The frame has twelve Fiber Termination Block FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below.. Catal

Trang 1

600 mm Product Family

Ordering Guide

Trang 2

6/03 • 852

Table of Contents

Introduction 1

Frames Fiber Main Distributing Frame (FMDF) 2

Front Facing Fiber Main Distributing Frame (F3MDF) 3

Fiber Slim Rack 4

Blocks Fiber Termination Blocks (FTB) Unterminated 5

Cable Clamping Kit 6

Fiber Termination Blocks Preterminated 7-8 Fiber Combination Blocks (FCB) 9-11 Sliding Adapter Packs 12

Mini Value-Added Modules (Mini VAMs) .13-21 Accessories Fiber Optic Terminal Jumper Storage Bay 22

Equipment Bay 23

End Guard 24

Cable Clamp Kits 24

Rack Installation Kits 24

AC Outlet Kits 24

Ultra Physical Contact Fiber Optic Patch Cords 25-26 Index 27

Trang 3

deployment of SONET/SDH, fiber in the loop and video initiatives has created the demand for increased termination density at the fiber distributing frame Service providers must build a sound network

infrastructure that will provide a solid base for delivering the new and enhanced broadband services promised by the ever-advancing information superhighway.

What's Next?

It's clear that simply adding additional fiber frames to an existing FDF lineup is not the answer, as

conventional fiber frames allow only a small number of bays in a lineup before the horizontal trough system becomes unmanageable A more innovative fiber management plan is needed that will provide unlimited expansion as well as alleviate jumper pile-up in the horizontal troughs.

With the introduction of its Next Generation Frame family of products, ADC offers the innovative solution that service providers have been waiting for Designed specifically to provide higher density while improving fiber cable management, the Next Generation Frame product family allows for virtually unlimited growth.

Frames

ADC's Next Generation Frame product line has fiber frames designed to fit a variety of termination, splice, and storage applications Each frame option is designed with an emphasis on superior cable management and ease of use, including features such as ample trough space for cable and jumpers, easy access to connectors, and storage for jumpers The frame sections are shipped from the factory fully equipped with all cable management hardware including a built-in jumper storage panel.

Fiber Termination Blocks (FTB)

Fiber Termination Blocks (FTBs) are available with SC, FC, ST®and E-2000 adapters in block configurations

of 48, 72 or 96 positions Also, 144 position FTBs are available using LX.5® and LC adapters FTBs utilize sliding adapter packs to gain easy access to both the front and rear connectors There is also a block configuration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiring splitters or WDMs FTBs can be ordered with or without IFC or outside plant cable.

Fiber Combination Blocks Blocks (FCB)

Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block The block occupies two mounting positions on the frame section They are available with SC, FC, ST®and E-2000 adapters in block configurations of 48, 72 or 96 positions Also, 144 position FCBs are available using LX.5®or LC adapters.

Features and Benefits

Ample Trough Space

Reduces jumper pile-up and congestion

- Reduces maintenance time due to easy removal and tracing of jumpers

- Minimizes risk of microbends or damage to fiber

Built-in Jumper Storage Panel

Minimizes number of required jumper lengths

Maintains fiber bend radius

Simplifies frame installation

- Saves money by reducing the number of different jumper lengths that have to be kept in inventory

- Minimizes risk of microbends or damage to fiber

Sliding Adapter Packs

Promotes high densityProvides easy access to connectors

- Saves valuable floor space

- Reduces time required for operations and maintenance

Intelligent Cable Routing System

No fiber cross-over pointsMultiple vertical troughways

- Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber “weaving”

Trang 4

6/03 • 852

Fiber Main Distributing Frame (FMDF)

The FMDF is the cornerstone of the NGF product line This innovative frame has six rear horizontal troughs This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability and removal The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below The frame is 600 mm wide x 600 mm deep The built-in jumper storage panel will store up to 5 meters

Right Vertical Left

Vertical

Horizontal Trough (6) Jumper

Storage Panel

Trang 5

Front Facing Fiber Main Distributing Frame (F3MDF)

The F3MDF is designed for single-sided access applications and may be mounted up against a wall or back-to-back to save floor space Unlike the FMDF, the more compact F3MDF is equipped with a single

230 mm horizontal trough The F3MDF has twelve FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below The frame is

600 mm wide x 480 mm deep The built-in jumper storage panel will store up to 5 meters of

jumper slack.

2.2 m

Jumper Storage Panel

Right Vertical Left

Vertical

FTB Mounting Position (12)

Horizontal Trough (6)

Trang 6

2.14 m

FTB Mounting Position

Jumper Storage Panel

Fiber Slim Rack

The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF It has six FTB mounting positions and is designed for single-sided access applications The Slim Rack is intended for use in a single frame application and should not be used in a multiframe lineup The built-in jumper storage panel will store up to 5 meters of jumper slack.

When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used on this frame.

NGF Fiber Slim Rack Frame Section

Trang 7

Catalog Number NGF-TB

Block Style

12341

3

SCFC/ST®E-2000LX.5®/LC

Cable Exit Direction

UD

UpwardDownward

Block Configuration

ABCM

487296

144 (LX.5® or LC only)*

Block Orientation

LR

LeftRight

Adapter Type (62.5/125) Multimode

9A5YP

SC FC

ST®LX.5® (144 only)

LC (144 only)

OR

Adapter Type Singlemode

78L23Q4VNXK

SC ultra polish

SC ultra polish, zirconia sleeve

SC 8° angled polish

FC ultra polish

FC ultra polish,zirconia sleeve

FC 8° angled polish

ST® ultra polishE-2000 angled polishLX.5® ultra polish(144 only)LX.5® angled polish(144 only)

LC ultra polish (144 only)5

Fiber Termination Blocks (FTB) Unterminated

FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case the adapter packs for the block must be ordered separately (see page 12) Before ordering, determine the block orientation and cable exit direction Unterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame) All blocks with adapters only are configured to terminate single or dual jumpers on the rear of the block If a multi-fiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, a separate clamping kit is required (see page 6).

Vertical column of the frame the FTB is to be mounted on

Cable Exit Direction

Direction the equipment jumpers or OSP cable will exit from the FTB

Adapter Type

Specific adapter type required in the FTB

* 144 blocks using style 1, 2, or 3 cannot be used

in 26" wide NGF frames

Trang 8

Fiber Termination Blocks

Clamping kit includes: Cable clamp, protective cover and fanout bracket It is required when terminating

a multifiber breakout style cable to the rear of the block.

72 position block loaded

with jumpers

72 position block loaded withmultifiber breakout cable 72 position block with clamping kit

Protective Cover

Fanout BracketCable Clamping Kit

Rear Cable Management Tray for 144 Block Conversion Kit

Block style originally purchased

96-position blocks with rear cable management NGF-ACCOSPKIT01

as shown above (blocks ordered before June 2002

96- or 144-position Left Up Blocks NGF-ACCRCMSLU

96- or 144-position Right Up Blocks NGF-ACCRCMSRU

96- or 144-position Left Down Blocks NGF-ACCRCMSLD

96- or 144-position Right Down Blocks NGF-ACCRCMSRD

O r d e r i n g I n f o r m a t i o n

Trang 9

Fiber Termination Blocks (FTB) Preterminated

Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or stranded configurations All blocks are 100% factory tested to guarantee continuity and reliable connections Preterminated FTBs make installation quick and easy, reducing labor costs Before ordering, determine the block orientation and cable exit direction Preterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame).

Preterminated Fiber

Termination Blocks

arrive from the factory

with either IFC or

Ordering information follows on next page.

Fiber Termination Blockloaded with multifiberbreakout cable

Vertical column of the frame the FTB is to be mounted on

4 Cable Exit Direction

Direction the equipment jumpers or OSP cable will exit from the FTB

5 Adapter/Connector #1

Specific adapter/connector type required in the FTB Refers to the adapter/

connector type at the FTB

Trang 10

†Other cable types are available upon request Please contact your ACD representative.

Length in meters

SCFC/ST®

E-2000LX.5®/LC

Cable Exit Direction

UD

UpwardDownward

Block Configuration

ABCM

487296

144 (LX.5® or

LC only)**

Block Orientation

LR

LeftRight

7

OSP Cable Type Singlemode

72 fiber ribbon dielectric

72 fiber stranded dielectric

96 fiber ribbon dielectric

96 fiber ribbon dielectric

96 fiber stranded dielectric

144 fiber stranded dielectric

144 fiber ribbon dielectric

VPVTVUVWENFLFM

AlcatelPirelliAlcatelPirelliPirelliPirelliPirelli

09A5YP

No connector/stub endSC

LC ultra polish (144 only)

Connector #2 Multimode (62.5/125)

OR

6

OR

Adapter/Connector #1 Multimode (62.5/125)

9A5YP

SCFC

ST®

LX.5® (144 only)

LC (144 only)

Adapter Type Singlemode

78L23Q4VNXK

SC ultra polish

SC ultra polish, zirconia sleeve

SC 8° angled polish

FC ultra polish

FC ultra polish,zirconia sleeve

FC 8° angled polish

ST® ultra polishE-2000 angled polishLX.5® ultra polish(144 only)LX.5® angled polish(144 only)

LC ultra polish (144 only)

5 Preterminated FTBs

See previous page for definition of variables.

* House cable will use Corning SMF28, Sumitomo, Alcatel or similar singlemode fiber based on current market availability

** 144 blocks using style 1, 2, or 3 cannot be used

in 26" wide NGF frames

Trang 11

Fiber Combination Blocks (FCB)

Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame The blocks are available with several different adapter types in block configurations of 48, 72, or 96 positions Also, a 144 position FCB is available using an LX.5®adapter The termination portion of the fiber combination block utilizes sliding adapter packs to gain easy access to connectors on both the front and rear side of the block The block is available with factory-installed pigtails for easy installation Splice trays are shipped with the block if ordered with pigtails; otherwise trays must be ordered separately The block is shipped with a cable clamp for OSP/IFC The FCB occupies two mounting positions on a frame section Before ordering, determine the block orientation FCBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame).

Ordering information follows on next page.

Trang 12

EmptyBare fusionHeat shrink fusionMechanical (elastomeric)Nortel QPAK

Swiss® ANTRotaryFibrLok®

16 position heat shrink fusion

E-2000LX.5® /LC

144 (LX.5® or LC only)

1

2

Number of Pigtail Assemblies

XX Number of assemblies

6

Pigtail Type

01245

No pigtails

12 fiber pigtail

12 fiber strandedMaxi-Strip

3

A59YP

FC

ST®

SCLX.5® (144 only)

LC (144 only)

4

OR

Adapter/Connector Type Multimode (62.5/125)

Adapter Type Singlemode

78L23Q4VNXK

SC ultra polish

SC ultra polish, zirconia sleeve

SC 8° angled polish

FC ultra polish

FC ultra polish,zirconia sleeve

FC 8° angled polish

ST® ultra polishE-2000 angled polishLX.5® ultra polish (144 only)LX.5® angled polish(144 only)

LC ultra polish (144 only)

4

1Fiber Combination Blocks (FCB)

Type of pigtail required

Number of Pigtail Assemblies

Number of pigtails to be pre-installed in the FCB

Splice Chip

Type of splice chip required for splice trays

1144 termination block requires the use of either:

Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing

Nortel QPAK splice tray when using single fiber heat shrink fusion splicing

144 blocks using block style 1, 2, or 3 cannot be used in 26" wide NGF frames

Trang 13

Empty tray*

Bare fusionHeat shrink fusionMechanical (elastomeric)Nortel QPAK

Swiss ANTRotaryFibrLok®

* Maximum size of chip allowed in empty tray: 3"H x 2.5"W x 3.6"L

Note: For LX.5® FCB with 12 fiber ribbon

pigtails, select mechanical splicing only.

For LX.5® FCB with 12 fiber stranded pigtails select Nortel QPAK (compatible with heat

shrink fusion), bare fusion or Swiss ANT only.

Number of Splices

1224

Trang 14

144-Position (block code'E')

144-Position (block code'M')

J (not shown below)

H (not shown below)

K (not shown below)

Sliding Adapter Packs

Sliding adapter packs house groups of fiber optic adapters and are mounted in Fiber Termination Blocks to provide easy access to connectors Sliding Adapter Packs are available with SC, FC, ST®, E-2000 and LX.5®

adapters The adapters come in packs of two, four, six and eight depending on the adapter type and the desired termination density See table below for configuration guidelines.

* Sliding Adapter Pack Configuration GuidelinesBlock

Adapter Pack Configuration

Adapter Pack Option

Option A

(SC shown)

Option B(FC shown)

Option E(ST®shown)

Option F(E-2000 shown)

Option G(FC shown)

Option H(LX.5®only)

Catalog Number NGF- SAP

Adapter Pack Option*

ABEFGH

JK

4 pack / 4 pack

6 pack / 6 pack(all block code "M" blocks)

0

Adapter Type Multimode

9A5Y

SC FC

LC ultra polish (144 only)

5

Trang 15

Value-Added Module System

ADC’s Next Generation Frame (NGF) Value-Added

Modules are designed to support emerging circuit

requirements This high-density fiber frame

solution provides unlimited expansion while

optimizing fiber cable management The NGF

system uses Mini Value-Added Modules to

incorporate optical splitters for circuit monitoring

and video distribution Mini Value-Added Modules

can also be configured with wavelength division

multiplexing capabilities to increase transmission

capacity over existing fiber lines Various input

and output interface options are available.

Features:

Enclosed plug-in modules

Optical components are protected fromphysical and environmental damage

Flexible platform

Modules can be created for new applicationsquickly and easily to meet customerrequirements

Monitor and/or test

Enables providers to troubleshoot networkswithout forcing disruption of service

Custom configurations

Custom splitter configurations available upon request

The NGF VAM chassis is designed to mount

on all standard NGF frame styles and is

interchangeable with termination, splice, and

storage modules Each chassis accommodates

up to twelve Mini-VAM modules.

NGF - TB D

Block Orientation

LR

LeftRight

Cable Exit Direction (Rear)

UD

UpwardDownward

NGF VAM Chassis

* NGF VAMs with LX.5®or LC adapters can be placed in any of these block styles

Please contact ADC Technical Assistance Center at 1-800-366-3891 with any questions

VAM Chassis