What is a ROUTE?A list of measurement POINTs arranged in a sequence that facilitates the most efficient data collection path through your plant / mill.. • Created in MA and downloa
Trang 1ROUTE Mode
Trang 2Module Objective(s)
To instruct the new GX Series Microlog user on how to collect ROUTE measurement data.
Trang 3What is a ROUTE?
A list of measurement
POINTs arranged in a
sequence that facilitates
the most efficient data
collection path through
your plant / mill.
• Created in MA and
downloaded to the Microlog
• right arrow opens and
progresses down the
ROUTE hierarchy
• left arrow closes and
retreats up the hierarchy
active route
active route’s hierarchy
active meas
point
active point’s
“description”
Trang 4How to Select a ROUTE
• If necessary, use the left arrow to
make ROUTE hierarchy level
active, all ROUTEs display.
• Use up/down arrows to highlight the
ROUTE to make active.
• Use the right arrow to select and
progress into the highlighted
ROUTE
• At any time, press an Enter button
on any non-POINT hierarchy item to
begin data collection for the next
POINT in the list (after the
highlighter pointer)
two routes
Trang 5ROUTE Hierarchy Overview
“sets” help organize machines
“machines” contain only measurement POINTs
active meas
point
initiate non ROUTE mode for in-the-field analysis
Trang 6The “Auto Advance” Setting
On – do not
show spectrum, auto advance to next POINT
Off – show
spectrum
Trang 7Initiating Data Collection
select POINT
and press Enter
button
Trang 8Spectral Measurement Display
overall vibration
value
cursor
meas units
frequency and amplitude at cursor position
add coded note(s)
re-take meas
• Press Enter to save
meas data and
advance to next
meas.
do not save meas data
real time - no interruption in data
samples
Trang 9Applying Analysis Features
Y-axis scaling
T key – phase
“tables”
+/- key – display expansion / compression
“.” key – immed toggle
between display expansion and display
P key - jump to next peak
H key - display harmonic
markers
Trang 10How to View POINT Setup Information
Trang 11Time Waveform Display
overall vibration
value
cursor position and amplitude
• Press Enter to save
meas data and
advance to next meas.
arrow “analysis” keys
are available as with
spectral displays
Trang 12Process Measurement Display
full scale value alarm setpoint
previous reading current reading
current reading
previous
reading and
change from
previous
perform manual
data entry using
keypad
Trang 13Quick Review