ADC’s compact building cables are designedfor use in backbone or horizontal cabling applications.. The distribution cable features 900 µm tight buffered fibers designed to allow for one-

Trang 1

ADC’s compact building cables are designed

for use in backbone or horizontal cabling

applications The distribution cable features

900 µm tight buffered fibers designed to allow

for one-pass mechanical stripping

Constructions above 24 fibers are available

with 6 fiber subgroups (up to 72 fibers total)

and 12 fiber subgroups (up to 144 fibers total)

Features:

• 900 µm tight buffered fibers designed for

one-pass mechanical stripping

• Constructions above 24 fibers feature

subunits

Applications:

• Designed for use in backbone or horizontal cable applications

• Vertical cable runs from cross-connects

to telecommunication rooms

• Vertical cable runs from telecommunication rooms to consolidation points

Compliances:

• Telcordia GR-409-CORE, EIA/TIA FOTPs

• TIA/EIA 568-B

• (UL) 1666, NEC OFNR, FT-4

Trang 2

Compact Building Cables: Riser

PVDF Outer Jacket

900 µm Tight Buffered Fiber Aramid Yarn Strength Member

900 µm Tight Buffered Fiber

Aramid Yarn Strength Member

Dielectric Central Strength Member

12 Fiber Subunit PVDF Outer Jacket

Rip Cord

Central Strength Member

Specifications

MECHANICAL CHARACTERISTICS:

Maximum Tensile Load

Short Term

6-8 12-24 36-144

1000 (220)

1800 (400)

2700 (600)

Maximum Safe Operating Load

Long Term

6-8 12-24 36-144

300 (67)

600 (135)

1000 (224)

ENVIRONMENTAL CHARACTERISTICS:

Storage Temperature -40˚ to 70 ˚C (-40˚ to 158 ˚F)

Operating Temperature -20˚ to 70 ˚C (-4˚ to 158 ˚F)

Installation Temperature 0˚ to 70 ˚C (32˚ to 158 ˚F)

Trang 3

Compact Building Cables: Riser

TRANSMISSION PERFORMANCE—Guaranteed Minimum Link Lengths:

310 Gigabit Ethernet distance guarantees at the long wavelength are achieved

via four 3.125 Gbps channels multiplexed with WWDM technology

Gigabit Ethernet Link Length (SX/LX)

10 Gigabit Ethernet Link Length (SR/LX4) 3

Multimode

62.5/125 Enhanced 500 m/1000 m 65 m/300 m

50/125 Enhanced 750 m/2000 m 110 m/300 m

50/125 Ultra 300 900 m/550 m 300 m/300 m

50/125 Ultra 550 1040 m/550 m 550 m/300 m1

(LR/ER)

1Bandwidth measurements specified overfilled launch conditions (OFL)

2Bandwidth measurements specified by laser launch

Maximum Attenuation

(dB/km)

Typical Attenuation

(dB/km)

Bandwidth1

(MHz/km)

850 nm/1300 nm 850 nm/1300 nm 850 nm/1300 nm Multimode

1310 nm/1550 nm 1310 nm/1550 nm 1310 nm/1550 nm

OPTICAL PERFORMANCE:

Trang 4

SPEC SHEET

*Replace YYYwith fiber type:

010 = Singlemode 050 = 50/125 µm Multimode

062 = 62.5/125 µm Multimode 50E = 50/125 µm Enhanced Multimode

62E = 62.5/125 µm Enhanced Multimode 50U = 50/125 µm Ultra Multimode for 300 m 10 Gbps

5U5 = 50/125 µm Ultra Multimode for 550 m 10 Gbps

36 17.2 0.68 262 176 25.8 10.2 17.2 6.8 6036INHCBCYYY

48 19.8 0.78 307 206 29.7 11.7 19.8 7.8 6048INHCBCYYY

72 21.6 0.85 414 278 32.4 12.8 21.6 8.5 Q072INHCBCYYY

96 22.3 0.88 399 268 33.5 13.2 22.3 8.8 Q096INHCBCYYY

144 23.9 0.94 430 289 35.9 14.1 23.9 9.4 Q144INHCBCYYY