip alarm contact connection and EIA/WECO mounting

option Putty

PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PWDB Standard

front and rear access with GMT fuse, two-hole compression

lug input and screw-down barrier terminal strip output

Features dual power feed, 10/10 position fuse configuration,

power on and fuse alarm LED, wire wrap alarm contact

connection and EIA/WECO mounting option Black

PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD20PWDP Standard

front and rear access with GMT fuse, two-hole compression

lug input and screw-down barrier terminal strip output

Features dual power feed, 20/20 position fuse configuration,

power on and fuse alarm LED, wire wrap alarm contact

connection and EIA/WECO mounting option Putty white

O r d e r i n g I n f o r m a t i o n

Quick Ship

Trang 9

Operating Voltage:

Power Dissipation:

Fail Alarm Indicators:

Alarm Contact Connection:

Alarm Contact Relay:

Input Feed Connection:

Output Feed Connection:

or fuses.

Approximately 10 lbs (4.5 kg) 19" or 23" (48.3 or 58.4 cm) flush- or recess-mountable with universal mounting brackets EIA/WECO or ETSI mounting options available Cold-rolled 16 gauge steel Polycarbonate protective cover provided with all panels.

Putty white or black powder-coat

0.2 to 15 Amps (see chart below for details)

65 Amps (maximum) per bus

±24 Vdc (±21 to ±30 Vdc tolerance) or ±48 Vdc (±42 to ±56 Vdc tolerance)

40 watts maximum Red LED indicates blown fuse Green LED indicates power on Alarm output contacts provided for audible, visual and remote alarms.

Wire-wrap or screw-down barrier terminal strip

1 Amp maximum Two-hole compression-lug (stud-type) accepts range of wire up to

2 AWG Set screw barrel connector accepts range of wire up

to 6 AWG Panel ships with two 2-hole lugs (accepting 6 AWG wire) per power bus.

Screw-down barrier terminal strip or set screw barrel terminal strip accepts range of wire up to 12 AWG.

Two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to

#2 AWG.

-45°C to 85°C -5°C to 55°C 0% to 95%, non-condensing

Up to 13,000 feet (3.96 km) Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3, IEC, and

Screw-Down Set Screw Screw-Down Set Screw Screw-Down Set Screw Screw-Down Set Screw

Max Amperage Per Fuse Position

Post/

Stud Size

#6-32 NA

#6-32 NA

#3-48 NA

#3-48 NA

Distance Between Barriers Walls

0.325" (8.255 mm) NA

0.325" (8.255 mm) NA

0.20" (5.08 mm) NA 0.20" (5.08 mm) NA

1Important Note: The fuse manufacturer recommends that fuses be continuously operated at no more

than 70% of their nominal current rating

Trang 10

Drawings and Sample Configurations

Front

Rear

FUSE ALARM-A POWER-A FUSE ALARM-B POWER-B

FUSE INSTALLED UPSIDE-DOWN FUSE INSTALLED UPSIDE-DOWN

15 AMP MAX PER FUSE

1 2 3 4 5 6 7 8 9 1 0 1 2 3 4 5 6 7 8 9 1 0

BATT B RTN MAX INPUT 65A

INPUT VOLTAGE POS OR NEG / 24 OR 48 VDC

BATT A RTN MAX INPUT 65A

INPUT VOLTAGE POS OR NEG / 24 OR 48 VDC

C.GND C.GND ALARM

NO C NC

Standard 10/10-Position Dual Rear Power Feed

Sample Catalog Number: PWX-001RGCSD10PWDP

Front

Rear

Standard Single 10 Rear Power Feed

Sample Catalog Number: PWX-001RGCSS10PWDP

Front

Rear

Standard 10/10-Position Dual Rear Power Feed

Sample Catalog Number: PWX-001RGCSD20PWDP

Front

Total-Front-Access 10/10-Position Dual Power Feed

Sample Catalog Number: PWX-001FGCSD10PWDP

Trang 11

To ensure constant powering of fused network

equipment, the Uninterrupted Power GMT Series

features two input power feeds If power to one

fails, the other serves as backup – taking on the

load of the failed circuit while maintaining its own

load Schottky-steering diodes ensure panel uptimeuntil input power is restored, while a patent-pend-ing heat dissipation design ensures safety Thepanel offers input power up to 60 Amps per bus

Note: Panels ship with dummy fuses installed in all positions, one designation card holder and

card, one voltage designation label, two 2-hole lugs per power bus, two ring lugs (for

ground-ing), and one designation pin holder per fuse holder

Each side (BUS) must be able to handle load if A or B is lost (i.e 30 amps or 60 total per side)

PowerWorx Uninterrupted Power GMT Series Fuse Panel - PWX-011RGCSD10PWDP

Standard front and rear access with GMT fuse, two-hole

compression lug input and screw-down barrier terminal

strip output Features 10/10-position dual power feed,

power on and fuse alarm LED, Wire Wrap alarm contact

connection and EIA/WECO mounting option Putty white

PowerWorx Uninterrupted Power GMT Series Fuse Panel - PWX-011RGCSD10PWDB Standard

Standard front and rear access with GMT fuse, two-hole

compression lug input and screw-down barrier terminal

strip output Features 10/10-position dual power feed,

power on and fuse alarm LED, Wire Wrap alarm contact

connection and EIA/WECO mounting option Black

O r d e r i n g I n f o r m a t i o n

Front

Rear

Dual Power Feed 10/10-Position

Sample Catalog Number: PWX-011RGCSD10PWDP

Quick Ship

Trang 12

or fuses.

Approximately 11 lbs (4.5 kg) Using the universal mounting brackets, the standard fuse panel can be flush- or recess-mounted into 19-inch (48.3 cm) and 23-inch (58.4 cm) EIA and WECO racks Using the mounting brackets, the total front access fuse panel can be flush- or recess-mounted into 23-inch (58.4 cm) EIA and WECO racks.

Cold-rolled 16 gauge steel Polycarbonate protective coverprovided with all panels.

Putty white or black powder-coat

0.2 to 15 Amps

60 Amps (maximum) per bus -24 Vdc (-21 to -30 Vdc tolerance) or -48 Vdc (-42 to -56 Vdc tolerance)

40 watts maximum Red LED indicates blown fuse Green LED indicates power on.

Wire-Wrap alarm output contacts provided for audio, visual and remote alarms.

1 Amp maximum Two-hole compression-lug (stud-type) accepts range of wire up to 2 AWG Set screw barrel connector accepts range of wire up to 6 AWG Panel ships with two 2-hole lugs (accepting 6 AWG wire) per power bus Screw-down barrier terminal strip accepts range of wire up to 12 AWG Two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to

#2 AWG.

-45°C to 85°C -5°C to 55°C 0% to 95%, non-condensing

Up to 13,000 feet (3.96 km) Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3, IEC, and CE standardsLifetime

Operating Voltage:

Power Dissipation:

Fail Alarm Indicators:

Alarm Contact Connection:

Alarm Contact Relay:

Input Feed Connection:

Output Feed Connection:

1Important Note: The fuse manufacturer recommends that fuses be continuously operated at no more

than 70% of their nominal current rating

Fuse

Configuration

D10

Output Connector Type

Screw-down

Max Amperage Per Fuse Position

0.325" (8.255 mm)

Trang 13

PowerWorx SuperFilter™GMT Series panels deliver clean DC voltage to noise-sensitive network elements.

Using lowpass filters, all frequencies above 59 Hz are eliminated and unwanted power line noise is

suppressed The suppression level at 60 Hz is at least 35 dB with a greater level of suppression at higher

frequencies Additionally the integrated filter prevents the upstream flow of noise from fused equipment

to the batteries The unique design of the internal filter is patented

User-friendly “upside down” fuse holders and high-brilliance LEDs allow technicians to quickly identify

and replace blown fuses in the field Other features include two-post grounding, removable smoked

polycarbonate input/output connector covers, and two color options (putty white or black)

NOTE: Panels ship with dummy fuses installed in all positions, one designation card holder and card, two

2-hole lugs per power bus, two ring lugs (for grounding) and one designation pin holder per fuse holder

PowerWorx SuperFilter GMT Series Fuse Panel - Standard PWX-021RGCSD10PSDP

front and rear access with GMT fuse, two-hole compression

lug input and screw-down barrier terminal strip output

Features 10/10-position dual power feed, power on and

fuse alarm LED, screw-down barrier terminal strip alarm

contact connection and EIA/WECO mounting option Putty

PowerWorx SuperFilter GMT Series Fuse Panel - Standard PWX-021RGCSD10PSDB Standard

front and rear access with GMT fuse, two-hole compression

lug input and screw-down barrier terminal strip output

Features 10/10-position dual power feed, power on and

fuse alarm LED, screw-down barrier terminal strip alarm

contact connection and EIA/WECO mounting option Black

O r d e r i n g I n f o r m a t i o n

Quick Ship

Trang 14

Fail Alarm Indicators:

Alarm Contact Connection:

Alarm Contact Relay:

Input Power Input Feed Connection:

Output Power Output Feed Connection:

Grounding:

1.75" x 17.12" x 10" (4.44 x 43.48 x 25.4 cm) Dimensions do not include depth of power connectors, alarm lamps or fuses Approximately 11 lbs (4.99 kg)

19" or 23" (48.3 or 58.4 cm) recess-mountable with mounting ears EIA/WECO mountable

Cold-rolled 16 gauge steel Polycarbonate protective coverprovided with all panels

Powder-coat putty white or black

0.2 to 20 Amps

50 Amps (maximum) per bus -48 Vdc (-42 to -56 Vdc tolerance)

40 watts maximum Red LED indicates blown fuse Green LED indicates power on Two sets of alarm output contacts provided for audible, visual or remote alarms Screw-down barrier terminal strip

1 Amp maximum Two-hole compression lug (stud-type) accepts range of wire up to 2 AWG Panel ships with two 2-hole lugs (accepting 6 AWG wire)

per power bus Screw-down barrier terminal strip accepts range of wire up

to 12 AWG Two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to

#2 AWG.

Specifiations

10/10-Position Dual Power Feed

Sample Catalog Number: PWX-021RGCSD10PSDP

Trang 15

Without Power With Power

Up to 13,000 feet (3.96 km) Meets UL, Telcordia (Bellcore), NEC 2002, and CSA NEBS L3 certified

Screw-Down

Max Amperage Per Fuse Position

0.325" (8.255 mm) Note: -30 dB of supression relates to a noise

power of 1 micro-watt

Trang 16

PowerWorx SuperPower GMT Series panels

accept high input power – up to 100 Amps per

bus – with up to 20 Amps output power per

GMT fuse position Standard (front and rear

access) and total-front-access panels are available

User-friendly “upside down” fuse holders andhigh-brilliance LEDs allow technicians to quicklyidentify and replace blown fuses in the field

Other features include two-post grounding,removable clear polycarbonate input/output con-nector covers, and a selection of connector andfuse configurations

Note: Panels ship with dummy fuses installed in all positions, one fused equipment designation

card holder and cards, one voltage designation label, two 2-hole lugs per power bus (accepts 2

AWG stranded wire), two ring lugs (for grounding), and four sheets of perforated fuse

designa-tion cards and six plastic covers

PowerWorx SuperPower GMT Series Fuse Panel - Standard PWX-031RGCSD10PWDP

front and rear access with GMT fuse, two-hole compression lug

input and screw-down barrier terminal strip output Features

10/10-position dual power feed, power on and fuse alarm LED,

Wire wrap alarm contact connection and EIA/WECO mounting

option Putty white

PowerWorx SuperPower GMT Series Fuse Panel - Standard PWX-031RGCSD20PWDP Standard

front and rear access with GMT fuse, two-hole compression lug

input and screw-down barrier terminal strip output Features

20/20-position dual power feed, power on and fuse alarm LED,

Wire wrap alarm contact connection and EIA/WECO mounting

option Putty white

PowerWorx SuperPower GMT Series Fuse Panel - Total front PWX-031FGCSD10PWDP Standard

access (no rear) with GMT fuse, two-hole compression lug input

and screw-down barrier terminal strip output Features

10/10-position dual power feed, power on and fuse alarm LED,

Wire wrap alarm contact connection and EIA/WECO mounting

option Putty white

PowerWorx SuperPower GMT Series Fuse Panel - Total front PWX-031FGCSD20PWDP Standard

access (no rear) with GMT fuse, two-hole compression lug input

and screw-down barrier terminal strip output Features

20/20-position dual power feed, power on and fuse alarm

LED, Wire wrap alarm contact connection and EIA/WECO

mounting option Putty white

O r d e r i n g I n f o r m a t i o n

Quick Ship

Trang 17

Operating Voltage:

Power Dissipation:

Fail Alarm Indicators:

Alarm Contact Connection:

Alarm Contact Relay:

Input Feed Connection:

Output Feed Connection:

do not include depth of power connectors, alarm lamps or fuses.

Approximately 10 lbs (4.5 kg) Using the universal mounting brackets, the standard fuse panel can be flush-

or recess-mounted into 19-inch (48.3 cm) and 23-inch (58.4 cm) EIA and WECO rack Using the mounting brackets, the total front access fuse panel can be flush- or recess-mounted into 23-inch (58.4 cm) EIA and WECO racks Cold-rolled 16 gauge steel Polycarbonate protective cover provided with all panels.

Putty white powder-coat

0.2 to 20 Amps

100 Amps maximum per bus (200 Amps total) -24 Vdc (-21 to -30 Vdc tolerance) or -48 Vdc (-42 to -56 Vdc tolerance)

100 watts maximum Red LED indicates blown fuse Green LED indicates power on

Wire-wrap connections Alarm output contacts provided for audible, visual and remote alarms.

1 Amp maximum Two-hole compression-lug (stud-type) accepts range of wire up to 2 AWG Panel ships with two 2-hole lugs (accepting 2 AWG stranded wire) per power bus.

Screw-down barrier terminal strip accepts range of wire up to 12 AWG Two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to

#2 AWG.

-45°C to 85°C -5°C to 55°C 0% to 95%, non-condensing

Up to 13,000 feet (3.96 km) Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3, IEC, and

CE standards

15 years

1Important Note: The fuse manufacturer recommends that fuses be continuously operated at no more

than 70% of their nominal current rating

Screw-Down Screw-Down

Max Amperage Per Fuse Position

0.325" (8.255 mm) 0.20" (5.08 mm)

Trang 18

Drawings and Sample Configurations

BATT A

BATT B RTN A

RTN B

CAUTION HOT SURFACE

FUSE ALARM

FUSE ALARM

15 AMP MAX PER FUSE

POWER A

POWER B

BATT RTN

RTN BATT A

B

100A MAX INPUT

Dual Power Feed 20/20-Position

Sample Catalog Number: PWX-031RGCBD20PWDP

Total-Front-Access Dual Power Feed 10/10-Position

Sample Catalog Number: PWX-031FGCSD10PWDP

Front

Front

Rear

Dual Power Feed 10/10-Position

Sample Catalog Number: PWX-031RGCSD10PWDP

Front

Rear