Suitable for TEFC or TEFC-XT foot and footless design only not XP or O 28 5.5 inch frame - Aluminum end shield standard enclosure 29 6.3 inch frame - Aluminum end shield standard enclosu
Trang 1Allen-Bradley offers the broadest selection of drive and motor packages designed for optimum variable-speed
performance, service life and value These Control-Matched drive and motor packages are a result of the
practi-cal application of advanced electripracti-cal/electronic technology – backed by decades of application experience in
virtually every industry
For additional information refer to our web site: www.controlmatched.com
For Optimum Variable-Speed Value
www.rockwellautomation.com
Corporate Headquarters
Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201
Headquarters for Dodge and Reliance Electric Products
Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433
Europe/Middle East/Africa: Rockwell Automation, Herman-Heinrich-Gossen-Strasse 3, 50858 Köln, Germany, Tel: 49 (0) 2234 37941252, Fax: 49 (0) 2234 3794164
Asia Pacifi c: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887.4788, Fax: (852) 2508.1846
Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions
Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444
Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640
Allen-Bradley Control Matched
Motor Catalog
Trang 23 Not suitable for use on motors with model number with a, b, or c suffi xes
4 Wye start, Delta run
5 Belted duty only, roller bearing
6 F-2 mounting
7 Companion voltages not available
8 TENV motors are capable of 20:1 speed range operation on drives with no back diode
9 Motors are not NAFTA qualifi ed
10 These motors meet the hardware requirements of IEEE 45/ABS and are not provided with Marine Plan Documentation
11 Price includes XT features and explosion proof prices include drain on drive end
12 Does not meet NEMA BA for C-Face Footed Motors
13 Furnished without conduit box Order kit P/N K56G3230
14 Type CH
15 Motors rated 208 - 230/460 are operable to minimum 200 volts
16 Standard TENV motor with standard lead length
17 Class B insulation, 1.0 service factor
18 Class B insulation, 1.25 service factor
19 Class B insulation, 1.35 service factor
20 Class F insulation
21 Double bolt
22 Base used for NEMA & above NEMA frames, 445T
23 Two piece slide rails
24 Includes terminal board
25 Production only after stock depleted To be superseded by V*S Master Motor
26 See OMS
27 Kits include textile fan cover with drip cover mounted Suitable for TEFC or TEFC-XT foot and footless design only (not XP or O
28 5.5 inch frame - Aluminum end shield standard enclosure
29 6.3 inch frame - Aluminum end shield standard enclosure
30 Motors usable on 208 volts @ specifi ed amps
31 Suitable for 230/460, 60Hz and 190-220/380-440 volts, 50Hz
32 Stearns brake
33 Reliance AC brake
34 Dodge D series brake
35 Design A, also meets Design E inrush limits
36 1.0 Service factor when operated at 50Hz
37 Derate horsepower 20% when operated at 50hz
38 Consists of sleeve and key to convert 1/2 shaft to 5/8 shaft
39 Coupled Duty only, TS shaft
40 Includes tachometer, stab shaft and mounting hardware
41 Will mount any tachometer having standard NEMA 56 C-face and shaft extension
42 DODGE Short Series Brake
43 Cannot be mounted vertically
44 Scrambler drive - DC integrated control and motor product
45 Maximum value
46 No key - 1.25 long fl at
47 BA dimension does not meet NEMA standards
48 Includes phase insulation Suitable for inverter duty
49 Includes vertical lifting provision
54 For single phase ratings: O = 7.31: Z = 12.80
55 Refer to previous dimension pages
56 48 through 140T frame ratings are typical full load effi ciency, not nominal effi ciency
57 56 through 140T frame performance data is valid for TENV or TEFC 180T and larger frame performance data is valid for TEFC ONLY
59 FLA includes harmonic content from PWM power supply
61 TENV motors have a constant torque speed range from 0 to base speed
62 TENV motors have provisions for tachometer mounting as standard
65 Will fi t standard effi cient F model numbers ONLY
71 Nominal effi ciency is base at the 1800 RPM (High RPM) and low speed effi ciency is available just not published
72 Orders shipped from a Rockwell Automation facility in 5 working days Motor is returnable for a restocking charge of $100 plus
73 Can only be used on motors 1800 RPM and slower with ball bearings
75 Availability limited to current stock
77 Buying motors not manufactured by Rockwell Automation may cause loss of sleep
79 Motor mounted blower is located on drive end
80 Motor has thermostat and provisions for adding fl ange mtd tach
81 Motor has thermostat and provisions for adding adapter mtd tach
82 Motor is force ventilated and supplied with blower, and fi lter
83 May be operated on 50 Hz rectifi ed power supply with full nameplate rating AC supply voltage must be same as 60 Hz supply; i.e
84 May be operated on 50 Hz rectifi ed power supply with full nameplate rating only when motor is force ventilated with motor mount
85 Cannot be operated at full nameplate rating on 50 Hz rectifi ed power supply
86 Winder Duty - 100% load for 1 minute at 3000 RPM, straight shunt design Includes blower without fi lter Tachometer is rated at
87 Motor has thermostat and provision for adding integral AC or DC tachometer or adapter mounted tachometer
88 Motor is force ventilated and supplied with blower
89 Motor is force ventilated and supplied with single-phase blower motor rated 1/3 HP, 3450/2850 RPM, 115/230 volts, 60/50 Hz
90 Includes thermostat
91 Includes Dynapar H20 1024 PPR encoder with mating 10 pin MS connector Requires 2-7 business days
92 Blower is piggyback mounted on L440 frames
93 180TC NEMA fl ange size, see appropriate dimension sheet
94 210TC NEMA fl ange size, see appropriate dimension sheet
95 250TC NEMA fl ange size, see appropriate dimension sheet
96 See appropriate dimension sheet for fl ange size
99 Highlighted for Marketing Review
100 Ball bearing only
101 Not available for Easy Clean product line
102 Not available for XT enclosures
103 Not available for Non-NAFTA motors
104 Not available for 841 XL motors
105 Not available on SABRE and CALIBRE product lines
106 Finned aluminum frame construction
107 Not available on belted duty motors and/or motors with roller bearings
121 Motor is rated for F rise 1000:1 Constant Torque Range, and F Rise 4:1 Constant Torque Range
122 Motor rated for only F rise 4:1 Constant Torque Range
V Version Note- Controlled by Passport See V
Component Class - Inverter Duty Architecture Class - V
ODP - Open Drip-Proof TEAO - T
Base Speed As noted - fi
Trang 4Table of Contents
GENERAL INFORMATION
Efficiency Abbreviations
Agency Approvals/Certifications/Approvals
Cancellation Charges
Freight Policy
Warranty Policy
Motor Selection and Application
Conduit Box Location Chart
Evaluation of Motor Efficiency
Rush/Breakdown Order Procedures
Sales Order Change Charges
Rockwell Automation Motor Service Centers
Documentation
Return Policies
RAISE Software File Information
COMPONENT CLASS For use on inverter for variable torque and constant torque (less than 10:1) applications, no encoder capability, 3 NC thermostats included INVERTER DUTY GENERAL PURPOSE SERIES CM101 – Enclosed Energy Efficient Rolled Steel
Most Economical Inverter Capable, Totally Enclosed Motor 10:1 VT and 2:1 CT Capability CM102 – Enclosed Energy Efficient Cast Iron
Most Economical Inverter Capable, Cast Iron Totally Enclosed Motor 10:1 VT and 2:1 CT Capability CM103 – Totally Enclosed Energy Efficient, Premium Efficient, and NEMA Premium
Designed for General Purpose Applications 10:1 VT and varying CT Capability CM106 – Open Energy Efficient Rolled Steel
Most Economical Inverter Capable, Open Motor Available, 10:1 VT and 2:1 CT Capability CM107 – Open Energy Efficient, Premium Efficient, NEMA Premium
General Purpose Open motors
10:1 VT and 2:1 CT Capability
1 1 3 3 4 5 9 10 12 12 12 13 13 13
14
18
22
32
35
Trang 5HARSH DUTY HARSH ENVIRONMENT SERIES
CM111 – Severe Duty
Designed with features for long life in severe environments such as chemical plants, petroleum refineries, and paper mills 10:1 VT and varying CT Capability
CM112 – IEEE 841 XL
Exceeds IEEE841 mechanical requirements Built extra tough for durability in harsh environments 10:1 VT and varying CT Capability
CM113 – Aggregate Duty
Designed with high starting torque and break down torque for heavily loaded conveyor and crusher applications 10:1 VT and varying CT Capability
CM115 – Wash Down Duty
Designed for service in wash down applications subject to sanitary codes, IP55 10:1 VT and varying CT Capability
For use on inverter only for high performance applications, encoder capable, 3 NC thermostats included
INDUSTRIAL ENVIRONMENT SERIES
CM201 – Vector Duty Enclosed Small AC Motors
1000:1 CT Capable, TENV and TEFC Enclosures
CM202 – Vector Duty Totally Enclosed Cast Iron NEMA AC Motors
1000:1 Capable, TEFC and TENV Enclosures
CM202 KITS CM203 – Vector Duty Laminated AC Motors
1000:1 Capable; DPFV, TEBC, TENV, and TEFC Enclosures
CM203 KITS CM205 – DC Motors
Designed with laminated square frame for more performance in smaller frames DPG-FV and TEFC enclosures
CM205 KITS CM206 – Small DC Motors
Designed for reliability and long life in variable speed applications TEFC and TENV Enclosures
120 123
Trang 6SINE WAVE CLASS
For use on sine wave power for fixed speed applications such as conveyors, blowers, pumps or fans
GENERAL PURPOSE SERIES
CM301 – Enclosed Energy Efficient Rolled Steel
Most Economical Totally Enclosed Motor
CM302 – Enclosed Energy Efficient Cast Iron
Most Economical Cast Iron Totally Enclosed Motor
CM303 – Totally Enclosed Energy Efficient, Premium Efficient, and NEMA Premium
Designed for General Purpose Applications
CM306 – Open Energy Efficient Rolled Steel
Most Economical Open Motor Available
CM307 – Open Energy Efficient, Premium Efficient, NEMA Premium
General Purpose Open motors
HARSH ENVIRONMENT SERIES
CM311 – Severe Duty
Designed with features for long life in severe environments
such as chemical plants, petroleum refineries, and paper mills
CM312 – IEEE 841 XL
Exceeds IEEE841 mechanical requirements
Built extra tough for durability in harsh environments
CM313 – Aggregate Duty
Designed with high starting torque and break down torque
for heavily loaded conveyor and crusher applications
CM315 – Wash Down Duty
Designed for service in wash down applications subject to sanitary codes, IP55
153
163
168
171 176
Trang 8For additional product information refer to Proposal Builder.
General Information
Efficiency Abbreviations
Agency Approvals/Certifications/Definitions
NEMA PREMIUM/CEE
The Consortium for Energy Efficiency
(CEE) a non-profit, public-benefit
corporation helps find ways that consumers, businesses
and manufacturers can save energy CEE members
include electric and gas utilities, public interest groups,
research and development organizations, state energy
offices and regional programs Both the U.S
Environmental Protection Agency (EPA) and the
Department of Energy (DOE) are major partners.
CEE coordinates market research, facilitates the exchange of information and provides interface with national manufacturers, such as Rockwell Automation by establishing specifications for energy-efficient products and services The tables below can be used to determine which Allen-Bradley motors meet or exceed the NEMA Premium/CEE specifications.
CSA
Canadian Standards Association is the clearinghouse and coordinating body for standards activity on a national level Products covered by CSA are either “Certified” or
“Labeled” depending on the standards involved
CSA NRTL/C MARK
Hazardous Location Report: LR 6771,
LR 19467, LR 46877, LR 53258, LR60344 Ordinary Location Report: LR 7861, LR 40567, LR52580, LR 62409
This monogram indicates the product complies with both USA (UL) and CSA standards This marking should be accepted by all localities in the USA and Canada.
Division II atmosphere is normally not explosive, but
under unusual conditions can become explosive Rockwell Automation has a defined Division II product line and received CSA certification on the following:
180T - 449T AC 1080T - 9600 AC 169AT - 1610AT DC 7MG - 80MG The standard Division II enclosure is TEFC with Severe Duty features However, other enclosures are available
Trang 9For additional product information refer to Proposal Builder.
C390
C390 is the Canadian efficiency equivalent of
EPAct File number: EEV79350
Requires at least an Energy Efficient electrical design
motor to meet C390.
CENELEC
The European Committee for Electrotechnical
Standardization defines compliance standards for CE
mark required on motors shipping to Europe.
This mark signifies the motor complies with all applicable
European Directives.
REL-4496-001 (Kings Mountain DC Motors)
REL-0296-001 (AC Induction Motors)
REL-4596-001 (Gainesville DC Motors)
For hazardous locations in Europe or for ATEX
certification or “EX” mark or flame proof enclosure, contact
your local Rockwell Automation sales representative.
Compliance Certification (CC049A and CC019A) Numbers
This symbol and certification numbers indicate that certain
Allen-Bradley catalog numbers meet or exceed the energy
efficiency requirements contained in title 10 of the Code of
Federal Regulations Part 431 (10 CFR Part 431), Energy
Conservation Program for Certain Commercial and
Indus-trial Equipment and Part C of the Energy Policy and
Conservation Act, 42 U.S.C 6311 et seq Allen-Bradley
motors covered by the certification (Energy Efficient "EE",
Premium Efficient "PE", and NEMA Premium “NP”) are
footnoted in the catalog with CC049A and CC019A
com-pliance certification numbers.
Basic guidelines:
• 1-200 hp (.75-150 kw)
• Open, Enclosed, or Explosion Proof
• 2, 4, or 6 pole (single speed)
• Continuous duty
• Squirrel cage rotor (NEMA) or cage rotor (IEC)
• Foot mounted, including foot mounted with flanges or
detachable feet
• NEMA T frame or IEC metric equivalent
• NEMA Design A or B, IEC Design N
• 60 hz
• 230 or 460 volt or both
These are general guidelines and not intended to be used
as the final determination of compliance For specific
questions pertaining to this compliance, please contact
your Rockwell Automation sales representative.
IEEE
Institute of Electrical and Electronic Engineers is a Technical Organization that publishes various recommended practices, which have been adopted as Industry Standards Recommended practices do not require approval action or special testing.
Rockwell Automation may furnish specialized equipment
in accordance with this specification.
representative for additional information on the ISO 9000 standards and Rockwell Automation compliance.
NEC
National Electrical Code is an ASA Standard “NFPA-70” sponsored by the National Fire Protection Association for the purpose of safeguarding persons and buildings from electrical hazard arising from the use of electricity for light, heat, power, and other purposes.
NEMA
National Electrical Manufacturers Association Standards are voluntary standards that represent general practices in the industry They define a product, process or procedure with reference to nomenclature, composition, construction, dimensions, tolerances, operating characteristics,
performance, quality, rating and testing Specifically, they cover such matters as frame sizes, torque classifications, and basis of rating.
NRCAN Natural Resources Canada
For Canadian customers, NRCAN regulations require registration and energy efficiency reporting of certain 1-200HP and 0.75-150KW rated motors The following website address will lead to the NRCAN website and Rockwell Automation forms for both NEMA and IEC motors as well as UMI codes The address is www.reliance.com/mtr/orgreg.htm Just click on NRCAN from the column on the left side of this website page.
Trang 10For additional product information refer to Proposal Builder.
UL & UR
Underwriters’ Laboratories,
Inc is chartered as a
non-profit organization to establish, maintain, and operate
laboratories for the examination and testing of devices,
systems, and materials The UL presently publishes more
than 250 Standards for Safety for materials, devices,
constructions and methods UL also undertakes
numerous research projects in areas of
safety.
/Description
Description
Division I atmosphere is considered potentially explosive
under normal conditions.
For hazardous locations in Europe or for ATEX
certification or “EX” mark or flame proof enclosure, contact
your local Rockwell Automation sales representative.
Temperature Codes (“T” Codes)
NEC requires explosion-proof motors to indicate the maximum operating surface temperature A “T” Code is used as the temperature identification value and it is taken from the National Electric Code The “T” Code is based on the minimum ignition temperature of the substances to be found in the hazardous location (Ignition temperature is when substance will start to burn or explode) The code, when marked on a motor nameplate, represents the highest temperature that could be obtained on the motor surface under any normal or abnormal operating
conditions including locked rotor, single phasing or overloading, and is chosen to be below the ignition temperature of the substance in the hazardous area The
“T” Code designations apply to motors and other types of electrical equipment subject to hazardous location classification For further information, consult the Motor Technical Reference (MTR) on the Web at http://
www.reliance.com/mtr.
Cancellation Charges
Non-Stock Motors
A minimum charge of $100 will apply to any order
cancellation Cancellation charges for orders received and
entered on the manufacturing facility will be determined
based on cost incurred.
Completion of order includes consideration of the
following:
• order edit and acknowledgment
• capacity allocation
• engineering and specification
• material commitment (raw, finished, and purchased)
Completion progress to be determined by producing plant
180AT - 500AT DC Hazardous E10822
Thermal Protectors Recognized E22031
Motor Components Recognized E54825
Insulation Materials Recognized E39972
Conduit Boxes Hazardous E30225, E40711
Hermetic Recognized SA5484
Trang 11For additional product information refer to Proposal Builder.
Limited Warranty Policy
All Allen-Bradley Brand Products are warranted against
defects in workmanship and materials Most are covered
for 12 months from date of installation or 18 months from
date of manufacture, whichever occurs first Some
products carry a longer warranty period.
If within the warranty period, Rockwell Automation
receives from the Buyer written notice of any alleged
defects in any such Product and if the apparatus is not
found to be in conformity with this warranty (the Buyer
having provided Rockwell Automation a reasonable
oppor-tunity to perform any appropriate tests thereon) Rockwell
Automation will, at its option, either repair the same or
supply a replacement therefor.
Rockwell Automation under either option shall have the
right to require the Buyer to deliver the apparatus for this
purpose to its designated service center or manufacturing
facility and the Buyer shall pay all charges for in-bound
and out-bound transportation and for services of any kind,
diagnostic or otherwise, excepting only direct and actual
costs of apparatus repair or replacement as provided
above Rockwell Automation is not responsible for
inciden-tal or consequential charges to include, but not limited to,
removal, installation, downtime, etc.
This limited warranty does not apply to normal wear items
or any product which has been subject to misuse,
misap-plication, neglect (including without limitation, inadequate
maintenance or failure on the part of the Buyer to ensure
proper storage), accident or improper installation, cation, adjustment, or repair This constitutes Rockwell Automation's only warranty in connection with this sale
modifi-THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESSED, IMPLIED OR STATUTORY, INCLUDING IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE, OR PERFORMANCE OR APPLICATION WARRANTIES, AND EXTEND ONLY TO CUSTOMERS PURCHASING FROM SELLER OR ITS APPOINTED DISTRIBUTOR.
No employee, agent, dealer or other person is authorized
to give any warranties on behalf of Rockwell Automation nor to assume for Rockwell Automation any other liability
in connection with any of its Products, unless otherwise agreed in writing by Rockwell Automation's Headquarters.
Warranty Administration and Processing
Warranty claims can be processed using the Motor Warranty Administration form available on the Control-
Matched web-site at www.controlmatched.com
Select the radial button for “Warranty Request Form” All required fields MUST be filled in for a warranty request
Standard efficient motors (SE) 12 months 24 months
Energy Efficient motors (EE) 12 months 24 months
Premium Efficient motors (PE) 24 months 36 months
NEMA Premium Efficient motors (NP) 24 months 36 months
DC Motors – CM205, CM206 12 months 24 months
Vector Duty AC motors – CM201, CM202, CM203 24 months 36 months
Trang 12For additional product information refer to Proposal Builder.
Motor Selection and Application
Safety
The use of electric motors, like that of all other utilization
of concentrated power, is potentially hazardous The
degree of hazard can be greatly reduced by proper
design, selection, installation and use, but hazards cannot
be completely eliminated.
Some of the factors that must be considered for the safe
application of motors are as follows:
1 Enclosure
2 Service conditions
3 Proper matching of the motor to the load
4 Proper sizing and connection to an inverter by qualified
technicians
Information on these factors is presented in this section.
Enclosure
The selection of the proper enclosure is vital to the
successful safe operation of AC motors Machine
performance and life can be materially reduced by using
an enclosure inappropriate for the application The
customer must recognize the specific environmental
conditions and specify the correct enclosure Rockwell
Automation can provide application assistance, but must
depend on the customer to provide accurate information
on the operating conditions.
Rockwell Automation offers motors in the following
enclosures:
• Open Drip-Proof
• Totally Enclosed (Non-Ventilated, Fan Cooled, Air Over)
• Explosion Proof
• Dust Ignition Proof
Open Drip-Proof Motor (ODP)
An ODP motor is an open machine having all openings
limited in size to prevent accidental contact with
hazardous parts Internal parts are protected from drip,
splash and falling objects on all horizontal and vertical
mounted motors ODP motors are suitable for general
industrial use in indoor locations with relatively clean
atmospheres.
Totally Enclosed Motor
A totally enclosed motor is one so enclosed as to prevent the free exchange of air between the inside and the outside of the case but not sufficiently enclosed to be termed air-tight Totally enclosed motors are suitable for use in dusty dirty locations and in humid environments.
Totally Enclosed Non-Ventilated - Not equipped for
cooling by means external to the enclosing parts
Generally limited to low horsepower ratings or short-time rated motors.
Totally Enclosed Fan-Cooled - Exterior surface cooled
by external fan on motor shaft Motor cooling is dependent
on motor speed.
Totally Enclosed Air-Over - Exterior surface cooled by a
ventilating means external to the motor Customer must provide sufficient air flow to cool motor.
Additional protection for motors used in extremely dirty or humid conditions is offered by Rockwell Automation Severe Duty features.
(IP) Classification of Enclosures
The classification system consists of the letters IP (Ingress protection) followed by two numbers The first number indicates the degree of protection against entry of solid material into the enclosure The second number indicates the degree of protection against entry of liquids
Table 1: Degree of protection against solid material and
personal injury indicated by the 1st number
Numberal Definition
0
No special protection of persons against accidental or inadvertent contact with live or moving parts or against the ingress of solid material
1
Protection against accidental inadvertent contact with live or moving parts by large surface of a body such as a hand or similar object exceeding 50 mm
2
Protection against accidental or inadvertent contact with live or moving parts by a finger or similar object exceeding 12 mm
3 Entry prevented of tools, wires or other solid objects of a diameter or thickness greater than 2.5 mm
4 Entry prevented of wires, strips or solid objects of a diameter or thickness greater than 1.0 mm
5
Complete protection against contact with live or moving parts inside the enclosure The entry of dust is not totally prevented, but dust cannot enter in sufficient quantity to interfere with the satisfactory operation of the motor
6
No ingress of dust Per IEC 34-5 this degree of protection
is not applicable to rotating equipment such as motors and generators but applicable to electrical enclosures
Trang 13For additional product information refer to Proposal Builder.
(IP) Classification of Enclosures (con’t)
Abbreviations for Enclosure Types
DPG - Drip-Proof Guarded
DPG-FV - Drip-Proof Guarded - Force Vent
DPSV - Drip-Proof, Separately Vented
FC - Fan Cooled
FCXP - Fan Cooled, Explosion Proof
IP-22 - Open Drip-Proof (IEC Standard)
IP-23 - Splash Proof (IEC Standard)
IP-44 - Totally Enclosed (IEC Standard)
IP-54 - Splash Proof (IEC Standard)
IP-55 - Washdown (IEC Standard)
NV - Non-Ventilated
NVXP - Non-Ventilated, Explosion Proof
ODP - Open Drip-Proof
SPG - Splash Proof Guarded
TEAO - Totally Enclosed, Air Over
TEBC - Totally Enclosed, Blower Cooled
TEDC-AA - Totally Enclosed, Dual Cooled, Air to Air
TEDC-AW - Totally Enclosed, Dual Cooled, Air to Water
TEFC - Totally Enclosed, Fan Cooled
TENV - Totally Enclosed, Non-Ventilated
WPI - Weather Protected, Type I
WPII - Weather Protected, Type II
Explosion Proof and Dust Ignition Proof Motors For Hazardous Locations
Explosion Proof - An Explosion Proof motor is a totally
enclosed machine designed to operate safely in an environment in which flammable gas or vapor is present This is accomplished by limiting the external surface temperature of the motor below the ignition temperature of the hazardous gas or vapor surrounding the motor Hence
it is very important that the end user order a motor with the proper temperature code Also the enclosure is designed
to contain an explosion on the inside of the motor which may be caused by arcing, sparking, or abnormal heat A flame caused by such an explosion will not propagate the motor fits and ignite the gas or vapor surrounding the motor An explosion proof motor is suitable for operation in Class I hazardous environment.
Dust Ignition Proof - A Dust Ignition Proof motor is a
totally enclosed machine designed to operate safely in a flammable dust environment The motor enclosure pre- vents the admittance of dust inside the motor Also the motor is designed to operate cool enough so as not to ignite any dust which might accumulate on the external surface of the motor Should the motor become blanketed with dust and reduce its normal cooling, winding
thermostats will take the motor off line before the motor’s external surface temperature reaches the ignition temper- ature of the hazardous dust A dust-ignition-proof motor is suitable for operation in a Class II hazardous location The specific dust or gas present in the hazardous location
is identified by the group listing for each Class Certain Allen-Bradley AC motors are listed for use in Class I Groups C and D and Class II Groups E, F and G locations depending on the horsepower rating, frame size and enclosure as indicated on the price pages The user customer is responsible for insuring that the proper UL listed motor is used in a specific hazardous location.
For hazardous locations in Europe or for ATEX certification or “EX” mark or flame proof enclosure, contact your local Rockwell Automation sales representative.
Table 2: Degree of protection of motors against the
harmful ingress of water by the 2nd number
Numberal Definition
0 No special protection
1 Vertically falling drops
2 Drops falling at any angle up to 15° off of vertical
3 Spray at any angle up to 60° off of vertical
4 Splashed from any direction
5 Projected by nozzle from any direction has no harmful
effect
6 Water from heavy seas or projected from powerful water
jets has no harmful effect
7
Entry of water in a harmful quantity is prevented when the unit is immersed in water under stated conditions of pressure and time
8 Immersed under water specified pressure for an
indefinite time
ATTENTION: Misapplication of a motor in a hazardous environment can cause a fire or an explosion and result
in serious injury Only the end user and/
or insurance underwriter are qualified
to identify the appropriate class(es), group(s), division and temperature code Rockwell Automation personnel should not render any assistance in identifying the type of environment.
Trang 14For additional product information refer to Proposal Builder.
Standard motors listed in this catalog are designed to
operate under the following service conditions Service
conditions exceeding these conditions may require special
motor selection or re-rating of standard motors.
Altitude - Sea Level to 3300 feet.
Ambient Temperature - -25° C to 40° C.
Mounting - The standard motors listed in this catalog are
either foot mounted or have a C-face as indicated on the
price pages The motor must be mounted on a rigid
mounting surface for satisfactory operation.
Installation - Motor must be in areas or in supplementary
enclosures which do not seriously interfere with the
ventilation of the motor.
Power Supply
Phase - Motors are designed for either single-phase or
three-phase operation as indicated on the price pages
Single-phase motors may be operated on one-phase of a
three-phase power supply with the rated voltage
Operation of a three-phase motor on a single-phase
supply will result in motor damage.
Voltage
Single Phase Motors - standard voltages are 115/230.
Three Phase Motors - standard voltage are 190/380,
200, 200/400, 230/460, 208-230/460, 460 and 575 as
indicated on the price pages Specific Definite Purpose
motors may have other voltages indicated Motors rated at
230 or 230/460 volts will operate on a 208 volt supply
except that starting and peak running torques at 208 volts
will be 20-25% less than at the 230 volt rating Motors
nameplated 208-230/460 will operate satisfactorily at 208
volts.
Voltage Variation - In accordance with NEMA standards,
Allen-Bradley motors will operate with +10% variation in
rated voltage with rated frequency Performance within this
voltage variation will not necessarily be in accordance with
performance at rated voltage.
Dual Voltage Motors are easily reconnectable by
referring to the information on the motor nameplate.
60 Hz as specified on the price pages Many motors designed for operation on 60 Hz power may be operated
on 50 Hz power of a lower voltage rating with resulting decrease in speed and horsepower Refer to Rockwell Automation for details In accordance with NEMA standards Allen-Bradley motors will operate with +5%
variation in rated frequency with rated voltage
Performance with this frequency variation will not necessarily be in accordance with performance at rated frequency.
Insulation Class & Temperature Rise
Motor Insulation systems are classified by the maximum total temperature at which the system can be operated without adversely affecting design life This maximum total temperature has three components.
Four classes of insulation systems are used in motors In general, the temperature values are as follows:
Proper Matching of the Motors to the Load
General information on the torque/speed characteristics of the various NEMA design classes is given under
“TORQUE/NEMA DESIGN CLASSES” on the following page.
The equipment manufacturer and/or user is responsible for selecting the correct motor rating to drive the load.
Ambient Temperature = The temperature of the atmosphere in which the
motor is operated 40° C is considered a standard for design purposes
Temperature Rise = The number of degrees which the insulated motor
windings heat up during motor operation
Hot Spot Allowance= The value that takes into account the additional
temperature variations within the inaccessible spots of
a motor winding These spots are located in the stator slots or coil heads 10° C is considered a standard for design purposes
InsulationClass
Max Total Temperature
Trang 15For additional product information refer to Proposal Builder.
Torque/NEMA Design Classes
The full load torque of a motor is expressed as follows:
Since different loads present different torque requirements
at starting (breakaway), minimum (pull-up), breakdown
(pull-out) and full load, the National Electrical
Manufacturers Association (NEMA) has defined four
standard design classes A,B,C and D of squirrel cage
polyphase induction motors These design classes are
summarized in Table I.
The general torque/speed relationship with the four torque
points defined is shown in Figure 1 The NEMA design
class is indicated on each price page in this catalog Most
motors are Design B with a few Design A, C & D For
motors having different characteristics than listed, contact
Rockwell Automation.
Speed/Slip
The synchronous speed of an AC motor is as follows:
The number of poles is a function of motor design Standard 60 Hz motors are available with synchronous speeds of 3600, 1800, 1200 or 900 rpm.
The actual operating speed of an AC induction motor is determined by the synchronous speed and the slip Slip is the difference between the speed of the rotating magnetic field (which is always synchronous) and the rotor speed Slip generally increases with an increase in motor torque; therefore, actual operating speed generally decreases with an increase in the driven load torque.
Service Factor
The service factor of a motor is a multiplier which, when applied to the rated horsepower, indicates a permissible horsepower loading which may be carried under the conditions specified for the service factor.
Table I Characteristics of NEMA design classes for squirrel-cage polyphase induction motors
NEMA
Design
Starting Torque
Starting Current
Breakdown Torque
Full Load Slip Typical Applications
A Normal High High Low Mach Tools, Fans
B Normal Normal Normal Normal General Industrial
C High Normal Normal Normal
LoadedCompressor,Loaded Conveyor
D Very High Low - High Punch Press or Hoists
Full load speed (rpm)
Figure 1 - General Speed/Torque relationship for squirrel-cage polyphase induction motors.
Motor torque is defined at four points as shown.
Trang 17For additional product information refer to Proposal Builder.
Evaluating Motor Efficiency
Analyze, Compare and Calculate Your Energy Savings
The graphs below show how the Allen-Bradley PE motor
efficiency and watts loss curves compare to standard
industrial averages The table below shows the results of
these comparisons in terms of annual energy savings.
Based on $.08 per kilowatt hour, 7200 hours of full load
operation per year Allen-Bradley PE TEFC motors and
Industry Averages - 4-pole, 1800 RPM Designs.
As you can see, a 150 HP PE motor could save you
$2,831 a year in power costs over standard 150 HP designs, based on electrical costs of $.08 per kilowatt hour and 7200 hours of full load operation per year The table also shows comparable savings for other motors in the PE motor line Your actual savings may vary, depending on the electrical rates, load conditions and annual operating hours of your application.
In the long term, the decision to invest in an energy efficient Allen-Bradley PE motor depends on the energy savings it can provide Actual energy savings depend upon many variables including operating hours, cost of power, duty cycles, and line voltages to name a few Tax rates and the future cost of money will also influence the decision.
However, a very simple energy savings calculation can be made to estimate the yearly energy savings with a PE motor.
Simple Energy Savings Calculation
This simple payback analysis will assume constant full load operation Note that this calculation ignores the effects of taxes and the time value of money Later, we’ll take partial load and variable duty cycles into account Information you need to know.
If actual motor efficiency is unknown, a Rockwell Automation sales engineer can help you estimate standard motor efficiencies.
First, calculate the kilowatts saved by using the PE motor:
Kilowatts Saved = HP x.746
Then, calculate the yearly energy savings:
Yearly Savings = Kilowatts Saved x Hrs/Yr x $/KWH
HP PE NOMINAL EFF IND AVE EFF WATTS SAVED MONEY SAVED
Trang 18For additional product information refer to Proposal Builder.
Example
Assume that a 25 horsepower motor is going to operate
for three 8-hour shifts per day, on a 6-day work week, for
50 weeks per year Thus, total hours per year are 7200
Also, assume the cost of electricity at $.08 per kilowatt
hour The savings, using the PE motor with an efficiency of
93%, compared to the 88% which is the industry average
for a standard efficient motor, is calculated as follows:
Yearly Savings = Kilowatts Saved x Hrs/Yr x $/KWH
In this case, the yearly savings is $656.36 In other words,
if you wanted a one-year payback on your investment, you
could afford to spend $656 more for the PE energy
efficient motor than for a standard efficient motor.
Duty Cycles
Many people question the energy savings of partial load or
variable duty cycle applications The energy saving
equations are the same However, when evaluating a
partial load operation, remember to use the horsepower,
efficiency, and appropriate hours of operation at the
desired load point A variable duty cycle calculation is
simply the summation of several partial load calculations.
Additional Savings
This payback analysis also does not take into account
many additional savings you should consider.
• Longer motor life as a result of cooler operating
temperatures
• Additional cost savings from improved power factor
• Improved partial load efficiencies of the PE motor
• Improved reliability with a more forgiving electrical
design
• Quieter operation
• Greater flexibility for use on adjustable frequency power
supplies
This is why so many companies specify Allen-Bradley PE
energy efficient motors for all their applications.
Useful Formulas
Electrical
I = Amperes: E = Volts; Eff = Efficiency; pf = Power factor;
Kva = Kilovolt-amperes; Kw = Kilowatts
HP/Torque/Speed
For Rotary Objects
For Objects In Linear Motion
Speed
Inertia Loads
Temperature Conversion - Centigrade / Fahrenheit
Temp F = (9/5 Temp C) +32 Temp C = 5/9 (Temp F – 32)
Kilowatts Saved = HP x.746 1 1STDEFF PE - EFF
To Find Alternating Current
Single Phase Three Phase
Amperes when horsepower
is known
HP x 746
E x Eff x pf
HP x 7461.73 x E x Eff x pfAmperes when kilowatts are
known
Kw x 1000
E x pf
Kw x 10001.73 x E x pfAmperes when kva are
known
Kva x 1000E
Kva x 10001.73 x EKilowatts I x E x pf1000 1.73 x I x E x pf1000
Kva 1000I x E 1.73 x I x E1000Horsepower =
(Output)
I x E x Eff x pf746
1.73 x I x E x Eff x pf746
°C °F °C °F °C °F
-30 -22 50 122 95 203-20 -4 55 131 100 212-10 14 60 140 110 230
rpm 5250
FV Where F = Force (lbs.)
HP = 33,000 V = Velocity (FPM)
RPM = 120 Frequency
No of Poles
t = WKWK2 x rpm 2 = Inertia in lb ft 2
308 x T
t = accelerating time in sec
T = Avg accelerating torque lb ft
Trang 19For additional product information refer to Proposal Builder.
Stock motors can be shipped same day or next day
Same day ship orders MUST be entered prior to 10:00 AM
(central time zone) and require customers to approve next
day freight charges All rush orders are subject to stock
availability
Sales Order Change Charges
A minimum change order charge of $100 net will apply to
orders changed more than 24 hours after order entry All
sales order changes, regardless of their nature, must be
processed through the initiation of a Sales Order Change
Request on the Passport system This includes ship-to
address changes, carrier or shipping class changes, etc
Rockwell Automation Motor
Service Centers
The following list includes all Rockwell Automation Service
Centers within the continental United States Many
inde-pendent approved service shops do exist Contact your
local Allen-Bradley distributor or sales office if one of
these service shops is not in your area.
Birmingham Regional Service Center
3100 Pinson Valley Parkway
Chicago Regional Service Center
17001 South Vincennes Road
Thorton, IL 60476
Phone: 708.877.5310
FAX: 708.877.6516
Ohio Valley Regional Service Center
2175-A Schlicter Drive
Houston Regional Service Center
1500 East Main Street LaPorte, TX 77571 Phone: 281.471.4611 FAX: 281.471.3120
Philadelphia Regional Service Center
3240 South 78th Street Philadelphia, PA 19153 Phone: 215.365.1500 FAX: 215.365.1530
Portland Regional Service Center
2315 N.W 21st Place Portland, OR 97210 Phone: 503.226.4951 FAX: 503.226.7340
Rock Springs Regional Service Center
839 Elk Street Rock Springs, WY 82901 Phone: 307.362.6697 FAX: 307.382.2618
Shreveport Regional Service Center
1245 North Hearne Avenue Shreveport, LA 71107 Phone: 318.222.9431 or (24 Hour Emergency Service - 800.366.6030) FAX: 318.424.1702
Washington Regional Service Center
320 Reliance Drive Washington, PA 15301-6196 Phone: 724.225.2900 FAX: 724.225.4309
Parts Administration
Replacement and spare parts are available for all motors offered in this catalog Spare parts not included in this catalog are available through Rockwell Automation Global Technical Support (GTS) To access parts information, record the catalog number and motor ID (identification) number from the motor nameplate and call the GTS Parts Hub.
Trang 20For additional product information refer to Proposal Builder.
Documentation
The following table indicates motor documentation and
reports that can be ordered with your Allen-Bradley motor
These catalog numbers must be ordered at the same time
the motors are ordered.
Return Requests
Stock Motors and accessories are able to be returned for
credit in many cases In cases where a return has been
authorized, the minimum re-stock charges will be 25% of
the original net price Equipment must be in original
pack-aging, un-used, have been stored per storage
require-ments identified in publication MOTOR-5.0, be a product
currently maintained in stock inventory, and must be no
more than 90 days old (reference original date of
ship-ment) Modified and build to order motors are not able to
be returned for credit Return freight charges are the
responsibility of the party returning the equipment for
on DISK
Trang 22CM101 - Enclosed EE Rolled Steel AC Motors
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
TEFC 1.5 1200 230/460 EE CT 10:1 Yes 182T FC1F512AEHHA 9 $578
TEFC 2 1200 230/460 EE CT 10:1 Yes 184T FC00212AEHHA 9 $630
TEFC 3600 230/460 EE CT 10:1 Yes 182T FC00336AEHHA 9 $575
TEFC 1800 230/460 EE CT 10:1 Yes 182T FC00318AEHHA 9 $507
TEFC 1200 230/460 EE CT 10:1 Yes 213T FC00312AEHHA 9 $702
TEFC 3600 230/460 EE CT 10:1 Yes 184T FC00536AEHHA 9 $658
TEFC 1800 230/460 EE CT 10:1 Yes 184T FC00518AEHHA 9 $571
TEFC 1200 230/460 EE CT 10:1 Yes 215T FC00512AEHHA 9 $955
TEFC 3600 230/460 EE CT 10:1 Yes 213T FC7F536AEHHA 9 $782
TEFC 1800 230/460 EE CT 10:1 Yes 213T FC7F518AEHHA 9 $688
TEFC 1200 230/460 EE CT 4:1 Yes 254T FC7F512AEKHA 9 $1,197
TEFC 3600 230/460 EE CT 10:1 Yes 215T FC01036AEHHA 9 $901
TEFC 1800 230/460 EE CT 10:1 Yes 215T FC01018AEHHA 9 $755
TEFC 1200 230/460 EE CT 4:1 Yes 256T FC01012AEKHA 9 $1,454
TEFC 3600 230/460 EE CT 4:1 Yes 254T FC01536AEKHA 9 $1,159
TEFC 1800 230/460 EE CT 4:1 Yes 254T FC01518AEKHA 9 $1,062
TEFC 1200 230/460 EE CT 2:1 Yes 284T FC01512AEJHA 9 $1,741
TEFC 3600 230/460 EE CT 4:1 Yes 256T FC02036AEKHA 9 $1,383
TEFC 1800 230/460 EE CT 4:1 Yes 256T FC02018AEKHA 9 $1,256
TEFC 1200 230/460 EE CT 2:1 Yes 286T FC02012AEJHA 9 $2,115
TEFC 3600 230/460 EE CT 2:1 Yes 284TS FC02536AEJHA 9,39 $1,561
TEFC 1800 230/460 EE CT 2:1 Yes 284T FC02518AEJHA 9 $1,498
TEFC 3600 230/460 EE CT 2:1 Yes 286TS FC03036AEJHA 9,39 $1,826
TEFC 1800 230/460 EE CT 2:1 Yes 286T FC03018AEJHA 9 $1,741
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
TEFC 1.5 1200 230/460 EE CT 10:1 Yes 182TCY FC1F512AEHCA 9 $647
TEFC 2 1200 230/460 EE CT 10:1 Yes 184TCY FC00212AEHCA 9 $699
TEFC 3600 230/460 EE CT 10:1 Yes 182TCY FC00336AEHCA 9 $643
TEFC 1800 230/460 EE CT 10:1 Yes 182TCY FC00318AEHCA 9 $576
TEFC 1200 230/460 EE CT 10:1 Yes 213TCY FC00312AEHCA 9 $770
TEFC 3600 230/460 EE CT 10:1 Yes 184TCY FC00536AEHCA 9 $726
TEFC 1800 230/460 EE CT 10:1 Yes 184TCY FC00518AEHCA 9 $639
TEFC 1200 230/460 EE CT 10:1 Yes 215TCY FC00512AEHCA 9 $1,023
TEFC 3600 230/460 EE CT 10:1 Yes 213TCY FC7F536AEHCA 9 $851
TEFC 1800 230/460 EE CT 10:1 Yes 213TCY FC7F518AEHCA 9 $757
TEFC 1200 230/460 EE CT 4:1 Yes 254TCY FC7F512AEKCA 9 $1,287
TEFC 3600 230/460 EE CT 10:1 Yes 215TCY FC01036AEHCA 9 $969
TEFC 1800 230/460 EE CT 10:1 Yes 215TCY FC01018AEHCA 9 $823
TEFC 1200 230/460 EE CT 4:1 Yes 256TCY FC01012AEKCA 9 $1,543
TEFC 3600 230/460 EE CT 4:1 Yes 254TCY FC01536AEKCA 9 $1,249
TEFC 1800 230/460 EE CT 4:1 Yes 254TCY FC01518AEKCA 9 $1,151
TEFC 1200 230/460 EE CT 2:1 Yes 284TC FC01512AEJCA 9 $1,865
TEFC 3600 230/460 EE CT 4:1 Yes 256TCY FC02036AEKCA 9 $1,473
TEFC 1800 230/460 EE CT 4:1 Yes 256TCY FC02018AEKCA 9 $1,345
TEFC 1200 230/460 EE CT 2:1 Yes 286TC FC02012AEJCA 9 $2,239
TEFC 3600 230/460 EE CT 2:1 Yes 284TSC FC02536AEJCA 9,39 $1,685
TEFC 1800 230/460 EE CT 2:1 Yes 284TC FC02518AEJCA 9 $1,622
TEFC 3600 230/460 EE CT 2:1 Yes 286TSC FC03036AEJCA 9,39 $1,950
TEFC 1800 230/460 EE CT 2:1 Yes 286TC FC03018AEJCA 9 $1,865
Trang 23Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
TEFC 1.5 1200 230/460 EE CT 10:1 Yes 182TC FC1F512AEHFA 9 $663TEFC 2 1200 230/460 EE CT 10:1 Yes 184TC FC00212AEHFA 9 $715TEFC 3600 230/460 EE CT 10:1 Yes 182TC FC00336AEHFA 9 $659TEFC 1800 230/460 EE CT 10:1 Yes 182TC FC00318AEHFA 9 $592TEFC 1200 230/460 EE CT 10:1 Yes 213TC FC00312AEHFA 9 $787TEFC 3600 230/460 EE CT 10:1 Yes 184TC FC00536AEHFA 9 $742TEFC 1800 230/460 EE CT 10:1 Yes 184TC FC00518AEHFA 9 $655TEFC 1200 230/460 EE CT 10:1 Yes 215TC FC00512AEHFA 9 $1,039TEFC 3600 230/460 EE CT 10:1 Yes 213TC FC7F536AEHFA 9 $867TEFC 1800 230/460 EE CT 10:1 Yes 213TC FC7F518AEHFA 9 $773TEFC 1200 230/460 EE CT 4:1 Yes 254TC FC7F512AEKFA 9 $1,326TEFC 3600 230/460 EE CT 10:1 Yes 215TC FC01036AEHFA 9 $986TEFC 1800 230/460 EE CT 10:1 Yes 215TC FC01018AEHFA 9 $840TEFC 1200 230/460 EE CT 4:1 Yes 256TC FC01012AEKFA 9 $1,582TEFC 3600 230/460 EE CT 4:1 Yes 254TC FC01536AEKFA 9 $1,287TEFC 1800 230/460 EE CT 4:1 Yes 254TC FC01518AEKFA 9 $1,190TEFC 1200 230/460 EE CT 2:1 Yes 284TC FC01512AEJFA 9 $1,923TEFC 3600 230/460 EE CT 4:1 Yes 256TCY FC02036AEKFA 9 $1,511TEFC 1800 230/460 EE CT 4:1 Yes 256TCY FC02018AEKFA 9 $1,384TEFC 1200 230/460 EE CT 2:1 Yes 286TC FC02012AEJFA 9 $2,297TEFC 3600 230/460 EE CT 2:1 Yes 284TSC FC02536AEJFA 9,39 $1,743TEFC 1800 230/460 EE CT 2:1 Yes 284TC FC02518AEJFA 9 $1,680TEFC 3600 230/460 EE CT 2:1 Yes 286TSC FC03036AEJFA 9,39 $2,008TEFC 1800 230/460 EE CT 2:1 Yes 286TC FC03018AEJFA 9 $1,923
15
202530
Trang 24Modifications Available to CM101 Motors
CONNECTIONS: Final connect dual to single voltage.
DRIP COVERS: Mounting of stock canopy kits (price includes kit).
116 Install canopy kit to allow for vertical shaft down operation 180-210 $216
Note: This modification does not provide vertical lifting provisions 250-280 $270
LEAD TERMINALS: Addition of lead terminals to wires in conduit box.
135 Compression type (Burndy, etc.) lead lugs All $270
MOUNTING: Move conduit box to allow different mounting configurations.
SEALS: Addition of shaft seal.
148 Additon of V-ring rubber slinger on drive end All $216
THERMAL PROTECTION: Addition of thermostats.
Standard in Component Class Motors All incl
160 Removal of standard thermostats from motor (deduct from List Price) 48-280 -$208
Note: User must insure that NEC 2005 is met for inverter duty motor 320-449 -$313
To cancel an order for a motor after it is modified, but before it ships - a cancellation charge of double the
modification charge will be invoiced to the customer Any MOD order cancelled before modification is completed is
subject to 25% cancellation charge.
The delivery cycle will be subject to the availability of stock motors and parts The Modification Center is designed
to process and ship units as quickly as possible; therefore, “Hold for Approval” and other similar conditions are not
available on Modification Center orders Typically, modifications will require 1 to 4 business days, once the order is
entered Orders for more than 5 units may require additional delivery time The lead time shown on a Passport
screen is for the base motor only, modifications will add to actual lead time.
Trang 25For additional product information refer to Proposal Builder.
Component Class
Inverter Duty General Purpose Series
CM102 Family - Enclosed EE Cast Iron AC Motors
Application Information
Cast Iron general purpose CM102 AC motors are an ideal choice for applications such as: Fans,
Blowers, Compressors, Pumps and Conveyors.
(24 / 12)
Nameplate Agency Approvals:
CE, CSA, UR
180T - 360T Frames
and fan cover (180T - 210T frames), Cast Iron frame, end shields, conduit box and fan cover (320T - 360T frames).
Drain Type & Location: Weep holes both ends
requirements by staying corona free at up to 1600V peaks, and 10,000V/µSec dV/dT.
Trang 26CM102 - Enclosed EE Cast Iron AC Motors
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
RPM Class Torque/Spd Stock CM102- Price
TEFC 3 3600 230/460 EE CT 10:1 Yes 182T FC00336AEHHA 9 $605
TEFC 3 3600 575 EE CT 10:1 Yes 182T FC00336CEHHA 9 $605
TEFC 3 1800 230/460 EE CT 10:1 Yes 182T FC00318AEHHA 9 $575
TEFC 3 1800 575 EE CT 10:1 Yes 182T FC00318CEHHA 9 $575
TEFC 3 1200 230/460 EE CT 10:1 Yes 213T FC00312AEHHA 9 $742
TEFC 3 1200 575 EE CT 10:1 Yes 213T FC00312CEHHA 9 $742
TEFC 5 3600 230/460 EE CT 4:1 Yes 184T FC00536AEKHA 9 $693
TEFC 5 3600 575 EE CT 4:1 Yes 184T FC00536CEKHA 9 $693
TEFC 5 1800 230/460 EE CT 4:1 Yes 184T FC00518AEKHA 9 $651
TEFC 5 1800 575 EE CT 4:1 Yes 184T FC00518CEKHA 9 $651
TEFC 5 1200 230/460 EE CT 10:1 Yes 215T FC00512AEHHA 9 $1,015
TEFC 5 1200 575 EE CT 10:1 Yes 215T FC00512CEHHA 9 $1,015
TEFC 7.5 3600 230/460 EE CT 4:1 Yes 213T FC7F536AEKHA 9 $828
TEFC 7.5 3600 575 EE CT 4:1 Yes 213T FC7F536CEKHA 9 $828
TEFC 7.5 1800 230/460 EE CT 4:1 Yes 213T FC7F518AEKHA 9 $797
TEFC 7.5 1800 575 EE CT 4:1 Yes 213T FC7F518CEKHA 9 $797
TEFC 7.5 1200 230/460 EE CT 10:1 Yes 254T FC7F512AEHHA 9 $1,372
TEFC 7.5 1200 575 EE CT 10:1 Yes 254T FC7F512CEHHA 9 $1,372
TEFC 10 3600 230/460 EE CT 2:1 Yes 215T FC01036AEJHA 9 $956
TEFC 10 3600 575 EE CT 2:1 Yes 215T FC01036CEJHA 9 $956
TEFC 10 1800 230/460 EE CT 2:1 Yes 215T FC01018AEJHA 9 $878
TEFC 10 1800 575 EE CT 2:1 Yes 215T FC01018CEJHA 9 $878
TEFC 10 1200 230/460 EE CT 4:1 Yes 256T FC01012AEKHA 9 $1,674
TEFC 10 1200 575 EE CT 4:1 Yes 256T FC01012CEKHA 9 $1,674
TEFC 15 3600 230/460 EE CT 4:1 Yes 254T FC01536AEKHA 9 $1,327
TEFC 15 3600 575 EE CT 4:1 Yes 254T FC01536CEKHA 9 $1,327
TEFC 15 1800 230/460 EE CT 2:1 Yes 254T FC01518AEJHA 9 $1,213
TEFC 15 1800 575 EE CT 2:1 Yes 254T FC01518CEJHA 9 $1,213
TEFC 15 1200 230/460 EE CT 10:1 Yes 284T FC01512AEHHA 9 $2,011
TEFC 15 1200 575 EE CT 10:1 Yes 284T FC01512CEHHA 9 $2,011
TEFC 20 3600 230/460 EE CT 2:1 Yes 256T FC02036AEJHA 9 $1,590
TEFC 20 3600 575 EE CT 2:1 Yes 256T FC02036CEJHA 9 $1,590
TEFC 20 1800 230/460 EE CT 2:1 Yes 256T FC02018AEJHA 9 $1,441
TEFC 20 1800 575 EE CT 2:1 Yes 256T FC02018CEJHA 9 $1,441
TEFC 20 1200 230/460 EE CT 4:1 Yes 286T FC02012AEKHA 9 $2,450
TEFC 20 1200 575 EE CT 4:1 Yes 286T FC02012CEKHA 9 $2,450
TEFC 25 3600 230/460 EE CT 4:1 Yes 284TS FC02536AEKHA 9 $1,801
TEFC 25 3600 575 EE CT 4:1 Yes 284TS FC02536CEKHA 9 $1,801
TEFC 25 1800 230/460 EE CT 2:1 Yes 284T FC02518AEJHA 9 $1,726
TEFC 25 1800 575 EE CT 2:1 Yes 284T FC02518CEJHA 9 $1,726
TEFC 25 1200 230/460 EE CT 4:1 Yes 324T FC02512AEKHA 9 $2,980
TEFC 25 1200 575 EE CT 4:1 Yes 324T FC02512CEKHA 9 $2,980
TEFC 30 3600 230/460 EE CT 10:1 Yes 286TS FC03036AEHHA 9 $2,112
TEFC 30 3600 575 EE CT 10:1 Yes 286TS FC03036CEHHA 9 $2,112
TEFC 30 1800 230/460 EE CT 2:1 Yes 286T FC03018AEJHA 9 $2,011
TEFC 30 1800 575 EE CT 2:1 Yes 286T FC03018CEJHA 9 $2,011
TEFC 30 1200 230/460 EE CT 4:1 Yes 326T FC03012AEKHA 9 $3,282
TEFC 30 1200 575 EE CT 4:1 Yes 326T FC03012CEKHA 9 $3,282
TEFC 40 3600 230/460 EE CT 4:1 Yes 324TS FC04036AEKHA 9 $2,692
TEFC 40 3600 575 EE CT 4:1 Yes 324TS FC04036CEKHA 9 $2,692
TEFC 40 1800 230/460 EE CT 2:1 Yes 324T FC04018AEJHA 9 $2,670
TEFC 40 1800 575 EE CT 2:1 Yes 324T FC04018CEJHA 9 $2,670
TEFC 40 1200 230/460 EE CT 2:1 Yes 364T FC04012AEJHA 9 $4,448
TEFC 40 1200 575 EE CT 2:1 Yes 364T FC04012CEJHA 9 $4,448
Trang 27RPM Class Torque/Spd Stock CM102- Price
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
Trang 28Modifications Available to CM102 Motors
CONNECTIONS: Final connect dual to single voltage.
107 High Voltage Connection (price by frame size) 180-320 $162
108 Low Voltage Connection (price by frame size) 360 $216
LEAD TERMINALS: Addition of lead terminals to wires in conduit box.
135 Compression type (Burndy, etc.) lead lugs All $270
MOUNTING: Move conduit box to allow different mounting configurations.
THERMAL PROTECTION: Addition of thermostats.
Standard in Component Class Motors All incl
160 Removal of standard thermostats from motor (deduct from List Price) 48-280 -$208
Note: User must insure that NEC 2005 is met for inverter duty motor 320-449 -$313
To cancel an order for a motor after it is modified, but before it ships - a cancellation charge of double the
modification charge will be invoiced to the customer Any MOD order cancelled before modification is
completed is subject to 25% cancellation charge.
The delivery cycle will be subject to the availability of stock motors and parts The Modification Center is
designed to process and ship units as quickly as possible; therefore, “Hold for Approval” and other similar
conditions are not available on Modification Center orders Typically, modifications will require 1 to 4
business days, once the order is entered Orders for more than 5 units may require additional delivery time
The lead time shown on a Passport screen is for the base motor only, modifications will add to actual lead
Trang 29For additional product information refer to Proposal Builder.
Component Class
Inverter Duty General Purpose Series
CM103 Family - Enclosed EE/PE/NP AC Motors
Construction Features
EPAct efficiency levels
exceed EPAct efficiency levels
NP = NEMA Premium efficient motors
Application Information
Designed for all general purpose industrial applications in a dusty, dirty, and/or humid
environment Enclosed motors reduce the exchange of air between the inside and the
outside of the motor.
Warranty (From Date Of Manufacture /
Drain Type & Location: Weep hole in both end shields
MG1 Part 31.4.4.2 requirements by staying corona free at up to 1600V peaks, and 10,000V/µSec dV/dT.
180T - 449T Frames
360T frames); regreasable, open ball bearings with PLS (400T - 449T frames)
Drain Type & Location: Weep holes in both end shields
MG1 Part 31.4.4.2 requirements by staying corona free at up to 1600V peaks, and 10,000V/µSec dV/dT.
Trang 30CM103 - Enclosed SE/EE/PE/NP AC Motors
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
Trang 31RPM Class Torque/Spd Stock CM103- Price
Trang 32RPM Class Torque/Spd Stock CM103- Price
Trang 33RPM Class Torque/Spd Stock CM103- Price
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
Trang 34RPM Class Torque/Spd Stock CM103- Price
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
Trang 35RPM Class Torque/Spd Stock CM103- Price
Trang 36RPM Class Torque/Spd Stock CM103- Price
(2) Note: VT 10:1 (2) = Variable Torque 10:1 Speed Range (capable of 2:1 CT with fan change), must add modification code 126
(10) Note: CT 2:1 (10) = Constant Torque 2:1 Speed Range (capable of 10:1 CT with fan change), must add modification code 126
(10) Note: CT 4 :1 (10) = Constant Torque 4:1 Speed Range (capable of 10:1 CT with fan change), must add modification code 126
Trang 37Modifications Available to CM103 Motors
CONDUIT BOX: Mounting of stock box kits (price includes box).
CONNECTIONS: Final connect dual to single voltage.
DRAINS: Install one automatic breather drain in each motor end bracket Note: Mounting position must be specified.
DRIP COVERS: Mounting of stock canopy kits (price includes kit).
Note: This modification does not provide vertical lifting provisions 180-210 $251
END BRACKET: Modify a foot mounted motor to include a C-Face end bracket.
Note: Please add seal modification seperately if required
Non-Nafta motors are non-NEMA BA
FAN CHANGE: Install larger fan.
126 Convert to larger fan for increased Constant Torque speed range on inverter 180-280 $314 103
GREASE FITTINGS: Install a grease fitting on each bearing.
LEAD TERMINALS: Addition of lead terminals to wires in conduit box.
MILL AND CHEMICAL DUTY: Add features for additional reliability in Mill and Chem duty applications.
To cancel an order for a motor after it is modified, but before it ships - a cancellation charge of double the modification charge will be invoiced to the customer Any MOD order cancelled before modification is completed is subject to 25% cancellation charge.
The delivery cycle will be subject to the availability of stock motors and parts The Modification Center is designed to process and ship units as quickly as possible; therefore, “Hold for Approval” and other similar conditions are not available on
Modification Center orders Typically, modifications will require 1 to 4 business days, once the order is entered Orders for more than 5 units may require additional delivery time The lead time shown on a Passport screen is for the base motor only, modifications will add to actual lead time.
Trang 38Modifications Available to CM103 Motors
MOUNTING: Move conduit box to allow different mounting configurations.
SEALS: Addition of shaft seal.
THERMAL PROTECTION: Addition of thermostats.
160 Removal of standard thermostats from motor (deduct from List Price) 48-280 -$208
Note: User must insure that NEC 2005 is met for inverter duty motor 320-449 -$313
Trang 39For additional product information refer to Proposal Builder.
Component Class
Inverter Duty General Purpose Series
CM106 Family - Open EE Rolled Steel AC Motors
Application Information
Rolled steel general purpose CM106 AC motors are an ideal choice for applications such as: Fans,
Blowers, Compressors, Pumps & Conveyors.
(24 / 12)
Nameplate Agency Approvals:
CE, CSA, UR
180T - 280T Frames
shields with steel bearing inserts (180T - 210T frames), Cast Iron end shields (250T - 280T frames) All C-face brackets are Cast Iron.
Drain Type & Location: Weep holes on both end shields
requirements by staying corona free at up to 1600V peaks, and 10,000V/µSec dV/dT.
Trang 40CM106 - Open EE Rolled Steel AC Motors
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List
Enclosure HP Synch Voltage Efficiency Inverter Norm Frame Catalog String Notes US List