35 7.1 H ORIZONTAL ANGLE MEASUREMENTS RIGHT CORNER MODE .... 1.Instrument features Our products DT-02 series Electronic Theodolite and laser Electronic Theodolite, absolute encoder ang
Trang 1Contents
1.INSTRUMENT FEATURES 4
2.QUICK GUIDE 5
2.1 I NSTRUMENT PACKING 5
2.2 N AME OF INSTRUMENT PARTS 6
2.3 U NPACK AND STORAGE 8
2.4 H ANDLING , INFORMATION AND CHARGING OF THE BATTERY 9
2.5 I NSTALLATION OF THE INSTRUMENT 12
3.INSTRUMENT OPERATION KEYS AND DISPLAY INSTRUCTIONS 13 3.1 K EYBOARD SYMBOLS AND FUNCTIONS 13
3.2 LCD 15
4.PARAMETER SETTINGS 17
5.PREPARING FOR MEASUREMENT 19
5.1 I NSTRUMENT PLACEMENT , CENTERING AND LEVELING 19
5.1.1 Plumb bob on leveling 19
5.1.2 Use the plummet for centering 22
5.2 T ELESCOPE EYEPIECE ADJUSTMENT AND TARGET SIGHTING 23
Trang 25.3 S WITCH O N AND O FF 25
6.BASIC MEASUREMENT 26
6.1 D ISC / DISK LEFT RIGHT SWITCH 26
6.2 S ET H ORIZONTAL ANGLE TO ZERO 27
6.3 A NGLE LOCK 28
6.4 T HE VERTICAL ANGLE MODE SWITCH 29
6.5 I NTO THE SWITCHING STATE 30
6.6 L IGHTING O PEN C LOSE 31
6.7 S WITCH AT RIGHT ANGLES TO BEEP 31
6.8 S WITCHING COMPENSATOR 32
6.9 O UTPUT ANGLE DATA 33
7.ANGLE MEASUREMENT 35
7.1 H ORIZONTAL ANGLE MEASUREMENTS ( RIGHT CORNER MODE ) 35
7.2 H ORIZONTAL ANGLE MEASUREMENTS ( LEFT CORNER MODE ) 36
7.3 V ERTICAL ANGLE MEASUREMENT 37
8.DATA RECORDING AND TRANSMISSION FUNCTION 38
Trang 39.1 L ASER POINT TO OPEN AND CLOSE 40
9.2 L ASER POINTING 40
10.CHECKOUT AND CALIBRATION 42
10.1 L EVEL TUBE 42
10.2 C IRCULAR LEVEL 43
10.3 T ELESCOPE RETICLE 44
10.4 T HE VERTICALITY OF COLLIMATION AXIS AND HORIZONTAL AXIS (2 C) 46 10.5 V ERTICAL COLLIMATION ERROR (I A NGLE ) AND VERTICAL COLLIMATION ZERO VALUE SETTING 47
10.6 C HECKING AND CORRECTION OF VERTICAL DIAL COMPENSATOR 49
10.7 P LUMMET 52
11 SPECIFICATIONS(ELECTRONIC THEODOLITE) 55
12.SPECIFICATIONS (LASER ELECTRONIC THEODOLITE) 57
13.ATTACHMENT 59
Trang 41.Instrument features
Our products DT-02 series Electronic Theodolite and laser Electronic Theodolite, absolute encoder angle measurement, eliminating the vertical plate angle initialization process, easy to operate; Large-diameter objective lens system for easytargeting operation; Nice, reasonable structure and ergonomic design; Fully functional, suitable for a variety of applications theodolite angle measurement; collection of data can be done directly
through the serial port output; simple button operation, only six function keys can achieve a variety of measurement functions; big screen, clear font; display backlight reticle illumination for dark environments operation; laser point instead ofoptical vertical quasi use
is easier than the optical; convenient laser t
Trang 52.Quick Guide
2.1 Instrument packing
Note: During the instrument packing, loosen the stopper body!
Trang 62.2 Name of instrument parts
Trang 8Note: only in the back of the instrument model decorated with the letter L theodolite is laser theodolite
2.3 Unpack and storage
Unpack
Put down the instrument box lightly, so that the lid upward to open the latch of the box, open the lid and remove the instrument
Storage
Telescope vertically down (or up), so tha
t the alidade base of packing marks are align
ed, marked the instrument packing up supine into the box and gently tighten the vertical automatic knob cover box cover and lock the case
Trang 92.4 Handling, information and charging of the battery
Battery handling
Remove the battery box, battery box at the top of the button is pressed outwards pul
l out at the top of the battery box
When install the battery box the bottom of the battery compartment first projection is inserted into the groove on the instrument, press the top button of the battery compartment, so that
it snaps into the instrument fixed homing
Battery Information
Continuous work for 8 ~ 10 hours in full battery, Symbol in the lower left corner " " display battery consumption, the battery consumption is as follows:
“ ” and “ ”: Fully charged and operable
“ ”: this information, means there is a small amount of power, should be ready to replace the battery or charging before use
Trang 10 “ ” lack of power, it will shut down about sustainable few minutes, replace the battery and charging right now
Charging
rechargeable battery, please use the ZY-4Q500 dedicated charger
For charging, connect 220v power supply first, the red light flash, the charger plug into thecharging connector socket, push the battery into the charging deck, red light means charging started, charging six hours or charging lights turn green means the end of charge, pull out the battery
Warning: If the battery is placed improperly (such as positive and negative terminal), may cause an explosion, please follow the
Trang 11 Do not charge the battery before it have not been used or not spent much time on the repeated charge after fully charged, it will shorten the battery's life
Charging in the temperature range of 0 ° ~ +45 °, and beyond this range may cause charging abnormality
Do not use any charger or battery that had been damaged
Storage Precautions:
The rechargeable batteries are rechargeable about 300-500 times, fully discharge the battery will shorten its life
For better access to the longest battery life, Please ensure that charged once a month
Do not store the battery in high-temperature, high heat or humid places, not to short-circuit the battery, otherwise it will damage the battery
Properly dispose of the battery according to local rules, better recovery, do not throw the
Trang 12Install
Align at instrument directional bulge mark and substrate directional groove , Three fixed foot on instrument corresponding to in hole in substrate, Install instrument on three substrate lock twist of about 180 ° clockwise
Trang 133.Instrument operation keys and display instructions
3.1 Keyboard symbols and functions
Trang 14horizontal angle left and right corner
of the vertical angle, the inclination
Compensator correct
switcher
angle lock
Display backlight switcher
4 0 SET Set horizontal
angle to zero
Horizontal angle right angle buzzer switcher
switch
data, confirm
Trang 153.2 LCD
The LCD is divided into four lines:
The first line Instrument Number Initialization has been completed in the factory of the instrument, can not be changed
The second line vertical angle XXX° XX' XX" said the angle of the " degree every minute units; Display for the GON unit angle XXX.XXXX g; show for XX.XXXX% slope
The third line horizontal angle The lower right corner of the word "R" for
0 0 0 0 0 0 1
VA 90°15’15”
HAR 190°15’15”
TITL HOLD
Trang 16theright corner of the mode, increased clockwise rotation instrument angle; upper right corner of the word "left" means Left angle mode, counterclockwise rotation Instruments will cause angle increase
The fourth line Electricity flag; Other “Direction”, “Point”, “Switch”,
“Compensation”, ”lock” logo will display with the corresponding function on
Trang 174.Parameter settings
The instrument can set a number of systemparameters and they are automatically saved when the set is completed
In the off state, press the【L/R】+【0 SET
】 key, then press the power button boot, you can enter the system parameter setting mode
On the screen of display 10 digit is either
"0",or "1", each figure or two figures represent the meaning below
Flashing digital can change.【L/R】 keys move left;【V/%】key is moved to the right;
【0 SET】 key to switch parameters between 0 and 1
After Setting the parameters, you can click
0000001
0001000
001
Trang 18parameters work
Parameters described in the following table:
Trang 195.Preparing for measurement
5.1 Instrument placement, centering and leveling
Instrument mounted on a tripod, precise leveling and alignment to ensure the precision of the measurement results
5.1.1 Plumb bob on leveling
1 Set up the tripod
Setup the tripod first: extend the extension legs to suitable lengths and tighten the screws
on the mid sections Make sure the legs are spaced at equal intervals and the head is approximately level Set the tripod so that the head is positioned over the surveying point Make sure the tripod -11-shoes are firmly fixed in the ground
Trang 202 Mount the instrument on the tripod head
Mount the instrument on the tripod head Supporting it with one hand, tighten the centering screw on the bottom of the unit to make sure it is secured to the tripod
3 Centering and Leveling-Up
1 Position tripod legs so that the plummet is aimed to the ground mark point Turn the focusing ring of the optical plummet to focus
2 Turn three foot screws of the tribrach till the center of reticle exactly coincides with the surveying point in any position
3 Move the tripod legs to centre the circular level The instrument is now roughly leveled-up
4 Center the bubble in the circular level
(1)
Trang 21(2)
5 Center the surveying point again
Loosen the centering screw slightly Looking through the optical plummet eyepiece, slide the instrument over the tripod head until the
Trang 22surveying point is exactly centered in the reticle Re-tighten the centering screw securely
6 Check again to make sure the bubble in the plate level is centered If not, repeat procedure4
5.1.2 Use the plummet for centering
2 Mounting and centering
Trang 23the instrument, Pres 【 】 to open
“Direction” light (Only for laser theodolite), Press 【 】again to open laser “Point”, we can see the red laser to the ground out from the base down Through the laser we can adjust the position of the tripod point observation So that the next point roughly aims at the station, make all three legs are fixed on the ground Adjust the instrument three foot spiral to the point precisely to the measurement site
3 Do centering and leveling work again refers to
chapter 5.1.1 step 3 to step 5
5.2 Telescope eyepiece adjustment and target sighting
Eyepiece adjustment
1 Remove the telescope mirror cover
2 Pointing to the sky through the telescope,
adjusting the eyepiece knob, the most clear reticle crosshairs
Trang 24Object Sighting
1 Sight to the target with the crude sight
2 Adjust the telescope focusing knob until the
object can been seeing clearly
3 Tighten the horizontal and vertical brake knob,
fine-tune the two micro knob to accurately sight the center of the crosshair to target, move eye up and down for slightly observe,
if the relative shift between the two images of the target with the crosshairs, then fine-tune the telescope focusing knob until the two images clear and relatively stationary ended
Clockwise rotation of the focusing knob to closer to the target Rotate counterclockwise for contrary
If step (3) is not adjusted well, the parallax will distort the relationship of the target with the reticle center, then leading to the
Trang 25the rotation is too far, we’d better return and re-sighting knob rotates clockwise
Even if the eventuality vertical angle, we still recommend to sight the target as far as possible with the position of the center of the crosshairs
5.3 Switch On and Off
Switch On
Operation: Click 【 】 button to boot, after boot it will display the surveying interface
Switch Off
Operation: Press 【 】 for 3 seconds, See
on the screen as shown below with the word
"0.FF", you can release the button, the instrument is turned off
0000001
VA 0 F F
HA R 190°15’15”
TILT
Trang 27measurement mode "left corner" mode, means counterclockwise rotation cause angle increases
3 Press【L/R】key to return to the right corner measurement mode
6.2 Set Horizontal angle to zero
Click the【0 SET
】 key, buzzer after the
Trang 28key again, the
locking angle will
be the current set
Trang 296.4 The vertical angle mode switch
key, vertical angle
will switch to the
Trang 306.5 Into the switching state
the key for the
first function and
Trang 31back to the first functional status
6.6 Lighting Open Close
1 Click 【SHIFT】 key, the function keys to enter the second functional state
2 Click 【HOLD】 key, then open the screen backlight and reticle illumination
3 Click 【HOLD】 key, then turn off the screen backlight and reticle illumination
4 Click 【SHIFT】key, the function keys back
to the first functional status
6.7 Switch at right angles to beep
1 Click【SHIFT】key, the function keys to enter the second functional state
2 Click the【0 SET】key, then open the right angle buzzer, there will beep when the instrument horizontal angle Go around 90.180 270.0 degrees, allows you to easily find the desired location
Trang 323 And then click the【0 SET】key, then turn off the horizontal angle right angle buzzer
4 Click 【SHIFT】 key again, the function keys back to the first functional status
6.8 Switching compensator
This series theodolite with compensator can switch through switcher
1 Click【SHIFT】
key, the function
keys to enter the
Trang 33the angle mode or gradient mode, will not display properly
unless the instrument
not leveling, it will
show vertical angle
normally
Compensator correction switch is valid only
on the vertical angle
6.9 Output angle data
The instrument is equipped with a serial communications, data can be transferred to the
PC via the serial port
1 Click 【SHIFT】 key, the function keys to enter the second functional state
Trang 342 Connected to the instrument via the serial port to USB port cable with PC
3 Open a can receive serial data software
4 Set with the same instrument baud rate, 8 data bits, 1 stop bit, no parity
5 Each time you press【L/R】key instrument angle data transmission to the PC
6 Outgoing data format:
VXXX.XXXX + enter + newline VXXX.XXXX + enter + line feed
Outgoing data such as "V208.2323 \ r \ nH123.1212 \ r \ n",
Then it indicates that the current
The vertical angle of: 208°23’23”
Horizontal angle: 123°12’12”
Trang 352 Aim at the target
point A of the first
3 Click the【0 SET
Trang 36The first target A:
3 Aimed at a target point B
4 Click the【0 SET】key instrument horizontal
0000001
VA 90°15’15”
HA R 039°23’25”
TILT
Trang 376 The reading apparatus of the horizontal angle (a)
7.3 Vertical angle measurement
1 The instrument is installed on the site and boot after in leveling
2 The targeting point A
3 Vertical angle readout instrument
The vertical angle = 90 ° 15'15 "
Check the slope, click【V/%】key
0000001
VA 90°15’15”
HA R 039°23’25”
TILT
Trang 388.Data recording and
transmission function
8.1 Record the angle data
1 State angle measurement, click【SHIFT】 key
2 Each measurement is completed, you can click【 】key recording angle data, including horizontal and vertical angles, can record up
to 10 data
8.2 Data View and transmission
View
Holding【L/R】key and then press the【
】key after turning instrument on, the interface displays the current record number of angle data, the following figure shows there are 7 data