MCB MCCB (Circuit Breakers)Compact 80 1250 (Circuit Breakers)ACB masterpact (Circuit Breakers)................................................................................................................................
Trang 10.5 to 125A: Multi 9 circuit breakers
symetrical rail mounting
C60
O - OFF
MERLIN GERIN
NC100H
C100A
415V a
27265
10kA IEC 947.2
O - OFF
1
2
multi 9
MERLIN GERIN
multi 9
C60N
C63
6000
24208
O - OFF
O - OFF
10kA IEC 947.2
1
2
MERLIN GERIN
multi 9
DPN vigi
C40 I∆n 0,300A
20912
BS EN 61009
O - OFF
test mensuel
test monthly
a
4500
6 kA IEC 947.2
DPN Vigi
NC100
electrical characteristics
AC breaking capacity (kA rms)
DC breaking capacity (kA)
trip units (non adjustable)
personnel protection
electrical auxiliaries
installation
Trang 2low breaking capacity range: E
Im
Ir
DE 225
225A/48C
90
105
alarm
Im
Ir
OFF
MERLIN GERIN
compact
NS225 E
Ui 550V Uimp 6kV.
220/240
440
660/690
250
85
30
8
50
cat A
IEC947-2
UTE VDE BS CEI UNE NEM A
(kA)
Ics=50% Icu
225A
push
to
trip
push
to
trip
225E
P93083
Compact NS225E
electrical characteristics
DC
characteristics according to IEC 947.2
660/690V
performances according NEMA
600V
trip units
solid state
protection
generator fed networks long distance networks direct current networks
for motor starters
indications and measurement
voltage presence indicator current transformer module ammeter module
insulation monitoring module
control accessories
direct or extended rotary handles motor mechanism for remote control
installation
plug-in on a base draw-out on chassis
models
switch - disconnector automatic / manual source changeover
Trang 316 to 3200A: Compact
disconnector mouled case circuit breakers
standard range: N
0
push to trip
OFF MERLIN GERIN compact 3-pole 600V 50/60Hz
IEC-VDE-BS
molded case switch
O N
O F
T I P
ST 306ST
test
long
short
ground
fault
trip indicator (push to reset)
tr
84 81
1.5
2
6
10
Im
.63
.7
.85 9
.95
1
xIn
Ir
STR 22 SE
90
105%Ir
alarm
Im
Ir
I n = 2 5 0 A
OFF
MERLIN GERIN
compact
NS250 N
Ui 750V Uimp 8kV.
220/240
440
660/690
250
85
30
8
50
cat A
IEC947-2
UTE VDE BS CEI UNE NEMA
(kA)
Ics=100% Icu
160/250A
push
to
trip
push
to
trip
250N
P93083
PUSH TO TRIP
MERLIN GERIN
compact
C 1001 H
Ui 750V Uimp 8kV.
Ue
220/240
440
500/525
100
70
IEC 947-2
UTE VDE BS CEI
UNE NEMA
Icu
cat B
Ics = 100% Icu
Icw 8kA / 0,25s.
OFF
60 70 80 90 105 %Ir STR 55UE
TFR
Io
xIn
test fault
connected
disconnected
16 to 100A 16 to 160A 16 to 250A 160 to 400A 250 to 630A 320 to 800A 400 to 1000A 500 to 1250A 625 to 1250A 800 to 1600A 1000 to 2000A 1250 to 2500A 1600 to 3200A
electrical characteristics
characteristics according to IEC 947.2
performances according NEMA
trip units
protection
indications and measurement
control accessories
installation
models
Compact NS250N
Compact C801N with universal chassis
Compact CM1250N
Trang 4high breaking capacity range: H
1.5
2
6
10
Im
.63
.7
.85 9
.95
1
xIn
Ir
STR 22 SE
90
105 %Ir
alarm
Im
Ir
I n = 2 5 0 A
OFF
MERLIN GERIN
compact
NS250 N
Ui 750V Uimp 8kV.
220/240
440
660/690
250
85
30
8
50
cat A
IEC947-2
UTE VDE BS CEI UNE NEMA
(kA)
Ics=100% Icu
160/250A
push to
trip
push to
trip
250N
P93083
1.5 to 80A 16 to 100A 16 to 160A 16 to 250A 160 to 400A 250 to 630A 320 to 800A 400 to 1000A 500 to 1250A 625 to 1250A 800 to 1600A 1000 to 2000A 1250 to 2500A 1600 to 3200A
electrical characteristics
characteristics according to IEC 947.2
performances according NEMA
trip units
protection
indications and measurement
control accessories
installation
models
visible break circuit breaker Visucompact
switch - disconnector
Compact NS250H
60 70 80 90 105 %Ir
STR 55UE
TFR
Io
xIn
test
I
0
MERLIN GERIN
compact
C 1001 H
Ui 750V Uimp 8kV.
Ue
220/240
440
500/525
100
70
35
IEC 947-2
UTE VDE BS CEI
UNE NEMA
Icu
(kA)
cat B
Ics = 100% Icu
Icw 8kA / 0,25s.
Compact C801H with motor mechanism
0
push to trip
OFF compact RIN CM2500HE 3-pole 600V 50/60Hz 2500A max.
IEC-VDE-BS
molded case switch
O N
O F
T I P
ST 306ST
test
long
short
time
ground
fault
trip indicator (push to reset)
tr
84 81
Compact CM1250H
Trang 516 to 1000A: Compact
disconnector mouled case circuit breakers
current limiting range: L
1.5
2
6
10
Im
.63
.7
.85 9
.95
1
xIn
Ir
STR 22 SE
90
105 %Ir
alarm
Im Ir
I n = 2 5 0 A
OFF
MERLIN GERIN
compact
NS250 N
Ui 750V Uimp 8kV.
220/240
440
660/690
250
85
30
8
50
cat A
IEC947-2
UTE VDE BS CEI UNE NEMA
(kA)
Ics=100% Icu
160/250A
push
to
trip
push
to
trip
250N
P93083
16 to 100A 16 to 160A 16 to 250A 160 to 400A 250 to 630A 320 to 800A 400 to 1000A
electrical characteristics
characteristics according to IEC 947.2
performances according NEMA
trip units
protection
indications and measurement
control accessories
installation
models
switch - disconnector
Compact NS250L
STR 53 UE
test
MERLIN GERIN
compact
NS400 L
Ui 750V Uimp 8kV.
Ue
220/240
440
500/525
100
70
35
IEC 947-2
UTE VDE BS CEI
UNE NEMA
Icu
(kA)
cat B
Ics = 100% Icu
In = 400A
push
to
trip
push
to
trip 400
tr
tm
Ir I
%Ir >Ir >Im >Ih
Io
x In
.5
Ir
x Io
.8
.85
.9 93
1
.98
Im
x Ir
1.5
2
10
8
Il
x In
1.5
2
11
Ih
x In
.8
tr
(s) @ 6 Ir
1
16
th
I2t
1
on
tm
I2t
0
on
A
Compact NS400L
PUSH TO TRIP
MERLIN GERIN
compact
C 1001 H
Ui 750V Uimp 8kV.
Ue
220/240
440
500/525
100
70
35
IEC 947-2
UTE VDE BS CEI
UNE NEMA
Icu
(kA)
cat B
Ics = 100% Icu
Icw 8kA / 0,25s.
OFF
60 70 80 90 105 %Ir
STR 55UE
TFR
Io
xIn
test t
Compact C801L
Trang 6M08 M20 M32 M50
M12 M16
electrical characteristics
performances according NEMA
trip units
protection
rated breaking capacity for DC (Icu=Ics=Icw) HI type only 50kA 125V DC maximum, consult us for other specific version
indications, measurement and monitoring
control accessories
installation
M63 : 1045 x 484 x 367
push to reset
I1
90%
20%
STR 58 UE
0.63
Io Ir
0.5
xIn
90
105
.88
xIo
Im tm
3
xIo
.3
on I2 t off
.2
Ir fault
tr
Im fault tm
fault
Ih
test
+ S –
T
F
Ih
400
A
.2
on I
t off
.3
off
xIn
IIG LIG
off
reset V
tr120
15
at 1,5Ir
4
Ic1
.86
.85
test
O
push OFF
MERLIN GERIN M32 H1 masterpact
IEC 947-2 00000
connected
test disconnected
O OFF discharged
I
push ON Ui
Ics 1000V 380/440V 100kA 75kA 1s 50/60Hz 480/690V 85kA
Masterpact M08
Trang 7MERLIN GERIN
interpact
INS80
Ui 500V
Uimp 6kV
Ith 80A@ 60 ° C
Ue(V) Ie(A)
AC23A
IEC 947.3
UTE VDE BS CEI UNE
500 80
AC22A
DC23A
80
440
OFF
O
ON I
Interpact INS80
electrical characteristics as per IEC 947-3
interpact
MERLIN GERIN
IN630
IEC-VDE-BS-UTE
Ui 660 V
AC 22 630A
380/415V
500 V
I
0 OFF
Interpact IN630
40 to 2500A: Interpact
switch-disconnector
electrical characteristics as defined by IEC 947-3 and EN 60947-3
DC (4P in series) DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A
installation
Trang 8B, C and D curves Application
Control and protection of circuits against overloads and short-circuits
distribution systems
Technical data
to EN 60898
to IEC 947-2 Icu
between 3 and 5 In,
between 5 and 10 In,
between 10 and 14 In;
cables up to:
v25 mm2 for rating ≤ 25 A,
v35 mm2 for rating ≤ 63 A;
96 (set of 2 combs 48 mod.) 14891
96 (set of 2 combs 48 mod.) 14893
00000
10000
3
1 2 3 4 6 10 13 16 20 25 32 40 50 63
1 2 3 4 6 10 13 16 20 25 32 40 50 63
1 2 3 4 6 10 13 16 20 25 32 40 50 63
1
2 3
4
????
1
2
????
00000
00000
1
2 3
4 5
6
????
Trang 9type width rat cat No.
1 2 3 4 6 10 13 16 20 25 32 40 50 63
1 2 3 4 6 10 13 16 20 25 32 40 50 63
1 2 3 4 6 10 13 16 20 25 32 40 50 63
B, C and D curves Application
Control and protection of circuits against overloads and short-circuits
distribution systems
Technical data
to EN 60898
to IEC 947-2 Icu
between 3 and 5 In,
between 5 and 10 In,
between 10 and 14 In;
cables up to:
v25 mm2 for rating ≤ 25 A,
v35 mm2 for rating ≤ 63 A;
96 (set of 2 combs 48 mod.) 14891
96 (set of 2 combs 48 mod.) 14893
00000
1
2
????
1
2 3
4 5
6
????
1
2 3
4
????
00000
00000
circuit protection
circuit breakers up to 63 A
C60N circuit breaker - EN 60898
6000
3