26 1.5 8630 Smart Router and 8660 Smart Router Applications Software Compatibility Matrix.... 8600 Smart RoutersBoot and Mini-ApplicationsEmbedded Software Release Notes76.8600-50108 Pro
Trang 18600 Smart Routers SR7.0 Embedded Software Release Notes
76.8670-50177B 19.05.2015
Trang 2Document Information
Revision History Document No.
Date Description of Changes
50177B
76.8670-19.05.2015 New application software version for SR7.0 SP1 GA in chapter
12.1 Version SR7.0 SP1 GA (Application SW Version 7.0.172)
8665 Smart Router added to the scope of the document
Ch.1 Embedded Software Interrelation Tablesupdated
Ch 2 Supported Upgrade Pathsupdated
Note regarding 8615 Smart Router boot and mini-application upgradeadded to ch 3 Software Upgrade Orderand5.2 Upgrade RelatedNotifications for 8615 Smart Router
The last sentence added to Step 6 in ch 6.1 8611 Smart RouterService Affecting Hardware and Software Upgrade of the Whole NE.Step 13 added to ch.8.1 Upgrading CDC1 to CDC2
Ch.7 Non-Service Affecting Software Upgradeadded
Ch.14 Restrictions in 8600 Smart Routers SR7.0added
Ch.15 Restrictions in 8600 Smart Routersreorganized
Ch BGP Labeled Unicast (S-MPLS) removed from ch.
15 Restrictions in 8600 Smart Routers The restrictions previously
listed in the chapter are now discussed in 8600 Smart Routers MPLS Configuration Guide.
Added as known bugs since the previous, SR7.0 CIR1, ESW ReleaseNotes: cq300240667, cq300253544, cq300254046, cq300254432,cq300254475, cq300254704, cq300255453, cq300255466,cq300255504, cq300255513, cq300255768, cq300255844,cq300256215, cq300256432, cq300256561, cq300256576,cq300256607, cq300256619, cq300256793, cq300256900,cq300257006, cq300257042, cq300257073, cq300257126,cq300257150, cq300257154, cq300257278, cq300257287,cq300257358, cq300257373, cq300257393, cq300257423,cq300257427, cq300257442
50177A 11.03.2015 Initial version of the document for 8600 Smart Routers SR7.0 CIR1(8602 Smart Router FP7.0 CIR1) ESW version 7.0.92
2
Trang 3This revision of the manual documents the following network elements and the correspondingfeature pack.
© 2015 Coriant All rights reserved.
This manual is protected by U.S and international copyright laws, conventions and treaties Your right to use this manual is subject to limitations and restrictions imposed by applicable licenses and copyright laws Unauthorized reproduction, modification,
distribution, display or other use of this manual may result in criminal and civil penalties.
The specifications and information regarding the products in this manual are subject to change without notice All statements, information, and recommendations in this manual are believed to be accurate but are presented without warranty of any kind,
express or implied Users must take full responsibility for their application of any products.
Adobe ® Reader ® are registered trademarks of Adobe Systems Incorporated in the United States and/or other countries Unless otherwise agreed in a written document, the software in the product is licensed under the license terms found athttp://coriant.com/legal/documents/coriant_tandc_global_deliverables.pdfand
http://coriant.com/legal/documents/tellabs_product_specific_tandc.pdf.
3
Trang 48600 Smart Routers SR7.0 76.8670-50177B
4
Trang 5Document Information
Terms and Abbreviations
CIR Controlled Introduction Ready
CDC Control and DC Power Card (used in 8630 Smart Router and 8660 Smart Router)Control card The control card in the 8600 system consists of a Control and DC Power Card CDC
(used in 8630 Smart Router and 8660 Smart Router), Switching and Control ModuleSCM (used in 8611 Smart Router) In 8000 Intelligent Network Manager and CLIreferred to as unit
CU Control functionality (used in 8615 Smart Router and 8665 Smart Router)ELC1 Ethernet Line Card (used in 8630 Smart Router and 8660 Smart Router)
IFC Interface Module Concentrator is a line card baseboard and it can be equipped with
one or two IFMs There are three variants available: IFC1-A, IFC1-B and IFC2-B(used in 8630 Smart Router and 8660 Smart Router)
IFM Interface Module A specific term of the module which can be placed on the IFC line
card or 8620 Smart Router baseboard and which consists of the physical interfaces(used in 8620 Smart Router, 8630 Smart Router and 8660 Smart Router)
INM 8000 Intelligent Network ManagerLine card The line card in the 8600 system consists of an Ethernet Line Card (ELC1), Interface
Module Concentrator (IFC) and up to two Interface Modules (IFMs) (used in 8630Smart Router and 8660 Smart Router) In 8000 Intelligent Network Manager andCLI referred to as unit
Line Unit The line unit in the 8665 Smart Router is the basic building block for the element
One line unit contains traffic functionality (LU) and control functionality (CU)
LM Line module (used in 8607 Smart Router, 8609 Smart Router and 8611 Smart Router)
LU Traffic functionality (used in 8615 Smart Router and 8665 Smart Router)LU1 Line Unit in 8665 Smart Router
Trang 7Table of Contents
Table of Contents
About This Manual 11
Objectives 11
Audience 11
8600 Smart Routers Technical Documentation 12
Documentation Feedback 15
8600 Smart Routers Discontinued Products 16
1 Embedded Software Interrelation Tables 17
1.1 8600 Boot and Mini-Applications Software 18
1.2 8602 Smart Router Applications Software Compatibility Matrix 24
1.3 8609 Smart Router Applications Software Compatibility Matrix 24
1.4 8615 Smart Router Applications Software Compatibility Matrix 26
1.5 8630 Smart Router and 8660 Smart Router Applications Software Compatibility Matrix 28
1.6 8665 Smart Router Applications Software Compatibility Matrix 33
2 Supported Upgrade Paths 35
3 Software Upgrade Order 38
4 Operations Before Upgrade 39
4.1 Operations Before Upgrading 8602 Smart Router and 8609 Smart Router 39
4.2 Operations Before Upgrading 8611 Smart Router 40
4.3 Operations Before Upgrading 8615 Smart Router and 8665 Smart Router 41
4.4 Operations Before Upgrading 8630 Smart Router and 8660 Smart Router 42
5 Upgrade Related Notifications 44
5.1 Upgrade Related Notifications for 8609 Smart Router and 8611 Smart Router 44
7
Trang 8Table of Contents
5.1.1 Recommended Procedure for Upgrading to 8609 Smart Router and 8611 Smart Router FP1.3 SP1 44
5.2 Upgrade Related Notifications for 8615 Smart Router 44
5.3 Upgrade Related Notifications for 8630 Smart Router and 8660 Smart Router 45
5.3.1 Notification Regarding ELC1 ESW Upgrade to 8630 Smart Router and 8660 Smart Router FP4.1 SP1 45
6 Service Affecting Software Upgrade of the Whole NE 46
6.1 8611 Smart Router Service Affecting Hardware and Software Upgrade of the Whole NE 48
7 Non-Service Affecting Software Upgrade 50
7.1 8611 Smart Router Non-Service Affecting Software Upgrade 50
7.2 8630 Smart Router and 8660 Smart Router Non-Service Affecting Software Upgrade 51
8 Upgrading Cards 55
8.1 Upgrading CDC1 to CDC2 55
8.2 IFC1 to IFC2 Upgrade 58
8.2.1 Service Affecting Upgrade of IFC1 to IFC2 59
8.2.2 Non-Service Affecting Upgrade of IFC1 to IFC2 61
9 ESW Upgrade with Downgrade Support for 8602 Smart Router and 8615 Smart Router 62
10 Restoring Previous FP and Configuration in Case of Upgrade Failure 64
10.1 Restoring Previous FP and Configuration in Case of Upgrade Failure in 8602 Smart Router and 8609 Smart Router 64
10.2 Restoring Previous FP and Configuration in Case of Upgrade Failure in 8611 Smart Router, 8615 Smart Router, 8630 Smart Router, 8660 Smart Router and 8665 Smart Router 65
11 SR7.0 Features 67
12 Application Software 69
12.1 Version SR7.0 SP1 GA (Application SW Version 7.0.172) 69
8
Trang 9Table of Contents
13 Enhancements and Fixed Bugs in SR7.0 SP1 71
13.1 Control, Routing and Signaling Protocols 71
13.1.1 Enhancements 71
13.1.2 Fixed Bugs 71
13.2 Ethernet Forwarding and Services 73
13.2.1 Fixed Bugs 73
13.3 IP/MPLS Forwarding and Services 74
13.3.1 Enhancements 74
13.3.2 Fixed Bugs 74
13.4 Management Plane 76
13.4.1 Fixed Bugs 76
13.5 Multiservice 76
13.5.1 Fixed Bugs 76
13.6 Platform Services 77
13.6.1 Enhancements 77
13.6.2 Fixed Bugs 77
13.7 Resiliency and Robustness 78
13.7.1 Fixed Bugs 78
13.8 Synchronization 78
13.8.1 Enhancements 78
13.8.2 Fixed Bugs 79
13.9 Traffic Management 81
13.9.1 Fixed Bugs 81
13.10 Troubleshooting, OAM, Statistics and Performance Monitoring 81
13.10.1 Fixed Bugs 81
13.11 Other 82
13.11.1 Fixed Bugs 82
14 Restrictions in 8600 Smart Routers SR7.0 84
14.1 Control, Routing and Signaling Protocols 84
14.2 Ethernet Forwarding and Services 84
15 Restrictions in 8600 Smart Routers 85
15.1 General 85
15.2 Synchronization 85
15.3 Product Specific Restrictions in 8600 Smart Routers 86
15.3.1 8602 Smart Router 86
15.3.2 8609 Smart Router and 8611 Smart Router 86
15.3.3 8615 Smart Router 86
15.3.4 8630 Smart Router and 8660 Smart Router 87
16 Known Bugs 88
16.1 Control, Routing and Signaling Protocols 88
16.2 Ethernet Forwarding and Services 88
9
Trang 10Table of Contents
16.3 IP/MPLS Forwarding and Services 91
16.4 Management Plane 94
16.5 Platform Services 94
16.6 Resiliency and Robustness 96
16.7 Synchronization 97
16.8 Traffic Management 97
16.9 Troubleshooting, OAM, Statistics and Performance Monitoring 98
16.10 Other 99
17 Rejected Bugs 101
10
Trang 11About This Manual
About This Manual
This chapter discusses the objectives and intended audience of this manual, 8600 Smart Routers
Embedded Software Release Notes.
Features introduced in 8600 Smart Routers SR7.0 are listed in chapter11 SR7.0 Features
Chapter12 Application Softwaredescribes the enhancements and fixed bugs in the followingapplication software:
• 8602 Smart Router: SBZ2755 Application Software
• 8609 Smart Router: SBZ2751 Application Software
• 8615 Smart Router: CBZ2764 and LBZ2765 Application Software
• CDC1: CBZ2712 Application Software
• CDC2: CBZ2745 Application Software
• ELC1: LBZ2754 Application Software
• IFC1: LBZ2713 Application Software
• IFC2: LBZ2741 Application Software
• 8665 Smart Router: CBZ2759, XBZ2761 and LBZ2763 Application Software
The known restrictions are listed in chapters14 Restrictions in 8600 Smart Routers SR7.0and
15 Restrictions in 8600 Smart Routers.Chapter16 Known Bugslists the open issues in 8600 Smart Routers SR7.0
Trang 12About This Manual
8600 Smart Routers Technical Documentation
The document numbering scheme consists of the document ID, indicated by numbers, and thedocument revision, indicated by a letter The references in the Related Documentation table beloware generic and include only the document ID To make sure the references point to the latestavailable document versions, please refer to the relevant product document program on the Tellabsand Coriant Portal by navigating towww.portal.tellabs.com> Product Documentation & Software
> Data Networking > 8600 Smart Routers > Technical Documentation
8600 Smart RoutersATM and TDM Configuration Guide(76.8600-50110)
Provides an overview of 8600 NEs PWE3 applications,including types, Single-Segment and Multi-Segment; PWE3Redundancy; ATM applications, including PWE3 tunnelling,Traffic Management, Fault Management OAM, protection andTDM applications as well as instructions on how to configurethem with CLI
8600 Smart RoutersBoot and Mini-ApplicationsEmbedded Software Release Notes(76.8600-50108)
Provides information related to the boot and mini-applicationssoftware of 8605 Smart Router, 8607 Smart Router, 8609Smart Router, 8611 Smart Router, 8620 Smart Router, 8630Smart Router and 8660 Smart Router as well as the installationinstructions
8600 Smart RoutersCLI Commands Manual(76.8600-50117)
Provides commands available to configure, monitor and maintain
8600 system with CLI
8600 Smart RoutersEmbedded Software Release Notes
8600 Smart Routers SR7.0 Embedded Software Release Notes(76.8670-50177) for the following products:
Provides an overview of 8600 system HW inventory, softwaremanagement, equipment protection 1+1 (CDC and SCM) as well
as instructions on how to configure them with CLI
8600 Smart RoutersEthernet Configuration Guide (76
8600-50133)
Provides an overview of 8600 system Ethernet applications,including interfaces; Ethernet forwarding (MAC Switching,Ethernet PWE3, IRB, VLAN, VPLS); Ethernet OAM; LAG;ELP as well as instructions on how to configure them with CLI
8600 Smart Routers Smart RoutersFault Management ConfigurationGuide (76.8600-50115)
Provides an overview of 8600 system fault management,including fault source, types and status as well as instructions onhow to configure it with CLI
8600 Smart RoutersFrame Relay Configuration Guide(76.8600-50120)
Provides an overview of 8600 system Frame Relay applications,including interfaces; Performance Monitoring; protection; TrafficManagement as well as instructions on how to configure themwith CLI
8600 Smart RoutersHardware Installation Guide(76.8600-40039)
Provides guidance on mechanical installation, cooling,grounding, powering, cabling, maintenance, commissioning andESW downloading
12
Trang 13About This Manual
8600 Smart RoutersInterface Configuration Guides The Interface Configuration Guides provides an overview of the8600 NEs interface functions, including NE supported interface
types and equipping; interface features; configuration options andoperating modes; fault management; performance monitoring;interface configuration layers and port protocols as well asinstructions on how to configure them with CLI The followinginterface configuration guides are available:
• 8600 Smart Routers Network Interfaces ConfigurationGuide (76.8600-50161) (for 8602 Smart Router, 8615 SmartRouter and 8665 Smart Router)
• 8609 Smart Router and 8611 Smart Router FP7.0 InterfaceConfiguration Guide (76.8670-50179)
• 8600 Smart Routers FP7.0 Interface Configuration Guide(76.8670-50180) (for 8630 Smart Router and 8660 SmartRouter)
8600 Smart Routers
IP Forwarding and TrafficManagement Configuration Guide(76.8600-50122)
Provides an overview of 8600 NEs IP, forwarding and trafficmanagement functionality, including: IP addressing; IP hosting(ARP, DHCP); IP routing (static); ACL; Differentiated Services(Policing, Queue Management, Shaping) as well as instructions
on how to configure them with CLI
8600 Smart RoutersManagement CommunicationsConfiguration Guide
(76.8600-50125)
Provides an overview of 8600 system managementcommunications functions, including communication protocols:BMP; FTP; RADIUS; SNMP; SSH; TELNET as well asinstructions for configuring them with CLI
8600 Smart RoutersMobile Optimization ConfigurationGuide (76.8600-50100)
Provides an overview of 8600 system Mobile Optimizationapplications as well as instructions on how to configure themwith CLI
8600 Smart RoutersMPLS Applications ConfigurationGuide (76.8600-50123)
Provides an overview of 8600 NEs MPLS applications (includingFRR (one-to-one and facility backup); LDP; protection andTraffic Engineering), MPLS-TP applications (including OAM,linear protection), S-MPLS applications as well as instructions
on how to configure them with CLI
8600 Smart RoutersPerformance Counters ReferenceGuide (76.8600-50143)
Provides an overview of 8600 system supported performancecounters
13
Trang 14About This Manual
8600 Smart RoutersReference Manuals The reference manuals describe the 8600 network elementfeatures including:
• NE enclosure, baseboard, power supply modules, andinterfaces in 8602 Smart Router FP7.0 Reference Manual(76.8670-40130)
• NE enclosure, baseboard, power supply modules, interfacesand physical LM types in 8609 Smart Router FP7.0 Refer-ence Manual
• NE enclosure, baseboard, power supply modules, SCMs, HMand LM types in 8611 Smart Router FP7.0 Reference Manual
• NE enclosure, baseboard, power supply modules, and terfaces in 8615 Smart Router FP7.0 Reference Manual(76.8670-40132)
in-• NE subrack, fan modules, CDCs, line cards and IFMs in 8630Smart Router FP7.0 Reference Manual
• NE subrack, fan modules, CDCs, line cards and IFMs in 8660Smart Router FP7.0 Reference Manual
• NE subrack, fan modules, line unit and switch unit in 8665Smart Router FP7.0 Reference Manual (76.8670-40128)
8600 Smart RoutersRouting Protocols ConfigurationGuide (76.8600-50121)
Provides an overview of 8600 NEs routing protocols, includingBFD; BGP; BGP MP; ECMP; IS-IS; OSPF and VRRP as well asinstructions on how to configure them with CLI
8600 Smart RoutersScalability Reference Manual(76.8600-50160)
Provide a summary of tested scalability limits of the 8600 SmartRouters
8600 Smart RoutersSNMP MIB Support(76.8600-50116)
Describes SNMP MIB support by the 8600 NEs and providesinformation on the supported objects and traps For furtherinformation on SNMP MIBs, see the related RFCs
8600 Smart RoutersStatistic Counters Reference Guide(76.8600-50142)
Provides an overview of 8600 system supported statistic counters
8600 Smart RoutersSynchronization ConfigurationGuide (76.8600-50114)
Provides an overview of 8600 NEs synchronization functionality,including physical layer Frequency Synchronization (SEC, EEC);PTP Frequency Synchronization; Phase-Time Synchronization(L2 and L3 applications) as well as instructions on how toconfigure them with CLI
8600 Smart RoutersTest and Measurement ConfigurationGuide (76.8600-50124)
Provides an overview of 8600 NEs measurement and connectivityverification tools, including Ethernet loopback; IP ping andtraceroute; MAC swap loopback; MPLS ping and traceroute;PLT; PWE3 loopback; VCCV (BFD, LSP ping) as well asinstructions on how to configure them with CLI
8600 Smart RoutersVPNs Configuration Guide(76.8600-50128)
Provides an overview of 8600 system virtual private network(VPN) layer 3 applications as well as instructions on how toconfigure them with CLI
8000 Intelligent Network ManagerOnline Help Provides instructions on how different operations are performedwith the 8000 Intelligent Network Manager Describes also
different parameters and controls of the 8000 Intelligent NetworkManager dialogs and windows
Note that the Online Help is not available on the Portal but it isincorporated in the 8000 Intelligent Network Manager
14
Trang 15About This Manual
Trang 168600 Smart Routers Discontinued Products
8600 Smart Routers Discontinued Products
8600 Smart Routers Manufacture Discontinued (MD) notifications are available on the Tellabsand Coriant Portal,www.portal.tellabs.com > Product Documentation & Software > Data Networking > [8600 Smart Router product name] > Product Notifications.
16
Trang 171 Embedded Software Interrelation Tables
1 Embedded Software Interrelation Tables
The following embedded software interrelation tables are shown below:
• Boot software and mini-application used in 8600 For a comprehensive list of software
ver-sions, please refer to 8600 Smart Routers Boot and Mini-Applications Embedded Software
The following conventions are used in the release notes
• The text No known bugs means that there are no bugs known to Coriant.
• The text No known restrictions under version information means that there are no restrictions
when using this version of software or hardware
The notations used in the rows of the network element dependencies and compatible networkelements and embedded software versions are explained in the following table
Version number A specific ESW version is required
A particular NE or SW is not required or supported byanother NE
Rows marked in bold indicate the latest HW or SW product generally available and in production.
Rows marked in italics indicate the fast lane or CIR products that are not generally available The older generally available HW and SW versions are in normal font type.
17
Trang 181 Embedded Software Interrelation Tables
The meaning of different columns and notations are described below
Baseboard Baseboard where the ESW is downloaded
HW Version Hardware version of the baseboard
ESW Version Embedded software version whose dependencies are
described in that row Also the Service Pack mentioned.Production Status Production status of the embedded software version whose
dependencies are described in that row The productionstatus can be
• GA: refers to a generally available version that is in
production
• CIR: refers to a first customer shipment version of the
software that is intended for controlled introduction.This version should not be used by customers after thegeneral availability of the software has been reachedand a new version is available
• Fast lane: refers to a version of software with a limited
distribution released to fix a potentially critical lem that is typically impacting only a small number ofcustomers This version can be obtained by contactingCoriant technical support
prob-NE Dependencies ESW dependencies related to a NE
8000 INM Release 8000 Intelligent Network Manager release that supports all
functionality of the product
8000 INM EMS Driver Version 8000 Intelligent Network Manager EMS driver version
related to 8600 NE FP
Interface Module Name of the interface module and HW identification code.Compatible NEs and ESW Versions Compatible NEs and ESW versions for an IFM
Mini-Application Mini-application product name
Mini-Application Version Specifies the oldest software version of mini-application
which co-operates with the given application software,boot software or product HW version For example, a newproduct HW version may require that the mini-applicationhas to be at least this version level due to HW changes.Boot Version Boot SW activates the application or mini-application
software Boot SW must be at least at the minimumspecified level specified by the activated applicationsoftware or mini-application for correct product behavior.Application Version Application software running at product normal operational
state Application, mini-application and boot software haveinternal dependencies where each software version must be
at least at the specified level to co-operate correctly
18
Trang 19Ap-Version 8600
NE/card
board
Base-HW Version
Boot SW Version Application
Version
Production Status
Other Data
Trang 20Version 8600
NE/card
board
Base-HW Version
Boot SW Version Application
Version
Production Status
Other Data
CBZ2745 4.1.259u CDC2-B CBB2300 1.0 or higher GMZ2743 1.16.0 FP4.1 CIR2
or FP4.1 CIR3
CIR
higher
GMZ2711 2.0.104 IFC1-A LBA2024 1.0 or higher GMZ2710 3.3.7 2.8.212 or
Trang 21Version 8600
NE/card
board
Base-HW Version
Boot SW Version Application
Version
Production Status
Other Data
GMZ2711 2.0.104 IFC1-B LBA2225 1.0 or higher GMZ2710 3.3.7 2.8.212 or
Trang 22Version 8600
NE/card
board
Base-HW Version
Boot SW Version Application
Version
Production Status
Other Data
SBZ2748 1.2.303 8611 (SCM) SCM2265
81.86C-8611-R6Rev A orhigher
GMZ2747 1.1.75 8611 (SCM) SCM2265
81.86C-8611-R6Rev A orhigher
Trang 23Version 8600
NE/card
board
Base-HW Version
Boot SW Version Application
Version
Production Status
Other Data
LBZ2765 1.0.86 8615 (LU) SBB2306 1.0 or higher GMZ2758 1.52.0 1.0.103 CIR
CBZ2764 1.0.86 8615 (CU) VID9109 1.0 or higher GMZ2758 1.52.0 1.0.103 CIR
Trang 241 Embedded Software Interrelation Tables
8602 Smart Router Hardware and Software Compatibility Matrix Basic Data
board HW Version ESW ESW Version Production Status
Base-8000 INM Release
8000 INM EMS Driver Version SBB2305 1.0 or
8609 Smart Router Hardware and Software Compatibility Matrix Basic Data
board HW Version ESW ESW Version Production Status
Base-8000 INM Release 8000 INM EMS
Driver Version SBB2284 1.0 or
higher SBZ2751 7.0.172 (SR7.0 SP1) GA SR6.1 or higher 700.0
24
Trang 25Hardware and Software Compatibility Matrix for Switching and Control Module and Physical Line Modules
Down-loadable Firmware
Firmware Version
8609 SBZ2751
8611 SBZ2748
8x10/100BASE-TX LM LME2243
81.86LFETX82243-R6 Rev D
8x10/100BASE-TX LMLME2243 81.86LFETX82243-R6Rev C
8xchE1/chT1 LM LMP2242 81.86LE1T082242-R6 Rev D
8xchE1/chT1 LMLMP2242
4x100/1000BASE-X HM HMG2266 81.86M-HMGE4SFP-R6 Rev A
1x10GBASE-R HM HMX2267 81.86M-HM10GE1-R6 Rev A
Trang 261 Embedded Software Interrelation Tables
26
Trang 278615 Smart Router Hardware and Software Compatibility Matrix
8615 Card
Base-board
HW Version
Status
8000 INM Release
8000 INM EMS Driver Version
Trang 281 Embedded Software Interrelation Tables
Compatibility Matrix
28
Trang 298630 Smart Router and 8660 Smart Router Hardware and Software Compatibility Matrix
8630 /8660 Card
board
Base-HW Ver- sion
Version
tion Status
8000 INM Release
8000 INM EMS Driver Version CDC1-A CBB2026 1.1 or
higher CBZ2712 7.0.172 (SR7.0 SP1) GA 7.0.172 7.0.172 7.0.172 7.0.172 7.0.172 SR6.1 or higher 700.0 CDC1-B CBB2224 1.0 or
Trang 308600 Interface Module Hardware and Software Compatibility Matrix
8x10/100BASE-TX LIE2018
2.2 (81.86MFETX82018-R6 Rev D)
2.2.7 or higher 4.1.322 or higher 2.2.7 or higher —
8x10/100BASE-TXLIE2018 2.1 (81.86MFETX82018-R6Rev C) 2.2.7 or higher 4.1.322 or higher 2.2.7 or higher
8x100BASE-X LIO2028
1.1 (81.86MFEX082028-R6 Rev A)
1.22.7 or higher 4.1.322 or higher 1.22.7 or higher —
8x100BASE-X
—
2x1000BASE-X LIO2019 2.0 (81.86MGE0022019-R5
Rev A) 1.17.36 or higher 4.1.322 or higher 1.17.36 or higher
—
2x1000BASE-X LIO2019 1.0 1.17.15 or higher 4.1.322 or higher 1.17.15 or higher —
8x1000BASE-X LIO2208 2.0 (81.86MGE0082208-R6
Rev B) 1.22.7 or higher 4.1.322 or higher 1.22.7 or higher
—
8x1000BASE-X LIO2208 1.2 1.22.7 or higher 4.1.322 or higher 1.22.7 or higher —8x1000BASE-X LIO2208 1.0 1.22.7 or higher 4.1.322 or higher 1.22.7 or higher —
2+6x10/100/1000 BASE-COMBO LIC2231
1.3 (81.86MGEC082231-R6 Rev C)
2.5.113 or higher 4.1.322 or higher 2.5.113 or higher —
2+6x10/100/1000BASE-COMBOLIC2231
1.2 (81.86MGEC082231-R6Rev B)
2.5.113 or higher 4.1.322 or higher 2.5.113 or higher —
2+6x10/100/1000BASE-COMBOLIC2231
8x10/100/1000BASE-TX R2 LIE2256 81.86M-IFMGET08-R6 Rev A 3.1.309 or higher 4.1.322 or higher
Trang 318x100/1000BASE-X R2 IFM LIO2252
81.86M-IFMGEX08-R6 Rev B
3.0.126 or higher 4.1.322 or higher — 3.0.126 or higher
8x100/1000BASE-X R2IFM LIO2252
1.0(81.86M-IFMGEX08-R6Rev A)
3.0.126 or higher 4.1.322 or higher — 3.0.126 or higher
1x10GBASE-R R2 IFM LIO2257
81.86M-IFM10GS1-R6 Rev B
3.0.126 or higher 4.1.322 or higher — 3.0.126 or higher
1x10GBASE-R R2 IFMLIO2257
1.0(81.86M-IFM10GS1-R6Rev A)
3.0.126 or higher 4.1.322 or higher — 3.0.126 or higher
8xSTM-1/OC-3 POS LIO2020
1.1 (81.86MS1P082020-R6 Rev A)
1.17.15 or higher 4.1.322 or higher 1.17.15 or higher 3.1.309 or higher
8xSTM-1 POSLIO2020
4xSTM-4/OC-12 POS LIO2233 1.0 (81.86MS4P042233-R6 Rev A) 2.7.20 or higher 4.1.322 or higher 2.7.20 or higher 3.1.309 or higher 1xSTM-16/OC-48 POS
LIO2021
1.0 (81.86MS16P12021-R6 Rev A)
1.17.15 or higher 4.1.322 or higher 1.17.15 or higher 3.1.309 or higher
4xSTM-1/OC-3 ATM LIA2210
1.1 (81.86MS1A042210-R6 Rev A)
2.0.2 or higher 4.1.322 or higher 2.0.2 or higher 3.1.309 or higher
4xSTM-1/OC-3 ATMLIA2210
1xchSTM-1/chOC-3 MS LIO2203 1.0 (81.86MS1C012203-R5 Rev B) 2.0.2 or higher 4.1.322 or higher 2.0.2 or higher 3.1.309 or higher 4xchSTM-1/chOC-3 MS
LIO2234
2.0 (81.86MS1C042234-R6 Rev B)
2.9.143 or higher 4.1.322 or higher 2.9.143 or higher 3.1.309 or higher
4xchSTM-1/chOC-3 MSLIO2234
1.1 (81.86MS1C042234-R6Rev A)
2.9.143 or higher 4.1.322 or higher 2.9.143 or higher —
24xchE1/chT1 MS LIE2226
2.1 (81.86ME1T242226-R6 Rev B)
2.7.20 or higher 4.1.322 or higher 2.7.20 or higher 3.1.309 or higher
24xchE1/chT1 MS LIE2226 2.0 2.7.20 or higher 4.1.322 or higher 2.7.20 or higher —
Trang 3224xchE1 MSLIE2226
24xchE1/chT1 MO LIE2237
1.0 (81.86ME1M242237-R6 Rev A)
2.9.242 or higher 4.1.322 or higher 2.9.242 or higher —
Trang 331 Embedded Software Interrelation Tables
33
Trang 348665 Smart Router Hardware and Software Compatibility Matrix
8665 Card
board
Base-HW Ver- sion
Produc-tion tus
8000 INM Re- lease
8000 INM EMS Driver Ver- sion LU1 ELC2314 1.0 or
Trang 352 Supported Upgrade Paths
2 Supported Upgrade Paths
The supported upgrade paths are listed in the tables below See also ch 5 Upgrade RelatedNotifications
Trang 362 Supported Upgrade Paths
Trang 372 Supported Upgrade Paths
Trang 383 Software Upgrade Order
3 Software Upgrade Order
Boot and mini-application software should be updated only if there is a real need to do it, e.g.:
• Mini- or application SW release notes say mini-application upgrade is mandatory or
• There is some other customer related reason for update, e.g a new feature or bug fix in newermini-application is needed
When upgrading both the application software and the boot and mini-application software in
8602 Smart Router and 8609 Smart Router, it is recommended that the application software is upgraded first.
8615 Smart Router needs the latest boot and mini-application software if the network element is going to be used in stacked configuration See the table in ch 1.1 8600 Boot and Mini-Applications Software
For 8615 Smart Router stacked, the boot and mini-application software should be upgraded before the application software.
For all the CDC2-B control cards delivered before FP4.1 SP1, CDC2 boot software GMZ2743 version 1.20.0 or higher needs to be updated before upgrading the application ESW to FP4.1 SP1.
Check the current boot SW version in slot 1 and 14 E.g.:
router#show sw-version slot 1
See the Boot and Mini-Application Upgrade chapter for installation instructions in 8600 Boot and
Mini-Applications Embedded Software Release Notes.
If you are currently using application ESW FP2.11A SP1 in 8630 Smart Router and 8660 Smart Router, the boot and mini-application upgrade is optional in CDC1, IFC1, IFC2 and ELC1 cards and should be done after upgrading the application ESW to FP2.11A SP2 or higher.
38
Trang 394 Operations Before Upgrade
4 Operations Before Upgrade
Prior to upgrading, validate that the network element is ready for upgrade by performing the stepsoutlined below, which are common for all 8600 Smart Routers
• Check and record the state of the NE before starting the upgrade
• Free flash space by removing the previous unused ESWs
• Free flash space by removing the old unused configuration snapshot files in each slot
• Backup the current configuration of the NE
Router
Note that 'x.y.z' in the examples below refers to the relevant ESW version number
Step 1 Check and record the state of the NE before starting the upgrade Check the hardware inventory and
verify that the NE is in up-and-running state and check the ESW version
router# show hw-inventory | include slotrouter# show sw-version | include OK
If problems are found:
• Consider if they need to be fixed before starting the upgrade, or
• Consider using the "force" option when activating the new ESWrouter(config)# boot system <…> backup-config forceUsing this option the upgrade is forced; the previous ESW or configurations will not beautomatically restored (but the upgrade can still be canceled manually)
Step 2 Free flash space by removing the previous unused ESWs:
Step 3 Free flash space by removing the old unused configuration snapshot files in each slot Before
deleting make backup copies by uploading the configuration snapshot files from the network elementusing FTP The snapshot files can be found in the following directory:
/flash/snapshot-config/
This CLI command will give a list of the already created and stored snapshots:
To get more details regarding a specific snapshot use the following CLI command:
router# show snapshot-config flash: <filename>
Delete unused snapshot files:
router# snapshot-config delete flash: <filename>
39
Trang 404 Operations Before Upgrade
Step 4 Backup the current configuration of the NE:
router# snapshot-config create flash: <filename> description
<x.y.z>
The current configuration and running config text file will be stored in the snapshot file:
router# snapshot-config create flash: <filename>
running-config description <x.y.z>
Note that in 8611 Smart Router the working slot (primary) is slot 2
Note that 'x.y.z' in the examples below refers to the relevant ESW version number
Step 1 Check and record the state of the NE before the upgrade is started Check the hardware inventory
and verify that all cards are present, in up-and-running state and all cards are running the sameESW version
router# show hw-inventory | include slotrouter# show sw-version | include OK
If problems are found:
• Consider if they need to be fixed before starting the upgrade, or
• Consider using the "force" option when activating the new ESWrouter(config)# boot system <…> backup-config forceUsing this option the upgrade is forced; the previous ESW or configurations will not beautomatically restored (but the upgrade can still be canceled manually)
Step 2 Free flash space by removing the previous unused ESWs:
Step 3 Free flash space by removing the old unused configuration snapshot files in each slot Before
deleting make backup copies by uploading the configuration snapshot files from the network elementusing FTP The snapshot files can be found in the following directory:
/flash/snapshot-config/slot<slot#>/
This CLI command will give a list of the already created and stored snapshots:
The “show snapshot” CLI command can also contain the slot number part If it is omitted, the slotnumber of the active SCM is used by default
To get more details regarding a specific snapshot use the following CLI command:
router# show snapshot-config flash: <filename>
Delete unused snapshot files:
router# snapshot-config delete slot 2 flash: <filename>
3 Note that 8611 Smart Router is not supported in 8600 Smart Routers SR7.0 SP1.
40