Annex B Cable ANEXT loss and AFEXT loss reference test procedure normative... Annex C Connecting hardware ANEXT loss and AFEXT loss reference test procedure... Annex D Channel ANEXT loss
Trang 2TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM
Trang 3TRANSMISSION PERFORMANCE SPECIFICATIONS
Trang 47.3.2.1 Cable power sum ELFEXT 23
Trang 6G.4.3 Augmented cCategory 6 modular cord test head return loss 60
Trang 8Table 17 – Augmented category 6 channel PSNEXT loss 17
Trang 9Table H.2 – Augmented category 6 de-embedded test plug NEXT loss limits 65
Trang 11Category 6 Category 3 Category 5 Category 5e Category 6 Augmented Category 6 1) Category 3 plug performance requirements are assumed to be less restrictive than category 5e
28
Trang 134.2 Acronyms and abbreviations
Work area cord A Telecommunications outlet/
Optional transition cabling B connector WA
Horizontal cabling C Optional transition/consolidation
Patch cord or jumper cable D point connector CP
Telecommunications room Horizontal cross-connect or
equipment cord E interconnect C1, C2
Trang 14The permanent link test configuration is defined in ANSI/TIA/EIA-568-B.1 A supplemental
Test equipment cord F Telecommunications outlet/
Optional transition cabling B connector WA
Horizontal cabling C Optional transition/consolidation
Horizontal cross-connect or interconnect C1
Maximum length
B + C 90 m (295 ft)
Test instrument
instrumentCP
Permanent link under test
Trang 161.00 2.0 4.00 3.7 8.00 5.2 10.00 5.9 16.00 7.4 20.00 8.3 25.00 9.3 31.25 10.4 62.50 14.9 100.00 19.0 200.00 27.5 250.00 31.0 300.00 34.2 400.00 40.0 500.00 45.3
27
28
Trang 177.1.2 Connecting hardware insertion loss
1.00 0.1 4.00 0.1 8.00 0.1 10.00 0.1 16.00 0.1 20.00 0.1 25.00 0.1 31.25 0.1 62.50 0.2 100.00 0.2 200.00 0.3 250.00 0.3 300.00 0.3 400.00 0.4 500.00 0.4
11
12
Trang 187.1.3 Cabling insertion loss
f f
oss InsertionL channel≤1.05(1.8 +0.01 +0.2/ )+4⋅0.02 dB (4)
1 ( 03 0
100 ,
f f f
1.00 2.2 4.00 4.1 8.00 5.7 10.00 6.4 16.00 8.1 20.00 9.1 25.00 10.2 31.25 11.4 62.50 16.3 100.00 20.8 200.00 30.0 250.00 33.8 300.00 37.3 400.00 43.6 500.00 49.3
Trang 197.1.3.2 Permanent link insertion loss
f f f
1.00 1.9 4.00 3.5 8.00 4.9 10.00 5.5 16.00 6.9 20.00 7.7 25.00 8.7 31.25 9.7 62.50 13.9 100.00 17.9 200.00 26.0 250.00 29.4
Trang 2015 3
NEXT loss (dB)
0.150 86.7 0.772 76.0 1.00 74.3 4.00 65.3 8.00 60.8 10.00 59.3 16.00 56.2 20.00 54.8 25.00 53.3 31.25 51.9 62.50 47.4 100.00 44.3 200.00 39.8 250.00 38.3 300.00 37.1 400.00 35.3 500.00 33.8
24
NOTE - 0.150 MHz is for reference purposes only
25
26
Trang 217.2.1.2 Connecting hardware pair-to-pair NEXT loss
Trang 227.2.1.3 Work area, equipment, and patch cord pair-to-pair NEXT loss
IL cable NEXT connectors
NEXT limit
1010
log10_
2010
log20
conn IL cable IL conn NEXT conn
NEXT connectors
8
9
100100
,
h CableLengt m
cable IL IL DeRating cable
NEXT loss (dB)
IL ,100 is the insertion loss of 100 meters of solid conductor cable as specified in clause
Trang 23NEXT ,100 is the NEXT loss test limit for 100 m cable as specified in clause 7.2.1.1
2 m cord limit (dB)
5 m cord limit (dB)
10 m cord limit (dB)
1.00 65.0 65.0 65.0 65.0 4.00 65.0 65.0 65.0 65.0 8.00 65.0 65.0 65.0 64.8 10.00 65.0 65.0 64.5 63.0 16.00 62.7 62.0 60.5 59.1 20.00 60.7 60.1 58.7 57.3 25.00 58.8 58.2 56.8 55.4 31.25 56.9 56.3 54.9 53.6 62.50 51.0 50.4 49.2 48.1 100.00 47.0 46.4 45.4 44.5 200.00 41.1 40.7 39.9 39.3 250.00 39.3 38.9 38.1 37.7 300.00 36.4 36.2 35.9 35.8 400.00 31.8 31.9 32.1 32.5 500.00 28.2 28.4 29.0 29.8
14
Editor’s Note: The values in the above table are TBD
15
16
Trang 247.2.1.4 Channel pair-to-pair NEXT loss
))100/log(
2054(10220
))100/log(
153.44(10log(
20
f f
channel NEXT
−
−
⋅+
15.27
NEXT loss (dB)
1.00 65.0 4.00 63.0 8.00 58.2 10.00 56.6 16.00 53.2 20.00 51.6 25.00 50.0 31.25 48.4 62.50 43.4 100.00 39.9 200.00 34.8 250.00 33.1 300.00 31.7 400.00 28.7 500.00 26.1
))100/log(
2054(10220
))100/log(
153.44(10log(
Trang 25The values in the table 13 are provided for information only
NEXT loss (dB)
300.00 31.7 330.00 31.0 400.00 28.3 500.00 24.9
)) 100 / log(
20 54 ( 10 20
)) 100 / log(
15 3 44 ( 10 log(
20
f f
NEXTPL
−
− +
13.33
1.00 65.0 4.00 64.1 8.00 59.4 10.00 57.8 16.00 54.6 20.00 53.1
Trang 267.2.2 Power sum NEXT loss
10 log(
15 3
PSNEXT loss (dB)
0.150 84.7 0.772 74.0 1.00 72.3 4.00 63.3 8.00 58.8 10.00 57.3 16.00 54.2 20.00 52.8 25.00 51.3 31.25 49.9 62.50 45.4 100.00 42.3 200.00 37.8 250.00 36.3 300.00 35.1 400.00 33.3 500.00 31.8
Trang 277.2.2.2 Channel power sum NEXT loss
))100/log(
2050(10220
))100/log(
153.42(10log(
20
f f
channel PSNEXT
−
−
⋅+
43.26
1.00 62.0 4.00 60.5 8.00 55.6 10.00 54.0 16.00 50.6 20.00 49.0 25.00 47.3 31.25 45.7 62.50 40.6 100.00 37.1 200.00 31.9 250.00 30.2 300.00 28.8 400.00 25.8 500.00 23.2
20 50 ( ))
100 / log(
15 3 42
Trang 28The values in the table 19 are provided for information only
300.00 28.8 330.00 28.0 400.00 25.3 500.00 21.8
)) 100 / log(
20 50 ( 10 20
)) 100 / log(
15 3 42 ( 10 log(
20
f f
PSNEXTPL
⋅
−
− +
44.344
1.00 62.0 4.00 61.8 8.00 57.0 10.00 55.5 16.00 52.2 20.00 50.7 25.00 49.1 31.25 47.5 62.50 42.7 100.00 39.3 200.00 34.3 250.00 32.7 300.00 31.4 400.00 27.1 500.00 23.8
17
Trang 297.3 ELFEXT and FEXT loss
20 8
1.00 67.8 4.00 55.8 8.00 49.7 10.00 47.8 16.00 43.7 20.00 41.8 25.00 39.8 31.25 37.9 62.50 31.9 100.00 27.8 200.00 21.8 250.00 19.8 300.00 18.3 400.00 15.8 500.00 13.8
24
Trang 307.3.1.2 Connecting hardware pair-to-pair FEXT loss
20 1
Trang 317.3.1.3 Channel pair-to-pair ELFEXT
4 10
log(
conn cable FEXT ELFEXT
channelELFEXT
−
−
⋅ +
ELFEXT (dB)
1.00 63.3 4.00 51.2 8.00 45.2 10.00 43.3 16.00 39.2 20.00 37.2 25.00 35.3 31.25 33.4 62.50 27.3 100.00 23.3 200.00 17.2 250.00 15.3 300.00 13.7 400.00 11.2 500.00 9.3
14
15
Trang 327.3.1.4 Permanent link pair-to-pair ELFEXT
conn cable
PL
FEXT ELFEXT
ELFEXT
− +
ELFEXT (dB)
1.00 64.2 4.00 52.1 8.00 46.1 10.00 44.2 16.00 40.1 20.00 38.2 25.00 36.2 31.25 34.3 62.50 28.3 100.00 24.2 200.00 18.2 250.00 16.2 300.00 14.6 400.00 12.1 500.00 10.2
14
15
Trang 337.3.2 Power sum ELFEXT
10 log(
20 8
1.00 64.8 4.00 52.8 8.00 46.7 10.00 44.8 16.00 40.7 20.00 38.8 25.00 36.8 31.25 34.9 62.50 28.9 100.00 24.8 200.00 18.8 250.00 16.8 300.00 15.3
Trang 347.3.2.2 Channel power sum ELFEXT
4 10
log(
conn cable PSFEXT PSELFEXT
channelPSELFEXT
−
−
⋅ +
1.00 60.3 4.00 48.2 8.00 42.2 10.00 40.3 16.00 36.2 20.00 34.2 25.00 32.3 31.25 30.4 62.50 24.3 100.00 20.3 200.00 14.2 250.00 12.3 300.00 10.7 400.00 8.2 500.00 6.3
14
15
Trang 357.3.2.3 Permanent link power sum ELFEXT
conn cable
PL
PSFEXT PSELFEXT
PSELFEXT
− +
PSELFEXT (dB)
1.00 61.2 4.00 49.1 8.00 43.1 10.00 41.2 16.00 37.1 20.00 35.2 25.00 33.2 31.25 31.3 62.50 25.3 100.00 21.2 200.00 15.2 250.00 13.2 300.00 11.6 400.00 9.1 500.00 7.2
15
16
Trang 36Return loss (dB)
1.00 20.0 4.00 23.0 8.00 24.5 10.00 25.0 16.00 25.0 20.00 25.0 25.00 24.3 31.25 23.6 62.50 21.5 100.00 20.1 200.00 18.0 250.00 17.3 300.00 16.8 400.00 15.9 500.00 15.2
21
22
Trang 377.4.2 Stranded conductor cable return loss
Return loss (dB)
Return loss (dB)
1.00 20.0 4.00 23.0 8.00 24.5 10.00 25.0 16.00 25.0 20.00 25.0 25.00 24.2 31.25 23.3 62.50 20.7 100.00 19.0 200.00 16.4 250.00 15.6 300.00 14.9 400.00 13.8 500.00 13.0
14
15
Trang 387.4.3 Connecting hardware return loss
1 ≤ f < 79 (TBD)
79 (TBD) ≤ f ≤ 500
30 28-20log(f /100) (TBD)
1.00 30.0 4.00 30.0 8.00 30.0 10.00 30.0 16.00 30.0 20.00 30.0 25.00 30.0 31.25 30.0 62.50 30.0
Trang 397.4.4 Work area, equipment, and patch cord return loss
1 ≤ f < 25
25 ≤ f ≤ 250
250 < f < 500
24+3log(f/25) 24-10log(f/25) 14-15log(f/250) (TBD)
6
Table 38 - Augmented category 6 work area, equipment, and patch cord return loss
7
Frequency (MHz)
Return loss (dB)
1.00 19.8 4.00 21.6 8.00 22.5 10.00 22.8 16.00 23.4 20.00 23.7 25.00 24.0 31.25 23.0 62.50 20.0 100.00 18.0 200.00 15.0 250.00 14.0 300.00 12.8 (TBD)
Trang 407.4.5 Cabling return loss
Return loss (dB)
1 ≤ f < 10
10 ≤ f < 40
40 ≤ f ≤ 500
19 24-5log(f) 32-10log(f) (6 dB minimum)
1.00 19.0 4.00 19.0 8.00 19.0 10.00 19.0 16.00 18.0 20.00 17.5 25.00 17.0 31.25 16.5 62.50 14.0 100.00 12.0 200.00 9.0 250.00 8.0 300.00 7.2 400.00 6.0 500.00 6.0
13
14
Trang 417.4.5.2 Permanent link return loss
Return loss (dB)
10-20log(f /250) (TBD) (6 dB minimum) (TBD)
Return loss (dB)
1.00 19.1 4.00 21.0 8.00 21.0 10.00 21.0 16.00 20.0 20.00 19.5 25.00 19.0 31.25 18.5 62.50 16.0 100.00 14.0 200.00 11.0 250.00 10.0 300.00 8.4 400.00 6.0 500.00 6.0
12
13
Trang 427.5 Propagation delay/delay skew
Min Velocity of Propagation (%)
Max Delay Skew (ns/100 m)
TBD TBD TBD TBD TBD
TBD TBD TBD TBD TBD
7.5.2 Cabling propagation delay
Trang 437.5.4 Cabling propagation delay skew
TCL (dB)
1.00 40.0 4.00 40.0 8.00 40.0 10.00 40.0 16.00 38.0
Trang 441.00 40.0 4.00 40.0 8.00 40.9 10.00 40.0 16.00 40.9 20.00 40.0 25.00 40.0 31.25 38.1 62.50 32.1 100.00 28.0 200.00 22.0 250.00 20.0 300.00 TBD 400.00 TBD 500.00 TBD
Trang 451.00 35.0 4.00 23.0 8.00 16.9 10.00 15.0 16.00 10.9 20.00 9.0 25.00 7.0 30.00 5.5
12
13
Trang 46ELTCTL (dB)
1.00 40.0 4.00 40.0 8.00 40.0 10.00 40.0 16.00 40.0 20.00 40.0 25.00 40.0 31.25 38.1 62.50 32.1 100.00 28.0 200.00 22.0 250.00 20.0 300.00 TBD 400.00 TBD 500.00 TBD
Trang 477.7.3 Channel PSANEXT loss
PSANEXT loss (dB)
1.00 75.0 4.00 74.0 8.00 71.0 10.00 70.0 16.00 68.0 20.00 67.0 25.00 66.0 31.25 65.1 62.50 62.0 100.00 60.0 200.00 55.5 250.00 54.0 300.00 52.8 400.00 51.0 500.00 49.5
Trang 487.8 Average ANEXT loss and PSANEXT loss
Average PSANEXT loss (dB)
1.00 81.0 4.00 75.0 8.00 72.0 10.00 71.0 16.00 69.0 20.00 68.0 25.00 67.0 31.25 66.1 62.50 63.0 100.00 61.0 200.00 56.5 250.00 55.0 300.00 53.8 400.00 52.0 500.00 50.5
18
19
Trang 497.9 AFEXT loss, AELFEXT, and PSAELFEXT
PSAELFEXT (dB)
Trang 507.9.4 Permanent Link PSAELFEXT
Average PSANEXT loss (dB)
1.00 81.0 4.00 69.0 8.00 62.9 10.00 61.0 16.00 56.9 20.00 55.0 25.00 53.0 31.25 51.1 62.50 45.1 100.00 41.0 200.00 35.0 250.00 33.0 300.00 31.5 400.00 29.0 500.00 27.0
20
21
Trang 51Annex A Cabling measurement requirements (normative)
Impedance, primary 1) 1 ≤ f ≤ 500 50 Ω unbalanced
Impedance, secondary 1 ≤ f ≤ 500 100 Ω balanced
Return loss, bi-directional 2) 1 ≤ f < 3
3 ≤ f ≤ 500
15 dB minimum
20 dB minimum Return loss, common mode 2) 1 ≤ f ≤ 500 20 dB minimum
Longitudinal balance 2), 3) 1 ≤ f < 100
100 ≤ f ≤ 500
60 dB minimum
50 dB minimum Output signal balance 2) 1 ≤ f ≤ 500 50 dB minimum
Common mode rejection 2) 1 ≤ f ≤ 500 50 dB minimum
1) Primary impedance may differ, if necessary, to accommodate analyzer outputs other than
Trang 52Figure A.1 depicts the proper test configurations for qualifying test baluns to the requirements of
Trang 53Annex B Cable ANEXT loss and AFEXT loss reference test procedure (normative)
Trang 54Annex C Connecting hardware ANEXT loss and AFEXT loss reference test procedure
Trang 55For pair-to-pair AFEXT loss measurement, it is recommended that the far-end of the disturbing
DUT1 (Victim)
CMDM 4 Pair Termination.
Cable.
L>40m Cable; L=TBD
Trang 5610 10
10 log(
10 10
10 log(
Trang 57Annex D Channel ANEXT loss and AFEXT loss laboratory measurement procedures
Trang 58D.4 Determining number of disturbing components
Trang 59D.7 Channel ANEXT loss and AFEXT loss measurements and computations
Trang 60Annex E Field measurement method for alien crosstalk (normative)
Trang 61E.5.2 Permanent link testing
Trang 62E.5.5 Measurement floor of the test device with permanent link adapter test cords
device
Trang 63E.6.2 Measuring PSAFEXT loss in the channel configuration
Plug with 100 Ω terminations
Feedback path
Test device
Trang 64Assuming that a main and remote unit have a separate measurement control communication path
Plug with 100 Ω terminations
Signaling feedback path
Test
device
device (remote) Plug with 100 Ω terminations
Trang 65E.7 Processing measurement data
10 log(
1 ,
X WP
10 log(
,
PSANEXT PSANEXT
total X WP
10 log(
1 ,
X WP
Trang 66When the alien FEXT loss of another disturber link #2 is added, the sum total PSAFEXT loss is
1
computed by equation (E-6)
2
) 10
10 log(
,
PSAFEXT PSAFEXT
total X WP
X WP total
Trang 67Annex F Modeling configurations (informative)
Channel - 100 max.
All dimensions in metres
Permanent link - 90 max.
Trang 68Modular cordunder test
50 50 25
50 50 25
50 50 25
Far end test head
50 50 25
D
C G
test interface
Near end test head
Annex G Modular plug cord test procedure (normative)
Trang 69G.3 Augmented category 6 modular plug cord test procedure
Trang 70G.4.2 Augmented category 6 modular cord test head FEXT loss
20 1 48
Trang 71Annex H Connecting hardware NEXT loss, FEXT loss, return loss, and insertion loss
Trang 72H.3 Modular outlet test considerations
Trang 73H.3.3 Plug direct measurement fixture
Table H.1 - Direct measurement fixture residual NEXT loss and return loss
Direct fixture performance
parameter
Value (dB)
Pair-to-pair residual NEXT loss > 80 (TBD) – 20log(f/100) Return loss > 35 (TBD) – 20log(f /100)
Trang 74H.3.5 Procedure for terminating a test plug to direct measurement test head
Trang 75H.3.6 Augmented category 6 modular test plug NEXT loss requirements
Limit NEXT loss magnitude limit
Case 1 3,6-4,5 Low ≤ 38-20log(f/100) TBD (-90 + 1.5 f /100) ± f /100
TBD Case 2 3,6-4,5 Central (38.8 ± 0.2)-20log(f /100) TBD (-90 + 1.5 f /100) ± f /100
TBD Case 3 3,6-4,5 High ≥ 39.5-20log(f /100) TBD (-90 + 1.5 f /100) ± f /100
TBD Case 4 1,2-3,6 Low ≤ 46.5-20log(f /100) TBD (-90 + 1.5 f /100) ± 3 f /100
TBD Case 5 1,2-3,6 High ≥ 49.5-20log(f /100) TBD (-90 + 1.5 f /100) ± 3 f /100
TBD Case 6 3,6-7,8 Low ≤ 46.5-20log(f /100) TBD (-90 + 1.5 f /100) ± 3 f /100
TBD Case 7 3,6-7,8 High ≥ 49.5-20log(f /100) TBD (-90 + 1.5 f /100) ± 3 f /100
TBD Case 8 1,2-4,5 Low ≤ 57-20log(f /100) TBD 90 ± (30 f /100) TBD Case 9 1,2-4,5 High ≥ 70-20log(f /100) TBD any phase
Case 10 4,5-7,8 Low ≤ 57-20log(f /100) TBD 90 ± (30 f /100) TBD Case 11 4,5-7,8 High ≥ 70-20log(f /100) TBD any phase
Case 12 1,2-7,8 Low ≤ 66-20log(f /100) TBD any phase
1) Magnitude limits apply over the frequency range from 10 to 500 MHz
2) Phase limits apply over the frequency range from 50 to 500 MHz
3) When the measured plug NEXT loss is greater than 70 dB, the phase limit does not apply 4) When a low limit NEXT loss calculation results in values greater than 70 dB, there shall be no low limit for NEXT loss
5) When a high limit NEXT loss calculation results in values greater than 70 dB, the high limit NEXT loss shall revert to a limit of 70 dB
14
Trang 76When testing a particular pair combination, the de-embedded test plug NEXT loss performance for
combination NEXT loss magnitude range 1),4),5) NEXT loss phase range 2),3)
3,6-4,5 38.0-20log(f/100) TBD ≤ NEXT loss ≤
TBD
(-90 +1.5f/100) ± 3f/100 TBD
3,6-7,8 46.5-20log(f/100) ≤ NEXT loss ≤ 49.5-20log(f/100)
TBD (-90 +1.5f/100) ± 3f/100 TBD 1,2-4,5 7) NEXT loss ≥ 57-20log(f/100) TBD 90 ± (30f/100) 6) TBD 4,5-7,8 7) NEXT loss ≥ 57-20log(f/100) TBD 90 ± (30f/100) 6) TBD 1,2-7,8 NEXT loss ≥ 66-20log(f/100) TBD Any phase
1) Magnitude limits apply over the frequency range from 10 MHz to 250 MHz
2) Phase limits apply over the frequency range from 50 MHz to 250 MHz
3) When the measured plug NEXT loss is greater than 70 dB, the phase limit does not apply 4) When a high limit NEXT loss calculation results in values greater than 70 dB, there shall be
no high limit for NEXT loss Refer to Table H.2 for an explanation of the high limit
5) When a low limit NEXT loss calculation results in values greater than 70 dB, the low limit shall revert to 70 dB Refer to table H.2 for an explanation of the low limit
6) When the NEXT loss magnitude exceeds 70 – 20 log (f/100), the phase requirement does not apply
7) The requirements for 1-2,4-5 and 4,5-7,8 do not exclude plugs that meet cases 9 and 11, respectively, shown in table H.2, because such plugs are acceptable for field tester adapters