Fiber Termination Blocks FTBFiber Termination Blocks FTBs are available with SC, FC, ST®and E-2000 adapters in block configurations of 48, 72 or 96 positions.. Fiber Combination Blocks B

Trang 1

Fiber Termination Blocks (FTB)

Fiber Termination Blocks (FTBs) are available with SC, FC, ST®and E-2000 adapters in block configurations

of 48, 72 or 96 positions Also, 144 position FTBs are available using LX.5®and LC adapters FTBs utilizesliding adapter packs to gain easy access to both the front and rear connectors There is also a blockconfiguration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiringsplitters or WDMs FTBs can be ordered with or without IFC or outside plant cable

Fiber Combination Blocks Blocks (FCB)

Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block.The block occupies two mounting positions on the frame section They are available with SC, FC, ST®andE-2000 adapters in block configurations of 48, 72 or 96 positions Also, 144 position FCBs are availableusing LX.5®or LC adapters

Features and Benefits

Ample Trough Space

Reduces jumper pile-up and congestion

- Reduces maintenance time due to easy removal and tracing of jumpers

- Minimizes risk of microbends or damage

to fiber

Built-in Jumper Storage Panel

Minimizes number of required jumper lengths

Maintains fiber bend radius

Simplifies frame installation

- Saves money by reducing the number of

different jumper lengths that have to be kept

in inventory

- Minimizes risk of microbends or damage

to fiber

Sliding Adapter Packs

Promotes high density Provides easy access to connectors

- Saves valuable floor space

- Reduces time required for operations and maintenance

Intelligent Cable Routing System

No fiber cross-over points Multiple vertical troughways

- Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber “weaving”

Trang 2

10/03 • 100571

Fiber Main Distributing Frame (FMDF)

The FMDF is the cornerstone of the NGF product line This innovative frame has six rear horizontal troughs.This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability andremoval The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided betweenvertical columns on the left and right sides of the frame as shown in the figure below The frame is 600 mmwide x 600 mm deep The built-in jumper storage panel will store up to 5 meters of jumper slack

Right Vertical

Left

Trough (6) Jumper

Storage Panel

Trang 3

Front Facing Fiber Main Distributing Frame (F3MDF)

The F3MDF is designed for single-sided access applications and may be mounted up against a wall or to-back to save floor space Unlike the FMDF, the more compact F3MDF is equipped with a single 230 mmhorizontal trough The F3MDF has twelve FTB mounting positions equally divided between vertical columns

back-on the left and right sides of the frame as shown in the figure below The frame is 600 mm wide x 480 mmdeep The built-in jumper storage panel will store up to 5 meters of jumper slack

2.2 m

Jumper Storage Panel

Right Vertical

Left Vertical

FTB Mounting Position (12)

Horizontal Trough (6)

Trang 4

Fiber Slim Rack

The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF It has six FTBmounting positions and is designed for single-sided access applications The Slim Rack is intended foruse in a single frame application and should not be used in a multiframe lineup The built-in jumperstorage panel will store up to 5 meters of jumper slack

When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used

Trang 5

Block Style

1 2 3 4

1

3

SC FC/ST ®

E-2000 LX.5 ® /LC

Cable Exit Direction

U D

Upward Downward

Block Configuration

A B C M

48 72 96

144 (LX.5 ® or LC only)*

Block Orientation

L R

Left Right

Adapter Type (62.5/125) Multimode

9 A 5 Y P

SC FC

ST ®

LX.5 ®

(144 only)

LC (144 only)

OR

Adapter Type Singlemode

7 8 L 2 3 Q 4 V N X K

SC ultra polish

SC ultra polish, zirconia sleeve

SC 8 ° angled polish

FC ultra polish

FC ultra polish, zirconia sleeve

FC 8 ° angled polish

ST ® ultra polish E-2000 angled polish LX.5 ® ultra polish (144 only) LX.5 ® angled polish (144 only)

LC ultra polish (144 only)

5

Fiber Termination Blocks (FTB) Unterminated

FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case theadapter packs for the block must be ordered separately (see page 12) Before ordering, determine the blockorientation and cable exit direction Unterminated FTBs may be ordered with a “left” orientation (mounts onthe left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exitdirection will be either “upward” (cables terminated to the rear side of the block exit up toward the top ofthe frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom ofthe frame) All blocks with adapters only are configured to terminate single or dual jumpers on the rear ofthe block If a multifiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, aseparate clamping kit is required (see page 7)

Vertical column of the frame the FTB is to be mounted on

Cable Exit Direction

* 144 blocks using style 1, 2, or 3 cannot be used

in 26" wide NGF frames

Trang 6

Fiber Termination Blocks

Clamping kit includes: Cable clamp, protective cover and fanout bracket It is required when terminating

a multifiber breakout style cable to the rear of the block

72 position block loaded

with jumpers

72 position block loaded with multifiber breakout cable 72 position block with clamping kit

Protective Cover

Fanout BracketCable Clamping Kit

Rear Cable Management Tray for 144 Block Conversion Kit

Block style originally purchased

All 48- and 72-position blocks NGF-ACCOSPKIT02

96- or 144-position Left Up Blocks NGF-ACCRCMSLU

96- or 144-position Right Up Blocks NGF-ACCRCMSRU

96- or 144-position Left Down Blocks NGF-ACCRCMSLD

96- or 144-position Right Down Blocks NGF-ACCRCMSRD

O r d e r i n g I n f o r m a t i o n

Trang 7

Fiber Termination Blocks (FTB) Preterminated

Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or strandedconfigurations All blocks are 100% factory tested to guarantee continuity and reliable connections.Preterminated FTBs make installation quick and easy, reducing labor costs Before ordering, determinethe block orientation and cable exit direction Preterminated FTBs may be ordered with a “left”orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side ofthe frame) The cable exit direction will be either “upward” (cables terminated to the rear side of theblock exit up toward the top of the frame) or “downward” (cables terminated to the rear side of theblock exit down toward the bottom of the frame)

Preterminated Fiber

Termination Blocks

arrive from the factory

with either IFC or

Ordering information follows on next page.

Fiber Termination Block loaded with multifiber breakout cable

Vertical column of the frame the FTB is to be mounted on

4 Cable Exit Direction

Direction the equipment jumpers or OSP cable will exit from the FTB

5 Adapter/Connector #1

Specific adapter/connector type required in the FTB Refers to the adapter/

connector type at the FTB

Trang 8

†Other cable types are available upon request Please contact your ACD representative.

12-fiber stranded24-fiber stranded 36-fiber stranded 48-fiber stranded 72-fiber stranded96-fiber stranded 144-fiber stranded

CorningCorningCorningCorningCorningCorningCorning

Length in meters

SCFC/ST®E-2000LX.5®/LC

Cable Exit Direction

UD

UpwardDownward

Block Configuration

ABCM

487296

144 (LX.5® or

LC only)**

Block Orientation

LR

LeftRight

72-fiber stranded96-fiber stranded144-fiber stranded12-fiber stranded24-fiber stranded36-fiber stranded48-fiber stranded72-fiber stranded96-fiber stranded144-fiber stranded12-fiber ribbon24-fiber ribbon36-fiber ribbon48-fiber ribbon72-fiber ribbon96-fiber ribbon144-fiber ribbon

House Cable*House Cable*House Cable*CorningCorningCorningCorningCorningCorningCorningSumitomoSumitomoSumitomoSumitomoSumitomoSumitomoSumitomo

7

OSP Cable Type Singlemode

72 fiber stranded dielectric96-fiber ribbon dielectric96-fiber stranded dielectric144-fiber stranded dielectric144-fiber ribbon dielectric

VTVWENFLFM

PirelliPirelliPirelliPirelliPirelli

09A5YP

No connector/stub endSC

FC

ST®LX.5® (144 only)

LC (144 only)

Connector #2 Singlemode

078L23Q4VNXK

LC ultra polish (144 only)

Connector #2 Multimode (62.5/125)

OR

6

OR

Adapter/Connector #1 Multimode (62.5/125)

9A5YP

SCFC

ST®LX.5® (144 only)

LC (144 only)

Adapter Type Singlemode

78L23Q4VNXK

SC ultra polish

SC ultra polish, zirconia sleeve

SC 8° angled polish

FC ultra polish

FC ultra polish,zirconia sleeve

FC 8° angled polish

ST® ultra polishE-2000 angled polishLX.5® ultra polish(144 only)LX.5® angled polish(144 only)

LC ultra polish (144 only)

5 Preterminated FTBs

See previous page for definition of variables.

*House cable will use Corning SMF28, Sumitomo, Alcatel or similar singlemode fiber based on current market availability.

** 144 blocks using style 1, 2, or 3 cannot

be used in 26" wide NGF frames

Trang 9

Fiber Combination Blocks (FCB)

Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame Theblocks are available with several different adapter types in block configurations of 48-, 72-, or 96-positions.Also, a 144-position FCB is available using an LX.5®or LC adapter The termination portion of the fibercombination block utilizes sliding adapter packs to gain easy access to connectors on both the front andrear side of the block The block is available with factory-installed pigtails for easy installation Splice traysare shipped with the block if ordered with pigtails; otherwise trays must be ordered separately The block isshipped with a cable clamp for OSP/IFC The FCB occupies two mounting positions on a frame section.Before ordering, determine the block orientation FCBs may be ordered with a “left” orientation (mounts

on the left side of the frame) or a “right” orientation (mounts on the right side of the frame)

Ordering information follows on next page.

Type of pigtail required

Number of Pigtail Assemblies

Number of pigtails to be pre-installed in the FCB

Splice Chip

Type of splice chip required for splice trays

Trang 10

Empty Bare fusion Heat shrink fusion Mechanical (Elastomeric) Nortel QPAK

Swiss ® ANT Rotary FibrLok ®

16 position heat shrink fusion

Block Style

1 2 3 4

SC FC/ST ®

E-2000 LX.5 ® /LC

Block Configuration

A B C M

48 72 96

144 (LX.5 ® or LC only)

1

2

Number of Pigtail Assemblies

XX Number of assemblies

6

Pigtail Type

0 1 2 4 5

No pigtails 12-fiber pigtail 12-fiber stranded Maxi-Strip 8-fiber pigtail 12-fiber ribbon

5

7

Block Orientation

L R

Left Right

3

A 5 9 Y P

FC

ST ®

SC LX.5 ® (144 only)

LC (144 only)

4

OR

Adapter/Connector Type Multimode (62.5/125)

Adapter Type Singlemode

7 8 L 2 3 Q 4 V N X K

SC ultra polish

SC ultra polish, zirconia sleeve

SC 8 ° angled polish

FC ultra polish

FC ultra polish, zirconia sleeve

FC 8 ° angled polish

ST ® ultra polish E-2000 angled polish LX.5 ® ultra polish (144 only) LX.5 ® angled polish (144 only)

LC ultra polish (144 only)

4

1Fiber Combination Blocks (FCB)

1 144-termination block requires the use of either:

Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing

Nortel QPAK splice tray when using single fiber heat shrink fusion splicing

144 blocks using block style 1, 2, or 3 cannot be used in 26" wide NGF frames

Splice Trays For Fiber Combination Block

Catalog Number FST - DRS

Splice Tray Type

00FTHSMTNTANTRT3M

Empty tray*

Bare fusionHeat shrink fusionMechanical (elastomeric)Nortel QPAK

Swiss ANTRotaryFibrLok®

* Maximum size of chip allowed in empty tray: 3"H x 2.5"W x 3.6"L

Note: For LX.5® FCB with 12 fiber ribbon

pigtails, select mechanical splicing only.

For LX.5® FCB with 12 fiber stranded pigtails

select Nortel QPAK (compatible with heat

shrink fusion), bare fusion or Swiss ANT only.

Number of Splices

1224

Trang 11

144-Position (block code'E')

144-Position (block code'M')

J (not shown below)

H (not shown below)

K (not shown below)

Sliding Adapter Packs

Sliding adapter packs house groups of fiber optic adapters and are mounted in Fiber Termination Blocks toprovide easy access to connectors Sliding adapter packs are available with SC, FC, ST®, E-2000, LX.5®and

LC adapters The adapters come in packs of two, four, six and eight depending on the adapter type andthe desired termination density See table below for configuration guidelines

Sliding Adapter Pack Configuration Guidelines Block

Adapter Pack Configuration

Adapter Pack Option

Option A

(SC shown)

Option B (FC shown)

Option E (ST ® shown)

Option F (E-2000 shown)

Option G (FC shown)

Option H (LX.5 ® only)

Catalog Number NGF- SAP

Adapter Pack Option*

ABEFGHJK

4 pack / 4 pack

6 pack / 6 pack(all block code "M" blocks)

0

Adapter Type Multimode

9A5Y

SC FC

ST®LX.5® (144 only)

OR

Adapter Type

Singlemode

78L23Q4VNX

5

Trang 12

Value-Added Module System Chassis

The NGF VAM chassis is designed to mount

on all standard NGF frame styles and is

interchangeable with termination, splice, and

storage modules Each chassis accommodates

up to twelve Mini-VAM modules

NGF - TB D

Block Orientation

LR

LeftRight

Cable Exit Direction (Rear)

UD

UpwardDownward

NGF VAM Chassis

* NGF VAMs with LX.5 ® or LC adapters can be placed in any of these block styles

Please contact ADC Technical Assistance Center with any questions.

VAM Chassis

Ordering of information for value-added modules starts on page 54.

Features:

Enclosed plug-in modules

Optical components are protected from physical and environmental damage

Flexible platform

Modules can be created for new applications quickly and easily to meet customer requirements

Monitor and/or test

Enables providers to troubleshoot networks without forcing disruption of service

Custom configurations

Custom splitter configurations available upon request

ADC’s Next Generation Frame (NGF) Value-AddedModules are designed to support emerging circuitrequirements This high-density fiber frame solutionprovides unlimited expansion while optimizing fibercable management The NGF system uses Mini Value-Added Modules to incorporate optical splitters for circuitmonitoring and video distribution Mini Value-AddedModules can also be configured with wavelengthdivision multiplexing capabilities to increase transmissioncapacity over existing fiber lines Various input andoutput interface options are available

Trang 13

O r d e r i n g I n f o r m a t i o n

Description

FOT storage bay for 600 mm

FMDF lineups

FOT storage bay for 600 mm

F3MDF lineups (not shown)

Trang 14

The NGF Equipment Bay provides a mounting

location for 19-inch rack mount equipment within an

FMDF lineup The equipment deployment in the bay

can include video transmitters, RF Splitter/Combiners,

or Remote Fiber Test Systems NGF Equipment Bays

are available for FMDF lineups (600 mm deep) and

(maximum equipment width)

(36) rack unit mounting spaces

available (EIA hole spacing)

Equipment bay for F3MDF lineups

For 19" (48.26 cm) equipment

(maximum equipment width)

(36) rack unit mounting spaces

available (EIA hole spacing)