Migrating to IHO certificate for S-63 1.1 2To install S-63 1.1 Data the latest IHO certificate Public Key will need to be installed in your ECDIS.. To install it please insert the S-63 1

Trang 1

Migrating to IHO Public Key for S-63 1.1 in Furuno ECDIS

This guide is based on the Furuno FEA 2107/2807 ECDIS Version 06.21

Trang 2

Migrating to IHO certificate for S-63 1.1 2

To install S-63 1.1 Data the latest IHO certificate (Public Key) will need to be installed in your ECDIS The IHO.PUB is located on any AVCS S-63 1.1 Media To install it please insert the S-63 1.1 Media into your ECDIS and follow the steps below:

Note: Furuno ECDIS use the IHO.PUB not the IHO.CRT

To load the IHO.PUB Certificate:

1 Select ‘Chart Permits’ from the ‘Chart Menu’ window

2 Select ‘Public Key’

1 Migrating from PRIMAR.PUB to IHO.PUB

Trang 3

Migrating to IHO certificate for S-63 1.1 3

3 The installed Public Key will then be displayed Select ‘Load New’

4 On ‘Public Key Load’ window, select the Drive where the

Public Key is stored

5 Highlight the IHO.PUB Public Key to be installed

6 Click ‘Load’

7 A new ‘Public Key’ window will then be shown displaying the IHO.PUB Public Key file This will not overwrite the currently installed Public Key until the user clicks on ‘Accept New’

The IHO.PUB is then installed and S-63 1.1 data can be loaded into the ECDIS

Trang 4

Migrating to IHO certificate for S-63 1.1 4

2 Reverting to PRIMAR.CRT

If for any reason the migration to S-63 1.1 fails then the PRIMAR.PUB file will need to be re-installed To do this you will need to obtain a copy of the PRIMAR.PUB If you do not already have a copy then please contact UKHO customer services (customerservices@ukho.gov.uk) who will be able to supply this to you

Once received please follow exactly the same process as outlined above however this time browsing to the

location of the PRIMAR.PUB

Your system will now be in the same state as before attempting the upgrade and you can continue to use

AVCS S-63 1.0 data However, you should inform your Admiralty Chart Agent of the problems that you

have encountered

UKHO 2013 All Rights Reserved