The frame has twelve Fiber Termination Block FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below.. Catal
Trang 1600 mm Product Family
Ordering Guide
Trang 26/03 • 852
Table of Contents
Introduction 1
Frames Fiber Main Distributing Frame (FMDF) 2
Front Facing Fiber Main Distributing Frame (F3MDF) 3
Fiber Slim Rack 4
Blocks Fiber Termination Blocks (FTB) Unterminated 5
Cable Clamping Kit 6
Fiber Termination Blocks Preterminated 7-8 Fiber Combination Blocks (FCB) 9-11 Sliding Adapter Packs 12
Mini Value-Added Modules (Mini VAMs) .13-21 Accessories Fiber Optic Terminal Jumper Storage Bay 22
Equipment Bay 23
End Guard 24
Cable Clamp Kits 24
Rack Installation Kits 24
AC Outlet Kits 24
Ultra Physical Contact Fiber Optic Patch Cords 25-26 Index 27
Trang 3deployment of SONET/SDH, fiber in the loop and video initiatives has created the demand for increased termination density at the fiber distributing frame Service providers must build a sound network
infrastructure that will provide a solid base for delivering the new and enhanced broadband services promised by the ever-advancing information superhighway.
What's Next?
It's clear that simply adding additional fiber frames to an existing FDF lineup is not the answer, as
conventional fiber frames allow only a small number of bays in a lineup before the horizontal trough system becomes unmanageable A more innovative fiber management plan is needed that will provide unlimited expansion as well as alleviate jumper pile-up in the horizontal troughs.
With the introduction of its Next Generation Frame family of products, ADC offers the innovative solution that service providers have been waiting for Designed specifically to provide higher density while improving fiber cable management, the Next Generation Frame product family allows for virtually unlimited growth.
Frames
ADC's Next Generation Frame product line has fiber frames designed to fit a variety of termination, splice, and storage applications Each frame option is designed with an emphasis on superior cable management and ease of use, including features such as ample trough space for cable and jumpers, easy access to connectors, and storage for jumpers The frame sections are shipped from the factory fully equipped with all cable management hardware including a built-in jumper storage panel.
Fiber Termination Blocks (FTB)
Fiber Termination Blocks (FTBs) are available with SC, FC, ST®and E-2000 adapters in block configurations
of 48, 72 or 96 positions Also, 144 position FTBs are available using LX.5® and LC adapters FTBs utilize sliding adapter packs to gain easy access to both the front and rear connectors There is also a block configuration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiring splitters or WDMs FTBs can be ordered with or without IFC or outside plant cable.
Fiber Combination Blocks Blocks (FCB)
Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block The block occupies two mounting positions on the frame section They are available with SC, FC, ST®and E-2000 adapters in block configurations of 48, 72 or 96 positions Also, 144 position FCBs are available using LX.5®or LC adapters.
Features and Benefits
Ample Trough Space
Reduces jumper pile-up and congestion
- Reduces maintenance time due to easy removal and tracing of jumpers
- Minimizes risk of microbends or damage to fiber
Built-in Jumper Storage Panel
Minimizes number of required jumper lengths
Maintains fiber bend radius
Simplifies frame installation
- Saves money by reducing the number of different jumper lengths that have to be kept in inventory
- Minimizes risk of microbends or damage to fiber
Sliding Adapter Packs
Promotes high densityProvides easy access to connectors
- Saves valuable floor space
- Reduces time required for operations and maintenance
Intelligent Cable Routing System
No fiber cross-over pointsMultiple vertical troughways
- Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber “weaving”
Trang 46/03 • 852
Fiber Main Distributing Frame (FMDF)
The FMDF is the cornerstone of the NGF product line This innovative frame has six rear horizontal troughs This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability and removal The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below The frame is 600 mm wide x 600 mm deep The built-in jumper storage panel will store up to 5 meters
Right Vertical Left
Vertical
Horizontal Trough (6) Jumper
Storage Panel
Trang 5Front Facing Fiber Main Distributing Frame (F3MDF)
The F3MDF is designed for single-sided access applications and may be mounted up against a wall or back-to-back to save floor space Unlike the FMDF, the more compact F3MDF is equipped with a single
230 mm horizontal trough The F3MDF has twelve FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below The frame is
600 mm wide x 480 mm deep The built-in jumper storage panel will store up to 5 meters of
jumper slack.
2.2 m
Jumper Storage Panel
Right Vertical Left
Vertical
FTB Mounting Position (12)
Horizontal Trough (6)
Trang 62.14 m
FTB Mounting Position
Jumper Storage Panel
Fiber Slim Rack
The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF It has six FTB mounting positions and is designed for single-sided access applications The Slim Rack is intended for use in a single frame application and should not be used in a multiframe lineup The built-in jumper storage panel will store up to 5 meters of jumper slack.
When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used on this frame.
NGF Fiber Slim Rack Frame Section
Trang 7Catalog Number NGF-TB
Block Style
12341
3
SCFC/ST®E-2000LX.5®/LC
Cable Exit Direction
UD
UpwardDownward
Block Configuration
ABCM
487296
144 (LX.5® or LC only)*
Block Orientation
LR
LeftRight
Adapter Type (62.5/125) Multimode
9A5YP
SC FC
ST®LX.5® (144 only)
LC (144 only)
OR
Adapter Type Singlemode
78L23Q4VNXK
SC ultra polish
SC ultra polish, zirconia sleeve
SC 8° angled polish
FC ultra polish
FC ultra polish,zirconia sleeve
FC 8° angled polish
ST® ultra polishE-2000 angled polishLX.5® ultra polish(144 only)LX.5® angled polish(144 only)
LC ultra polish (144 only)5
Fiber Termination Blocks (FTB) Unterminated
FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case the adapter packs for the block must be ordered separately (see page 12) Before ordering, determine the block orientation and cable exit direction Unterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame) All blocks with adapters only are configured to terminate single or dual jumpers on the rear of the block If a multi-fiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, a separate clamping kit is required (see page 6).
Vertical column of the frame the FTB is to be mounted on
Cable Exit Direction
Direction the equipment jumpers or OSP cable will exit from the FTB
Adapter Type
Specific adapter type required in the FTB
* 144 blocks using style 1, 2, or 3 cannot be used
in 26" wide NGF frames
Trang 8Fiber Termination Blocks
Clamping kit includes: Cable clamp, protective cover and fanout bracket It is required when terminating
a multifiber breakout style cable to the rear of the block.
72 position block loaded
with jumpers
72 position block loaded withmultifiber breakout cable 72 position block with clamping kit
Protective Cover
Fanout BracketCable Clamping Kit
Rear Cable Management Tray for 144 Block Conversion Kit
Block style originally purchased
96-position blocks with rear cable management NGF-ACCOSPKIT01
as shown above (blocks ordered before June 2002
96- or 144-position Left Up Blocks NGF-ACCRCMSLU
96- or 144-position Right Up Blocks NGF-ACCRCMSRU
96- or 144-position Left Down Blocks NGF-ACCRCMSLD
96- or 144-position Right Down Blocks NGF-ACCRCMSRD
O r d e r i n g I n f o r m a t i o n
Trang 9Fiber Termination Blocks (FTB) Preterminated
Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or stranded configurations All blocks are 100% factory tested to guarantee continuity and reliable connections Preterminated FTBs make installation quick and easy, reducing labor costs Before ordering, determine the block orientation and cable exit direction Preterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame) The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame).
Preterminated Fiber
Termination Blocks
arrive from the factory
with either IFC or
Ordering information follows on next page.
Fiber Termination Blockloaded with multifiberbreakout cable
Vertical column of the frame the FTB is to be mounted on
4 Cable Exit Direction
Direction the equipment jumpers or OSP cable will exit from the FTB
5 Adapter/Connector #1
Specific adapter/connector type required in the FTB Refers to the adapter/
connector type at the FTB
Trang 10†Other cable types are available upon request Please contact your ACD representative.
Length in meters
SCFC/ST®
E-2000LX.5®/LC
Cable Exit Direction
UD
UpwardDownward
Block Configuration
ABCM
487296
144 (LX.5® or
LC only)**
Block Orientation
LR
LeftRight
7
OSP Cable Type Singlemode
72 fiber ribbon dielectric
72 fiber stranded dielectric
96 fiber ribbon dielectric
96 fiber ribbon dielectric
96 fiber stranded dielectric
144 fiber stranded dielectric
144 fiber ribbon dielectric
VPVTVUVWENFLFM
AlcatelPirelliAlcatelPirelliPirelliPirelliPirelli
09A5YP
No connector/stub endSC
LC ultra polish (144 only)
Connector #2 Multimode (62.5/125)
OR
6
OR
Adapter/Connector #1 Multimode (62.5/125)
9A5YP
SCFC
ST®
LX.5® (144 only)
LC (144 only)
Adapter Type Singlemode
78L23Q4VNXK
SC ultra polish
SC ultra polish, zirconia sleeve
SC 8° angled polish
FC ultra polish
FC ultra polish,zirconia sleeve
FC 8° angled polish
ST® ultra polishE-2000 angled polishLX.5® ultra polish(144 only)LX.5® angled polish(144 only)
LC ultra polish (144 only)
5 Preterminated FTBs
See previous page for definition of variables.
* House cable will use Corning SMF28, Sumitomo, Alcatel or similar singlemode fiber based on current market availability
** 144 blocks using style 1, 2, or 3 cannot be used
in 26" wide NGF frames
Trang 11Fiber Combination Blocks (FCB)
Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame The blocks are available with several different adapter types in block configurations of 48, 72, or 96 positions Also, a 144 position FCB is available using an LX.5®adapter The termination portion of the fiber combination block utilizes sliding adapter packs to gain easy access to connectors on both the front and rear side of the block The block is available with factory-installed pigtails for easy installation Splice trays are shipped with the block if ordered with pigtails; otherwise trays must be ordered separately The block is shipped with a cable clamp for OSP/IFC The FCB occupies two mounting positions on a frame section Before ordering, determine the block orientation FCBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame).
Ordering information follows on next page.
Trang 12EmptyBare fusionHeat shrink fusionMechanical (elastomeric)Nortel QPAK
Swiss® ANTRotaryFibrLok®
16 position heat shrink fusion
E-2000LX.5® /LC
144 (LX.5® or LC only)
1
2
Number of Pigtail Assemblies
XX Number of assemblies
6
Pigtail Type
01245
No pigtails
12 fiber pigtail
12 fiber strandedMaxi-Strip
3
A59YP
FC
ST®
SCLX.5® (144 only)
LC (144 only)
4
OR
Adapter/Connector Type Multimode (62.5/125)
Adapter Type Singlemode
78L23Q4VNXK
SC ultra polish
SC ultra polish, zirconia sleeve
SC 8° angled polish
FC ultra polish
FC ultra polish,zirconia sleeve
FC 8° angled polish
ST® ultra polishE-2000 angled polishLX.5® ultra polish (144 only)LX.5® angled polish(144 only)
LC ultra polish (144 only)
4
1Fiber Combination Blocks (FCB)
Type of pigtail required
Number of Pigtail Assemblies
Number of pigtails to be pre-installed in the FCB
Splice Chip
Type of splice chip required for splice trays
1144 termination block requires the use of either:
Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing
Nortel QPAK splice tray when using single fiber heat shrink fusion splicing
144 blocks using block style 1, 2, or 3 cannot be used in 26" wide NGF frames
Trang 13Empty tray*
Bare fusionHeat shrink fusionMechanical (elastomeric)Nortel QPAK
Swiss ANTRotaryFibrLok®
* Maximum size of chip allowed in empty tray: 3"H x 2.5"W x 3.6"L
Note: For LX.5® FCB with 12 fiber ribbon
pigtails, select mechanical splicing only.
For LX.5® FCB with 12 fiber stranded pigtails select Nortel QPAK (compatible with heat
shrink fusion), bare fusion or Swiss ANT only.
Number of Splices
1224
Trang 14144-Position (block code'E')
144-Position (block code'M')
J (not shown below)
H (not shown below)
K (not shown below)
Sliding Adapter Packs
Sliding adapter packs house groups of fiber optic adapters and are mounted in Fiber Termination Blocks to provide easy access to connectors Sliding Adapter Packs are available with SC, FC, ST®, E-2000 and LX.5®
adapters The adapters come in packs of two, four, six and eight depending on the adapter type and the desired termination density See table below for configuration guidelines.
* Sliding Adapter Pack Configuration GuidelinesBlock
Adapter Pack Configuration
Adapter Pack Option
Option A
(SC shown)
Option B(FC shown)
Option E(ST®shown)
Option F(E-2000 shown)
Option G(FC shown)
Option H(LX.5®only)
Catalog Number NGF- SAP
Adapter Pack Option*
ABEFGH
JK
4 pack / 4 pack
6 pack / 6 pack(all block code "M" blocks)
0
Adapter Type Multimode
9A5Y
SC FC
LC ultra polish (144 only)
5
Trang 15Value-Added Module System
ADC’s Next Generation Frame (NGF) Value-Added
Modules are designed to support emerging circuit
requirements This high-density fiber frame
solution provides unlimited expansion while
optimizing fiber cable management The NGF
system uses Mini Value-Added Modules to
incorporate optical splitters for circuit monitoring
and video distribution Mini Value-Added Modules
can also be configured with wavelength division
multiplexing capabilities to increase transmission
capacity over existing fiber lines Various input
and output interface options are available.
Features:
• Enclosed plug-in modules
Optical components are protected fromphysical and environmental damage
• Flexible platform
Modules can be created for new applicationsquickly and easily to meet customerrequirements
• Monitor and/or test
Enables providers to troubleshoot networkswithout forcing disruption of service
• Custom configurations
Custom splitter configurations available upon request
The NGF VAM chassis is designed to mount
on all standard NGF frame styles and is
interchangeable with termination, splice, and
storage modules Each chassis accommodates
up to twelve Mini-VAM modules.
NGF - TB D
Block Orientation
LR
LeftRight
Cable Exit Direction (Rear)
UD
UpwardDownward
NGF VAM Chassis
* NGF VAMs with LX.5®or LC adapters can be placed in any of these block styles
Please contact ADC Technical Assistance Center at 1-800-366-3891 with any questions
VAM Chassis