1. Trang chủ
  2. » Công Nghệ Thông Tin

Datasheet - FO - Cable - OM3 6 core N006CTSLZH050U fiber

7 331 0
Tài liệu đã được kiểm tra trùng lặp

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Tiêu đề Central Tube Single Jacket/Non-Armor Cable 50/125um, 10Gigabit Ethernet MMF
Thể loại Technical specification
Định dạng
Số trang 7
Dung lượng 148,13 KB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

1.2 Cable Description 1 Low Smoke Zero HalogenLSZH Single Jacket 10 Gigabit Ethernet Multi mode color coded fibers, filled central tube, glass yarn as non-metallic armor, water swella

Trang 1

TECHNICAL SPECIFICATION

Central Tube Single Jacket/non-Armor Cable

50/125um, 10Gigabit Ethernet MMF

P/N N006CTSLZH050U

Trang 2

1 SCOPE

1.1 Application

This specification covers the general requirements for fiber optic telecommunication

cables used for indoor/outdoor application

1.2 Cable Description

1) Low Smoke Zero Halogen(LSZH) Single Jacket

10 Gigabit Ethernet Multi mode color coded fibers, filled central tube, glass yarn as

non-metallic armor, water swellable yarn and outer LSZH jacket

2 OPTICAL FIBER

The optical geometrical and mechanical performance of the optical fiber shall be in

accordance with Table 1 below

Table 1 The Characteristics of the 50um Multi Mode Fiber(10 Gb-E)

Attenuation dB/km ≤ 3.0 at 850nm

≤ 1.0 at 1300nm

10 Gigabit Ethernet

Operational Length m ≥ 300 at 850nm

Effective Modal Bandwidth MHz.km ≥ 2000 at 850nm

Numerical Aperture - 0.20 ± 0.015

Core Non-circularity % ≤ 6.0

Cladding Non-circularity % ≤ 2.0

Core/Cladding

Concentricity Error µm ≤ 3.0

Trang 3

3 CABLE CONSTRUCTION

The construction of the cable shall be in accordance with Table 2 below

Table 2 Construction of the Cable

ITEMS DESCRIPTION

Number of Fibers 6 Core

Type of Fiber 50/125um Multi Mode

Loose Buffer Tube PBT (Polybutylene Terephthalate)

Filling Compound

in Central Tube Thixotropic Jelly Compound

Water Blocking Material Water Swellable Yan or Water Swellable Tape (if necessary)

Strength Member Glass Yarn or Aramid Yarn

Material LSZH Colour Grey Outer Jacket

Thickness Nom 1.0mm

4 FIBER IDENTIFICATION

The color code of the central tube and the individual fibers within central tube shall be in

accordance with Table 3 below

Table 3 The Color Code of the Individual Fibers

No of Fibers Color No of Fibers Color

1 Blue 13 Orange / Single Ring Stripe*

2 Orange 14 Green / Single Ring Stripe*

3 Green 15 White / Single Ring Stripe*

4 Brown 16 Yellow / Single Ring Stripe*

5 Grey 17 Pink / Single Ring Stripe*

6 White 18 Aqua / Single Ring Stripe*

7 Red 19 Orange / Double Ring Stripes**

8 Black 20 Green / Double Ring Stripes**

9 Yellow 21 White / Double Ring Stripes**

10 Violet 22 Yellow / Double Ring Stripes**

11 Pink 23 Pink / Double Ring Stripes**

12 Aqua 24 Aqua / Double Ring Stripes**

Trang 4

5 PHYSICAL / MECHANICAL / ENVIRONMENTAL

PERFORMANCE AND TESTS

5.1 Temperature Range

For the cables covered by this specification, the following temperature ranges apply:

- Operation : -20°C to +60°C

- Installation : -5°C to +50°C

- Storage/Shipping : -25°C to +70°C

5.2 Mechanical and Environmental Performance of the Cable

The mechanical and environmental performance of the cable shall be in accordance with

Table 4 below Unless otherwise specified, all attenuation measurements required in this

section shall be performed at 1300nm for multi mode fiber

Table 4 The Mechanical and Environmental Performance of the Cable

ITEMS ACCEPTANCE CRITERIA TEST METHOD AND

Tensile Loading

And Bending Test

# Test method: TIA/EIA-FOTP-33 - Mandrel diameter: 30D (D = cable diameter) - Tensile load: 1,800N for 1 hour

# Acceptance Criteria - Fiber strain: Less than 60% of the fiber proof strain - Attenuation increment: ≤ 0.30 dB at 1300nm

Compressive Loading

Resistance Test

# Test method: TIA/EIA-FOTP-41 - Applied load: 2200 N/100mm - Duration of loading: 10 minutes

# Acceptance Criteria - Attenuation Increment: ≤ 0.20 dB

after the completion of the test

Water Penetration Test

# Test method: TIA/EIA-FOTP-82 - Length of specimen: 3m - Height of pressure head: 1m - Test time: 24 hours

# Acceptance Criteria - No leakage through the open cable end

Flammability Test

(LSZH Jacket Cable only)

# Test method and Acceptance Criteria The cable shall comply with IEC 332-1

Trang 5

Table 4 The Mechanical and Environmental Performance of the Cable ( continued )

ITEMS ACCEPTANCE CRITERIA TEST METHOD AND

Repeated Impact Test

# Test method: TIA/EIA-FOTP-25 - Height of impact: 150mm - Drop hammer mass: 2.0kg - No of impact cycles: 20 cycles

# Acceptance Criteria - Attenuation Increment: ≤ 0.20 dB

after the completion of the test - No jacket cracking and fiber breakage

Cyclic Flexing Test

# Test method: TIA/EIA-FOTP-104 - Sheave diameter: 20D (D = cable diameter) - No of flexing cycles: 25 cycles

- Flexing speed: 30 cycles/minute

# Acceptance Criteria - Attenuation Increment: ≤ 0.20 dB - No jacket cracking and fiber breakage

Cable Twist Test

# Test method: TIA/EIA-FOTP-85 - Cable length twisted: 2m - No of twist cycles: 10 cycles - Twist angle: ± 180˚

# Acceptance Criteria - Attenuation Increment: ≤ 0.20 dB - No jacket cracking and fiber breakage

Temperature Cycling Test

# Test method: TIA/EIA-FOTP-3 - Temperature cycling schedule : 23°C → -20°C → 65°C → -20°C → 65°C - Soak time at each temperature: 24hours - No of cycles: 2 cycles

# Acceptance Criteria - Attenuation increment:

⋅ Average ≤ 0.20 dB/km ⋅ Maximum ≤ 0.30 dB/km

6 PACKING AND MARKING

6.1 Cable and Length Marking

The jacket shall be indent-marked with white characters at intervals of one meter with

following information Other marking is also available if requested by customer

1) KRONE

2) Cable type and fiber number

3) Year of manufacture

4) Length marking

Trang 6

6.2 Cable Re-marking

The re-marking shall be indent-marked, preferably with yellow characters, on the outer

cable sheath Any cable that contains two sets of cable markings shall be marked to

indicate the color of the marking to be used

6.3 Cable Packing

6.3.1 Standard length of cable shall be 2000 m Other cable length is also available if

requested by customer

6.3.2 Each length of the cable shall be wound on a separate wooden reel

6.3.3 Both ends of the cable shall be sealed with suitable plastic caps to prevent the entry of

moisture during shipping, handling and storage

6.3.4 The cable ends shall be securely fastened to the reel to prevent the cable from

becoming loose in transit or during placing operations

6.3.5 The inner end of the cable is housed into a slot on the side of the reel without extra

cable length for testing

6.3.6 Circumference battens or wood-fiber board shall be secured with steel bands to protect

the cable during normal handling and shipping

6.4 Cable Reel

6.4.1 Details given below shall be distinctly marked on a weather proof materials on both

outer sides of the reel flange:

(1) KRONE

(2) Length of cable in meters

(3) Cable type and fiber counts

(4) Gross weight in kilograms

(5) Reel number

(6) Year of manufacture

(7) Arrow showing the direction the drum shall be rolled

6.4.2 The cable shall be wound on the reel designed to prevent damages during shipment

and installation

6.4.3 The arbor holes provided in the reels shall be at least 65 mm and at most 120 mm in

diameter The arbor hole on each flange shall be reinforced with a bearing plate

Trang 7

< Cross-sectional Drawing of Cable >

== End of Specification ==

24 Fibers

Optical Fibers Jelly Compound Central Tube Dielectric Strength Member Ripcord

Outer LSZH, Grey Jacket

Ngày đăng: 18/10/2013, 13:15

TỪ KHÓA LIÊN QUAN