KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICEPage 1 of 2 50/125 µm Multimode Fiber FEATURES Original standard graded index Multimode fiber user usable at
Trang 1KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICE
Page 1 of 2
50/125 µm Multimode Fiber
FEATURES
Original standard graded index Multimode fiber user usable at both 850nm and 1300nm wavelengths
Dual mechanically strippable acrylate coatings are appliances on glass to provide excellent protection in different environmental conditions
Excellent dimensional control for low splice loss
APPLICATIONS
Suitable media for short distance transmission, such as local area network (Ethernet, ATM and Fibre Channel), CCTV system, where fiber attenuation and bandwidth requirements are modest
SPECIFICATIONS
Standard
Meet International Standard IEC 793 and CCITT Recommendation G.651
Comply to ISO11801 and EIA/TIA 568A (550 meter for 1000BaseSX and 1000BaseLX application)
Optical Parameters
• Attenuation (dB/km) Typical
• Bandwidth (MHz-km) Typical
Physical Parameters
• Cladding Diameter (µm) 125.0 ± 2.0
• Coating Diameter (µm) 250 ± 10
• Cladding Non-Circularity ≤ 2%
• Core/ Cladding Concentricity Error(µm)≤ 3.0
Trang 2KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICE
Page 2 of 2
Mechanical & Environmental Characteristics
• Tensile Strength
• Minimum Bend Radius
(Installation) 20 x Cable Diameter
• Operation Temperature - 40 oC to + 65 oC
Cable Marking
• KRONE Part Number MM 50/125 Number of Fibres Metering marking
The Color Code of the Individual Fibers and Loose Tubes
No of Fibers/
Loose Buffer Tubes
Color No of Fibers/
Loose Buffer Tubes
Color
Optical Fibers Jelly Compound Loose Buffer Tube Filler(if necessary) Jelly Compound Dielectric CSM Core Wrapping Plastic Tape Dielectric Strength Member Outer MDPE Jacket