Note: Panels ship with dummy fuses installed in all positions, one fused equipment designation card holder and card, a voltage designation label, two 2-hole lugs per power bus, two ring
Trang 1Power Distribution Products
Trang 2Table of Contents
Introduction 1
PowerWorx ® GMT 60e Series Ordering Information 2
Specifications 3
PowerWorx DSX PDP Ordering Information 4
Specifications 4
PowerWorx Traditional GMT Series Ordering Information 5
Specifications 6
Drawings and Sample Configurations 7
PowerWorx Uninterrupted Power GMT Series Ordering Information 8
Drawings and Sample Configuration 8
Specifications 9
PowerWorx SuperFilter ™ GMT Series Ordering Information 10
Specifications 11-12 PowerWorx SuperPower ™ GMT Series Fuse Panels Ordering Information 13
Specifications 14
Drawings and Sample Configurations 15
PowerWorx ® Select Series ™ Fuse Platform Ordering Information 16
Specifications 17
Drawings and Sample Configuration 18
PowerWorx Select Series ™ Fuse Platform with Low Voltage Disconnect Ordering Information 19
Specifications 20
PowerWorx Select Series ™ Circuit Breaker Platform Ordering Information 21
Specifications 22
Drawings and Sample Configurations 23
PowerWorx Accessories Cable Management Bars 24
Compression Lugs 24
Designation Card Holder and Cards 24
GMT Designation Pin Holder 24
GMT Fuses/Fuse Designation Pins – Alarm Indicator 25
GMT Fuse Puller 25
KLM Fuses – Non-Indicator 25
Rear Covers 26
Ring Lug Kit 26
TPA Fuses – Alarm Indicator 26
Trang 3Table of Contents
PowerWorx ® Advantage Series ™ Platform
Ordering Information 27
Specifications 28
Drawings and Sample Configurations 29
Accessories for Advantage Series ™ Carling Breakers 30
Circuit Breaker Fingerguards 30
Compression Lugs 30
Input Power Terminal Block Cover 30
Output Power Terminal Block Cover 30
TPC Fuses/Fuse Holder 30
TPC Fuse Holder Adapter 30
Index 31-32
Trang 4As networks and the variety of powered network
devices grow, so does the need for reliable power
distribution and protection in multimedia
broadband networks ADC’s PowerWorx power
distribution products have been engineered from
the ground up to properly protect and distribute
power to valuable, revenue-generating network
equipment
PowerWorx panels are independently tested to
comply with the industry’s highest standards,
including CE, IEC, UL, NEBS Level 3, Telecordia
(BellCore), CSA, and NEC 2002
Flexible PowerWorx configurations suit almost
every network application and the platform sets a
new standard – delivering the power and the
protection that service providers need
• Compliant with all major standards, including
UL, NEBS Level 3, Telcordia (BellCore), NEC
2002, CSA, IEC, and CE
• Backed by ADC quality, manufacturing excellence and exceptional customer service
• Flexible platform for use in central offices, headends, hubs, remote sites, etc.
PowerWorx Platform Decision Matrix
High Amperage Fuse Panel
Low Voltage Disconnect Panel
(GMT, TPA and GMT/TPA Combo Fuses)
•
Uninterrupted Capabilities Required?
Yes
Uninterrupted Power GMT Panel
Trang 5As networks and the variety of powered
net-work devices grow, so does the need for reliable
power distribution and protection in multimedia
broadband networks ADC's PowerWorx has
been engineered from the ground up to properly
protect and distribute power to valuable,
rev-enue-generating network equipment
PowerWorx GMT 60e Series panels set a new
standard – delivering the power and the
protec-tion that service providers need So if your
net-work needs power that net-works, use PowerWorx
PowerWorx GMT 60e Series fuse panels deliver
power to valuable, revenue-generating network
equipment located in broadband multiservice
networks The GMT 60e Series accepts input
power up to 60 Amps per bus Up to 15 Ampsper fuse position is standard
PowerWorx panels are independently tested tocomply with the industry's highest standards,including CE, UL, CSA, and NEC 2002 In addi-tion, the GMT 60e Series is backed by a five-yearwarranty
Flexible PowerWorx configurations suit mostevery network application Panels can be mount-
ed into 19-inch (48.3 cm), 23-inch (58.4 cm),Electronic Industries Association (EIA) or WesternElectric Company (WECO), and 600 mm racks
User-friendly ”upside down“ fuse holders andhigh-brilliance LEDs allow technicians to quicklyidentify input power failure and blown fusealarms
GMT60e Series Fuse Panel - Standard front and rear access, EWX-001RGSBD10XEP Standard
GMT fuse type Features set-screw barrel connector input
and set-screw barrel terminal strip output Dual power feed,
10/10 position fuse configuration Does not include an
output alarm Putty white
GMT60e Series Fuse Panel - Standard front and rear access, GMT EWX-001RGSBD10BEP Standard
fuse type Features set-screw barrel connector input and
set-screw barrel terminal strip output Dual power feed, 10/10
position fuse configuration Includes set-screw barrel type alarm
contact connection Putty white
GMT60e Series Fuse Panel - Standard front and rear access, GMT EWX-001RGCBD10BEP Standard
fuse type Features stud-type powering input and set-screw
barrel terminal strip output Dual power feed, 10/10 position
fuse configuration Includes set-screw barrel type alarm
contact connection Putty white
O r d e r i n g I n f o r m a t i o n
Trang 6Rack Mounting Width:
Rack Unit Spacing:
Fail Alarm Indicators:
Alarm Contact Connection:
Alarm Contact Relay:
Input Feed Connection:
Output Feed Connection:
or fuses.
Approximately 4 lbs (1.8 kg) 19" (48.3 cm) WECO (2")/EIA (1.75") rack unit spacing Flush mounting 23" (58.4 cm) and 600 mm rack extenders also available WECO (2")/EIA (1.75")
Cold-rolled 16 gauge steel Putty white powder-coat
0.2 to 15 Amps
60 Amps (maximum) per bus -48 Vdc (-42 to -56 Vdc tolerance) 12W maximum per bus
Red LED indicates blown fuse Green LED indicates power on Alarm output contacts provided for audible, visual and remote alarms (Optional) Set-screw barrel terminal strip accepts range of wire up to 12 AWG (3.3 mm)
1 Amp maximum Set-screw barrel connector accepts range of wire up to 6 AWG (13.3 mm) Stud-type (accepting two-hole compression lug) accepts range of wire up to
2 AWG (33.6 mm) Distance between barrier walls (stud-type) 62" (15.8 mm) Stud size 25" (6.35 mm) center to center spacing of studs 625" (15.88 mm) Set-screw barrel terminal strip accepts range of wire up to 12 AWG (3.3 mm) Single-post grounding accepts range of wire up to 10 AWG (5.2 mm)
-45°C to 85°C -5°C to 55°C 0% to 95%, non-condensing
Up to 13,000 feet (3.96 km) Five years
Panels ship with one fused-equipment designation card holder and card and one ring lug (for grounding)
* Important Note: The fuse manufacturer recommends that GMT fuses rated 8 to 15 Amps be continuously operated
at no more than 70% of their nominal current rating.
Trang 7Primarily used to power LEDs in DSX modules, the PDP Series is also used to power auxiliary equipment
such as intraoffice and bridging repeaters as well as communication panels Features two-hole
compression lug-style power input terminals, field-replaceable, high brilliance red LEDs to ensure panel
uptime and enhanced fuse visibility with "upside down" installed GMT fuse holders Panel is compliant
with NEBS Level 3, UL, NEC 1999 and CSA
-42 to -56 Vdc (no strapping required)
60 Amps maximum per bus 125V maximum
Electrical Specifications
20-Position Fuse Panel
3 amp maximum GMT fuse, two-hole
compression lug input and screw-down barrier
terminal strip output Features single power feed,
single 20 position fuse configuration, fuse alarm
LED, wire wrap alarm contact connection and
EIA/WECO mounting option Putty White.
3 amp maximum GMT fuse, two-hole
compression lug input and screw-down barrier
terminal strip output Features single power feed,
single 20 position fuse configuration, fuse alarm
LED, wire wrap alarm contact connection and
EIA/WECO mounting option Black
Trang 8With input power up to 65 Amps per bus, the
Traditional GMT Series eliminates the need to stock
varying amperage fuse panels Fuse management is
simplified by accommodating up to 15 Amps of
out-put power per fuse position – without the need to
space fuses A self-configuring voltage and polarity
feature allows a single panel to support most
applica-tions, providing ±24Vdc or ±48Vdc power
Note: Panels ship with dummy fuses installed in all positions, one fused equipment designation card
holder and card, a voltage designation label, two 2-hole lugs per power bus, two ring lugs (for
PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PWDP
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output
Features dual power feed, 10/10 position fuse configuration,
power on and fuse alarm LED, wire wrap alarm contact
connection and EIA/WECO mounting option Putty white
PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PSDB Standard
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output
Features dual power feed, 10/10 position fuse configuration,
power on and fuse alarm LED, screw-down barrier terminal
strip alarm contact connection and EIA/WECO mounting
option Black
PowerWorx Traditional GMT Series Fuse Panel - Total front PWX-002FGCSD10PWDP Standard
access with GMT fuse, two-hole compression lug input and
screw-down barrier terminal strip output Features dual
power feed, 10/10 position fuse configuration, power on
and fuse alarm LED, wire wrap alarm contact connection
and EIA/WECO mounting option Putty white
PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PSDP Standard
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output
Features dual power feed, 10/10 position fuse configuration,
power on and fuse alarm LED, screw-down barrier terminal
strip alarm contact connection and EIA/WECO mounting
option Putty
PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PWDB Standard
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output
Features dual power feed, 10/10 position fuse configuration,
power on and fuse alarm LED, wire wrap alarm contact
connection and EIA/WECO mounting option Black
PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD20PWDP Standard
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output
Features dual power feed, 20/20 position fuse configuration,
power on and fuse alarm LED, wire wrap alarm contact
connection and EIA/WECO mounting option Putty white
O r d e r i n g I n f o r m a t i o n
Quick Ship
Trang 9Operating Voltage:
Power Dissipation:
Fail Alarm Indicators:
Alarm Contact Connection:
Alarm Contact Relay:
Input Feed Connection:
Output Feed Connection:
or fuses.
Approximately 10 lbs (4.5 kg) 19" or 23" (48.3 or 58.4 cm) flush- or recess-mountable with universal mounting brackets EIA/WECO or ETSI mounting options available Cold-rolled 16 gauge steel Polycarbonate protective cover provided with all panels.
Putty white or black powder-coat
0.2 to 15 Amps (see chart below for details)
65 Amps (maximum) per bus
±24 Vdc (±21 to ±30 Vdc tolerance) or ±48 Vdc (±42 to ±56 Vdc tolerance)
40 watts maximum Red LED indicates blown fuse Green LED indicates power on Alarm output contacts provided for audible, visual and remote alarms.
Wire-wrap or screw-down barrier terminal strip
1 Amp maximum Two-hole compression-lug (stud-type) accepts range of wire up to
2 AWG Set screw barrel connector accepts range of wire up
to 6 AWG Panel ships with two 2-hole lugs (accepting 6 AWG wire) per power bus.
Screw-down barrier terminal strip or set screw barrel terminal strip accepts range of wire up to 12 AWG.
Two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to
#2 AWG.
-45°C to 85°C -5°C to 55°C 0% to 95%, non-condensing
Up to 13,000 feet (3.96 km) Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3, IEC, and
Screw-Down Set Screw Screw-Down Set Screw Screw-Down Set Screw Screw-Down Set Screw
Max Amperage Per Fuse Position
Post/
Stud Size
#6-32 NA
#6-32 NA
#3-48 NA
#3-48 NA
Distance Between Barriers Walls
0.325" (8.255 mm) NA
0.325" (8.255 mm) NA
0.20" (5.08 mm) NA 0.20" (5.08 mm) NA
1Important Note: The fuse manufacturer recommends that fuses be continuously operated at no more
than 70% of their nominal current rating
Trang 10Drawings and Sample Configurations
Front
Rear
FUSE ALARM-A POWER-A FUSE ALARM-B POWER-B
FUSE INSTALLED UPSIDE-DOWN FUSE INSTALLED UPSIDE-DOWN
15 AMP MAX PER FUSE
1 2 3 4 5 6 7 8 9 1 0 1 2 3 4 5 6 7 8 9 1 0
BATT B RTN MAX INPUT 65A
INPUT VOLTAGE POS OR NEG / 24 OR 48 VDC
BATT A RTN MAX INPUT 65A
INPUT VOLTAGE POS OR NEG / 24 OR 48 VDC
C.GND C.GND ALARM
NO C NC
Standard 10/10-Position Dual Rear Power Feed
Sample Catalog Number: PWX-001RGCSD10PWDP
Front
Rear
Standard Single 10 Rear Power Feed
Sample Catalog Number: PWX-001RGCSS10PWDP
Front
Rear
Standard 10/10-Position Dual Rear Power Feed
Sample Catalog Number: PWX-001RGCSD20PWDP
Front
Total-Front-Access 10/10-Position Dual Power Feed
Sample Catalog Number: PWX-001FGCSD10PWDP
Trang 11To ensure constant powering of fused network
equipment, the Uninterrupted Power GMT Series
features two input power feeds If power to one
fails, the other serves as backup – taking on the
load of the failed circuit while maintaining its own
load Schottky-steering diodes ensure panel uptimeuntil input power is restored, while a patent-pend-ing heat dissipation design ensures safety Thepanel offers input power up to 60 Amps per bus
Note: Panels ship with dummy fuses installed in all positions, one designation card holder and
card, one voltage designation label, two 2-hole lugs per power bus, two ring lugs (for
ground-ing), and one designation pin holder per fuse holder
Each side (BUS) must be able to handle load if A or B is lost (i.e 30 amps or 60 total per side)
PowerWorx Uninterrupted Power GMT Series Fuse Panel - PWX-011RGCSD10PWDP
Standard front and rear access with GMT fuse, two-hole
compression lug input and screw-down barrier terminal
strip output Features 10/10-position dual power feed,
power on and fuse alarm LED, Wire Wrap alarm contact
connection and EIA/WECO mounting option Putty white
PowerWorx Uninterrupted Power GMT Series Fuse Panel - PWX-011RGCSD10PWDB Standard
Standard front and rear access with GMT fuse, two-hole
compression lug input and screw-down barrier terminal
strip output Features 10/10-position dual power feed,
power on and fuse alarm LED, Wire Wrap alarm contact
connection and EIA/WECO mounting option Black
O r d e r i n g I n f o r m a t i o n
Front
Rear
Dual Power Feed 10/10-Position
Sample Catalog Number: PWX-011RGCSD10PWDP
Quick Ship
Trang 12or fuses.
Approximately 11 lbs (4.5 kg) Using the universal mounting brackets, the standard fuse panel can be flush- or recess-mounted into 19-inch (48.3 cm) and 23-inch (58.4 cm) EIA and WECO racks Using the mounting brackets, the total front access fuse panel can be flush- or recess-mounted into 23-inch (58.4 cm) EIA and WECO racks.
Cold-rolled 16 gauge steel Polycarbonate protective coverprovided with all panels.
Putty white or black powder-coat
0.2 to 15 Amps
60 Amps (maximum) per bus -24 Vdc (-21 to -30 Vdc tolerance) or -48 Vdc (-42 to -56 Vdc tolerance)
40 watts maximum Red LED indicates blown fuse Green LED indicates power on.
Wire-Wrap alarm output contacts provided for audio, visual and remote alarms.
1 Amp maximum Two-hole compression-lug (stud-type) accepts range of wire up to 2 AWG Set screw barrel connector accepts range of wire up to 6 AWG Panel ships with two 2-hole lugs (accepting 6 AWG wire) per power bus Screw-down barrier terminal strip accepts range of wire up to 12 AWG Two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to
#2 AWG.
-45°C to 85°C -5°C to 55°C 0% to 95%, non-condensing
Up to 13,000 feet (3.96 km) Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3, IEC, and CE standardsLifetime
Operating Voltage:
Power Dissipation:
Fail Alarm Indicators:
Alarm Contact Connection:
Alarm Contact Relay:
Input Feed Connection:
Output Feed Connection:
1Important Note: The fuse manufacturer recommends that fuses be continuously operated at no more
than 70% of their nominal current rating
Fuse
Configuration
D10
Output Connector Type
Screw-down
Max Amperage Per Fuse Position
0.325" (8.255 mm)
Trang 13PowerWorx SuperFilter™GMT Series panels deliver clean DC voltage to noise-sensitive network elements.
Using lowpass filters, all frequencies above 59 Hz are eliminated and unwanted power line noise is
suppressed The suppression level at 60 Hz is at least 35 dB with a greater level of suppression at higher
frequencies Additionally the integrated filter prevents the upstream flow of noise from fused equipment
to the batteries The unique design of the internal filter is patented
User-friendly “upside down” fuse holders and high-brilliance LEDs allow technicians to quickly identify
and replace blown fuses in the field Other features include two-post grounding, removable smoked
polycarbonate input/output connector covers, and two color options (putty white or black)
NOTE: Panels ship with dummy fuses installed in all positions, one designation card holder and card, two
2-hole lugs per power bus, two ring lugs (for grounding) and one designation pin holder per fuse holder
PowerWorx SuperFilter GMT Series Fuse Panel - Standard PWX-021RGCSD10PSDP
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output
Features 10/10-position dual power feed, power on and
fuse alarm LED, screw-down barrier terminal strip alarm
contact connection and EIA/WECO mounting option Putty
PowerWorx SuperFilter GMT Series Fuse Panel - Standard PWX-021RGCSD10PSDB Standard
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output
Features 10/10-position dual power feed, power on and
fuse alarm LED, screw-down barrier terminal strip alarm
contact connection and EIA/WECO mounting option Black
O r d e r i n g I n f o r m a t i o n
Quick Ship
Trang 14Fail Alarm Indicators:
Alarm Contact Connection:
Alarm Contact Relay:
Input Power Input Feed Connection:
Output Power Output Feed Connection:
Grounding:
1.75" x 17.12" x 10" (4.44 x 43.48 x 25.4 cm) Dimensions do not include depth of power connectors, alarm lamps or fuses Approximately 11 lbs (4.99 kg)
19" or 23" (48.3 or 58.4 cm) recess-mountable with mounting ears EIA/WECO mountable
Cold-rolled 16 gauge steel Polycarbonate protective coverprovided with all panels
Powder-coat putty white or black
0.2 to 20 Amps
50 Amps (maximum) per bus -48 Vdc (-42 to -56 Vdc tolerance)
40 watts maximum Red LED indicates blown fuse Green LED indicates power on Two sets of alarm output contacts provided for audible, visual or remote alarms Screw-down barrier terminal strip
1 Amp maximum Two-hole compression lug (stud-type) accepts range of wire up to 2 AWG Panel ships with two 2-hole lugs (accepting 6 AWG wire)
per power bus Screw-down barrier terminal strip accepts range of wire up
to 12 AWG Two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to
#2 AWG.
Specifiations
10/10-Position Dual Power Feed
Sample Catalog Number: PWX-021RGCSD10PSDP
Trang 15Without Power With Power
Up to 13,000 feet (3.96 km) Meets UL, Telcordia (Bellcore), NEC 2002, and CSA NEBS L3 certified
Screw-Down
Max Amperage Per Fuse Position
0.325" (8.255 mm) Note: -30 dB of supression relates to a noise
power of 1 micro-watt
Trang 16PowerWorx SuperPower GMT Series panels
accept high input power – up to 100 Amps per
bus – with up to 20 Amps output power per
GMT fuse position Standard (front and rear
access) and total-front-access panels are available
User-friendly “upside down” fuse holders andhigh-brilliance LEDs allow technicians to quicklyidentify and replace blown fuses in the field
Other features include two-post grounding,removable clear polycarbonate input/output con-nector covers, and a selection of connector andfuse configurations
Note: Panels ship with dummy fuses installed in all positions, one fused equipment designation
card holder and cards, one voltage designation label, two 2-hole lugs per power bus (accepts 2
AWG stranded wire), two ring lugs (for grounding), and four sheets of perforated fuse
designa-tion cards and six plastic covers
PowerWorx SuperPower GMT Series Fuse Panel - Standard PWX-031RGCSD10PWDP
front and rear access with GMT fuse, two-hole compression lug
input and screw-down barrier terminal strip output Features
10/10-position dual power feed, power on and fuse alarm LED,
Wire wrap alarm contact connection and EIA/WECO mounting
option Putty white
PowerWorx SuperPower GMT Series Fuse Panel - Standard PWX-031RGCSD20PWDP Standard
front and rear access with GMT fuse, two-hole compression lug
input and screw-down barrier terminal strip output Features
20/20-position dual power feed, power on and fuse alarm LED,
Wire wrap alarm contact connection and EIA/WECO mounting
option Putty white
PowerWorx SuperPower GMT Series Fuse Panel - Total front PWX-031FGCSD10PWDP Standard
access (no rear) with GMT fuse, two-hole compression lug input
and screw-down barrier terminal strip output Features
10/10-position dual power feed, power on and fuse alarm LED,
Wire wrap alarm contact connection and EIA/WECO mounting
option Putty white
PowerWorx SuperPower GMT Series Fuse Panel - Total front PWX-031FGCSD20PWDP Standard
access (no rear) with GMT fuse, two-hole compression lug input
and screw-down barrier terminal strip output Features
20/20-position dual power feed, power on and fuse alarm
LED, Wire wrap alarm contact connection and EIA/WECO
mounting option Putty white
O r d e r i n g I n f o r m a t i o n
Quick Ship
Trang 17Operating Voltage:
Power Dissipation:
Fail Alarm Indicators:
Alarm Contact Connection:
Alarm Contact Relay:
Input Feed Connection:
Output Feed Connection:
do not include depth of power connectors, alarm lamps or fuses.
Approximately 10 lbs (4.5 kg) Using the universal mounting brackets, the standard fuse panel can be flush-
or recess-mounted into 19-inch (48.3 cm) and 23-inch (58.4 cm) EIA and WECO rack Using the mounting brackets, the total front access fuse panel can be flush- or recess-mounted into 23-inch (58.4 cm) EIA and WECO racks Cold-rolled 16 gauge steel Polycarbonate protective cover provided with all panels.
Putty white powder-coat
0.2 to 20 Amps
100 Amps maximum per bus (200 Amps total) -24 Vdc (-21 to -30 Vdc tolerance) or -48 Vdc (-42 to -56 Vdc tolerance)
100 watts maximum Red LED indicates blown fuse Green LED indicates power on
Wire-wrap connections Alarm output contacts provided for audible, visual and remote alarms.
1 Amp maximum Two-hole compression-lug (stud-type) accepts range of wire up to 2 AWG Panel ships with two 2-hole lugs (accepting 2 AWG stranded wire) per power bus.
Screw-down barrier terminal strip accepts range of wire up to 12 AWG Two-post grounding accepts range of wire up to #10 AWG for single connection; two-hole compression lug (stud-type) accepts wire up to
#2 AWG.
-45°C to 85°C -5°C to 55°C 0% to 95%, non-condensing
Up to 13,000 feet (3.96 km) Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3, IEC, and
CE standards
15 years
1Important Note: The fuse manufacturer recommends that fuses be continuously operated at no more
than 70% of their nominal current rating
Screw-Down Screw-Down
Max Amperage Per Fuse Position
0.325" (8.255 mm) 0.20" (5.08 mm)
Trang 18Drawings and Sample Configurations
BATT A
BATT B RTN A
RTN B
CAUTION HOT SURFACE
FUSE ALARM
FUSE ALARM
15 AMP MAX PER FUSE
POWER A
POWER B
BATT RTN
RTN BATT A
B
100A MAX INPUT
Dual Power Feed 20/20-Position
Sample Catalog Number: PWX-031RGCBD20PWDP
Total-Front-Access Dual Power Feed 10/10-Position
Sample Catalog Number: PWX-031FGCSD10PWDP
Front
Front
Rear
Dual Power Feed 10/10-Position
Sample Catalog Number: PWX-031RGCSD10PWDP
Front
Rear