Connecteurs pour équipements électroniques –Partie 4-100: Connecteurs pour cartes imprimées sous assurance de la qualité – Spécification particulière pour les modules de connecteurs en d
Méthode recommandée pour le montage
The connectors are equipped with solder or force-fit contacts The retention of the connector is achieved through force-fit terminals The connector outputs must be compatible with the holes on the printed circuit boards, arranged on a 2.5 mm grid as per standard specifications.
Les embases sont munies soit:
– de contacts à insérer à force et connexions enroulées;
– de contacts à insérer à force et connexions enroulées et zone de contact.
The connector is secured onto the force-inserted contacts, eliminating the need for mounting holes on the bottom of the basket The distance between the output axes is 2.5 mm or a multiple thereof, and the base outputs are compatible with basket bottoms that have a 2.5 mm pitch.
NOTE Les informations concernant les fabricants qui ont des composants conformes à la présente spécification particulière sont données dans la liste des produits homologués.
Caractéristiques et conditions nominales de fonctionnement
Tension assignée: Contact/contact pour connecteur complètement chargé (disposition 1)
Groupe de matériaux Degré de pollution Tension assignée
Refer to Table 14 of this specification and Table 4 of IEC 60664-1, which illustrate the relationship between creepage distances, pollution degrees, and material groups in relation to effective voltage levels.
Courant nominal: 1 A à 70 °C pour connecteur complètement chargé (disposition 1)
Résistance d’isolement: 10 6 MΩ min pour PL1 et PL2
Epaisseur de carte: 1,6 mm à 3,2 mm pour les fiches
1,6 mm min pour les embases Pas entre contacts: 2,5 mm
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Free board connectors are available with either solder or press-in contacts, and they are mounted using press-in pivots According to IEC 60326-3, the terminations of these connectors are designed to fit into holes on the printed board, which are arranged on a 2.5 mm grid.
The fixed board connectors are provided either with:
– press-in and wrap contacts;
– press-in and wrap and mating area contacts.
The connector is securely attached to the press-in contacts, eliminating the need for fixing holes on the backplane The termination center lines are spaced at 2.5 mm or its multiples, making the fixed board connectors compatible with backplanes that have a grid dimension of 2.5 mm.
NOTE Information about manufacturers who have components qualified to this detail specification is given in the
Rated voltage: Contact/contact for fully loaded connector
Material group Pollution degree Rated voltage
NOTE Reference is made to table 14 of this specification, and table 4 of IEC 60664-1 listing the relation between creepage distances, pollution degree and material groups versus voltages r.m.s.
Current rating: 1 A at 70 °C for fully loaded connector (arrangement 1)
Insulation resistance: 10 6 MΩ min for PL1 and PL2
Printed board thickness: 1,6 mm to 3,2 mm for free board connector
1,6 mm min for fixed board connector
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Marquage
Le marquage du connecteur et de son emballage doit être conforme à 2.6 de la CEI 61076-4.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
This section of IEC 61076 references several normative documents that are integral to its provisions For documents with specific dates, any amendments or revisions that occur afterward are not applicable However, it is advisable for parties involved in agreements based on this standard to consider using the latest editions of the referenced normative documents In the case of undated references, the most recent edition of the cited document is applicable Additionally, both IEC and ISO keep updated registers of valid International Standards.
IEC 60068-1:1988, Environmental testing – Part 1: General and guidance
IEC 60297-3:1984, Dimensions of mechanical structures of the 482,6 mm (19 in) series – Part
3: Subracks and associated plug-in units
IEC 60326-3:1991, Printed boards – Part 3: Design and use of printed boards
IEC 60352-1:1997, Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance
IEC 60352-5:1995, Solderless connections – Part 5: Solderless press-in connections –
General requirements, test methods and practical guidance
IEC 60410:1973, Sampling plans and procedures for inspections by attributes
IEC 60512 (all parts): Connectors for electronic equipment – Tests and measurements (see
IEC 60664-1:1992, Insulation coordination for equipment within low-voltage systems – Part 1:
IEC 60917-2-2:1994 outlines the modular order for developing mechanical structures for electronic equipment This standard specifies the interface coordination dimensions relevant to the 25 mm equipment practice It includes detailed specifications for dimensions concerning subracks, chassis, backplanes, front panels, and plug-in units, ensuring compatibility and standardization in electronic equipment design.
IEC 61076-1:1995, Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications – Part 1: Generic specification
IEC 61076-4:1995, Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications – Part 4: Sectional specification – Printed board connectors
IEC 61076-4-102:1997, Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications – Part 4: Printed board connectors –
Section 102 outlines the detailed specifications for two-part single-pole connectors designed for various applications on plug-in units These connectors feature pre-centering coding and early mating capabilities, adhering to a metric grid as specified by IEC 60917.
Marking of the connector and the package shall be in accordance with 2.6 of IEC 61076-4.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Désignation de type CEI
Les connecteurs, les boợtiers de connecteurs et les contacts conformes à la prộsente norme doivent correspondre au système suivant:
NOTE ô L ằ dộsigne une lettre. ô N ằ dộsigne un chiffre.
Définitions
Disposition de contacts mâles pour fond de panier
Figure 1 illustrates a male contact arrangement for a basket background featuring a continuous grid with a 2.5 mm pitch This design allows the male contacts of both connectors to be positioned according to the grid in both height and width The housings of the plugs and sockets are specifically designed to accommodate a continuous grid of male contacts with a 2.5 mm pitch.
Boợtier de fiche: moulage pour connecteur femelle
Boợtier d’embase: moulage de reprise pour embase
Boợtier de reprise: reprise sans contacts
Contact FMLB: Contact sộquentiel ô Contact First Mate Last Break ằ
Figure 1 – Disposition de contacts mâles pour fond de panier
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Figure 1 illustrates a backplane male contact configuration featuring a continuous 2.5 mm grid, allowing for male contacts to align on the pitch line of two connectors in both height and width The design of free and fixed board connector bodies accommodates this continuous 2.5 mm grid of male contacts.
Free board connector body: moulding for female connector
Fixed board connector body: moulded shroud for fixed board connector
Fixed board connector: shroud with contacts
Interface shroud: shroud without contacts
FMLB contact: First mate last break contact
Figure 1 – Backplane male contact arrangement
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Tableau des modèles et des variantes
De 1 à 10 unités systèmes (SU) et de 12 à 475 lignes accouplées, pour les détails voir le tableau 2.
Tableau 2 – Disposition des contacts et nombre de contacts
Disposition des contacts 1) 1 Nombre de contacts 35 85 185 425 475
Disposition des contacts 1) 2 Nombre de contacts 18 43 93 214 239
Disposition des contacts 1) 3 Nombre de contacts 12 27 57 132 147
1) Disposition des contacts selon 2.4.1 et 2.4.2.
2) Ce modèle permet seulement une compatibilité limitée en aval avec les équipements habituels selon la
Lettre et chiffre d’identification pour les modèles de sorties
Sortie de CIF avec broche élastique sur fiche adaptée pour carte imprimée d'une épaisseur de 1,6 mm à 3,2 mm et trous métallisés de diamètre: 1 selon la CEI 60352-5
Sortie de CIF avec broche solide sur fiche adaptée pour carte imprimée d'une épaisseur de 1,6 mm à 3,2 mm et trous métallisés de diamètre: 1 selon la CEI 60352-5
Sortie de CIF avec broche élastique sur embase adaptée pour carte imprimée d'une épaisseur de 1,6 mm à 4,0 mm et trous métallisés de diamètre: 1 selon la CEI 60352-5
Sortie de CIF avec broche solide sur embase adaptée pour carte imprimée d'une épaisseur de 1,6 mm à 4,0 mm et trous métallisés de diamètre: 1 selon la CEI 60352-5
Sortie comme P-3 avec bornes 0,6 mm × 0,6 mm pour une connexion enroulée, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-4 avec bornes 0,6 mm × 0,6 mm pour une connexion enroulée, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-3 avec bornes 0,6 mm × 0,6 mm pour deux connexions enroulées, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-4 avec bornes 0,6 mm × 0,6 mm pour deux connexions enroulées, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-3 avec bornes 0,6 mm × 0,6 mm pour trois connexions enroulées, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-4 avec bornes 0,6 mm × 0,6 mm pour trois connexions enroulées, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
2.2 Survey of styles and variants
From 1 to 10 system-units (SU) and from 12 to 475 mated lines, for details see table 2.
Table 2 – Contact arrangement and number of contacts
Contact arrangement 1) 1 Number of contacts 35 85 185 425 475
Contact arrangement 1) 2 Number of contacts 18 43 93 214 239
Contact arrangement 1) 3 Number of contacts 12 27 57 132 147
1) Contact arrangements according to 2.4.1 and 2.4.2.
2) This style allows a limited downward compatibility to equipment practice according to IEC 60297-3.
Identification letter and number for style of termination
Termination for press-in with compliant pin on free board connector to a printed board with a thickness of 1,6 mm to 3,2 mm, and through metallized holes, diameter: 1 according to
Termination for press-in with solid pin on free board connector to a printed board with a thickness of 1,6 mm to 3,2 mm, and plated through holes, diameter: 1 according to IEC 60352-5
Termination for press-in with compliant pin on fixed board connector to a printed board with a thickness of 1,6 mm to 4,0 mm, and through metallized holes, diameter: 1 according to
Termination for press-in with solid pin on fixed board connector to a printed board with a thickness of 1,6 mm to 4,0 mm, and plated through holes, diameter: 1 according to IEC 60352-5
0,6 mm × 0,6 mm for one wrap, wire diameter: 0,25 mm according to
IEC 60352-1 and male mating area for rear I/O connection
Termination as P-4 with posts 0,6 mm × 0,6 mm for one wrap, wire diameter: 0,25 mm according to IEC 60352-1 and male mating area for rear I/O connection
0,6 mm × 0,6 mm for two wraps, wire diameter: 0,25 mm according to
IEC 60352-1 and male mating area for rear I/O connection
Termination as P-4 with posts 0,6 mm × 0,6 mm for two wraps, wire diameter: 0,25 mm according to IEC 60352-1 and male mating area for rear I/O connection
0,6 mm × 0,6 mm for three wraps, wire diameter: 0,25 mm according to
IEC 60352-1 and male mating area for rear I/O connection
Termination as P-4 with posts 0,6 mm × 0,6 mm for three wraps, wire diameter: 0,25 mm according to IEC 60352-1 and male mating area for rear I/O connection
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Renseignements sur l’application
Connecteurs complets (paires)
Starting from the 25 mm multi-module, connector models can be stacked vertically without a specific order The arrangement of the pins typically matches that of the sockets.
Exemples de dispositions de fiches et d’embases.
– Modèles de connecteurs différents acceptable si le pliage et le décalage des connecteurs assemblés ne dépassent pas 0,5 mm
– Combinaisons interdites les conditions d’accouplement ne sont pas garanties car il n’y a pas de guide aux extrémités n = 4 n = 2 n = 4 n = 10 n = 10
Figure 2 – Fiches et embases pour disposition modulaire
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
The multi-module 25 mm connectors offer versatile stackable styles that can be arranged in varying heights Typically, the layout of the free board connectors aligns with that of the fixed board connectors.
Examples for arrangements of fixed and free board connectors.
– Different connector styles acceptable if bending and offsetting of assembled connectors do not exceed 0,5 mm
– Combinations not permitted mating conditions are not guaranteed because of missing guidance at the ends n = 4 n = 2 n = 4 n = 10 n = 10
Figure 2– Free and fixed board connectors for modular arrangement
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Embases
Planéité avant opération d’insertion à force sur fond de panier selon 3.4.1 et après insertion à force sur fond de panier selon 5.1.7.
Fiches
Planéité avant opération d’insertion à force sur carte imprimée selon 3.5.1 et après insertion à force sur carte imprimée selon 5.1.7.
Accessoires
Blindage et continuité de masse
Types de base de sortie
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Planarity before press-in operation to backplane according to 3.4.1 and after press-in to backplane according to 5.1.7.
Planarity before press-in operation to printed board according to 3.5.1 and after press-in to printed board according to 5.1.7.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Dispositions des contacts
Embases
Face d’accouplement Plan de perỗage
NOTE Pour les informations de montage, voir 3.7.1 (plan de perỗage).
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
NOTE For mounting information see 3.7.1 (hole pattern).
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Fiches
NOTE Pour les informations de montage, voir 3.8.1 (plan de perỗage).
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
NOTE For mounting information see 3.8.1 (hole pattern).
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Généralités
Toutes les dimensions sont exprimées en millimètres.
The drawings are depicted in first-angle projection The shape of the connectors may differ from what is shown in the following figures, provided that the specified dimensions remain unaffected.
Les renseignements concernant la flèche en 3.3.3 et 5.1.7 sont valables pour les conditions de livraison La flèche acceptable pour un connecteur monté est indiquée en 5.1.7.
Les dimensions manquantes peuvent être choisies conformément aux caractéristiques communes et à l’utilisation prévue.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
All dimensions are in millimetres.
The drawings are presented in first angle projection, and while the shape of the connectors may vary from the figures provided, the specified dimensions must remain unaffected.
The information about the bending in 3.3.3 and 5.1.7 is valid for the condition of delivery The permissible bending of the mounted connector is stated in 5.1.7.
Missing dimensions can be chosen according to the common characteristics and the intended use.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Vue isométrique et caractéristiques communes
Caractéristiques communes
Système de référence
Les dimensions de coordination sont des dimensions sans tolérance; elles indiquent la dimension maximale garantissant la disposition modulaire.
These coordination dimensions are based on the 0.5 mm module and the multi-modules of 2.5 mm and 25 mm specified in IEC 60917 Reference plans are detailed in sections 3.2.3, 3.2.4, and 3.2.5.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Table 4 – Isometric view and common features
H n x 25 Maximum height of the modular fixed board connector with n = 1, 2, 4, 9, 10
M 15 – 17,5 Contact range in plug-in direction (see figure 9)
NOTE For information only see 3.3.
X2 H – 5 Distance between centre lines of the press-in pivots of the free board connector f 2,5 Grid dimensions of the terminations of the fixed board connector
The distance between the center lines of the press-in pivots and the first or last row of holes for contact termination of the free board connector is 2.5 mm Additionally, the distance from the center lines of the press-in pivots to the first row of holes for contact termination measures 1.25 mm The edge of the printed board is positioned 3.75 mm from the center lines of the first row of holes for contact termination Finally, the distance between the center lines of the press-in pivots of the free board connector is 10 mm.
Coordination dimensions are dimensions without tolerances and indicate the maximum dimension to guarantee the modular arrangement.
These coordination dimensions are based upon the 0,5 mm module and the multi-modules 2,5 mm and 25 mm specified in IEC 60917 The datum planes are indicated in 3.2.3, 3.2.4 and
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Dimensions en hauteur
Plan de référence de bac Fond de panier
Bac Rail guide Carte imprimée Fiche
Figure 6 – Dimensions en hauteur Tableau 5 – Dimensions en hauteur
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Datum plane of subrack Backplane
Subrack Guide rail Printed board Free board connector
Figure 6 – Height dimensions Table 5 – Height dimensions
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Dimensions en largeur
B 1 = référence de largeur par rapport à la carte imprimée 2 × 2,5 = 5 mm
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Printed board Free board connector
B 1 = width reference to printed board 2 × 2,5 = 5 mm
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Dimensions en profondeur
Axes des pions de centrage pour fixation de fiches
T = Axes des connexions CIF (première rangée) de la fiche par rapport au plan de montage embase 6 × 2,5 = 15 mm
D = Epaisseur de la base du connecteur embase 2,5 mm
T 1 = Distance entre le bord de la carte imprimée et l’axe des connexions CIF fiche (première rangée) 2,5 mm
T 2 = Distance entre l’axe des connexions CIF et la première rangée de sorties fiche 1,25 mm
T 3 = Intervalles entre sorties fiche 2,5 mm
T 4 = Distance entre l’axe des connexions CIF fiche 10 mm
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Centre lines of pivots for free board connector fixing
Free board connector Reference pivot
Figure 8 – Depth dimensions Table 7 – Depth dimensions
T = Centre line of press-in pivots (first row) of free board connector to mounting plane fixed board connector 6 × 2,5 = 15 mm
D = Thickness of connector bottom fixed board connector 2,5 mm
T 1 = Distance between edge of printed board and centre line of pivots for free board connector fixing (first row)
T 2 = Distance between centre line of pivots and first row of terminations free board connector
T 3 = Spacing of terminations free board connector 2,5 mm
T 4 = Distance between centre lines of pivots for free board connector fixing 10 mm
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Renseignements concernant l’accouplement
Longueur d’enfichage électrique
La résistance de contact spécifiée doit être maintenue sur une paire accouplée dans la gamme M = 15 mm à 17,5 mm.
Si le connecteur peut être engagé de moins de M = 15 mm, la résistance de contact spécifiée doit également être remplie.
Common prescriptions for FMLB contacts are provided in this specification Under the most unfavorable coupling conditions and with the least favorable dimensions for a paired coupling, the pre-coupling of the contact is essential.
The nominal value of the pre-coupling is 1.75 mm The quantity and arrangement of the pre-coupling contacts must be agreed upon separately between the user and the manufacturer.
3.3.1.1 Niveaux et ordres des contacts
Tableau 8 – Plages de performance de contact sûr
Niveau de contact Contact mâle normalisé Contact FMLB
Plage de longueur de l’engagement électrique
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
The specified contact resistance shall be maintained on a mated pair, within the range of
If the connector could be engaged below dimension M = 15 mm, the specified contact resistance shall also be met.
This specification outlines the standard requirements for FMLB contacts, indicating that under the most unfavorable mating conditions and dimensions of a paired contact, the pre-mating distance is set at 0.15 mm.
The nominal pre-mating is 1,75 mm Number and arrangement of the pre-mating contacts are to be agreed separately between user and producer.
Centre lines of reference pivots
Table 8 – Ranges of safe contact performance
Contact level Standard male contact FMLB contact
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Position de contact sûre Contact mâle
Figure 10 – Premier point de contact
3.3.1.3 Direction perpendiculaire à celle de l’enfichage (accouplement)
The design of the socket and base must accommodate an alignment tolerance of at least 1 mm in both the transverse and longitudinal directions of the connectors To achieve the required alignment between the two components, one part of the connector pair is mounted in a floating manner.
Pour les paires de connecteurs à montage fixe, les tolérances de montage doivent être maintenues dans une plage suffisamment réduite.
Figure 11 – Direction perpendiculaire à celle de l’enfichage (accouplement)
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Safe contact position Male contact
3.3.1.3 Perpendicular to engagement (mating) direction
The free and fixed board connector is designed to accommodate a misalignment of at least 1 mm in both the transversal and longitudinal directions To ensure proper alignment between the two connector parts, one component of the connector pair is float mounted.
For fixed mounted connector pairs, the mounting tolerances shall be kept accordingly in a sufficient small range.
Figure 11 – Perpendicular to engagement (mating) direction
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Inclinaison
La conception de la fiche et de l’embase doit tolérer un défaut d’alignement angulaire initial de ±0,5° selon les axes longitudinal et transversal.
En position accouplée, la condition de 3.3.1 doit être remplie.
Le défaut d’alignement angulaire autorisé de ±0,5° est valable pour 10 multi-modules maximum et inclut l’écart total entre armoires et tiroirs pour les contacts de pré-accouplement. ± 0 ,5 ° ± 0 ,5 °
Planéité
La déformation autorisée des connecteurs montés est représentée en 5.1.7.
Pour garantir le fonctionnement du contact FMLB, la déformation du connecteur monté ne doit pas dépasser 0,3 mm par 250 mm.
Embases
Dimensions
Hauteur 25 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
The design of the free and fixed board connector shall accept an initial angular misalignment of ±0,5° in longitudinal and transverse axes.
In the mated position, the condition according to 3.3.1 shall be met.
The permissible angular misalignment of ±0,5° is valid for 10 multi-modules maximum and includes the total deviation from racks to subracks considering the pre-mated contacts. ± 0 ,5 ° ± 0 ,5 °
Permissible warpage of mounted connectors is shown in 5.1.7.
In order to guarantee the function of the FMLB contact, the warpage of the mounted connector per 250 mm length shall not exceed 0,3 mm.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Les positions 1 et 9 de toutes les rangées ne sont pas chargées de contacts, mais des alvéoles doivent être prévues pour les contacts mâles.
Tous les modèles – pour la disposition des contacts, voir 2.4.1 – pour les sorties voir 3.4.2.
Détails de W et X et vues de U et V, voir figure 14.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1 and 9 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
All styles – for contact arrangements see 2.4.1 – for terminations see 3.4.2.
Details W and X and views U and V see figure 14.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Détails de W et X et vues de U et V
1) Dimensions pour: contact normalisé 8,3 mm; contact FMLB 10,05 mm.
2) Tolérance pour tous les contacts avec la même longueur.
3) Par rapport au pas n × 2,5 mm.
6) Zone de contact pour forme de contact de reprise arrière selon les détails W et X.
Figure 14 – Détails de W et X et vues de U et V
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Details W and X and views U and V
1) Dimensions for: standard contact 8,3 mm;
2) Tolerance for all contacts with the same length.
3) With regard to grid n × 2,5 mm.
6) Contact area for rear side interface connector contact shape according to details W and X.
Figure 14 – Details W and X and views U and V
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Hauteur 50 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Les positions 1 et 19 de toutes les rangées ne sont pas chargées de contacts mais des alvéoles pour contacts mâles doivent être prévues.
Pour les dimensions manquantes, voir 3.4.1.1.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1 and 19 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Hauteur 100 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Les positions 1 et 39 de toutes les rangées ne sont pas chargées de contacts mais des alvéoles pour contacts mâles doivent être prévues.
Pour les dimensions manquantes, voir 3.4.1.1.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1 and 39 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Hauteur 225 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Les positions 1, 39, 51 et 89 de toutes les rangées ne sont pas chargées de contacts mais des alvéoles pour contacts mâles doivent être prévues.
Pour les dimensions manquantes, voir 3.4.1.1.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1, 39, 51 and 89 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Hauteur 250 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Les positions 1, 39, 61 et 99 de toutes les rangées ne sont pas chargées de contacts mais des alvéoles pour contacts mâles doivent être prévues.
Pour les dimensions manquantes, voir 3.4.1.1.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1, 39, 61 and 99 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Sorties
Profondeur du plan de référence (plan de montage)
Variantes de sorties Zone de
Sortie de CIF pour carte imprimée d’épaisseur de 1,6 mm à 3,2 mm et trous métallisés de diamètre selon le tableau 3
Sortie de CIF pour carte imprimée d'épaisseur de 1,6 mm à 4,0 mm et trous métallisés de diamètre selon le tableau 3
Sortie comme P3 ou P4 avec bornes de
0,6 mm × 0,6 mm pour zone de contact mâle arrière pour connexion E/S arrière
Sortie comme P3 ou P4 avec bornes de
0,6 mm × 0,6 mm pour une connexion enroulée sur fil d’un diamètre de 0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S arrière
Sortie comme P3 ou P4 avec bornes de
0,6 mm × 0,6 mm pour deux connexions enroulées sur fil d’un diamètre de 0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S arrière
Remarque: plan de perỗage selon 3.7.1.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Reference plane depth (mounting plane)
Figure 19 – Terminations Table 9 – Dimensions of terminations
Termination variants Compliant press-in zone
Termination for press-in to a printed board with a thickness of 1,6 mm to 3,2 mm, and through metallized holes, diameter according to table 3
Termination for press-in to a printed board with a thickness of 1,6 mm to 4,0 mm, and through metallized holes, diameter according to table 3
Termination as P3 or P4 with posts
0,6 mm × 0,6 mm for male mating area for rear I/O connection
Termination as P3 or P4 with posts
0,6 mm × 0,6 mm for one wrap, wire diameter 0,25 mm according to IEC 60352-1 and male mating area for rear I/O connection
Termination as P3 or P4 with posts
0,6 mm × 0,6 mm for two wraps, wire diameter 0,25 mm according to IEC 60352-1 and male mating area for rear I/O connection
Remark: hole pattern according to 3.7.1.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Fiches
Dimensions
Hauteur 25 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Largeur du plan de référence (surface de contact de la carte)
Les positions 1 et 9 de toutes les rangées ne sont pas chargées de contacts, mais des alvéoles pour contacts mâles doivent être prévues.
Tous les modèles – pour les dispositions des contacts, voir 2.4.2 – pour les sorties, voir 3.5.2.
Vue X et détails V, W, Y, Z voir figure 21.
1) Point de contact, tolérance commune pour tous les points de contact.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Recesses with feed-in funnel
Reference plane width (contact surface of board)
Positions 1 and 9 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
All styles – for contact arrangements see 2.4.2 – for terminations see 3.5.2.
View X and details V, W, Y, Z see figure 21.
1) Contact point, common tolerance for all contact points.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
2) Pour les modèles A à D = 0,06 mm, pour les modèles G et H = 0,08 mm.
3) Axe des connexions CIF pour la fixation aux cartes, pour les trous, voir 3.8.
4) Pour les modèles A et B = 0,06 mm, pour les modèles D, G et H = 0,08 mm.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
2) For styles A to D = 0,06 mm for styles G and H = 0,08 mm.
3) Press-in pivots for fixing to the boards, holes, see 3.8.
4) For styles A and B = 0,06 mm for styles D, G and H = 0,08 mm.
Figure 21 – View X and details U, V, W, Y and Z
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Hauteur 50 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Les positions 1 et 19 de toutes les rangées ne sont pas chargées avec des contacts mais des alvéoles pour contacts mâles doivent être prévues.
Pour les dimensions manquantes, voir 3.5.1.1.
1) Seulement dans les rangées A et E.
3) Les bornes et les connexions CIF doivent être dans le pas si le connecteur est redressé.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1 and 19 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
3) Terminals and press-in pivots shall be in the grid, if the connector is straightened.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Hauteur 100 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Les positions 1 et 39 de toutes les rangées ne sont pas chargées avec des contacts mais des alvéoles pour contacts mâles doivent être prévues.
Pour les dimensions manquantes, voir 3.5.1.1 et 3.5.1.2.
1) Les bornes et les connexions CIF doivent être dans le pas si le connecteur est redressé.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1 and 39 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
For missing dimensions see 3.5.1.1 and 3.5.1.2.
1) Terminals and press-in pivots shall be in the grid, if the connector is straightened.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Hauteur 225 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Les positions 1 et 39 de toutes les rangées ne sont pas chargées avec des contacts mais des alvéoles pour contacts mâles doivent être prévues.
Pour les dimensions manquantes, voir 3.5.1.1 et 3.5.1.2.
1) Les bornes et les connexions CIF doivent être dans le pas si le connecteur est redressé.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1 and 39 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
For missing dimensions, see 3.5.1.1 and 3.5.1.2.
1) Terminals and press-in pivots shall be in the grid, if the connector is straightened.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Hauteur 250 mm (dimension de coordination)
Largeur 15 mm (dimension de coordination)
Les positions 1 et 39 de toutes les rangées ne sont pas chargées avec des contacts mais des alvéoles pour contacts mâles doivent être prévues.
Pour les dimensions manquantes, voir 3.4.1.1 et 3.4.1.2.
1) Les bornes et les connexions CIF doivent être dans le pas si le connecteur est redressé.
Sorties
Accessoires
On peut effectuer le codage au moyen d’un module complémentaire sur une extrémité des connecteurs ou sur les deux; voir la CEI 61076-4-102.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Positions 1 and 39 in all rows are not loaded with contacts, but cavities for male contacts shall be provided.
For missing dimensions see 3.4.1.1 and 3.4.1.2.
1) Terminals and press-in pivots shall be in the grid, if the connector is straightened.
Coding may be achieved by an additional module on one or both ends of the connectors; see IEC 61076-4-102.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Renseignements sur le montage des embases
Plan de perỗage sur panneau
Dessins: vue sur le côté composants du panneau.
Les lettres placées à droite indiquent la rangée de contact.
Les chiffres placés au-dessus désignent la position du contact.
Il est recommandé d’utiliser des trous métallisés.
1) Pour tous les trous, pour le diamètre de trou voir tableau 3.
Figure 27 – Plan de perỗage sur panneau
Tableau 10 – Plan de perỗage sur panneau
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
3.7 Mounting information for fixed board connectors
Drawings: View on components side of panel.
The letters on the right-hand side designate the contact row.
The numbers above designate the position of the contact.
Plated-through holes are recommended.
1) All holes, hole diameter see table 3.
Figure 27 – Hole pattern on panels
Table 10 – Hole pattern on panels
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Renseignements sur le montage des fiches
Plan de perỗage sur cartes imprimộes
Dessins: vue sur le côté composants du panneau.
Les lettres placées à droite indiquent la rangée de contact.
Les chiffres placés au-dessus désignent la position du contact.
Il est recommandé d’utiliser des trous métallisés.
4) Zone de connecteur, pas d’autres composants autorisés des deux côtés de la carte imprimée ( -xx- ).
5) Pour tous les trous, diamètre de trou selon le tableau 3.
Figure 28 – Plan de perỗage sur cartes imprimộes ỉ 0,1
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
3.8 Mounting information for free board connectors
3.8.1 Hole pattern on printed boards
Drawings: View on components side of printed board.
The letters on the right-hand side designate the contact row.
The number above designates the position of the contact.
Plated-through holes are recommended.
4) Connector area, no other components permitted on both printed board sides ( -xx- ).
5) All holes, hole diameter according to table 3.
Figure 28 – Hole pattern on printed boards ỉ 0,1
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
4) Zone de connecteur, pas d’autres composants autorisés des deux côtés de la carte imprimée ( -xx- ).
5) Pour tous les trous, diamètre de trou selon le tableau 3.
Figure 29 – Plan de perỗage sur cartes imprimộes
Tableau 11 – Plan de perỗage sur cartes imprimộes
Recommended method of mounting
Free board connectors are available with either solder or press-in contacts, and they are mounted using press-in pivots According to IEC 60326-3, the terminations of these connectors are designed to fit into holes on the printed board, which are arranged on a 2.5 mm grid.
The fixed board connectors are provided either with:
– press-in and wrap contacts;
– press-in and wrap and mating area contacts.
The connector is securely attached to the press-in contacts, eliminating the need for fixing holes on the backplane The termination center lines are spaced at 2.5 mm or its multiples, making the fixed board connectors compatible with backplanes that have a grid dimension of 2.5 mm.
NOTE Information about manufacturers who have components qualified to this detail specification is given in the
Ratings and characteristics
Rated voltage: Contact/contact for fully loaded connector
Material group Pollution degree Rated voltage
NOTE Reference is made to table 14 of this specification, and table 4 of IEC 60664-1 listing the relation between creepage distances, pollution degree and material groups versus voltages r.m.s.
Current rating: 1 A at 70 °C for fully loaded connector (arrangement 1)
Insulation resistance: 10 6 MΩ min for PL1 and PL2
Printed board thickness: 1,6 mm to 3,2 mm for free board connector
1,6 mm min for fixed board connector
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence qui y est faite, constituent des dispositions valables pour la présente partie de la CEI 61076.
For dated references, subsequent amendments or revisions of these publications do not apply However, stakeholders involved in agreements based on this part of IEC 61076 are encouraged to consider applying the latest editions of the normative documents listed below For undated references, the latest edition of the referenced normative document applies Members of IEC and ISO maintain the registry of current International Standards.
CEI 60068-1:1988, Essais d'environnement – Première partie: Généralités et guide
CEI 60297-3:1984, Dimensions des structures mécaniques de la série de 482,6 mm (19 in) –
Troisième partie: Bacs et blocs enfichables associés
CEI 60326-3:1991, Cartes imprimées – Partie 3: Etudes et applications des cartes imprimées
CEI 60352-1:1997, Connexions sans soudure – Partie 1: Connexions enroulées – Règles générales, méthodes d'essai et guide pratique
CEI 60352-5:1995, Connexions sans soudure – Partie 5: Connexions insérées à force sans soudure – Règles générales, méthodes d'essai et guide pratique
CEI 60410:1973, Plans et règles d'échantillonnage pour les contrôles par attributs
CEI 60512 (toutes les parties) :Connecteurs pour équipements électroniques – Essais et mesures (voir la CEI 60512-1-100, 2001)
CEI 60664-1:1992, Coordination de l'isolement des matériels dans les systèmes (réseaux) à basse tension – Partie 1: Principes, prescriptions et essais
CEI 60917-2-2:1994, Ordre modulaire pour le développement des structures mécaniques pour les infrastructures électroniques – Partie 2: Spécification intermédiaire – Dimensions de coordination pour les interfaces des infrastructures au pas de 25 mm – Section 2:
Spécification particulière – Dimensions pour bacs, châssis, fonds de paniers, faces avant et unités enfichables.
CEI 61076-1:1995 specifies quality-assured connectors designed for use in analog applications involving direct current and low frequencies, as well as in digital applications that require high data transfer rates.
CEI 61076-4:1995 outlines quality-assured connectors designed for analog applications in direct current and low-frequency environments, as well as for high-speed digital data transfer applications.
Spécification intermédiaire: Connecteurs pour cartes imprimées
CEI 61076-4-102:1997 specifies quality-assured connectors designed for use in low-frequency analog applications and high-speed digital data transfer This standard outlines the requirements and testing methods to ensure reliable performance in various electronic applications.
Connectors for printed circuit boards Section 102: Specific requirements for two-part single-pin connectors designed for multiple uses on printed circuit boards, featuring advanced centering capabilities, coding, and coupling, with a metric pitch according to IEC 60917 standards.
Le marquage du connecteur et de son emballage doit être conforme à 2.6 de la CEI 61076-4.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Normative references
This section of IEC 61076 references several normative documents that are integral to its provisions For documents with specific dates, any amendments or revisions that occur afterward are not applicable However, it is advisable for parties involved in agreements related to this part of IEC 61076 to consider using the latest editions of the referenced normative documents In the case of undated references, the most recent version of the cited document is applicable Additionally, both IEC and ISO keep updated registers of valid International Standards.
IEC 60068-1:1988, Environmental testing – Part 1: General and guidance
IEC 60297-3:1984, Dimensions of mechanical structures of the 482,6 mm (19 in) series – Part
3: Subracks and associated plug-in units
IEC 60326-3:1991, Printed boards – Part 3: Design and use of printed boards
IEC 60352-1:1997, Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance
IEC 60352-5:1995, Solderless connections – Part 5: Solderless press-in connections –
General requirements, test methods and practical guidance
IEC 60410:1973, Sampling plans and procedures for inspections by attributes
IEC 60512 (all parts): Connectors for electronic equipment – Tests and measurements (see
IEC 60664-1:1992, Insulation coordination for equipment within low-voltage systems – Part 1:
IEC 60917-2-2:1994 outlines the modular order for developing mechanical structures for electronic equipment This standard specifies the interface coordination dimensions relevant to the 25 mm equipment practice It includes detailed specifications for essential components such as subracks, chassis, backplanes, front panels, and plug-in units, ensuring compatibility and standardization in electronic equipment design.
IEC 61076-1:1995, Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications – Part 1: Generic specification
IEC 61076-4:1995, Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications – Part 4: Sectional specification – Printed board connectors
IEC 61076-4-102:1997, Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications – Part 4: Printed board connectors –
Section 102 outlines the detailed specifications for two-part single-pole connectors designed for various applications on plug-in units These connectors feature pre-centering coding and early mating capabilities, adhering to a metric grid as specified by IEC 60917.
Marking
Marking of the connector and the package shall be in accordance with 2.6 of IEC 61076-4.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Les connecteurs, les boợtiers de connecteurs et les contacts conformes à la prộsente norme doivent correspondre au système suivant:
NOTE ô L ằ dộsigne une lettre. ô N ằ dộsigne un chiffre.
Pour commander des connecteurs conformes à la présente spécification particulière, on doit utiliser la désignation de type décrite en 1.5.
Numéro de la spécification particulière
Lettre indiquant le type selon le tableau 2
Boợtier de connecteur sans contact
475 Nombre de contacts/d’alvéoles de contact
Lettre indiquant le type de contact
Lettre indiquant le type de base des sorties
Insertion à force (CIF) CIF et connexion enroulée CIF et connexion enroulée et zone de contact
Lettre indiquant le niveau de contrôle
Niveau de contrôle B Niveau de contrôle G
Chiffre indiquant le niveau de performance
Niv de performance PL1 Niv de performance PL2 Niv de performance PL3
Chiffre indiquant la disposition des contacts
Contact individuel Connecteur complet selon 2.4.1 et 2.4.2
Boợtier de connecteur sans contact
Lettre et chiffre indiquant le type de sortie selon le tableau 3.
Chiffre indiquant le revêtement du contact
Non applicable Alliage or Alliage palladium avec flash d’or Alliage argent
Boợtier de connecteur selon 3.4 et 3.5
Boợtier de connecteur pour contacts spéciaux
Connecteur complet Contact individuel selon 3.4 et 3.5
Lettre indiquant la différenciation entre connecteur et boợtier de connecteur
The Model B connector features 85 female contacts with a gold alloy contact coating and force-inserted connection outputs It is designed for boards with a thickness ranging from 1.6 mm to 4 mm, offering performance level 2 and control level G.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
IEC type designation
Connectors, connector bodies and contacts according to this standard shall be designated by the following system:
Ordering information
To order connectors according to this detail specification, the type designation described in
Letter denoting the style according to table 2
475 Number of contacts or contact cavities
Letter denoting the type of contact
Letter denoting the basic type of termination
Press-in Press-in and wire wrap Press-in and wire wrap and mating area
Letter denoting the assessment level
Number denoting the performance level
Performance level PL1 Performance level PL2 Performance level PL3
Number denoting the contact arrangement
Individual contact Complete connector according to 2.4.1 and 2.4.2
Letter and number denoting the type of termination according to table 3
Number denoting the contact finish
Not applicable Gold alloy Palladium alloy with gold flash Silver alloy
Connector body according to 3.4 and 3.5 Connector body for special contacts
Complete connector Individual contact according to 3.4 and 3.5
Letter denoting the differentiation between connector and connector body
EXAMPLE – Connector style B, having 85 female contacts with gold alloy contact finish with press-in terminations Complete free board connector for boards with a thickness of 1,6 mm to
4 mm, with performance level 2 and assessment level G:
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
2.1.1 Disposition de contacts mâles pour fond de panier
Figure 1 illustrates a male contact arrangement for a basket background featuring a continuous grid with a 2.5 mm pitch This design allows the male contacts of both connectors to be positioned according to the grid in both height and width The housings of the plugs and sockets are specifically designed to accommodate a continuous grid of male contacts with a 2.5 mm pitch.
Boợtier de fiche: moulage pour connecteur femelle
Boợtier d’embase: moulage de reprise pour embase
Boợtier de reprise: reprise sans contacts
Contact FMLB: Contact sộquentiel ô Contact First Mate Last Break ằ
Figure 1 – Disposition de contacts mâles pour fond de panier
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Definitions
Backplane male contact arrangement
Figure 1 illustrates the arrangement of male contacts on a continuous 2.5 mm grid, allowing for male contacts to align on the pitch line of two connectors in both height and width The design of free and fixed board connector bodies accommodates this continuous 2.5 mm grid of male contacts.
Free board connector body: moulding for female connector
Fixed board connector body: moulded shroud for fixed board connector
Fixed board connector: shroud with contacts
Interface shroud: shroud without contacts
FMLB contact: First mate last break contact
Figure 1 – Backplane male contact arrangement
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
2.2 Tableau des modèles et des variantes
De 1 à 10 unités systèmes (SU) et de 12 à 475 lignes accouplées, pour les détails voir le tableau 2.
Tableau 2 – Disposition des contacts et nombre de contacts
Disposition des contacts 1) 1 Nombre de contacts 35 85 185 425 475
Disposition des contacts 1) 2 Nombre de contacts 18 43 93 214 239
Disposition des contacts 1) 3 Nombre de contacts 12 27 57 132 147
1) Disposition des contacts selon 2.4.1 et 2.4.2.
2) Ce modèle permet seulement une compatibilité limitée en aval avec les équipements habituels selon la
Lettre et chiffre d’identification pour les modèles de sorties
Sortie de CIF avec broche élastique sur fiche adaptée pour carte imprimée d'une épaisseur de 1,6 mm à 3,2 mm et trous métallisés de diamètre: 1 selon la CEI 60352-5
Sortie de CIF avec broche solide sur fiche adaptée pour carte imprimée d'une épaisseur de 1,6 mm à 3,2 mm et trous métallisés de diamètre: 1 selon la CEI 60352-5
Sortie de CIF avec broche élastique sur embase adaptée pour carte imprimée d'une épaisseur de 1,6 mm à 4,0 mm et trous métallisés de diamètre: 1 selon la CEI 60352-5
Sortie de CIF avec broche solide sur embase adaptée pour carte imprimée d'une épaisseur de 1,6 mm à 4,0 mm et trous métallisés de diamètre: 1 selon la CEI 60352-5
Sortie comme P-3 avec bornes 0,6 mm × 0,6 mm pour une connexion enroulée, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-4 avec bornes 0,6 mm × 0,6 mm pour une connexion enroulée, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-3 avec bornes 0,6 mm × 0,6 mm pour deux connexions enroulées, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-4 avec bornes 0,6 mm × 0,6 mm pour deux connexions enroulées, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-3 avec bornes 0,6 mm × 0,6 mm pour trois connexions enroulées, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
Sortie comme P-4 avec bornes 0,6 mm × 0,6 mm pour trois connexions enroulées, diamètre du fil:
0,25 mm selon la CEI 60352-1 et zone de contact mâle arrière pour connexion E/S
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Survey of styles and variants
From 1 to 10 system-units (SU) and from 12 to 475 mated lines, for details see table 2.
Table 2 – Contact arrangement and number of contacts
Contact arrangement 1) 1 Number of contacts 35 85 185 425 475
Contact arrangement 1) 2 Number of contacts 18 43 93 214 239
Contact arrangement 1) 3 Number of contacts 12 27 57 132 147
1) Contact arrangements according to 2.4.1 and 2.4.2.
2) This style allows a limited downward compatibility to equipment practice according to IEC 60297-3.
Identification letter and number for style of termination
Termination for press-in with compliant pin on free board connector to a printed board with a thickness of 1,6 mm to 3,2 mm, and through metallized holes, diameter: 1 according to
Termination for press-in with solid pin on free board connector to a printed board with a thickness of 1,6 mm to 3,2 mm, and plated through holes, diameter: 1 according to IEC 60352-5
Termination for press-in with compliant pin on fixed board connector to a printed board with a thickness of 1,6 mm to 4,0 mm, and through metallized holes, diameter: 1 according to
Termination for press-in with solid pin on fixed board connector to a printed board with a thickness of 1,6 mm to 4,0 mm, and plated through holes, diameter: 1 according to IEC 60352-5
0,6 mm × 0,6 mm for one wrap, wire diameter: 0,25 mm according to
IEC 60352-1 and male mating area for rear I/O connection
Termination as P-4 with posts 0,6 mm × 0,6 mm for one wrap, wire diameter: 0,25 mm according to IEC 60352-1 and male mating area for rear I/O connection
0,6 mm × 0,6 mm for two wraps, wire diameter: 0,25 mm according to
IEC 60352-1 and male mating area for rear I/O connection
Termination as P-4 with posts 0,6 mm × 0,6 mm for two wraps, wire diameter: 0,25 mm according to IEC 60352-1 and male mating area for rear I/O connection
0,6 mm × 0,6 mm for three wraps, wire diameter: 0,25 mm according to
IEC 60352-1 and male mating area for rear I/O connection
Termination as P-4 with posts 0,6 mm × 0,6 mm for three wraps, wire diameter: 0,25 mm according to IEC 60352-1 and male mating area for rear I/O connection
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Starting from the 25 mm multi-module, connector models can be stacked vertically without a specific order The arrangement of the pins typically matches that of the sockets.
Exemples de dispositions de fiches et d’embases.
– Modèles de connecteurs différents acceptable si le pliage et le décalage des connecteurs assemblés ne dépassent pas 0,5 mm
– Combinaisons interdites les conditions d’accouplement ne sont pas garanties car il n’y a pas de guide aux extrémités n = 4 n = 2 n = 4 n = 10 n = 10
Figure 2 – Fiches et embases pour disposition modulaire
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Information on application
Complete connectors (pairs)
The multi-module 25 mm connectors offer versatile stackable styles that can be arranged in varying heights Typically, the layout of the free board connectors aligns with that of the fixed board connectors.
Examples for arrangements of fixed and free board connectors.
– Different connector styles acceptable if bending and offsetting of assembled connectors do not exceed 0,5 mm
– Combinations not permitted mating conditions are not guaranteed because of missing guidance at the ends n = 4 n = 2 n = 4 n = 10 n = 10
Figure 2– Free and fixed board connectors for modular arrangement
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Planéité avant opération d’insertion à force sur fond de panier selon 3.4.1 et après insertion à force sur fond de panier selon 5.1.7.
Planéité avant opération d’insertion à force sur carte imprimée selon 3.5.1 et après insertion à force sur carte imprimée selon 5.1.7.
2.3.5 Blindage et continuité de masse
2.3.6 Types de base de sortie
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Fixed board connectors
Planarity before press-in operation to backplane according to 3.4.1 and after press-in to backplane according to 5.1.7.
Free board connectors
Planarity before press-in operation to printed board according to 3.5.1 and after press-in to printed board according to 5.1.7.
Accessories
Shielding/grounding
Basic type of termination
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Face d’accouplement Plan de perỗage
NOTE Pour les informations de montage, voir 3.7.1 (plan de perỗage).
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Contact arrangements
Fixed board connectors
NOTE For mounting information see 3.7.1 (hole pattern).
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
NOTE Pour les informations de montage, voir 3.8.1 (plan de perỗage).
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Free board connectors
NOTE For mounting information see 3.8.1 (hole pattern).
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
Toutes les dimensions sont exprimées en millimètres.
The drawings are depicted in first-angle projection The shape of the connectors may differ from what is shown in the following figures, provided that the specified dimensions remain unaffected.
Les renseignements concernant la flèche en 3.3.3 et 5.1.7 sont valables pour les conditions de livraison La flèche acceptable pour un connecteur monté est indiquée en 5.1.7.
Les dimensions manquantes peuvent être choisies conformément aux caractéristiques communes et à l’utilisation prévue.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
General
All dimensions are in millimetres.
The drawings utilize first angle projection, and while the shape of the connectors may vary from the figures provided, the specified dimensions must remain unaffected.
The information about the bending in 3.3.3 and 5.1.7 is valid for the condition of delivery The permissible bending of the mounted connector is stated in 5.1.7.
Missing dimensions can be chosen according to the common characteristics and the intended use.
LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU.
3.2 Vue isométrique et caractéristiques communes
Profondeur de plan de référence
Par exemple rails guides pour carte imprimée
Carte imprimée Axes des connexions CIF
Bornes de contact pas de 2,5
Largeur du plan de référence
Contacts mâles au pas de 2,5 n × 25