Trang 1Fiber Termination Blocks (FTB)
Fiber Termination Blocks (FTBs) are available with SC, FC, ST®and E-2000 adapters in block configurations
of 48, 72 or 96 positions Also, 144 position FTBs are available using LX.5®and LC adapters FTBs utilizesliding adapter packs to gain easy access to both the front and rear connectors There is also a blockconfiguration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiringsplitters or WDMs FTBs can be ordered with or without IFC or outside plant cable
Fiber Combination Blocks Blocks (FCB)
Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block.The block occupies two mounting positions on the frame section They are available with SC, FC, ST®andE-2000 adapters in block configurations of 48, 72 or 96 positions Also, 144 position FCBs are availableusing LX.5®or LC adapters
Features and Benefits
Ample Trough Space
Reduces jumper pile-up and congestion
- Reduces maintenance time due to easy removal and tracing of jumpers
- Minimizes risk of microbends or damage
to fiber
Built-in Jumper Storage Panel
Minimizes number of required jumper lengths
Maintains fiber bend radius
Simplifies frame installation
- Saves money by reducing the number of
different jumper lengths that have to be kept
in inventory
- Minimizes risk of microbends or damage
to fiber
Sliding Adapter Packs
Promotes high density Provides easy access to connectors
- Saves valuable floor space
- Reduces time required for operations and maintenance
Intelligent Cable Routing System
No fiber cross-over points Multiple vertical troughways
- Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber “weaving”
Trang 210/03 • 100571
Fiber Main Distributing Frame (FMDF)
The FMDF is the cornerstone of the NGF product line This innovative frame has six rear horizontal troughs.This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability andremoval The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided betweenvertical columns on the left and right sides of the frame as shown in the figure below The frame is 600 mmwide x 600 mm deep The built-in jumper storage panel will store up to 5 meters of jumper slack
Right Vertical
Left
Trough (6) Jumper
Storage Panel
Trang 3Front Facing Fiber Main Distributing Frame (F3MDF)
The F3MDF is designed for single-sided access applications and may be mounted up against a wall or to-back to save floor space Unlike the FMDF, the more compact F3MDF is equipped with a single 230 mmhorizontal trough The F3MDF has twelve FTB mounting positions equally divided between vertical columns
back-on the left and right sides of the frame as shown in the figure below The frame is 600 mm wide x 480 mmdeep The built-in jumper storage panel will store up to 5 meters of jumper slack
2.2 m
Jumper Storage Panel
Right Vertical
Left Vertical
FTB Mounting Position (12)
Horizontal Trough (6)
Trang 4Fiber Slim Rack
The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF It has six FTBmounting positions and is designed for single-sided access applications The Slim Rack is intended foruse in a single frame application and should not be used in a multiframe lineup The built-in jumperstorage panel will store up to 5 meters of jumper slack
When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used
Trang 5Block Style
1 2 3 4
1
3
SC FC/ST ®
E-2000 LX.5 ® /LC
Cable Exit Direction
U D
Upward Downward
Block Configuration
A B C M
48 72 96
144 (LX.5 ® or LC only)*
Block Orientation
L R
Left Right
Adapter Type (62.5/125) Multimode
9 A 5 Y P
SC FC
ST ®
LX.5 ®
(144 only)
LC (144 only)
OR
Adapter Type Singlemode
7 8 L 2 3 Q 4 V N X K
SC ultra polish
SC ultra polish, zirconia sleeve
SC 8 ° angled polish
FC ultra polish
FC ultra polish, zirconia sleeve
FC 8 ° angled polish
ST ® ultra polish E-2000 angled polish LX.5 ® ultra polish (144 only) LX.5 ® angled polish (144 only)
LC ultra polish (144 only)
5
Fiber Termination Blocks (FTB) Unterminated
FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case theadapter packs for the block must be ordered separately (see page 12) Before ordering, determine the blockorientation and cable exit direction Unterminated FTBs may be ordered with a “left” orientation (mounts onthe left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exitdirection will be either “upward” (cables terminated to the rear side of the block exit up toward the top ofthe frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom ofthe frame) All blocks with adapters only are configured to terminate single or dual jumpers on the rear ofthe block If a multifiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, aseparate clamping kit is required (see page 7)
Vertical column of the frame the FTB is to be mounted on
Cable Exit Direction
* 144 blocks using style 1, 2, or 3 cannot be used
in 26" wide NGF frames
Trang 6Fiber Termination Blocks
Clamping kit includes: Cable clamp, protective cover and fanout bracket It is required when terminating
a multifiber breakout style cable to the rear of the block
72 position block loaded
with jumpers
72 position block loaded with multifiber breakout cable 72 position block with clamping kit
Protective Cover
Fanout BracketCable Clamping Kit
Rear Cable Management Tray for 144 Block Conversion Kit
Block style originally purchased
All 48- and 72-position blocks NGF-ACCOSPKIT02
96- or 144-position Left Up Blocks NGF-ACCRCMSLU
96- or 144-position Right Up Blocks NGF-ACCRCMSRU
96- or 144-position Left Down Blocks NGF-ACCRCMSLD
96- or 144-position Right Down Blocks NGF-ACCRCMSRD
O r d e r i n g I n f o r m a t i o n
Trang 7Fiber Termination Blocks (FTB) Preterminated
Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or strandedconfigurations All blocks are 100% factory tested to guarantee continuity and reliable connections.Preterminated FTBs make installation quick and easy, reducing labor costs Before ordering, determinethe block orientation and cable exit direction Preterminated FTBs may be ordered with a “left”orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side ofthe frame) The cable exit direction will be either “upward” (cables terminated to the rear side of theblock exit up toward the top of the frame) or “downward” (cables terminated to the rear side of theblock exit down toward the bottom of the frame)
Preterminated Fiber
Termination Blocks
arrive from the factory
with either IFC or
Ordering information follows on next page.
Fiber Termination Block loaded with multifiber breakout cable
Vertical column of the frame the FTB is to be mounted on
4 Cable Exit Direction
Direction the equipment jumpers or OSP cable will exit from the FTB
5 Adapter/Connector #1
Specific adapter/connector type required in the FTB Refers to the adapter/
connector type at the FTB
Trang 8†Other cable types are available upon request Please contact your ACD representative.
12-fiber stranded24-fiber stranded 36-fiber stranded 48-fiber stranded 72-fiber stranded96-fiber stranded 144-fiber stranded
CorningCorningCorningCorningCorningCorningCorning
Length in meters
SCFC/ST®E-2000LX.5®/LC
Cable Exit Direction
UD
UpwardDownward
Block Configuration
ABCM
487296
144 (LX.5® or
LC only)**
Block Orientation
LR
LeftRight
72-fiber stranded96-fiber stranded144-fiber stranded12-fiber stranded24-fiber stranded36-fiber stranded48-fiber stranded72-fiber stranded96-fiber stranded144-fiber stranded12-fiber ribbon24-fiber ribbon36-fiber ribbon48-fiber ribbon72-fiber ribbon96-fiber ribbon144-fiber ribbon
House Cable*House Cable*House Cable*CorningCorningCorningCorningCorningCorningCorningSumitomoSumitomoSumitomoSumitomoSumitomoSumitomoSumitomo
7
OSP Cable Type Singlemode
72 fiber stranded dielectric96-fiber ribbon dielectric96-fiber stranded dielectric144-fiber stranded dielectric144-fiber ribbon dielectric
VTVWENFLFM
PirelliPirelliPirelliPirelliPirelli
09A5YP
No connector/stub endSC
FC
ST®LX.5® (144 only)
LC (144 only)
Connector #2 Singlemode
078L23Q4VNXK
LC ultra polish (144 only)
Connector #2 Multimode (62.5/125)
OR
6
OR
Adapter/Connector #1 Multimode (62.5/125)
9A5YP
SCFC
ST®LX.5® (144 only)
LC (144 only)
Adapter Type Singlemode
78L23Q4VNXK
SC ultra polish
SC ultra polish, zirconia sleeve
SC 8° angled polish
FC ultra polish
FC ultra polish,zirconia sleeve
FC 8° angled polish
ST® ultra polishE-2000 angled polishLX.5® ultra polish(144 only)LX.5® angled polish(144 only)
LC ultra polish (144 only)
5 Preterminated FTBs
See previous page for definition of variables.
*House cable will use Corning SMF28, Sumitomo, Alcatel or similar singlemode fiber based on current market availability.
** 144 blocks using style 1, 2, or 3 cannot
be used in 26" wide NGF frames
Trang 9Fiber Combination Blocks (FCB)
Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame Theblocks are available with several different adapter types in block configurations of 48-, 72-, or 96-positions.Also, a 144-position FCB is available using an LX.5®or LC adapter The termination portion of the fibercombination block utilizes sliding adapter packs to gain easy access to connectors on both the front andrear side of the block The block is available with factory-installed pigtails for easy installation Splice traysare shipped with the block if ordered with pigtails; otherwise trays must be ordered separately The block isshipped with a cable clamp for OSP/IFC The FCB occupies two mounting positions on a frame section.Before ordering, determine the block orientation FCBs may be ordered with a “left” orientation (mounts
on the left side of the frame) or a “right” orientation (mounts on the right side of the frame)
Ordering information follows on next page.
Type of pigtail required
Number of Pigtail Assemblies
Number of pigtails to be pre-installed in the FCB
Splice Chip
Type of splice chip required for splice trays
Trang 10Empty Bare fusion Heat shrink fusion Mechanical (Elastomeric) Nortel QPAK
Swiss ® ANT Rotary FibrLok ®
16 position heat shrink fusion
Block Style
1 2 3 4
SC FC/ST ®
E-2000 LX.5 ® /LC
Block Configuration
A B C M
48 72 96
144 (LX.5 ® or LC only)
1
2
Number of Pigtail Assemblies
XX Number of assemblies
6
Pigtail Type
0 1 2 4 5
No pigtails 12-fiber pigtail 12-fiber stranded Maxi-Strip 8-fiber pigtail 12-fiber ribbon
5
7
Block Orientation
L R
Left Right
3
A 5 9 Y P
FC
ST ®
SC LX.5 ® (144 only)
LC (144 only)
4
OR
Adapter/Connector Type Multimode (62.5/125)
Adapter Type Singlemode
7 8 L 2 3 Q 4 V N X K
SC ultra polish
SC ultra polish, zirconia sleeve
SC 8 ° angled polish
FC ultra polish
FC ultra polish, zirconia sleeve
FC 8 ° angled polish
ST ® ultra polish E-2000 angled polish LX.5 ® ultra polish (144 only) LX.5 ® angled polish (144 only)
LC ultra polish (144 only)
4
1Fiber Combination Blocks (FCB)
1 144-termination block requires the use of either:
Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing
Nortel QPAK splice tray when using single fiber heat shrink fusion splicing
144 blocks using block style 1, 2, or 3 cannot be used in 26" wide NGF frames
Splice Trays For Fiber Combination Block
Catalog Number FST - DRS
Splice Tray Type
00FTHSMTNTANTRT3M
Empty tray*
Bare fusionHeat shrink fusionMechanical (elastomeric)Nortel QPAK
Swiss ANTRotaryFibrLok®
* Maximum size of chip allowed in empty tray: 3"H x 2.5"W x 3.6"L
Note: For LX.5® FCB with 12 fiber ribbon
pigtails, select mechanical splicing only.
For LX.5® FCB with 12 fiber stranded pigtails
select Nortel QPAK (compatible with heat
shrink fusion), bare fusion or Swiss ANT only.
Number of Splices
1224
Trang 11144-Position (block code'E')
144-Position (block code'M')
J (not shown below)
H (not shown below)
K (not shown below)
Sliding Adapter Packs
Sliding adapter packs house groups of fiber optic adapters and are mounted in Fiber Termination Blocks toprovide easy access to connectors Sliding adapter packs are available with SC, FC, ST®, E-2000, LX.5®and
LC adapters The adapters come in packs of two, four, six and eight depending on the adapter type andthe desired termination density See table below for configuration guidelines
Sliding Adapter Pack Configuration Guidelines Block
Adapter Pack Configuration
Adapter Pack Option
Option A
(SC shown)
Option B (FC shown)
Option E (ST ® shown)
Option F (E-2000 shown)
Option G (FC shown)
Option H (LX.5 ® only)
Catalog Number NGF- SAP
Adapter Pack Option*
ABEFGHJK
4 pack / 4 pack
6 pack / 6 pack(all block code "M" blocks)
0
Adapter Type Multimode
9A5Y
SC FC
ST®LX.5® (144 only)
OR
Adapter Type
Singlemode
78L23Q4VNX
5
Trang 12Value-Added Module System Chassis
The NGF VAM chassis is designed to mount
on all standard NGF frame styles and is
interchangeable with termination, splice, and
storage modules Each chassis accommodates
up to twelve Mini-VAM modules
NGF - TB D
Block Orientation
LR
LeftRight
Cable Exit Direction (Rear)
UD
UpwardDownward
NGF VAM Chassis
* NGF VAMs with LX.5 ® or LC adapters can be placed in any of these block styles
Please contact ADC Technical Assistance Center with any questions.
VAM Chassis
Ordering of information for value-added modules starts on page 54.
Features:
• Enclosed plug-in modules
Optical components are protected from physical and environmental damage
• Flexible platform
Modules can be created for new applications quickly and easily to meet customer requirements
• Monitor and/or test
Enables providers to troubleshoot networks without forcing disruption of service
• Custom configurations
Custom splitter configurations available upon request
ADC’s Next Generation Frame (NGF) Value-AddedModules are designed to support emerging circuitrequirements This high-density fiber frame solutionprovides unlimited expansion while optimizing fibercable management The NGF system uses Mini Value-Added Modules to incorporate optical splitters for circuitmonitoring and video distribution Mini Value-AddedModules can also be configured with wavelengthdivision multiplexing capabilities to increase transmissioncapacity over existing fiber lines Various input andoutput interface options are available
Trang 13O r d e r i n g I n f o r m a t i o n
Description
FOT storage bay for 600 mm
FMDF lineups
FOT storage bay for 600 mm
F3MDF lineups (not shown)
Trang 14The NGF Equipment Bay provides a mounting
location for 19-inch rack mount equipment within an
FMDF lineup The equipment deployment in the bay
can include video transmitters, RF Splitter/Combiners,
or Remote Fiber Test Systems NGF Equipment Bays
are available for FMDF lineups (600 mm deep) and
(maximum equipment width)
(36) rack unit mounting spaces
available (EIA hole spacing)
Equipment bay for F3MDF lineups
For 19" (48.26 cm) equipment
(maximum equipment width)
(36) rack unit mounting spaces
available (EIA hole spacing)