Color Matching CabinetColor Matching Cabinet booth for visual assessment of color under 6 standard lights, folding body and button switch.. Suitable for staining, change in color test by

Trang 1

Color matching Cabinet

Trang 2

Color Matching Cabinet

Color Matching Cabinet booth for visual assessment of color under 6 standard lights,

folding body and button switch Suitable yarn, fabric dyeing plant, garment manufacturer Suitable for staining, change in color test by using grey scales during color fastness test

Trang 3

The most accurate Color Viewing Cabinet(Light box, Light cabinet, Color box) to compare, matching and communicate color with absolute

confidence Our standard sizes of the Color viewing cabinet will

accommodate nearly any sample size (and if not, larger custom sizes are available

Object:

Trang 4

• Color looks different under different lighting condition When one uses a Color

Matching Cabinet it helps in marking the difference Color Viewing Cabinets is

equipped with most accurate light cabinet for visual evaluation of fabrics, garment, cloth, textiles, and leathers and so on It checks matching under a standard light source

in a closed environment to minimize the interference of external lights

• Color Matching Cabinet booth is used for visual assessment of color under 6 standard lights and comes with doors Color Matching Cabinet, Light Box, is suitable for yarn, fabric dyeing plant, and garment manufacturer and exporters Suitable for staining, change in color test by using grey scales during color fastness test

Color Matching Cabinet measures the color difference between two samples.

Trang 5

1 Cabinet is made of Teakwood, Ply Board & Sun mica, with strict adherence to international standards.

2 Supplied with major tube lights & bulbs for quick and accurate color assessment

3 Fitted with Electronic/ballasts for Instant start & power saving to safeguard the expensive & sensitive tube lights & bulbs

4 No warm-up; No flick; No heat emission; Elapsed Time displaying of each light source

5 Energy saving; Efficient illumination

6 Compact; High quality with low price

7 Button Switches

Features of Color Matching Cabinet:

Trang 6

• Overall Dimensions of the Instrument : 710±10 (L) x 414±10

(W) x 628±10 (H) mm

• Overall Dimensions of the Viewing Cavity : 685±10 (L) x

408±10 (W) x 380±10 (H) mm Net Weight of the Instrument :

25.480 Kg.

Specifications of Color Matching Cabinet:

Trang 7

• Artificial Daylight Fluorescent Lamps (D-65) : 01 Nos (18 W)

• Tungsten Filament Lamps : 04 Nos (40 W) Cool White

• Fluorescent Lamp (CWF) : 01 No (18 W) Triphosphor

• Fluorescent Lamp (TL-84) : 01 No (18 W) Ultra-Violet Black

• Lamp : 01 No (8 W) Warm White : 01 No (18 W)

Light Sources

Trang 8

Light Source

The most used norm lights are:

D65 : Average daylight with a color temperature of 6500 K

A : Tungsten light with a color temperature of 2856 K

TL84 : Fluorescent lamps with a color temperature of 4000 K

CWF : Fluorescent lamps with a color temperature of 4230 K

Trang 9

Light Source Name Description C.R.I Length

D65

VeriVide D65

"Artificial Daylight

VeriVide D65 “Artificial Daylight” Correlated colour temperature 6500K Within the tolerances prescribed in BS 950: Part 1; and all international specifications for D65 illuminant Specified for most applications where there is a need to maintain colour consistency and quality

Conforming highly to the CIE specifications, for accurate colour matching.

98

600mm 1200mm 1500mm

20w 40w 65w

F

Tungsten Filament

Tungsten Filament Lighting Approximate colour temperature of 2800K Required by BS 950: Part 1

as a test for metamerism (approximating CIE Illuminant ‘A’) Typical light source used within domestic environments

100

Globe Globe Round Clear- 284mm Opal-284

40w 60w 150w 60w 60w

A

Tungsten Halogen

Tungsten Halogen Lighting (CIE Illuminant ‘A’) This represents incandescent A (inc-A) with a color temperature of 2856K Typical light source used within domestic environments Used to check for metamerism.

100

- 35w

Trang 10

Light Source Name Description C.R.I Length

Spencer (Formerly TL84)

1200mm1500mm

18w36w58w

CWF

Cool White Cool White Broad Band Fluorescent

Lamps Correlated colour temperature

of 4000K Used as an American “Point of Sale” light source Moderate colour rendering

1200mm1500mm

20w40w65/80w

Trang 11

Light

Source

830

Narrow Band Triphosphor Fluorescent Lamp

Correlated colour temperature 3000K Often chosen as a European “Point of Sale” light source with good colour rendering.(Formerly TL83)

85

600mm1200mm1500mm

18w40w65/80w

UV

Ultra Violet

Ultra-Violet Black light Used to detect the presence of Optical Brightening Agents and/or Fluorescent dyes Therefore it is useful when assessing white and Fluorescent shades to check the level present and its evenness

N/A

450mmBlacklight-600mm

Clear-15w18w

Trang 12

Color Matching Cabinet Confirms with following international standards:

Trang 13

1 The equipment offers a wide viewing area equipped with multiple light

sources or lamps to detect the phenomenon of Metamerism, where

samples appear to match under one light source but is distinctly different under another In order to reach the final approval the fabric has to go through various light sources which include: artificial daylight, cool white light, tungsten filament light, ultra violet black light, triphosphor

fluorescent light.

2 The sample to be tested and the original sample are to be kept in the

viewing cavity.

3 After switching on the D-65 Light closely check the original specimen and

the specimen to be tested.

How Color Matching Cabinet works?

Trang 14

• When the match is satisfactory, the specimen is to be tested under CWF Light and TFL Lamps.

• Now the test is carried out under U.V.B Light, it is necessary to ascertain if both samples react equally to Ultra Violet radiation

• Then the final test is carried out under TL-84 Philips Triphosphor Fluorescent lamp tube light is carried to ascertain if the colors are acceptable at the ‘Point of Sale’

• All these help in judging the color differences accurately, by comparing the

samples in different conditions When the match of both samples holds well under all the lights, it means that the Dyeing, Printing and the coloring of the fabric or yarn is as per the requirement

How Color Matching Cabinet works?

Trang 15

Color matching booths and visual color

matching

• The nature and intensity of the light source.

• The angle of illumination and viewing the samples.

• The color of the surrounds and the sample back ground.

• The size and distance apart of the samples.

• The state of adaptation of the observer.

• The observer’s color vision characteristics.

• An agreement on the color-difference term to be used.

Trang 16

Matching booth design

• The lamps are placed in a recess directly above the matching surface, preferably behind a frosted glass cover and/or filter glass which provides reasonably diffuse illuminant.

• The matching surface and the interior of the

matching booth should be painted a light grey (about 30% reflectance).

• The booth placed at height such that the viewing

angle for the observer of average stature is

approximately 45o.

Trang 17

Rules of visual examination.

• Place the specimens in immediate juxtaposition and should be interchanged to avoid any bias in viewing them.

• Keep intensity of illuminant high.

• Have the background similar to the specimens.

• Have the illumination spectrally representative of that normally employed in critical commercial

studies, usually actual or artificial day light

Trang 18

Figure: Light box & viewed angle

Trang 19

Brand name: VeriVide

Company name: James H Heal

Origin: UK

Purpose: Sample is examined under different lighting media

Trang 20

Datacolor Color Matcher Light Booth

Trang 21

Fig: lauder meter (color fastness tester) Model: G210/60

Trang 22

D 65

Trang 23

Tungsten light

Trang 24

Ultraviolet Neon Lights

Trang 25

Fluorescent light

Trang 26

COOL White Fluorescent light

Trang 28