NORME CEI INTERNATIONALE IEC INTERNATIONAL 60598 2 17 STANDARD Première édition First edition 1984 Luminaires – Deuxième partie Règles particulières Section dix sept – Luminaires pour éclairage des sc[.]
Trang 1NORME CEI
INTERNATIONAL 60598-2-17
First edition 1984
Luminaires –
Deuxième partie:
Règles particulières
Section dix-sept – Luminaires pour éclairage
des scènes de théâtre, pour prises de vues
de télévision et de cinéma (à l'extérieur
et à l'intérieur)
Luminaires –
Part 2:
Particular requirements
Section Seventeen – Luminaires for stage lighting,
television and film studios (outdoor and indoor)
Reference number CEI/IEC 60598-2-17: 1984
Trang 2Les publications de la CEI sont numérotées à partir de
60000 dès le 1er janvier 1997.
Publications consolidées
Les versions consolidées de certaines publications de
la CEI incorporant amendements sont disponibles Par
exemple, les numéros d'édition 1.0, 1.1 et 1.2
indiquent respectivement la publication de base, la
publication de base incorporant l'amendement 1, et la
publication de base incorporant les amendements 1
et 2.
Validité de la présente publication
Le contenu technique des publications de la CEI est
constamment revu par la CEI afin qu'il reflète l'état
actuel de la technique.
Des renseignements relatifs à la date de
reconfirmation de la publication sont disponibles dans
le Catalogue de la CEI.
Les renseignements relatifs à ces révisions, à
l'établis-sement des éditions révisées et aux amendements
peuvent être obtenus auprès des Comités nationaux de
la CEI et dans les documents ci-dessous:
• Bulletin de la CEI
• Annuaire de la CEI
Accès en ligne`
• Catalogue des publications de la CEI
Publié annuellement et mis à jour régulièrement
(Accès en ligne)*
Terminologie, symboles graphiques
et littéraux
En ce qui concerne la terminologie générale, le lecteur
se reportera à la CEI 60050: Vocabulaire
Electro-technique International (VEI).
Pour les symboles graphiques, les symboles littéraux
et les signes d'usage général approuvés par la CEI, le
lecteur consultera la CEI 60027: Symboles littéraux à
utiliser en électrotechnique, la CEI 60417: Symboles
graphiques utilisables sur le matériel Index, relevé et
compilation des feuilles individuelles, et la CEI 60617:
Symboles graphiques pour schémas.
Publications de la CEI établies par
le même comité d'études
L'attention du lecteur est attirée sur les listes figurant
à la fin de cette publication, qui énumèrent les
publications de la CEI préparées par le comité
d'études qui a établi la présente publication.
Voir adresse «site web» sur la page de titre.
As from the 1st January 1997 all IEC publications are issued with a designation in the 60000 series.
Consolidated publications
Consolidated versions of some IEC publications including amendments are available For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2.
Validity of this publication
The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology.
Information relating to the date of the reconfirmation of the publication is available in the IEC catalogue.
Information on the revision work, the issue of revised editions and amendments may be obtained from IEC National Committees and from the following IEC sources:
• IEC Bulletin
On-line access*
• Catalogue of IEC publications
Published yearly with regular updates (On-line access)*
Terminology, graphical and letter symbols
For general terminology, readers are referred to IEC 60050: International Electrotechnical Vocabulary
(IEV).
For graphical symbols, and letter symbols and signs approved by the IEC for general use, readers are
referred to publications IEC 60027: Letter symbols to
be used in electrical technology, IEC 60417: Graphical symbols for use on equipment Index, survey and compilation of the single sheets and IEC 60617:
Graphical symbols for diagrams.
IEC publications prepared by the same technical committee
The attention of readers is drawn to the end pages of this publication which list the IEC publications issued
by the technical committee which has prepared the present publication.
See web site address on title page.
Trang 3IEC• CODE PRIX
INTERNATIONAL 60598-2-17
First edition 1984
Luminaires —
Deuxième partie:
Règles particulières
Section dix-sept — Luminaires pour éclairage
des scènes de théâtre, pour prises de vues
de télévision et de cinéma (à l'extérieur
et à l'intérieur)
Luminaires —
Part 2:
Particular requirements
Section Seventeen — Luminaires for stage lighting,
television and film studios (outdoor and indoor)
© IEC 1984 Droits de reproduction réservés —Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in utilisée sous quelque forme que ce soit et par aucun any form or by any means, electronic or mechanical, procédé, électronique ou mécanique, y compris la photo- including photocopying and microfilm, without permission in copie et les microfilms, sans l'accord écrit de l'éditeur writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
Commission Electrotechnique Internationale
International Electrotechnical Commission
McIH4yHapoAHaR 3neKTpoTeXHH4ecKaR KOMHCCHA
Pour prix, voir catalogue en vigueur
Trang 4Pages
Articles
17.1 Domaine d'application 6
17.2 Règles générales sur les essais 6
17.3 Définitions 6
17.4 Classification des luminaires 6
17.5 Marquage 6
17.6 Construction 8
17.7 Lignes de fuite et distances dans l'air 10
17.8 Dispositions en vue de la mise à la terre 10
17.10 Câblage externe et interne 12
17.11 Protection contre les chocs électriques 12
17.12 Essais d'endurance et essais thermiques 12
17.13 Résistance aux poussières et à l'humidité 12
17.14 Résistance d'isolement et rigidité diélectrique 12
17.15 Résistance à la chaleur, au feu et aux courants de cheminement 14
Trang 5598-2-17 © IEC 1984 — 3 —
CONTENTS
Page
Clause
17.2 General test requirements 7
17.4 Classification of luminaires 7
17.7 Creepage distances and clear ances 11
17.8 Provision for earthing 11
17.10 External and internal wiring 13
17.11 Protection against electric shock 13
17.12 Endurance tests and thermal tests 13
17.13 Resistance to dust and moisture 13
17.14 Insulation resistance and electric strength 13
17.15 Resistance to heat, fire and tracking 15
Trang 6Règle des Six Mois Rapport de vote 34D(BC)88 34D(BC)97
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
LUMINAIRES Deuxième partie: Règles particulières Section dix-sept — Luminaires pour l'éclairage des scènes de théâtre, pour
prises de vues de télévision et de cinéma (à l'extérieur et à l'intérieur)
PRÉAMBULE 1) Les décisions ou accords officiels de la CE I en ce qui concerne les questions techniques, préparés par des Comités d'Etudes ó sont
représentés tous les Comités nationaux s'intéressant à ces questions, expriment dans la plus grande mesure possible un accord
international sur les sujets examinés.
2) Ces décisions constituent des recommandations internationales et sont agréées comme telles par les Comités nationaux.
3) Dans le but d'encourager l'unification internationale, la CEI exprime le voeu que tous les Comités nationaux adoptent dans leurs
règles nationales le texte de la recommandation de la CEI, dans la mesure ó les conditions nationales le permettent Toute
divergence entre la recommandation de la C El et la règle nationale correspondante doit, dans la mesure du possible, être indiquée
en termes clairs dans cette dernière.
PRÉFACE
La présente norme a été préparée par le Sous-Comité 34D: Luminaires, du Comité d'Etudes n° 34 de la
CE I: Lampes et équipements associés
Le texte de cette norme est issu des documents suivants:
Pour de plus amples renseignements, consulter le rapport de vote mentionné dans le tableau
ci-dessus
Cette publication doit être lue conjointement avec la Publication 598-1 de la CEI: Luminaires,
Pre-mière partie: Règles générales et généralités sur les essais
Trang 7Six Months' Rule Report on Voting 34D(CO)88 34D(CO)97
598-2-17 © IE C 1984 — 5 —
INTERNATIONAL ELECTROTECHNICAL COMMISSION
LUMINAIRES Part 2: Particular requirements Section Seventeen — Luminaires for stage lighting, television and film
studios (outdoor and indoor)
FOREWORD 1) The formal decisions or agreements of the I E C on technical matters, prepared by Technical Committees on which all the National
Committees having a special interest therein are represented, exp ress, as nearly as possible, an international consensus of opinion
on the subjects dealt with.
2) They have the form of recommendations for international use and they are accepted by the National Committees in that
sense.
3) In order to promote international unification, the I E C expresses the wish that all National Committees should adopt the text of
the I EC recommendation for their national rules in so far as national conditions will permit Any divergen ce between the I EC
recommendation and the corresponding national rules should, as far as possible, be clearly indicated in the latter.
PREFACE
This standard has been prepared by Sub-Committee 34D: Luminaires, of I EC Technical Committee
No 34: Lamps and Related Equipment
The text of this standard is based upon the following documents:
Further information can be found in the Report on Voting indicated in the table above
This publication should be read in conjunction with I EC Publication 598-1: Luminaires, Part 1:
General Requirements and Tests
Trang 8LUMINAIRES Deuxième partie: Règles particulières Section dix-sept — Luminaires pour l'éclairage des scènes de théâtre, pour
prises de vues de télévision et de cinéma (à l'extérieur et à l'intérieur)
17.1 Domaine d'application
Cette section de la deuxième partie de la Publication 598 de la CE I détaille les prescriptions
applicables aux luminaires pour les scènes de théâtre, les prises de vues de télévision et de cinéma (y
compris des projecteurs à faisceaux intensifs et extensifs), à utiliser avec des lampes à filament de
tungstène, des lampes tubulaires à fluorescence ou autres lampes à décharge, pour des tensions
d'alimentation ne dépassant pas 1 000 V Elle doit être lue conjointement avec les sections de la
première partie auxquelles il est fait référence
Note — Les fourches (étriers) de suspension font partie du luminaire Les dispositifs de suspension tels que trépieds, girafes et
supports télescopiques ne font pas partie du luminaire Les ballasts, s'ils sont nécessaires, peuvent être incorporés
dans les luminaires ou montés séparément.
17.2 Règles générales sur les essais
Les dispositions de la section zéro de la Publication 598-1 sont applicables Les essais dont le
détail est indiqué dans chaque section appropriée de la première partie doivent être exécutés dans
l'ordre spécifié dans la présente section de la deuxième partie
17.3 Définitions
Pour les besoins de la présente section, les définitions de la section un de la Publication 598-1 sont
applicables
17.4 Classification des luminaires
Les luminaires doivent être en conformité avec les dispositions de la section deux de la
Publi-cation 598-1
17.5 Marquage
Les dispositions de la section trois de la Publication 598-1 sont applicables en même temps que
les prescriptions des paragraphes 17.5.1 à 17.5.7
17.5.1 Dans les cas ó la conception du luminaire impose certaines restrictions, dans son utilisation, les
données suivantes doivent être marquées sur le luminaire:
a) l'indication du «haut» du luminaire;
b) les positions d'utilisation ou le domaine angulaire projetés;
c) les possibilités de montage (ou la référence à un document détaillant les possibilités de
montage)
Trang 9598-2-17 © IEC 1984 — 7
LUMINAIRES Part 2: Particular requirements Section Seventeen — Luminaires for stage lighting, television and film
studios (outdoor and indoor)
17.1 Scope
This section of Pa rt 2 of I EC Publication 598 specifies requirements for stage, television and film
studio luminaires (including spot and floodlighting projectors), for use with tungsten filament,
tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V It is to be
read in conjunction with those sections of Pa rt 1 to which reference is made
Note — A hanger (stirrup) is a part of the luminaire Supporting devices such as tripods, telescopic booms and suspensions
are not pa rts of the luminaire Where applicable, ballasts ire built into or mounted separately from the
lumi-naires.
17.2 General test requirements
The provisions of Section Zero of Publication 598-1 apply The tests described in each
appro-priate section of Part 1 shall be carried out in the order listed in this section of Pa rt 2
17.3 Definitions
For the purposes of this section, the definitions of Section One of Publication 598-1 apply
17.4 Classification of luminaires
Luminaires shall be classified in accordance with the provisions of Section Two of
Publica-tion 598-1
17.5 Marking
The provisions of Section Three of Publication 598-1 apply, together with the requirements of
Sub-clauses 17.5.1 to 17.5.7
17.5.1 Where the luminaire design imposes restrictions of use, the following information shall be
marked on the luminaire:
a) an indication of the "top" of the luminaire;
b) the designed positions or range of angles of use;
c) mounting arrangements (or reference to a document which specifies the mounting
arrange-ments)
Trang 1017.5.2 Les luminaires qui sont exemptés des dispositions du paragraphe 17.6.1 doivent porter
l'avertis-sement suivant clairement marqué à l'extérieur du luminaire:
«Isoler le luminaire de tous les pôles du réseau d'alimentation avant de l'ouvrir»
17.5.3 La température ambiante maximale nominale t a doit être clairement marquée sur le
lumi-naire
17.5.4 Les distances minimales des matières inflammables à toute surface externe du luminaire doivent
être clairement marquées sur le luminaire (pour prévenir l'inflammation des matières
inflamma-bles)
17.5.5 Les luminaires pour certains types de lampes à décharge à haute pression doivent, si nécessaire,
être marqués de l'avertissement suivant de ne pas les ouvrir immédiatement après l'extinction:
«NE PAS OUVRIR AVANT X SECONDES APRÈS L'EXTINCTION»
Note — La valeur «X» est spécifiée par le fabricant (voir paragraphe 17.6.2).
17.5.6 Un mode d'emploi doit être fourni avec chaque luminaire et doit contenir des données
concer-nant la température des surfaces externes du luminaire:
a) après 5 min de fonctionnement;
b) lorsque l'équilibre thermique est atteint
17.5.7 Le mode d'emploi fourni avec le luminaire doit aussi contenir un avertissement que:
«a) les écrans de protection (voir paragraphe 17.6.3), les lentilles ou les filtres à ultraviolets
doivent être remplacés s'ils sont visiblement endommagés au point que leur efficacité en soit
diminuée, par exemple par des fêlures ou des rayures profondes;
b) la lampe doit être remplacée si elle a été endommagée ou déformée par la chaleur.»
17.6 Construction
Les dispositions de la section quatre de la Publication 598-1 sont applicables en même temps que
les prescriptions des paragraphes 17.6.1 à 17.6.6
17.6.1 La conception du luminaire doit être telle qu'il ne soit pas possible d'insérer une lampe dans une
douille sous tension Cette prescription ne s'applique toutefois pas aux luminaires pour lampes
d'une puissance nominale égale ou inférieure à 250 W
17.6.2 Les luminaires pour certains types de lampes à décharge à haute pression pour lesquelles le
fabricant déclare qu'il existe un risque d'explosion doivent être munis d'un dispositif bloquant
l'accès immédiat à la lampe après l'extinction ou doivent être marqués en conformité avec les
dispositions du paragraphe 17.5.5
17.6.3 Le luminaire doit être muni d'un écran de protection qui retienne les éclats de verre ou de quartz
dans l'éventualité du bris de la lampe L'écran ne doit pas pouvoir être détaché du luminaire Les
ouvertures doivent être pratiquées de telle manière qu'aucune partie d'une lampe brisée ne puisse
quitter le luminaire par une trajectoire directe
Le contrôle s'effectue par l'essai suivant:
Essai:
Le luminaire est mis en fonctionnement à la puissance nominale, dans la position d'usage normal
la plus défavorable, jusqu'à ce que l'équilibre thermique soit atteint Cinq couches de gaze de coton
sont placées sur un support en bois à une distance de 500 mm au-dessous de l'enveloppe externe du
luminaire On fait ensuite exploser la lampe, par exemple dans le cas de lampes à filament de
tungstène, en augmentant brusquement la tension appliquée à la lampe d'environ 30%