2010-04-21 ©SKF Slide 3 [Code] GX Series Microlog System Overview host computer host computer with Machine Analyst software GX Series - Microlog pre-configured meas... 2010-04-21 ©SKF S

Trang 1

Introduction to the

2010-04-21 ©SKF Slide 1 [Code]

Trang 2

2010-04-21 ©SKF Slide 2 [Code]

Module Objective(s)

To familiarize new GX Series users with the overall Microlog system, its hardware functionality, and its terminology.

Trang 3

2010-04-21 ©SKF Slide 3 [Code]

GX Series Microlog System Overview

host computer

host computer with

Machine Analyst software GX Series - Microlog

pre-configured meas.

collected meas data

Trang 4

GX Series - Microlog “Application Modules”

2010-04-21 ©SKF Slide 4 [Code]

GX-S only

application module icons

Trang 5

2010-04-21 ©SKF Slide 5 [Code]

Application “Modules”

Route Mode – for collecting

ROUTE measurements

downloaded from SKF Machine

Analyst host software

Balancing Mode – resolves

single-plane, two-plane, and

static-couple balances with high

precision.

Review Mode – for reviewing measurement data

stored in the Microlog’s memory.

Non Route Mode – for collecting

measurement data for POINTs not

previously downloaded from Machine

Analyst software.

Setup Mode – for setting your

Microlog’s system preferences.

Bump Test Mode (-S only) –

determines the natural frequencies of a machine or a structure.

Recorder Mode (-S only) –

records one or two channel raw

vibration signals (time waveforms)

as Microsoft Windows wav audio

files

Two Channel Mode – two channel

measurements available from Non-

Route / Orbit and Non Route / User

defined meas modes.

Trang 6

2010-04-21 ©SKF Slide 6 [Code]

Data Collector Input

Sensor based data input from:

Trang 7

• Ensure Good Visibility

• Follow General Plant and Electrical Safety Practices

• Common Sense is Your Best Safety Protection!

Trang 8

Machine Analyst Host Software

2010-04-21 ©SKF Slide 8 [Code]

Trang 9

Component Use Sequence

2010-04-21 ©SKF Slide 9 [Code]

1 - Use Machine Analyst (MA)

software to set up your

database of measurement

POINTs

3 - Use the Microlog to walk the ROUTE and collect measurement data

2 – Download the configured measurement POINTs to the

GX Series Microlog

4 – After data collection, upload the collected measurement data to MA

5 – Use MA to identify machines with abnormal conditions

6 – Use MA to trend, analyze,

report, store, and share machinery

condition measurement results

download meas setups

upload collected data

Trang 10

2010-04-21 ©SKF Slide 10 [Code]

Battery Charging Overview

• USB/Power “Splitter Cable”

provides connections between

the Microlog, the Power

Adapter/Battery Charger, and

an external device’s USB

communications port.

• First time battery use - charge

for five hours minimum

Subsequent charges require 3-

5 hours.

• Typical battery life is 6-8 hours

in standard operations

power connecto

r

Trang 11

2010-04-21 ©SKF Slide 11 [Code]

Battery Replacement Sequence

Replacing the battery in an Active Microlog:

Press the Power button to suspend the Microlog.

• Un-latch the battery and remove the pack

• Replace with a fully charged battery pack and re-latch

Press the Power button

Trang 12

2010-04-21 ©SKF Slide 12 [Code]

Battery Status Display

Good – Approximately 45% or more of battery life

remains (i.e., approximately 4 hours or more of

normal usage).

Low - Less than 45% of battery life remaining,

charge the battery as soon as possible.

Critical – Very limited battery life remaining (less

than 30 minutes) Charge the battery

immediately, it is not recommended to continue

work when the battery status is Critical.

Battery status is displayed in the screen’s status line, or press the decimal key (.) to display battery status

Trang 13

2010-04-21 ©SKF Slide 13 [Code]

Battery Safety!

Danger of explosion if battery is incorrectly replaced!

Do not expose the battery pack to temperatures in excess of 140° F (60° C).

Do not disassemble, incinerate, or short-circuit the battery pack.

Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used

batteries according to the manufacturer’s instructions

Do not open battery compartment in a hazardous area!

Trang 14

2010-04-21 ©SKF Slide 14 [Code]

Buttons and Keypad

2 Enter Buttons – select the

highlighted option, or progress through data collection screens

4 Function Buttons – context

sensitive, allow quick access to often used Microlog features

LCD Indicators – show

measurement status during data collection

Power Button - Press to turn on

GX, press and hold several seconds to turn off GX

Alphanumeric Keypad – input

both numbers and letters

Shift Button - provides alternate

functions for the four function buttons

Arrow Buttons – select items on

screens, left/right arrows

open/close setup fields, control

plot cursor/display options

Decimal Key (.) – displays battery

status

Trang 15

2010-04-21 ©SKF Slide 15 [Code]

Function Buttons

current functions of function buttons

• Press function buttons to

execute commands

represented above each

button

• Commands are context

sensitive, they update

depending on screen

activity

• Press “shift” button (0 / up

arrow button) to view

additional functions

shift function button

Trang 16

2010-04-21 ©SKF Slide 16 [Code]

Entering Letters from Keypad

• To input letters, repeatedly

press the number key

representing the specific letter

2, 3, or 4 times

For example, for B, press the

2 key 3 times (2-A-B) This

works in a similar manner to a

cell phone’s text entry

capability

• To enter a blank space, press

the 0 key twice

Trang 17

2010-04-21 ©SKF Slide 17 [Code]

LCD Indicators

Data collection is occurring.

Data collection is complete;

measurement results are not in alarm

Data collection is complete;

measurement results are in alarm

Data collection is occurring; settling is taking longer than expected.

Data collection is taking longer than expected; the GX Series may be experiencing a settling problem

Measurement results may be invalid.

Trang 18

input channels, and

for a trigger input

CH2 – Channel 2, input

capabilities for Y and Z signal input channels, and for a trigger input

Power - Connect to Power

Supply/Battery Charger When power is not being supplied to the unit, available for Trigger input or for USB

Trang 19

2010-04-21 ©SKF Slide 19 [Code]

Communications Overview

RS-232 Serial Communications – Machine Analyst software upload / download operations utilize only RS-232 serial communications

USB / IrDA Communications – GX Series upgrade modules and

operating system upgrades may be installed using Microsoft

ActiveSync and the RS-232, USB, and IrDA connectors, or using a

PC card

GX Series display screens may be printed to RS-232 and IrDA

supported printers

Trang 20

2010-04-21 ©SKF Slide 20 [Code]

ActiveSync Overview

• Connects Windows® CE device (GX) to desktop PC

• Free download from Microsoft® - www.microsoft.com

• Run “setup.exe” program and follow instructions to install

• Synchronizes files between the GX and desktop PC

• After setup, initiates automatically when USB cable is connected between Microlog and desktop PC

• Allows Windows Explorer® file transfer operations between the

GX and desktop PC

Trang 21

2010-04-21 ©SKF Slide 21 [Code]

Printing Microlog Screens

• Print the current display screen using the RS232 connector or the IrDA port (for printers with IrDA support)

Press the shift key (zero / up arrow) then the P alphanumeric key The Print Setup dialog displays Options include:

Printer – Specify either a PCL or PocketJet 200 printer.

Baud Rate – Specify the baud rate for RS232 connection, or IrDA if applicable Size – Specify the size of the screen print-out Medium is approximately one-to-

one with the GX screen size.

After setting up print options, press the OK function button to print

the current display

Trang 23

2010-04-21 ©SKF Slide 23 [Code]

GX Series accepts any standard ATA flash memory card or any Type I or Type II card that is supported with a Microsoft Windows® CE driver

PC Card Advantages:

• Provide greater memory for ROUTE storage.

• PC cards are portable, which is efficient in plants with more than one Microlog.

• Independent ROUTEs can be stored on different PC cards

For hazardous areas, you must use a PC card manufactured by

Simple Technology, model numbers STI-ATAFL/8A to STI-ATAFL/512.

PC Memory Card Operations

Trang 24

2010-04-21 ©SKF Slide 24 [Code]

How to Perform a Hard Reset

A hard reset will not delete data or ROUTEs.

With the Microlog OFF, unscrew the battery cover on the back of

the unit

• Using a 1/16th inch pin or a straightened paper clip, press the reset button located in the lower left corner of the battery compartment, below the battery

• The LCD screen loads the SKF title screen, then the main screen

Trang 25

2010-04-21 ©SKF Slide 25 [Code]

Microlog Terminology

ROUTE SET

Machine

Measurement POINT

GX Series Microlog ROUTE

hierarchy

Machine Analyst ROUTE hierarchy

Trang 26