6 fiber softwall bundle Lucent 12 fiber ribbon 12 fiber softwall bundle Corning 12 fiber softwall bundle Lucent Pigtail or Adapter Type ACPG J PHRKY Adapters onlySoftwall bundle50/125So

Trang 1

® S tr

Introduction 230

FL2000 System 232

Preconfigured Panels 234

Empty Chassis 241

Connector Plug-Ins 244

Mounting Options 246

FPL Series Fiber Panels 248

1 Rack Unit FPL 250

Preconfigured Panels 251

High Density Panels 257

Fiber Management Tray 259

RMG Series Fiber Enclosures 271

Preconfigured Panels 274

Empty Chassiss 275

Modular Adapter Packs 276

Modular MTP/MPO Cassettes 278

WMG Series Wall Mount Enclosures 279

Wall Mount Fiber Enclosures 280

Modular Adapter Packs 282

Fiber Optic Specifications 284

Fiber Optic Patch Cords 285

Accessories 288

Fiber Optic Connectors 289

Trang 2

Proper cable management practices make fiber networks less susceptible to accidental damage, quicker to install, less expensive to own and operate over the long haul and easier to expand as needs grow To assure optimal network performance, ADC's fiber solutions fully incorporate key cable management concepts:

and added attenuation, which in turn affect the long-term reliability of the network and increase the cost of operations.

separate from heavier copper cables Routing paths through the cable troughs should be clearly defined and easy to follow, making access to individual fibers easier, quicker and safer, reducing the time required for reconfiguration.

Easy accessibility to installed fibers: Access to installed fibers should ensure that any fiber can

be installed or removed without inducing improper bends on adjacent fiber Accessibility is most critical during network reconfiguration operations and directly impacts the cost of operations and reliability of the network.

provides adequate support, cable protection and a transition from the vertical run to the back

of the equipment that does not damage the fiber.

Fiber Connectivity Solutions

Introduction Fundamentals of Fiber Cable Management

Trang 3

Rack Mount 19"/23"/ETSI 19"/23" 19"/23"/ETS 19"/23" No

Interface Type 6pak Angled Retainer

(left/right) Sliding Adapter Pack/Fixed

Bulkhead

LSX Compatible Adapter Pack LSX Compatible Adapter PackDegree of Cable

Allows

additional

growth

Quad LC

VAM

all front access, modular left angle 6paks

routers

Vertical cable guides, angled left/right adapters, highest density with maximum cable management features

termination storage is required

in 1 or 2 rack unit footprint

Completely enclosed drawer with easy access to fiber and high cable management and bend radius protection

Trang 4

FL2000 termination only chassis (door open) FL2000 termination/splice chassis (door open)

The economical and flexible FL2000 series of fiber optic products is ideal for small fiber counts and can be used in moderate fiber count applications as well by combining various panels.

Features

• Designed for 19-inch (48.26cm) EIA rack or cabinet environment; optional brackets are available to accommodate 23-inch (58.42cm) rack or cabinet mounting, or virtually any mounting application

• Modular design offers maximum flexibility to satisfy both current needs and future growth requirements

• A full line of options and accessories ensures compatibility with existing optical equipment

• All FL2000 panels accommodate the modular FL2000 6pak plug-ins 6paks are available in all connector styles and can be ordered as needed

• ADC’s patented removable angled retainers allow easy access for single fiber maintenance

• FL2000 panels and feature superior vertical cable protection and management

• Rack mount panels are hinged on one side, allowing full access to the rear of the front plate and the interior of the panel

• Rack mount panels can be wall mounted

• The new FL2000 splice wheel allows easy roll-up of pigtail and buffer tube lengths and superior bend radius protection

Trang 5

Maximum Density for

with ADC Glide?

Using glide is more difficult, as panels contain own vertical cable guide or VCG

Best Application Termination Splice

Features at a glance Locking or latching door, within panel splice wheel, all front access modular left

angle 6paks

Size in Rack Units

FL2000 Fast Facts

Trang 6

Number of Splice Decks

ABC

19" (48.26cm) standard (19.6" [49.78cm] overall) 19" (48.26cm) maximum (19" [48.26cm] overall) 19" (48.26cm) flush mount

Mounting Style 3

1 LC connectors and adapters double the capacity of the panel by terminating two fibers at each adapter.

2 For use with LC.

3 Mounting kit shipped unattached if other than standard mounting style

4 Singlemode choices for use with LC adapters, with multimode options ADC will automatically choose best suited fiber count.

5 ADC will automatically configure FL2000 panels with laser optimized cable to use aqua colored SC or LC adapters to indicate

10 Gigabit applications To order adapter only panels with aqua colored adapters, purchase the empty chassis and add 6paks separately.

6 fiber softwall bundle (Lucent)

12 fiber ribbon

12 fiber softwall bundle (Corning)

12 fiber softwall bundle (Lucent)

Pigtail or Adapter Type

ACPG

J

PHRKY

Adapters onlySoftwall bundle50/125Softwall bundle62.5/125 Softwall bundle50/125 laser optimized to550m5Softwall bundle50/125 laser optimized to300m5 6-fiber softwallbundle6-fiber Maxistrip12-fiber Ribbon412-fiber softwallbundle112-fiber Maxi-Strip4

Pigtail or Adapter Type

0MW2

None or N/AMechanical (Wheel)Heat ShrinkFusion (Wheel)Heat Shrink Fusion (Deck)

Splice Type

MN

Mechanical (Wheel)Nortel (Wheel)

Splice Type 2

Multimode

9D56

Singlemode

7E48

Singlemode

Multimode

SCDuplex SC

ST®

LC1Ultra PCSCDuplex SCUltra PCST

LC1

Features

FL2000 panels can also be shipped with 6paks and/or pigtails pre-installed at the factory

• Reduce installation time

• Simplify ordering processUse this configuration guide to determine the catalog number right for your application

Preconfigured Termination/Splice Panels, Black

Trang 7

7E48

Connector Style

1 LC connectors and adapters double the capacity of the panel by terminating two fibers at each adapter.

2 For use with LC

3 Mounting kit shipped unattached, if other than standard mounting style.

4 Singlemode choices for use with LC adapters, with multimode options ADC will automatically choose best suited fiber count.

5 ADC will automatically configure FL2000 panels with laser optimized cable to use aqua colored SC or LC adapters to indicate 10 Gigabit applications To order adapter only panels with aqua colored adapters, purchase the empty chassis and add 6paks separately.

FL2

-Catalog Number

1 2 3 0 4 5 6 7 0 8 - 0 9 10 11

ACPGJ

PHRKY

Adapters onlySoftwall bundle 50/125Softwall bundle 62.5/125Softwall bundle 50/125 laser optimized to 550m5Softwall bundle 50/125laser optimized to 300m56-fiber softwall bundle6-fiber Maxistrip12-fiber Ribbon412-fiber softwall bundle412-fiber Maxi-Strip4

01256

LatchHole PlugScrewdriverK1 LockK2 Lock

ABC

19" (48.26cm) standard (19.6" [49.78cm] overall) 19" (48.26cm) maximum (19" [48.26cm] overall) 19" (48.26cm) flush mount

Mounting Style 3

02

1 clamp (standard)

2 clamps

Number of Cable Clamps

SCDuplex SC

ST®

LC1Ultra PCSCDuplex SCUltra PCST

LC1

Features

FL2000 panels can also be shipped with 6paks

and/or pigtails pre-installed at the factory

• Reduce installation time

• Simplify ordering process

Use this configuration guide to determine the

catalog number right for your application

Preconfigured Termination Only Panels, Black

Trang 8

FL2000 panels can now be loaded with a bination of singlemode and multimode and/or pigtails pre-installed at the factory

com-• Panel available either horizontally or

vertical-ly loaded with like adapters with fulvertical-ly loaded configurations

• Reduces installation time

• Simplify ordering processUse this configuration to determine the catalog number right for you

Catalog Number FL2- 0 / -

Panel Type

C Vertically Loaded (left/right)

E Horizontally Loaded (top/bottom)

No of Cable Clamps

C Softwall bundle multimode 50/125

J Softwall bundle multimode 50/125 laser optimized to 300m

G Softwall bundle multimode 50/125 laser optimized to 550m

No of Spice Decks

0-8 Enter number of Splice Decks Needed

Horizontally loaded panel

1st conn style 1st adptr style 1st conn style 1st adptr style 2nd conn style 2nd adptr style 2nd conn style 2nd adptr style

Vertically loaded panel

1st conn style 2nd adptr style 1st conn style 2nd adptr style 1st conn style 2nd adptr style 1st conn style 2nd adptr style

Splice tray loading always follows loading style (vertical

or horizontal) i.e the first two 6 packs' pigtails will be routed to the top splice tray, the second two 6 packs' pigtails will be routed to the 2nd down splice tray

Trang 9

Used as an interconnect point for MTRJ connectorized

pigtails to allow for easy moves, adds, and changes.

ADC offers both MTRJ workstation and secure keyed jacks for

62.5/125 micron multimode applications Workstation jacks are

putty; secure keyed jacks are available in red, yellow, blue and

green The wall boxes and fiber panels come preconfigured

with the jack and retainer installed Ship along kits include the

following for each installed jack: 900 micron fiber guide, bend

limiting boot; actuator key.

MTRJ Pass Through Adapter

MTRJ Workstation and Secure

Keyed Jacks for Secure Network Applications

Ordering information follows on the next pages

Trang 10

FL2- 0 A 0 - 0 0

Catalog Number

Panel Type

R Termination only rack mount

Nominal Capacity/Panel Height

A 12-position black/1.75" (1RU)

B 24-position black/3.5" (2RU)

C 36-position black/5.25" (3RU)

D 48-position black/5.25" (3RU)

E 72-position black/8.75" (5RU)

F 96-position black/10.5" (6RU)

Adapter Style

M MTRJ (pass through adapters only)

S MTRJ workstation jack (putty)

B MTRJ secure keyed jack (blue)

G MTRJ secure keyed jack (green)

H MTRJ secure keyed jack (yellow)

W MTRJ secure keyed jack (red)

Pigtail or Adapter Type

B 19" maximum (19.0" overall)

Ordering Information

Trang 11

• Available with factory-installed multifiber

intrafacility cable (IFC) or OSP cable

• Panels with multifiber cable attached ship as

a single unit with cable clamp installed

• Panels come equipped with customer

specified number of adapters, retainers, connectors, cable type and cable length

• Panels with multifiber cable attached save

costly installation time

• Simplifies ordering process by allowing

one part number for the panel, adapters, connectors and cable

• Multiple mounting styles available

Fiber Panel Data

• Termination

• Preloaded with multifiber cable

Preconfigured Termination Panels with Multifiber Cable

Trang 12

B 19" (48.26cm) maximum (19" [48.26cm] overall)

C 19" (48.26cm) Flush Mount

Catalog Number FL2- 0 - 0 Panel Type

XXX Cable Length (meters)

Nominal Capacity Panel Height

2 Mounting kit shipped unattached

3 ADC will automatically configure FL2000 panels with laser optimized cable to use aqua colored SC or LC adapters to indicate 10 Gigabit applications To order adapter only panels with aqua colored adapters, purchase the empty chassis and 6pak separately

Connector Style Multimode

E IFC Stranded 50/125 laser optimized to 300m

Q IFC Stranded 50/125 laser optimized to 550m

R IFC Stranded Plenum 62.5/125

1 IFC Stranded Plenum 50/125

B IFC Stranded Plenum 50/125 laser optimized to 300m

2 IFC Stranded Plenum 50/125 laser optimized to 550m

Z Indoor-Outdoor Dry Loose Tube Plenum 62.5/125

3 Indoor-Outdoor Dry Loose Tube Plenum 50/125

4 Indoor-Outdoor Dry Loose Tube Plenum 50/125 laser optimized to 300m

5 Indoor-Outdoor Dry Loose Tube Plenum 50/125 laser optimized to 550m

Singlemode

A IFC Stranded

F IFC Stranded Plenum

G OSP Single Armor Stranded

H Indoor-Outdoor Stranded

J OSP Dielectric Stranded

K IFC Stranded Maxi-Strip

M IFC Ribbon Riser-Rated

L OSP Armored Ribbon

T OSP Dielectric Ribbon

Trang 13

Rack or cabinet mount panel, black

Includes vertical cable management

Wall mount bracket, black—needed

for 12 fiber capacity panel only

Cable clamp kit—One per cable

FL2-ACC008

FL2-ACC007 FL2-ACC021 FL2-ACC033 FL2-ACC006

Panel Height

1.75" (4.45cm) 3.50" (8.89cm) 5.25" (13.34cm) 5.25" (13.34cm) 8.75" (22.23cm) 10.50" (26.67cm)

24 fiber capacity

Mounting kits sold separately.

Empty Termination Panels, Black

Features

• Mounting

- 19" (48.26cm) EIA rack or cabinets, standard 5" (12.7cm) recess

- Wall mounting option available

- Other mounting kits available

• Hinged on left front side 1; allows full access

to rear of front plate and interior of panel

• FL2000 6pak adapter plug-ins ordered

separately

• Constructed of high strength aluminum

• Equipped with removable metal doors with

Plexiglas windows

• Designation labels included with each panel

• Complete line of accessories including locks

for security

1 Right hinged also available

Trang 14

O r d e r i n g I n f o r m a t i o n

Description Splice panel for splice wheel, black

(Accepts splice wheel only)

48 fiber capacity

96 fiber capacity

144 fiber capacity

Splice wheel with splice chip

Heat shrink fusion Mechanical Nortel

Splice panel for splice deck for existing installations, black

(Also accepts splice wheel)

3.5" (8.89cm) 7" (17.78cm) 8.75" (22.23cm)

Catalog Number

FL2-48SPNL2-B FL2-96SPNL2-B FL2-144SPNL2-B

FST-DRS12-HS FST-DRS12-MT FST-DRS24-NT

FL2-48SPNL-B FL2-96SPNL-B FL2-144SPNL-B

FL2-ACC007 FL2-ACC021

SPLICE CHIP(S) (HEAT SHRINK SHOWN)

SPLICE DECK

TOP SIDE

BOTTOM SIDE

CLEAR COVERS

Splice wheel with splice chip (black)

Splice deck with splice chip (black)

3.50" (8.89cm)

Mounting kits sold separately

• Occupies same footprint and offers same mounting options as FL2000 termination panels

• Accepts the ADC splice wheel for efficient management of fiber cable and splice protection

• Accepts the traditional ADC splice deck

Trang 15

Splice wheel with splice chip

Heat shrink fusion Mechanical Nortel

Catalog Number

FL2-12TS350-B

FL2-24TS525-B FL2-48TS875-B FL2-72TS140-B FL2-96TS175-B

FST-DRS12-HS FST-DRS12-MT FST-DRS24-NT

Panel Height

3.5" (8.89cm) 5.25" (13.34cm) 8.75" (22.23cm) 14" (35.56cm) 17.5" (44.45cm)

(25.76 cm) 4.95"

- Wall mounting option available

- Other mounting kits available

• Hinged on left front side 1 for complete access

to interior of termination section

• Ability to quickly and easily configure,

utiliz-ing the 6pak assemblies (ordered separately)

• Complete line of accessories including locks

for security

• Uses ADC splice wheels or splice decks

1 Right hinged also available

Trang 16

6pak Connector Plug-Ins With Adapters and Pigtails

Fiber Connectivity Solutions

StrandedMaxi-Strip

Length (in meters)

03W05R

3m (9.84') pigtail for wall mount boxes5m (16.4') pigtail for rack mount panels

3m (9.84') pigtailfor wall mount boxes5m (16.4') pigtail for rack mount panels

59AD6

BCJG

ST®SCFCDuplex SC1

LC2

Multimode 62.5/125Multimode 50/125Multimode 50/125 laser optimized to 300mm3Multimode 50/125 laser optimized to 550mm3

S

C

S Singlemode

Connector Style

Duplex SC1Ultra PCSTUltra PCSC

LC2

E478

FL2000 6pak plug-in with SC adapters and pigtails

Singlemode Pigtails and Adapters

• ADC recommends specific breakouts for panel and wall mount box products

• Saves installation time

Note: 6paks are putty in color

1 Duplex SC adapters do not double termination count

2 LC 6paks are loaded with 12 fiber pigtails

3 ADC will automatically configure FL2000 panels with laser optimized cable to use aqua colored SC or LC adapters to indicate 10 Gigabit applications

Note: 6paks are putty in color

1 Duplex SC adapters do not double termination count

2 LC 6paks are loaded with 12 fiber pigtails

FL2000 and RMG connector plug-ins are NOT interchangeable

Trang 17

• Completely interchangeable between FL2000

panel and wall box products

• Can be ordered with all standard types

of simplex and duplex single and multimode adapters and connectors

• Feature ADC’s patented removable

angled retainers which provide superior fiber management

• No tools required to install into FL2000

boxes or panels

• Can be ordered with adapters only, or for

quick and easy installation, with preterminated 3 meter (9.84') or 5 meter (16.4') pigtails

6pak blank plug-in

6pak plug-in (shown with singlemode simplex adapters)

6pak plug-in (shown with multimode simplex adapters)

6pak plug-in (shown with singlemode duplex adapters)

6pak plug-in (shown with multimode duplex adapters)

Catalog Number

FL2-6PMMSC FL2-6PMMSC-A FL2-6PMMST FL2-6PMMDSC FL2-6PMMDSC-A FL2-6PMMLC FL2-6PMMLC-A FL2-6PSMSC FL2-6PSMST FL2-6PSMDSC FL2-6PSMLC FL2-6PBLNK

6pak blank plug-in

Trang 18

Rear Guard Box (optional with some racks) Rack shownfor reference

5" (12.7 cm) Recess Mounting Standard

Panel Height

1.75" (4.45cm) 3.5" (8.89cm) 5.25" (13.34cm) 7" (17.78cm) 8.75" (22.23cm) 10.5" (26.67cm)

O r d e r i n g I n f o r m a t i o n

Description Flush mount

Allows 1", 2" or 4" (2.54, 5.08 or 10.16cm) recess mounting

Kit includes: new vertical cable guide and mounting flanges

Standard Mount (as shipped)

Rear Guard Box (optional with some racks) Rack shownfor reference

5" (12.7 cm)Recess Mounting Standard

Trang 19

Panel Height

1.75" (4.45cm) 3.5" (8.89cm) 5.25" (13.34cm) 7" (17.78cm) 8.75" (22.23cm) 10.5" (26.67cm) 14" (35.56cm) 17.5" (43.18cm)

O r d e r i n g I n f o r m a t i o n

Description 19" maximum, black

Allows entire panel to be contained within frame footprint

Kit includes: new vertical cable guide with integrated mounting holes

(12.70cm) (12.32cm)

(12.70cm)5.00"

(7.67cm)

21.22"

(53.99cm) 20.276"

(51.50cm)

21.88"

(55.58cm)

(48.26cm)19.00 18.31"

(46.51cm)

Rack shown for reference

Rear Guard Box (optional with some racks)

Trang 20

Fiber Connectivity Solutions

FPL Series Fiber Panels

Features

• FPL panels combine the unique features of vertical cable guides and angle-left/angle-right adapters, offering diverse cable routing options and a complete cable management solution

• Rear access splicing provides a high-density termination/splice solution maximizing rack space

• 144-position high-density termination/splice panel maintains all existing FPL panel capa-bilities in the space of just five rack units (8.75-inch)

• Panels are equipped with adjustable ing brackets to provide either 19- or 23-inch rack or cabinet mounting (EIA or WECO) as well as 4- or 5-inch recess mounting

mount-• Available preterminated with pigtails to plify ordering and reduce installation time

sim-• ADC’s patented removable angled retainers allow easy access for single fiber maintenance

• Vertical cable guides on either side of the panel provide bend radius protection and management of fibers exiting the panel

• Using LC small-form-factor connectors will double the capacity of each panel

Size in Rack Units

Maximum Density for Termination Only—

Maximum Density for Termination & Splice—

Compatible with ADC Glide? Yes—panel's vertical cable guide can be removed so it does not

interfere with ADC Glide

Best Application Cabinets near servers, switches, routers

Features at a Glance Angled left/right adapters, highest density with maximum cable

management features

FPL Fast Facts

Trang 21

• Panels are only 1 RU (1.75 inches) high

• Available in 12- or 24-position termination only or termination/splice within a single panel

• Using LC small-form-factor connectors double the capacity of each panel

• Angled left and right connectors allow easy cable routing from left and right

• Vertical cable guides on either side of the panel provide bend radius protection and management of fibers

entering or exiting the panel

• Available preterminated with pigtails to simplify ordering and reduce installation time

• For Termination and Splice Panel

• Rear splice area saves space by reducing panel height

• Splice area provides up to a total of five meters of slack storage for pigtails and OSP/IFC buffer tubes

• Designation labels included with each panel

• Mounting brackets included with panel may be flipped to accommodate 19-inch or 23-inch mounting

and 4-inch or 5-inch recess

1 Rack Unit Termination Only or Termination/Splice Panels

Trang 22

Nom Capacity

12-Position24-Position

121D

1 LC connectors and adapters double the capacity of the panel by terminating two fibers at each adapter

2 Nortel Qpak is for use in heat shrink fusion applications using LC adapters

Ports Loaded or Number of Pigtailed Terminations

1.75" (1RU)1.75" (1RU)

Fiber Connectivity Solutions

FPL Series Fiber Panels

Multimode Connectors

9D56

Singlemode Connectors

7E48

Adapters and Pigtails

1 Rack Unit Termination Only or Termination/Splice, Black

Apapter Color

Adapters and Pigtails

A Adapters only

P Stranded pigtails and adapters

R Ribbon pigtails and adapters

B Stranded 50/125 multimode pigtails and adapters

G Stranded 50/125 multimode enhanced to 300m pigtails and adapters

J Stranded 50/125 multimode enhanced to 550m pigtails and adapters

O Standard singlemode or multimode color for adapter

A 10 Gigabit aqua multimode adapter

Trang 23

• Panel may be ordered with adapters only for

a termination-only interconnect solution

• Panel may be ordered with 3.5m pigtails for

use with splice and storage panels

• Rear panel pigtail storage

• Optional lock for both front and rear doors

(available separately)

• Removable front polycarbonate door

• Designation labels included with each panel

• Mounting brackets included with panel can

flip to accommodate 19-inch or 23-inch mounting and 4-inch or 5-inch recess

• Each panel includes two cable clamps

Trang 24

Fiber Connectivity Solutions

FPL Series Fiber Panels Preconfigured Termination Only Panels, Black

Catalog Number FPL- R – 0B

Adapters and Pigtails

Ports Loaded

A Adapters only

P Stranded pigtails and adapters

R Ribbon pigtails and adapters

B Stranded 50/125 multimode pigtails and adapters

G Stranded 50/125 multimode laser optimized to 300m pigtails and adapters

J Stranded 50/125 multimode laser optimized to 550m pigtails and adapters

0 Standard singlemode or multimode color for adapter

A 10 Gigabit aqua multimode adapters

Adapter Color

Trang 25

72-position with IFC

Preconfigured Termination Panels with Multifiber Cable, Black

Features

• Available in 24-, 48-, 72-, 96- and

144-termination densities

• Available with factory-installed multifiber

intrafacility fiber cable (IFC) or OSP cable

• Panels with multifiber cable attached ship as

a single unit with cable clamp installed

• Equipped with customer specified adapters,

connectors, cable type and cable length

• Attached multifiber cable reduces

installation time and simplifies ordering cess with a single part number

pro-• Optional lock for both front and rear doors

(available separately)

• Removable front polycarbonate door

• Designation labels included with each panel

• Mounting brackets included with panel may

be flipped to accommodate 19-inch or 23-inch mounting and 4-inch or 5-inch recess

Ordering information follows on the next page

Trang 26

Fiber Connectivity Solutions

FPL Series Fiber Panels Preconfigurerd Termination Panels with Multifiber Cable, Black

Catalog Number FPL- /

1 Only as second choice (follows the “/”)

2 SC duplex not available in 144-position panel

3 96- and 144-position panels using LC connector styles must use Cable Size option H (2x144) Note: LC adapters double the panel’s capacity Each adapter accommodates two connectors

4 ADC will automatically configure panels with laser optimized cable to use aqua colored SC or

LC adapters to indicate 10 Gigabit applications

E IFC 50/125 laser optimized to 300m

Q IFC 50/125 laser optimized to 550m

R IFC Stranded plenum 62.5/125

B IFC Stranded plenum 50/125

1 IFC Stranded plenum 50/125 laser optimized

3 Indoor/outdoor dry loose tube plenum 50/125

4 Indoor/outdoor dry loose tube plenum 50/125 laser optimized to 300m

5 Indoor/outdoor dry loose tube plenum 50/125 laser optimized to 550m

Singlemode

A SM IFC Stranded corning

F SM IFC Stranded plenum

G SM OSP Stranded sgl armor

H SM Indoor-outdoor

J SM OSP Dielectric stranded

K SM IFC Maxistrip

M SM IFC Ribbon

L SM Ribbon OSP sgl armor

T SM OSP Dielectric ribbon

Trang 27

Preconfigured Termination/Splice Panels, Black

Top cover removed with pigtail routing shown

Number of Splice Trays

• Provides termination and splice of pigtails as

well as associated fiber/pigtail storage

• Rear splice area saves space by reducing

panel height

• ADC recommends completely splicing all

OSP/IFC cables during initial installation to maintain minimal disturbance of the interior

of the panel

• Splice area provides up to a total of seven

meters of slack storage for pigtails and OSP/

IFC buffer tubes

• Optional lock for both front and rear doors

(available separately)

• Removable front polycarbonate door

• Designation labels included with each panel

• Mounting brackets included with panel may

be flipped to accommodate 19-inch or 23-inch mounting and 4-inch or 5-inch recess

• Each panel includes two cable clamps

Ordering information follows on the next page

Trang 28

Fiber Connectivity Solutions

FPL Series Fiber Panels Preconfigured Termination/Splice Panels, Black

Catalog Number FPL- R - B

Adapters/Pigtails

P Stranded pigtails and adapters

R Ribbon pigtails and adapters

B Stranded pigtails and adapters with multimode 50/125 fiber

G Stranded pigtails and adapters with multimode 50/125 laser optimized to 300 meters

J Stranded pigtails and adapters with multimode 50/125 laser optimized to 550 meters

Nominal Capacity Height

1 LC adapters are not available in 96-position panel Use High Density Scheme on following page for

288 fiber count termination/splice LC

2 Nortel Qpak is for use in heat shrink fusion applications using LC adapters

Connector Style (Panel/Stub) Multimode

A 10 Gigabit aqua multimode adapters

Adapter Color

Trang 29

• Provides termination and splicing for up to

144 fibers (288 with LX.5® and LC) within 8.75-inch height (5RU)

• Rear flip-down splicing area uses standard

splice trays and provides slack storage of OSP/IFC buffer tubes

• Angled bulkhead ensures ease of access to

• Removable front polycarbonate door

• Designation labels included with each panel

• Mounting brackets included with panel may

be flipped to accommodate 19-inch or 23-inch mounting and 4-inch or 5-inch recess

• Each panel includes four cable clamps

• Panel available with pigtails only

• Maximum of three panels to be used within

one rack, for a total of 432 terminations

Side view splicing area closed

Top cover removedwith splicing area open

Side view splicing area open

Trang 30

Fiber Connectivity Solutions

FPL Series Fiber Panels

Catalog Number FPL-144 R – B Pigtails

P Stranded pigtails and adapters

R Ribbon pigtails and adapters

B Stranded pigtails and adapters with multimode 50/125 fiber

G Stranded pigtails and adapters with multimode 50/125 laser optimized to 300 meters

J Stranded pigtails and adapters with multimode 50/125 laser optimized to 550 meters

Number of Pigtailed Terminations

A 10 Gigabit aqua multimode adapters

Adapter Color

Trang 31

network’s most vital elements by offering four different designs Termination, termination/splicing,

termination/storage, and slack storage designs are offered with ADC’s modular, all-front-access design

The FMT is ideal for cabinet applications.

Features:

Sliding radius limiters provide ultimate fiber management by addressing one of the most critical elements of fiber cable management: bend radius protection.

By controlling the movement of fibers into the tray, error-proof slack loop management

is maintained, ensuring 30mm bend radius protection This is crucial to protecting fiber, eliminating service failures and decreasing costs.

Modular Design

ADC’s modular design offers the value

of a single interface for performing multiple tasks in your network By employing a one-rack-unit, modular tray, network technicians have familiar access to terminating, splicing, and storing fiber

This cable management approach translates

to time and money saved, for moves, adds and changes.

Sliding Adapter Packs

Sliding adapter packs allow easy access for connecting jumpers and cleaning connectors, ensuring that any fiber can

be installed or removed without disturbing adjacent fibers That can mean the difference between a network reconfiguration time of 20 minutes per fiber and one of over 90 minutes per fiber

All-Front-Access Design

Ngày đăng: 04/12/2015, 00:53

w