www bzfxw com Copyright British Standard Reproduced by IHS under No reproduction or network ` , , ` , , , ` ` , , ` , , ` , ` , , ` BRITISH STANDARD BS EN 50086 2 2 1996 Incorporating Amendment No 1 a[.]

Trang 1

BRITISH STANDARD BS EN

50086-2-2:1996

Incorporating Amendment No 1 and Corrigendum No 1

Specification for

Conduit systems for cable management —

Part 2: Particular requirements — Section 2.2: Pliable conduit systems

The European Standard EN 50086-2-2:1995 with the incorporation of amendment A11:1998 has the status of a British Standard

This British Standard should be read in conjunction with

BS EN 50086-1:1994

ICS 29.120.10

NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW

Copyright British Standards Institution

Reproduced by IHS under license with BSI - Uncontrolled Copy

Trang 2

`,,`,,,-`-`,,`,,`,`,,` -This British Standard, having

been prepared under the

direction of the

Electrotechnical Sector Board,

was published under the

authority of the Standards

Board and comes into effect on

15 April 1996

© BSI 26 February 2002

The following BSI references

relate to the work on this

standard:

Committee reference PEL/113

Draft for comment 92/04072 DC

ISBN 0 580 25528 X

Committees responsible for this British Standard

The preparation of this British Standard was entrusted to Technical Committee PEL/113, Cable management, upon which the following bodies were represented:

ASTA Certification Services British Electrical Systems Association (BEAMA Ltd.) British Telecommunications plc

Electrical Installation Equipment Manufacturers’ Association Electricity Association

Gland Manufacturers’ Technical Committee Institution of Electrical Engineers

Institution of Incorporated Executive Engineers

Amendments issued since publication

10514 January 2000 Deletion from Annex AA of

A-deviations for Finland

13546

Corrigendum No 1 26 February 2002 Correction to title of standard

Trang 3

`,,`,,,-`-`,,`,,`,`,,` -BS EN 50086-2-2:1996

Contents

Page Committees responsible Inside front cover

Copyright British Standards Institution

Reproduced by IHS under license with BSI - Uncontrolled Copy

Trang 4

`,,`,,,-`-`,,`,,`,`,,` -National foreword

This British Standard has been prepared by Technical Committee PEL/113 and

is the English language version of EN 50086-2-2:1995, Conduit systems for cable

management — Part 2-2 Particular requirements for pliable conduit systems,

including amendment A11:1998 and corrigendum February 2001, published by the European Committee for Electrotechnical Standardization (CENELEC)

This British Standard is to be read in conjunction with BS EN 50086-1:1994

Specification for conduit systems for cable management — Part 1: General requirements The references to Part 1 should be read as references to

BS EN 50086-1:1994 which is the English language version of EN 50086-1:1993

A British Standard does not purport to include all the necessary provisions of a contract Users of British Standards are responsible for their correct application

Compliance with a British Standard does not of itself confer immunity from legal obligations.

Summary of pages

This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 9 and a back cover

The BSI copyright notice displayed in this document indicates when the document was last issued

Trang 5

EUROPEAN STANDARD

NORME EUROPÉENNE

EUROPÄISCHE NORM

EN 50086-2-2

May 1995

+ A11

December 1998

ICS 29.120.10 Incorporating corrigendum February 2001

Descriptors: Electric wiring system, pliable conduit, mechanical characteristics, electrical characteristics, test

English version

Conduit systems for cable management — Part 2-2: Particular requirements for pliable conduit

systems

(includes amendment A11:1998)

Systèmes de conduits pour la gestion du

câblage —

Partie 2-2: Règles particulières pour systèmes

de conduits cintrables

(inclut l’amendement A11:1998)

Installationsrohrsysteme zum Führen von Leitungen für elektrische Energie und für Information —

Teil 2-2: Besondere Anforderungen für biegsame Elektroinstallationsrohrsysteme (enthält Änderung A11:1998)

This European Standard was approved by CENELEC on 1994-12-06 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration

Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member

This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions

CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom

CENELEC

European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B-1050 Brussels

© 1995 Copyright reserved to CENELEC members

Ref No EN 50086-2-2:1995 + A11:1998 E

Copyright British Standards Institution

Reproduced by IHS under license with BSI - Uncontrolled Copy

Trang 6

Foreword

This European Standard has been prepared by

CENELEC Technical Committee TC 113, Cable

management systems

The text of the draft was submitted to the formal

vote and was approved by CENELEC as

EN 50086-2-2 on 1994-12-06

This Part 2-2 specifies particular requirements for

pliable conduit systems

A conduit system which complies with this standard

is deemed safe for use

The following dates were fixed:

For products which have complied with the relevant

national standard before 1996-12-01, as shown by

the manufacturer or by a certification body, this

previous standard may continue to apply for

production until 2001-12-01

This Part 2-2 supplements or modifies the

corresponding clauses of EN 50086-1:1993, Conduit

systems for cable management — Part 1: General

requirements.

Where a particular clause or subclause of Part 1 is

not mentioned in this Part 2-2, that clause or

subclause applies as far as is reasonable Where this

Part 2-2 states “addition”, “modification” or

“replacement”, the relevant text of Part 1 is to be

adapted accordingly

Subclauses, tables and figures which are in addition

to those in Part 1 are numbered starting with 101

Annexes which are in addition to those in Part 1 are

labelled AA, BB, etc

Foreword to amendment A11

At the request of the Finnish electrotechnical

committee, a draft for an amendment to

EN 50086-2-2:1995 was submitted to the

CENELEC members for acceptance in

October 1998

The text of the draft was accepted by CENELEC as

amendment A11 to EN 50086-2-2:1995 on

1998-12-16

The following dates were fixed:

Contents

Page

2 Normative references 3

4 General requirements 3

5 General conditions for tests 3

7 Marking and documentation 3

10 Mechanical properties 4

11 Electrical properties 5

14 External influences 6

15 Electromagnetic compatibility 7

Annex AA (informative) A-deviations 7 Figure 101 — Bending test apparatus 7 Figure 102 — Gauge for checking the

minimum inside diameter after bending and resistance to heat tests 8 Figure 103 — Assembly of conduit and

terminating fitting for bonding test 8 Table 101 — Thread lengths 4 Table 102 — Maximum entry diameter

and minimum entry length details 4

— latest date by which the

EN has to be implemented

at national level by

publication of an identical

national standard or by

endorsement (dop) 1995-12-01

— latest date by which the

national standards

conflicting with the EN

have to be withdrawn (dow) 1996-12-01

— latest date by which the existence of the

amendment has to be announced at national

— latest date by which the amendment has to be implemented at national level by publication of an identical national

standard or by endorsement (dop) 1999-06-16

Trang 7

EN 50086-2-2:1995

1 Scope

This clause of Part 1 is applicable, except as follows

Addition:

This standard specifies the requirements for pliable conduit systems including self-recovering conduit systems

Conduit systems which are used as an integral part of other equipment also have to be tested according to the relevant standard for that equipment

2 Normative references

This clause of Part 1 is applicable

3 Definitions

This clause of Part 1 is applicable

4 General requirements

This clause of Part 1 is applicable

5 General conditions for tests

This clause of Part 1 is applicable

6 Classification

This clause of Part 1 is applicable, except as follows 6.1.1.1, 6.1.2.1, 6.1.3.1, 6.1.3.4, 6.1.4.1 and 6.1.5.1 are

not applicable

7 Marking and documentation

This clause of Part 1 is applicable, except as follows

Addition:

7.1.101 The conduit shall be marked in accordance with 7.1 at regular intervals along its length of

preferably 1 m but not longer than 3 m Where this is technically impractical, the mark shall be on a label attached to the product at each end

Compliance is checked by inspection.

7.1.102 The manufacturer shall document for the system the minimum inside diameter and the

classification in accordance with clause 6.

Compliance is checked by inspection.

8 Dimensions

Replacement:

8.1 Threads shall comply with EN 60423.

Outside diameters of non-metallic conduits shall comply with EN 60423

Outside diameters of metallic and composite conduits need not comply with EN 60423, providing they are used with terminating fittings with threads complying with EN 60423

Compliance is checked by means of the gauges specified in EN 60423.

8.2 Threadable conduits and threadable conduit fittings shall comply with Table 101 Non-threadable

conduit fittings shall comply with Table 102 The minimum inside diameter of the conduit system shall be declared by the manufacturer

Compliance is checked by measurement.

Copyright British Standards Institution

Reproduced by IHS under license with BSI - Uncontrolled Copy

Trang 8

Table 101 — Thread lengths

Table 102 — Maximum entry diameter and minimum entry length details

9 Construction

This clause of Part 1 is applicable

10 Mechanical properties

This clause of Part 1 is applicable, except as follows

10.2 Compression test

For self-recovering conduits, instead of 10.2.4, 10.2.5, 10.2.6, 10.2.7 and 10.2.8, the following applies.

10.2.101 The intermediate piece shall be submitted to a constantly increasing compression force (N)

determined in such a way as to flatten the sample by an amount exceeding 25 % but not exceeding 50 % of

its initial outside diameter within 30 s The compression force shall not be less than the values given

in Table 4

The force and the intermediate piece shall then be removed Fifteen minutes after removal, the outside

diameter of the sample, where it has flattened, shall be measured again

After the test, the difference between the initial outside diameter and the outside diameter of the flattened

sample shall not exceed 10 % of the outside diameter, as measured before the test and the sample shall

show no cracks visible to normal or corrected vision without magnification

Size External thread Internal thread

Minimum length

(mm) Minimum length (mm)

6

8

10

12

16

20

25

32

40

50

63

75

05,5 06,5 08,5 10,5 12,5 14,0 17,0 19,0 19,0 19,0 19,0 19,0

06,5 07,5 09,5 11,5 13,5 15,0 18,0 20,0 20,0 20,0 20,0 20,0

Size Maximum entry diameter

(mm)

Minimum entry length

(mm)

6

8

10

12

16

20

25

32

40

50

63

75

06,5 08,5 10,5 12,5 16,5 20,5 25,5 32,6 40,7 50,8 63,9 75,9

06,0 08,0 10,0 12,0 16,0 20,0 25,0 30,0 32,0 42,0 50,0 50,0

Trang 9

EN 50086-2-2:1995

10.4 Bending test 10.4.101 Conduits shall be subjected to a bending test by means of the apparatus shown in Figure 101.

10.4.102 The test shall be made on six samples of conduit, the length of each sample being at least:

a) 30 times the nominal outside diameter for plain conduits;

b) 12 times the nominal outside diameter for corrugated conduits

Three of the samples shall be tested at the ambient temperature; the other three shall be tested at the declared transport, permanent application and installation temperature in accordance with Table 1 with a tolerance of ±2 °C

10.4.103 For the test at ambient temperature, the sample shall be clamped vertically in the bending

apparatus in accordance with Figure 101 The sample shall be slowly bent by hand to the left through approximately 90°, back to the vertical position, to the right through approximately 90°, and back to the vertical position This sequence of operations shall be repeated three more times but at the end the sample shall not be bent back to the vertical position The sample shall be maintained in the bent position for 5 min, after which it shall be placed in such a position that the straight portions are at 45° to the vertical, one end of the sample pointing upwards and the other downwards

For the test at the declared transport, permanent application and installation temperature, the sample clamped in the bending apparatus as shown in Figure 101 shall be conditioned for 2 h in a cold chamber at this temperature ±2 °C

After the test, the sample shall show no cracks visible to normal or corrected vision without magnification and it shall be possible to pass the appropriate gauge, in accordance with Figure 102, through the sample under its own weight and without any initial speed

10.5 Flexing test

This subclause of Part 1 is not applicable

10.6 Collapse test

This subclause of Part 1 is not applicable

10.7 Tensile strength

This subclause of Part 1 is applicable, except as follows

10.7.3 is not applicable.

11 Electrical properties

This clause of Part 1 is applicable, except as follows

11.5 Bonding test Replacement:

A sample of conduit and terminating fitting shall be assembled in accordance with the manufacturer’s instructions and Figure 103 A current of 25 A, having a frequency of 50 Hz to 60 Hz, derived from an a.c source having a no-load voltage not exceeding 12 V, shall be passed through the assembly for 1 min s, after which the voltage drop shall be measured between the points shown in Figure 103 and the resistance calculated from the current and this voltage drop

The resistance shall not exceed 0,05 %

Where special devices are required for the coupling of conduit and terminating fitting, it shall be sufficient

to remove the protective coating from the conduit, or the protective finish shall be removed in accordance with the manufacturer’s instructions before the voltage is applied

+5 0

Copyright British Standards Institution

Reproduced by IHS under license with BSI - Uncontrolled Copy

Trang 10

12 Thermal properties

This clause of Part 1 is applicable, except as follows

12.2.4 Replacement:

The load is then removed and immediately after its removal it shall be possible to pass the appropriate

gauge, in accordance with Figure 102, through the conduit under its own weight and without any initial

speed, with the sample in the vertical position

13 Fire effects

This clause of Part 1 is applicable

14 External influences

This clause of Part 1 is applicable, except as follows

14.1.1.2 Addition:

When tested for first numeral 5 or 6, the assembly shall be tested as a category 2 enclosure

14.1.2.2 Addition:

When tested for second numeral 3 or 4, the assembly shall be tested using the oscillating tube