1. Trang chủ
  2. » Công Nghệ Thông Tin

CompTIA Network+ Certification Study Guide part 9 pptx

10 419 0
Tài liệu đã được kiểm tra trùng lặp

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Tiêu đề Network Media
Trường học CompTIA
Chuyên ngành Network+ Certification
Thể loại study guide
Định dạng
Số trang 10
Dung lượng 85,83 KB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

Although Ethernet runs on either coaxial or twisted-pair, and Fast Ether-net runs on pair cable, Gigabit EtherEther-net uses fiber-optic or twisted-pair cabling to transmit data.. As wit

Trang 1

ChApTEr 2: Network Media

66

When connecting twisted-pair wire to an RJ-45 connector, the wires will have to be aligned so that they match up with the pins of the connector Table 2.4 shows how the various wires of a four pair cable are installed

Cable Installation

When installing cable, you first need to choose the location of the hub, switch, or router These devices will be where the cable will attach to, and as we’ll see in the next chapter, are used to move data from one cable to another

so it reaches its intended destination In larger organizations a patch panel

or cabinet may be used to accommodate numerous cables, or a separate hub, switch, or router will be used for each floor of a building Using one of these devices on each floor will save time and require less cable

Once the location of network devices has been decided, you should cre-ate documentation on where the cables will be installed A map of wiring should include how many cables will be installed in ceilings, walls, and other locations While creating the map, you will also be able to review issues that will arise during the actual cabling, such as holes that may have to be drilled

Table 2.3 Four-Pair Cable Color Code

pair Solid wire Striped wire

Table 2.4 Twisted-Pair Wire/Pin Placement

pin wire

1 Orange and white

3 Green and white

7 Brown and white

Trang 2

or vertical runs of cabling down elevator shafts When determining how

the cable should run from an outlet to a hub, switch, or router, you should

remember to keep the cabling at least three feet away from fluorescent lights

and other sources of EMI

Cables should be tested before they’re actually installed Even if new

cable is being used for the installation, this doesn’t guarantee that it isn’t

damaged in some way It is easier to test the cable before installation than

to determine where a section of bad cabling resides after installation is

complete

Once you’re ready to actually start running the cabling along the paths

you’ve planned out, you should ensure that you actually have more cable

than is needed left on the roll In running 100 feet of cable, you don’t want to

find there is only 90 feet of cable left in the box Having extra cabling will also

ensure that you have enough slack to navigate the cable without problems

Each end of a cable should be clearly marked, using masking tape or some

other form of labeling Because you may be installing several runs of cable at

a time, you don’t want to be confused as to which cable runs to a particular

computer or location By labeling the cables, this confusion is removed, and

you’ll be able to focus on the installation

If you need to bundle cable, you should only use cable ties Cable ties are

sturdy plastic strips that attach cables together into a ring When using them,

however, you should allow enough space to fit a finger into the cable tie

Having a cable tie too tight can damage the cables and make it more difficult

to cut when a cable has to be replaced Using cable ties is the safest method

of keeping cables together, as staples or other methods can damage cable

CABlE MANAGEMENT

Cable management and termination of cabling runs becomes important

when working as a Network technician You have learned how cable is

used to connect devices to networks, but how is the cabling managed? When

working on a network, it’s likely you will be asked to connect a device to it,

but how does it all interconnect? The answers to these questions are simple

When working in a Star-based network, you will likely have a central

con-centrator acting as a backbone for the entire switched and routed network

Because of this, it’s important to understand how cabling runs through your

walls, through cubicles and anywhere else through your facilities

Termination devices such as a 66 block or a 110 block are commonly

used to provide termination point and are generally located in wiring

clos-ets in your facility This makes it easy to now take those runs of let’s say

Trang 3

ChApTEr 2: Network Media

68

50 cables, and bundle them safely and keep them secure and ultimately run them to the central switch or backbone In the wiring closed, patch panels are used to connection RJ-45 or RJ-11 connectors so that moving systems becomes quick and easy No need to cut and recut and crimp and test cable – just move a cable from one port to the other to facilitate a move As long

as your network and cable runs are documented and kept up to date, you will always have a very flexible routine in which to add and remove or move nodes around your network Devices such as cross connections, terminators, termination blocks and the switch, and router ports you connect together offer a great deal of flexibility and ability to grow to larger sizes without a great deal of complication

For the Network exam, you will need to know how to install commonly used wiring distribution systems Distribution systems are nothing more than a term used to describe the hierarchical system of cross connections that lead to a local private branch exchange (PBX), central concentrator or the central office (CO) or elsewhere You will also need to know how to use patch panels, 66 or 110 blocks, deploy cable management and terminate devices correctly Next, we will take a close look at how patch panels and other termination devices are used to connect to other termination points

on your network

patch panels

Patch panels are ideal when used to allow for quick configuration manage-ment ability Need to move a computer? Simple – just move a cable or “punch down” the connection The term punch is used as slang when referring to the use of a punch down tool which is used to terminate copper wire on a termination block such as a 66 block, or 110 block

66 Block

When you want to terminate your connections you will want to connect to a

66 block When you want to terminate a connection on a 66 block, you need

to be careful not to untwist the pairs as this will introduce the possibility of corrupted data, crosstalk, or other interference issues

66 block type cross connects are used primarily for voice connection, although they can be used for data

Exam warning

You will use the term cross connect often while working as a technician For the exam it’s important to remember this term The term is used as a reference to the cable that runs from one block to another, generally 25-pair cable.

Trang 4

110 Block

When you want to terminate your connections you will want to connect

to a 110 block The 110 block is used (primarily) with data connections

Although there are newer patch panels that are used and have to some degree

replaced the 100 block, there are many networks out there today that still

have them implemented As with any other termination point, connections

need to be made carefully with a punch down (or impact) tool You need to

be careful and make solid connections to the block as a loose wire may cause

connection issues or other problems

Demarc

Demarc is a term used to describe where the providers equipment ends and

the private network begins It is also referred to as the termination point

where telecommunications from telephone companies inside a facility or

building Demarc extension is a common term used to describe cabling used

to connect to a router, switch, or other device from the smart jack

Smart Jack

The smart jack is a term used to describe the box (or case) and internal cards

(and other hardware) where you terminate your router or switching device

to get access to the lease line companies circuit For example, you could

connect a RJ-45- or RJ-48-based connector into a T1 smart jack and then

connect it to your router or CSU

lAN TEChNoloGIES ANd STANdArdS

In discussing the physical media that may be used on your network, it’s

important to understand the technologies that are used on them Although

we’ll discuss individual components of the network and technologies related

to them throughout this book, we’ll pause here to look at several technologies

related to physical media As networking technologies have developed over

the years, it became apparent that standards were necessary so components

of a network could work together effectively, and how data is transferred

Exam warning

Punch down (or impact) tools are handy for working with termination devices You should

know that the cutting blade and shape of the impact tool is different for 66 block

connec-tions and 110 block connecconnec-tions Make sure that you use the appropriate tool tip when

terminating your cables You should also test the run and any other cables you are using.

Trang 5

ChApTEr 2: Network Media

70

over the network cable These standards include Ethernet, Fast Ethernet, and Gigabit Ethernet

Ethernet

Ethernet is the standard for most of the networks today As we discussed in the previous chapter, Bob Metcalfe originally developed Ethernet as a tech-nology that networked together remote computers Digital, Intel, and Xerox took the original specifications and extended it to accommodate speeds of

10 Mbps using coaxial cable or specific categories of twisted-pair cabling In

1990, Ethernet was standardized by the 802.3 committee, and specifications under this correspond to 10Base2, 10Base5, and 10BaseT (each of which we’ll discuss later in this chapter)

A major component of Ethernet is the use of Carrier Sense Multiple

Access with Collision Detection (CSMA/CD) for access to the physical

medium CSMA/CD keeps devices on the network from interfering with one another when trying to transmit; when they do interfere with each other,

a collision has occurred To reduce collisions, CSMA/CD devices listen to the network before transmitting If the network is quiet (no other devices

are transmitting), the device can send its data Because two devices can both think that the network is clear and starts transmitting at the same time, resulting in a collision, all devices listen as they transmit If a device detects another device transmitting at the same time, both devices stop transmitting and send a signal to alert other nodes to the collision Then all the nodes stop transmitting and wait a random amount of time before they begin the process again

CSMA/CD doesn’t stop collisions from happening, but it helps to man-age the situations when collisions occur In fact, collisions are a very nor-mal part of Ethernet operations It’s only when collisions begin to occur frequently that you needed to become concerned

Ethernet has evolved over the years to include a number of popular specifications These specifications are due in part to the media variety they employ, such as coaxial, twisted-pair, and fiber-optic cabling

Fast Ethernet

Fast Ethernet is a standard that provides transmission of data at speeds of

100 Mbps It uses full duplex transmission, which enables data to pass in both directions at the same time Because of the speeds available through this standard, Fast Ethernet is generally used as a backbone on LANs to support workstations that have 10BaseT network cards The Fast Ethernet standard corresponds to the 100BaseT specifications, which we’ll discuss later in this chapter

Trang 6

Gigabit Ethernet

An even faster standard in the evolution of Ethernet is Gigabit Ethernet,

which provides speeds of 1 Gbps To compare this to the 10 Mbps of

Ethernet, which provides full duplex transmission speeds of 10 million bits

per second, Gigabit Ethernet supports speeds of 1 billion bits per second

Because of the bandwidth available through this standard, it is often used as

a backbone for many larger networks

Although Ethernet runs on either coaxial or twisted-pair, and Fast

Ether-net runs on pair cable, Gigabit EtherEther-net uses fiber-optic or

twisted-pair cabling to transmit data The optical fiber in the cable allows data to

transmit faster and over greater distances, making it useful for connecting

different locations at high speeds

MEdIA STANdArdS

As we discussed in the previous chapter, the Institute of Electrical and

Electronic Engineers (IEEE) is an organization that sets standards on a

vari-ety of technologies Various committees are used to develop and promote

these standards, including the 802 committee, which is broken down into

smaller subcommittees or working groups that focus on specific aspects of

networking One of these subcommittees is the 802.3 working group, which

has set standards for physical media used on networks

hEAd oF ThE ClASS…

10 Gigabit Ethernet

In looking at how the speed of Ethernet has increased over

the years, it should come as no surprise that even Gigabit

Ethernet isn’t fast enough to stop developing the standard

10 Gigabit Ethernet isn’t a standard yet, but at the time of

this writing, it is currently in the process of becoming one

10 Gigabit Ethernet provides transmission speeds of up

to 10 Gbps (10 billion bits per second), while using

tech-nologies that already exist in most modern networks.

As with Gigabit Ethernet, 10 Gigabit Ethernet uses

fiber-optic cabling that allows it to transmit data over a

longer distance, and uses full duplex transmission so that

data can pass in both directions along the cable at the

same time Various types of 10 Gigabit Ethernet include:

10GBaseSR supports short distances over

multi-■

mode fiber (MMF) optic cable, and it has a range

of 26 m and 82 m depending on the cable type

It also supports distances of 300 m over a new

2000 MHz km MMF.

10GBaseLX4 that uses wavelength division

mul-■

tiplexing and supports ranges of 240 m and 300

m over MMF, or 10 km over single-mode fiber (SMF).

10GbaseLR that supports 10 km over SMF.

10GbaseER that supports 40 km over SMF.

10 Gigabit Ethernet is gaining acceptance, and the 802.3a standard defines a version, but currently there

is no commercial version available As there are differ-ent methods of implemdiffer-enting this technology, it is not known whether it will become a LAN or WAN technology Additional information can be found at the 10 Gigabit Ethernet Alliance Web site at www.10gea.org.

Trang 7

ChApTEr 2: Network Media

72

10Base2, 10Base5, and Arcnet

10Base2 (also known as Thinnet) is a thin coaxial cable used on Ethernet

net-works The cable used in 10Base2 is an RG-58 cable that is 6.3 mm or 1/4 inch

in diameter and supports transmission speeds of 10 Mbps Used on bus topolo-gies, the network cards are attached to the cable using a BNC T-connector, and the backbone cable is terminated at each end using a 50 Ω terminator The 10Base2 cable has a maximum length of 185 m or 600 feet per segment, and workstations must be spaced a minimum distance of 1/2 m from one another

10Base5 (Thicknet) is a thicker type of coaxial cable that is 13 mm or

1/2 inch in diameter and supports transmission speeds of 10 Mbps The cable has a maximum length of 500 m or 1640 feet per segment Like 10Base2, 10Base5 is used on bus topologies and must be terminated on each end using

a 50 Ω terminator However, unlike 10Base2, 10Base5 generally isn’t directly connected to workstations on the network Instead, a vampire tap is used to pierce the cable so that a connection can be made to the cable An N

connec-tor or a cabling tray and transceiver called a media attachment unit (MAU) are connected to the cable Another cable called an attachment unit interface

(AUI) that can be up to 50 m in length is then run to the network card of the workstation Each end of the AUI cable uses a 15 pin D-connector, which is also referred to as a Digital-Intel-Xerox (DIX) or DB-15 connector Although we’ll discuss transceivers and connectors in greater detail later in this chap-ter, it’s important to remember that a 10Base5 cable can have no more than

100 taps per cable segment, with each tap spaced 2 1/2 m apart

Determining how long a 10Base5 cable could be lengthened using dif-ferent segments can be calculated using the 5-4-3 rule A 10Base5 cable can have up to five segments, with four repeaters, with only three of the segments having devices attached to it By using the maximum cable length with repeaters between each of the five segments, this would lengthen the cable to a maximum of 2460 m However, because only three of the seg-ments can have a maximum of 100 devices attached, this means that even

by lengthening the cable in this manner you are limited to a maximum of

300 devices on the bus topology

The problem with 10Base2 and 10Base5’s cabling architecture is that a single fault in the cable can bring the entire network down As we discussed

in the previous chapter, each end of the cable must be terminated in a bus topology or the data will continue to bounce back and forth along the cable This prevents any other workstations from being able to transmit data onto the network without causing collisions

Arcnet is another technology addressed in the 802.3 standards that uses coaxial cable Arcnet is a token bus technology, just as Ethernet, Token Ring, and FDDI are technologies used on a network As with Token Ring, when a

Trang 8

workstation on an Arcnet network receives a token, it has the opportunity to

communicate on the network If it doesn’t have any data to send, then the

next workstation on the bus then gets the token If it does send data, then

the receiving machine resets the token and others can then transmit data

when they get the token

With the various applications of coaxial (10Base2, 10Base5, and Arcnet),

there are different coaxial cables that may be used These include:

RG-58 /U, which has a solid copper wire, is used for 10Base2 networks

RG-58 A/U, which has a stranded copper wire, can also be used for

10Base2 networks

RG-58 C/U, which is a military implementation of RG-58 A/U

RG-59, which is used for broadband transmissions (such as cable

television), and is used for 10Base5 networks

RG-6, which is used for broadband, but supports higher

transmis-■

sion rates than RG-59

RG-62, which is used for Arcnet

RG-8, which is 10Base5 cable

NoTES FroM ThE FIEld…

Security Issues with Coaxial Cable

The coaxial cable used in both 10Base2 and 10Base5

share some of the same vulnerabilities Unfortunately,

it is relatively easy to perform a denial of service (DoS)

attack on this type of network by cutting the cable or

disconnecting a device If communication is not able

to flow completely up and down a coax network, the

entire network is brought down In addition, because

connections to the network really cannot be controlled

with a switch or hub, there is no way to prevent

unau-thorized connections All an intruder has to do is tap

into the network with either a T-connector or vampire

tap for Thinnet or Thicknet, respectively.

These vulnerabilities exist due to the topology of

coax networks A coax network uses a bus topology,

which basically means that all of the network devices

are connected in a linear fashion Each device on the

network completes the circuit for the network as a whole Because of this, if any device is removed from the network or if there is a break anywhere in the cable, the circuit is broken and the entire segments of the network is brought down unless it is the backbone that could then leave the entire network in a down state.

The main advantages to coax networks are the price and the ease of implementation As no expensive hubs

or switches are required, cost is kept low Since all that is required to set up the network is to run a coax cable ran

as the backbone and then one connection, connecting them one computer to the next with T-connectors This

is one of the easiest networks to implement.

Most coax networks have been or are being replaced with UTP/STP or fiber-optic cabling Although you may never work with a coax network, it is important to know how vulnerable it is to disruption of service or intrusion.

Trang 9

ChApTEr 2: Network Media

74

10BaseT and Beyond

In addition to the standards that use coaxial cable, there are also those that use twisted-pair and fiber-optic cabling These are more commonly used on today’s networks, and knowledge of them is essential when designing or maintaining a network in the real world The various types of media avail-able are shown in Tavail-able 2.5

10BASE-T

10BaseT is one of the most common media standards found on networks It

is deployed on networks that use a star topology, which we discussed in the previous chapter It uses UTP cabling to transmit data at speeds of 10 Mbps across cable segments that are up to 100 m in length Although it will work

on Category 3 UTP, a higher grade of cable is recommended

10BaseFL

10BaseFL is an older, but widely used fiber optic standard, and is sometimes referred to generically as 10BaseF It uses fiber-optic cabling to transmit data at speeds of 10 Mbps across cable segments that are up to 2 km in length

Table 2.5 Media Standards Using Twisted-Pair and Fiber

Media Standard Cable Type Bandwidth Cable length

10BaseT UTP (Category 3 or higher) 10 Mbps 100 m 100BaseTX UTP (Category 5 or higher) 100 Mbps 100 m

or 2 km (full-duplex) 1000BaseT UTP (Category 5 or higher) 1 Gbps (1000 Mbps) 100 meters 1000BaseSX Fiber-optic 1 Gbps (1000 Mbps) 550 m (MMF) 1000BaseLX Fibe-optic 1 Gbps (1000 Mbps) 550 m (MMF) or up

to 10 km (SMF) 1000BaseCX Fiber-optic 1 Gbps (1000 Mbps) 100 m

Exam warning

For the exam, you will have to memorize the characteristics of the various types of media Questions may appear that specifically require this knowledge.

Trang 10

100BaseTX uses UTP cabling to transmit data at speeds of 100 Mbps across

cable segments that are up to 100 m in length The UTP must be Category 5

or higher Another common term that relates to 100BaseT is Fast Ethernet

100BaseTX cables use two sets of two pairs, or eight wires Eight wires are

standard with Cat5

100BaseFX

100BaseFX is another Ethernet standard that uses fiber-optic cabling to

transmit data at a speed of 100 Mbps The distance that this standard can

achieve depends upon whether half-duplex is used to achieve collision

detec-tion If communication is half-duplex, it can transmit data across cable

seg-ments that are up to 400 m in length If full duplex is used, then it can

transmit data up to 2 km

1000BaseT

1000BaseT is a Gigabit Ethernet standard that allows data to be transmitted

over twisted-pair cabling at 1 Gbps This means that 1000 Mb or 1 billion

bits of data can be transmitted each second 1000BaseT uses UTP cabling to

transmit data at these speeds across cable segments that are up to 100 m in

length For this to be used however, the UTP must be Category 5 or higher

1000BaseCX

1000BaseCX uses fiber-optic cabling to transmit data at a speed of 1 Gbps

across cable segments that are up to 100 m in length Because it is an older

standard, it isn’t commonly used on newer networks

1000BaseSX

100BaseSX uses MMF-optic cabling to transmit data at a speed of 1 Gbps

across cable segments that are up to 550 m in length

1000BaseLX

1000BaseLX uses fiber-optic cabling to transmit data at speeds of 1 Gbps

Using MMF, data can be sent across cable segments that are up to 550 m in

length, while SMF will allow longer distances of up to 10 km

CoNNECTorS

Although we’ve discussed a significant number of issues related to the

physi-cal media used on a network, it’s important to remember that a cable is more

than the wire or fiber that transmits the data Cables have to be connected

to the NIC or other devices on a network A connector is an interface that

Ngày đăng: 04/07/2014, 13:20

TỪ KHÓA LIÊN QUAN