Vibration: a measure of reliability!Poorly installed and operated pumps average .178 in/sec overall vibration and have 6 months life.. Properly installed pumps average .071 in/sec overal

Trang 1

Centrifugal Pump Vibrations:

The Causes

by Steven J Hrivnak, P.E.

Associate Mechanical Engineer

Tennessee Eastman Eastman Chemical Company

EASTMAN

Trang 2

FAULTS REPORTED OVER 3 YEARS

Trang 3

Vibration: a measure of reliability!

Poorly installed and operated pumps average

.178 in/sec overall vibration and have 6 months life.

Properly installed pumps average

.071 in/sec overall vibration and have 60 months life.

EASTMAN

Trang 4

Three Basic Causes of Pump

Vibrations:

Mechanically Induced

System Induced

Operation Induced

Trang 8

System Induced

Partially/Plugged Strainer

Clogged Impeller or Suction Line

Installation

Trang 9

PIPING?

Trang 14

and Baseplates

Trang 15

The mass ratio must be 3:1 to

minimize vibration

Trang 25

Cavitation and Flow

Trang 27

High Temp Rise

Low Flow Cavitation

Low Bearing and Seal Life

Reduced Impeller Life

Trang 33

You can’t run a pump with suction

and discharge valves closed!

Trang 35

Minimum Flow

1750 rpm 15-20% BEP Flow

3500 rpm 30-50% BEP Flow

Trang 36

Maximum Flow

110-115% BEP Flow

Trang 41

Speed

Trang 44

Suction Pipe Immersion

Trang 47

Avoid Max Size Impellers

Conclusions

Trang 48

Avoid Max Size Impellers

Keep speed to 1750 max

Conclusions

Trang 49

Avoid Max Size Impellers

Keep speed to 1750 max

Keep flow in design range

Conclusions

Trang 50

Avoid Max Size Impellers

Keep speed to 1750 max

Keep flow in design range

Grout your baseplates

Conclusions

Trang 51

Avoid Max Size Impellers

Keep speed to 1750 max

Keep flow in design range

Grout your baseplates

Use proper piping

Conclusions

Trang 52

Avoid Max Size Impellers

Keep speed to 1750 max

Keep flow in design range

Use proper piping

Avoid hydraulically induced problems like

cavitation, and suction and discharge re-circulation, submergence.