Bản vẽ shop drawing chống thấm tầng hầm dự án Sunwah Pearl 52 tầng
Trang 1SHOP DRAWING FOR WATERPROOFING FOR BASEMENT B2, B1
SUNWAH PEARL PROJECT
CONDOMINIUM BLOCKS OF WARD, BINH THANH DISTRICT, HCM CITY
Trang 2DC 1X800 DC 1X800 DC 1X800 DC 1X800 DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X1000 DC 1X1000 DC 1X1000 DC 1X800 DC 1X800
DC 1X800
DC 1X800
DC 1X800 DC 1X800 DC 1X800
DC 1X800 DC 1X800
DC 1X800A
DC 1X800 DC 1X800
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1200
DC 1X1000
DC 1X800
DC 1X800
DC 1X1200 DC 1X1000
DC 1X1000 DC 1X1000
DC 1X1000 DC 1X1200 DC 1X1000 DC 1X1000 DC 1X1200
DC 1X1000
DC 1X1000
DC 1X1200
DC 1X1200 DC 1X1200 DC 1X1000
DC 1X1000
DC 1X1200
DC 1X1200 DC 1X1200 DC 1X1200 DC 1X1000 DC 1X1200
DC 1X1200
DC 1X1000
DC 1X1200 DC 1X1200 DC 1X1200
DC 1X1200 DC 1X1200
DC 1X1000
DC 1X1000
DC 1X1200 DC 1X1200
DC 1X1200 DC 1X1200 DC 1X1000 DC 1X1200
DC 1X1200
DC 1X1200 DC 1X1000 DC 1X1200
DC 1X800
DC 1X1000
DC-4-P2A,P2B
WATERPROOFING FOR PILE CAP AT ZONE 1PLAN LAYOUT
KEYPLAN :
TYPICAL DETAIL :
NOTE:
1 : Lean concrete/
WATERPROOFING FOR PILE CAP
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 3DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800 DC 1X800
DC 1X800 DC 1X800
DC 1X800 DC 1X800 DC 1X1000
DC 1X1000
DC 1X1000 DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X800
DC 1X800A
DC 1X1000
DC 1X800
DC 1X1200 DC 1X1200
DC 1X1200 DC 1X1200 DC 1X1200
DC 1X1200
DC 1X1200
DC 1X800
DC 1X1200
DC-4-P2A,P2B
DC 1X800
DC 1X800
DC 1X1000
DC 1X1000
DC 1X1200
DC-1-P4D
WATERPROOFING FOR PILE CAP AT ZONE 2 PLAN LAYOUT
TYPICAL DETAIL :
NOTE:
1 : Lean concrete/
WATERPROOFING FOR PILE CAP
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 4DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800DC 1X800
DC 1X800
DC 1X800 DC 1X800
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X800 DC 1X800B (1)
DC 1X1000
DC 1X1000
DC 1X800 DC 1X800
DC 1X1000 DC 1X1000
DC 1X1000 DC 1X800 DC 1X800 DC 1X800
DC 1X800
DC 1X800 DC 1X800
DC 1X800
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1200
DC 1X1200
DC 1X800 DC 1X1000 DC 1X1000
DC 1X800
DC 1X800
DC 1X1000 DC 1X1000 DC 1X1000
DC 1X800
DC 1X800
DC 1X800 DC 1X1200
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1200 DC 1X1200
DC 1X1200
DC 1X1200
DC 1X1200
DC 1X1000 DC 1X800 DC 1X800
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000 DC 1X800 DC 1X800
DC 1X1200
DC-3-P1A-B2
DC-1-P2C
WATERPROOFING FOR PILE CAP AT ZONE 3 PLAN LAYOUT
KEYPLAN :
TYPICAL DETAIL :
NOTE:
1 : Lean concrete/
WATERPROOFING FOR PILE CAP
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 5DC 1X800 DC 1X800
DC 1X800
DC 1X800
DC 1X800 DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800 DC 1X800
DC 1X800
DC 1X1000
DC 1X1000
DC 1X1000 DC 1X1000
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X800
DC 1X1000 DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000 (2)
DC 1X1000
DC 1X1200
DC 1X1200
DC 1X800 DC 1X1000 DC 1X1000 DC 1X1000
DC 1X1000 DC 1X1000 DC 1X1000 DC 1X1000
DC 1X800
DC 1X1200
DC 1X1000 DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC 1X1000
DC-2-P1A-B2
DC-3-P1A-B2
WATERPROOFING FOR PILE CAP AT ZONE 4 PLAN LAYOUT
TYPICAL DETAIL :
NOTE:
1 : Lean concrete/
WATERPROOFING FOR PILE CAP
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 6DC-1A-P5C
DC-1A-P5C
DC-2A-P3A
DC-4B-P4C
DC-6-P4C,P3D
DC-3-P3C,P2B DC-3-P3F,P2B
DC-22-P3F,P4C DC-2A-P3B
DC-4A-P4C
DC-6-P4B
WATERPROOFING FOR BASEMENT SLAB B2 AT ZONE 1PLAN LAYOUT
KEYPLAN :
TYPICAL DETAIL :
NOTE:
WATERPROOFING FOR BASEMENT TANK
FOR THE PC ABOVE B2 BASEMENT SLAB/
WATERPROOFING FOR PILE CAP
WATERPROOFING FOR B2 SLAB
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 7DC-3A-P3D,P4D
DC-2-P4E
DC-18-P4B,P4D
DC-3B-P3D,P4D DC-4-P5B
WATERPROOFING FOR BASEMENT SLAB B2 AT ZONE 2 PLAN LAYOUT
TYPICAL DETAIL :
NOTE:
WATERPROOFING FOR BASEMENT TANK
FOR THE PC ABOVE B2 BASEMENT SLAB/
WATERPROOFING FOR PILE CAP
WATERPROOFING FOR B2 SLAB
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 8DC-1-P5A
DC-1-P5B
DC-1-P2C
DC-1-P5A
DC-2-P3D DC-6-P4B
DC-1-P5B DC-2B-P3A
DC-2C-P3A
DC-1B-P5C
DC-1A-P4A
DC-1-P5A
DC-7-P4B
DC-2B-P3B
DC-4-P4B
DC-1A-P4A (2)
KEYPLAN :
TYPICAL DETAIL :
WATERPROOFING FOR BASEMENT SLAB B2 AT ZONE 3 PLAN LAYOUT
NOTE:
WATERPROOFING FOR BASEMENT TANK
FOR THE PC ABOVE B2 BASEMENT SLAB/
WATERPROOFING FOR PILE CAP
WATERPROOFING FOR B2 SLAB
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 9DC-2-P4E
DC-1-P3F
DC-1-P3F
DC-2C-P3A
DC-2C-P3A DC-1B-P4A
DC-2D-P3A
DC-2D-P3A DC-4C-P4C
DC-10-P4C DC-1-P4C
DC-1-P3D
DC-1-P3D
DC-1-P4C
TYPICAL DETAIL :
WATERPROOFING FOR BASEMENT SLAB B2 AT ZONE 4 PLAN LAYOUT
NOTE:
WATERPROOFING FOR BASEMENT TANK
FOR THE PC ABOVE B2 BASEMENT SLAB/
WATERPROOFING FOR PILE CAP
WATERPROOFING FOR B2 SLAB
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 10KEYPLAN :
NOTE:
5 : Hyperstop BD.
WATERPROOFING FOR SHEAR WALL
WATERPROOFING FOR SHEAR WALL B2, B1 FLOOR PLAN LAYOUT
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 11ZONE 1 ZONE 2
SEPTIC TANK B2 - GREASE TRAP FOR SERVICE PLAN
LAYOUT
NOTE:
7 : Hyperstop BD.
WATERPROOFING FOR TANK SLAB
WATERPROOFING FOR SEPTIC TANK B2 - GREASE TRAP FOR SERVICE PLAN LAYOUT
WATERPROOFING FOR SEPTIC TANK B1 PLAN LAYOUT
WATERPROOFING FOR TANK WALL
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 12KEYPLAN :
DOMESTIC WATER TANK TOWER B1, B2, B3, SEPTIC TANK B3
WATERPROOFING FOR DOMESTIC WATER TANK TOWER B3 WATERPROOFING FOR DOMESTIC WATER TANK TOWER B1, B2 PLAN LAYOUT
WATERPROOFING FOR SEPTIC TANK B3 PLAN LAYOUT
NOTE:
7 : Hyperstop BD.
WATERPROOFING FOR TANK SLAB
WATERPROOFING FOR TANK WALL
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 13WATERPROOFING FOR RAMP 01 PLAN LAYOUT/
NOTE/ :
1,5kg/m2.
WATERPROOFING FOR RAM SLOPE/
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
TRONG BPTC.
WATERPROOFING FOR RAMP 03 PLAN LAYOUT/
WATERPROOFING FOR RAMP 02 PLAN
Trang 14KEYPLAN :
NOTE:
5 : Sika flex.
WATERPROOFING FOR BIN CENTER
WATERPROOFING FOR BIN CENTER 1 PLAN LAYOUT
WATERPROOFING FOR BIN CENTER 2 PLAN LAYOUT
WATERPROOFING FOR BIN CENTER 3 PLAN LAYOUT
WATERPROOFING FOR BIN CENTER 4 PLAN LAYOUT
DRY AREA WET AREA
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 15TYPICAL DETAIL :
WATERPROOFING FOR WC, DRESSING ROOM
FOR CORNER OF WALL
FOR DOWN PIPE
FOR DOOR FOOTING
WATER PROOFING FOR MALE, FEMALE STAFF
DRESSING ROOM PLAN LAYOUT
WATER PROOFING FOR MALE, FEMALE WC ROOM
PLAN LAYOUT
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
NOTE:
5 : Sika flex.
Trang 16LIFT PIT EB-04
LIFT PIT EB-03 LIFT PIT
EB-02
LIFT PIT EB-01 LIFT PIT ER-01 LIFT PIT ER-02
LIFT PIT ER.S
LIFT CPL-01
STAIRCASE/LIFT SP.1
WATERPROOFING FOR LIFT PIT AT BASEMENT PLAN LAYOUT
KEYPLAN :
TYPICAL DETAIL :
FOR LIFT PIT AT B2 BASEMENT
NOTE:
6 : B2 basement concrete slab/
ZONE 4
WATERPROOFING FOR LIFT PIT
FOR LIFT PIT AT B1 BASEMENT
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 17WATERPROOFING FOR MOTORCYCLE PARKING B1 PLAN LAYOUT
TYPICAL DETAIL :
NOTE:
WATERPROOFING FOR MOTOCYCLE
DRY AREA WET AREA
FOR CONCRETE SLAB
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/
Trang 18KEYPLAN :
TYPICAL DETAIL :
NOTE:
1,5kg/m2.
LEGEND :
WATERPROOFING FOR DRAINAGE
WATERPROOFING FOR DRAINAGE B1 FLOOR PLAN LAYOUT
- ALL SURFACES MUST BE CLEAN, FREE FROM GREASE,
OIL, LOOSELY ADHERING PARTICLES AND DRY BEFORE
DOING THE WATERPROOF WORK/
- ALL DIMENSIONS MUST BE CHECKED ON SITE/
- THE DETAIL MATERIAL BRAND 0R SPECIFICATION CAN BE
SEEN IN THE METHOD STATEMENT OF WATERPROOFING/