Distance Dialog Window UserSetup Date: Jan... Outline A new way to measure the minimum distance between two selected tools in the “normal’ direction was added... Description In previo
Trang 1Add Normal Option in Min Distance Dialog Window
UserSetup
Date: Jan 21th, 2014
Trang 2Outline
A new way to measure the minimum distance between two selected
tools in the “normal’ direction was added
Trang 3Description
In previous versions, there were three directions to
measure the minimum distance between two selected
tools The three directions were: Along the X direction,
along the Y direction and along the Z direction
In DF 5.9.2, the ability to measure along the Normal
direction, between the two selected tools, was added See
the figure to the right
Select Master Tool, Slave Tool and Normal direction, and
the distance is displayed in the message prompt area, as
shown below
Trang 4Figure 1
Figure 2
1. Start up DYNAFORM 5.9.2 and open the included df file named
UserSetup_Srail.df See Figure 1
2. Click UserSetup-> Position Tools/Min Distance See Figure 2
3. The dialog window Min Dis between Tools will open See Figure 3
Figure 3
Trang 5Figure 4
Figure 5
4. Select Master Tools: DIE, and select Slave Tools: PUNCH See Figure 4
5. Select Direction Normal, as illustrated in Figure 4
6. The minimum distance in the Normal direction will be displayed in the dialog
window and displayed in the message prompt area See Figure 5
MINIMUM DISTANCE BETWEEN DIE - PUNCH
IN Normal = 41.996