Tiêu đề Railway Applications — Fixed Installations — D.C. Switchgear — Part 7-2: Measurement, Control And Protection Devices For Specific Use In D.C. Traction Systems — Isolating Current Transducers And Other Current Measuring Devices
Trường học British Standards Institution
Chuyên ngành Railway Applications
Thể loại British Standard
Năm xuất bản 2003
Thành phố London
Định dạng
Số trang 12
Dung lượng 287,08 KB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

BRITISH STANDARD BS EN 50123 7 2 2003 Railway applications — Fixed installations — D C switchgear — Part 7 2 Measurement, control and protection devices for specific use in d c traction systems — Isol[.]

Trang 1

BRITISH STANDARD BS EN

50123-7-2:2003

Railway applications —

Fixed installations —

D.C switchgear —

Part 7-2: Measurement, control and

protection devices for specific use in

d.c traction systems — Isolating

current transducers and other current

measuring devices

The European Standard EN 50123-7-2:2003 has the status of a

British Standard

ICS 29.280

12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:

Trang 2

This British Standard, was

published under the authority

of the Standards Policy and

Strategy Committee on

11 July 2003

© BSI 11 July 2003

ISBN 0 580 42253 4

National foreword

This British Standard is the official English language version of

EN 50123-7-2:2003 It supersedes BS EN 50123-7-2:1999 which is withdrawn The UK participation in its preparation was entrusted by Technical Committee GEL/9, Railway electrotechnical applications, to Subcommittee GEL/9/3, Fixed equipment, which has the responsibility to:

A list of organizations represented on this subcommittee can be obtained on request to its secretary.

Cross-references

The British Standards which implement international or European

publications referred to in this document may be found in the BSI Catalogue

under the section entitled “International Standards Correspondence Index”, or

by using the “Search” facility of the BSI Electronic Catalogue or of British

Standards Online.

This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application.

Compliance with a British Standard does not of itself confer immunity from legal obligations.

— aid enquirers to understand the text;

— present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the

UK interests informed;

— monitor related international and European developments and promulgate them in the UK.

Summary of pages

This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 8, an inside back cover and a back cover.

The BSI copyright date displayed in this document indicates when the document was last issued.

Amendments issued since publication

Trang 3

EUROPEAN STANDARD EN 50123-7-2

NORME EUROPÉENNE

EUROPÄISCHE NORM February 2003

CENELEC

European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members

Ref No EN 50123-7-2:2003 E

ICS 29.280 Supersedes EN 50123-7-2:1999

English version

Railway applications – Fixed installations – D.C switchgear Part 7-2: Measurement, control and protection devices

for specific use in d.c traction systems – Isolating current transducers and other current measuring devices

Applications ferroviaires –

Installations fixes –

Appareillage à courant continu

Partie 7-2: Appareils de mesure,

de commande et de protection pour

usage spécifique dans les systèmes

de traction à courant continu –

Transducteurs et autres appareils

de mesure de courant

Bahnanwendungen – Ortsfeste Anlagen – Gleichstrom-Schalteinrichtungen Teil 7-2: Mess-, Steuer- und Schutzeinrichtungen in Gleichstrom-Bahnanlagen –

Messumformer für Strommessung und andere Strommesseinrichtungen

This European Standard was approved by CENELEC on 2002-09-01 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration

Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member

This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions

CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom

Trang 4

Foreword

This European Standard was prepared by SC 9XC, Electric supply and earthing systems for public transport equipment and ancillary apparatus (fixed installations), of the Technical Committee CENELEC TC 9X, Electrical and electronic applications for railways

The text of the draft was submitted to the Unique Acceptance Procedure and was approved

by CENELEC as EN 50123-7-2 on 2002-09-01

This European Standard supersedes EN 50123-7-2:1999

The following dates were fixed:

- latest date by which the EN has to be implemented

at national level by publication of an identical

- latest date by which the national standards conflicting

This Part 7-2 is to be used in conjunction with EN 50123-1:2003

_

Trang 5

- 3 - EN 50123-7-2:2003

Contents

Page

1 Scope 4

2 Normative references 4

3 Definitions 4

4 Service requirements 4

5 Characteristics 5

5.1 Electrical characteristics 5

5.2 Mechanical characteristics 6

6 Information to be exchanged between purchaser and supplier 7

7 Tests 7

7.1 Dielectric tests 7

7.2 Calibration test 7

7.3 Other tests 8

7.4 EMC tests 8

Trang 6

1 Scope

This European Standard gives the requirements for isolating current transducers and other current measuring devices used in d.c railway applications, fixed installations

This transducer is normally positioned between the sensor in the live switchboard conductor or rail and the secondary device, giving galvanic insulation between the input and the output

This European Standard incorporates by dated or undated references, provisions from other publications These normative references are cited at the appropriate places in the text and the publications are listed hereafter For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision For undated references the latest edition of the publication referred to applies (including amendments)

See EN 50123-1:2003

3 Definitions

For the purposes of this European standard the terms and definitions given in EN 50123-1 apply

Where the equipment described in this standard is mounted on devices or in assemblies covered by the EN 50123 series , then the service conditions of the devices or assemblies apply

In this European standard the pollution degree PD4 and overvoltage categories (see notes

to Table 1 of EN 50123-1), as described in EN 50124-1, are considered to be normal conditions

The normal service requirements are given in Annex B of EN 50123-1

5 Characteristics

5.1 Electrical characteristics

5.1.1 General

The isolating transducer has an insulation level between its primary terminals and secondary terminals which is the same as that of the main circuit

An isolating transducer shall have an insulation level in accordance with Table 1 of

EN 50123-1

Trang 7

- 5 - EN 50123-7-2:2003

Transducers shall be suitable for use providing inputs to measuring devices and/or protection devices The output impedance, accuracy, linearity of response and phase shift between input and output shall be compatible with its designated application

The purchaser shall indicate whether the transducer is to be used for measurement purposes

or for protection or both He shall also indicate the accuracy range desired

The sensor(s) for the current transducers shall be of one of the types described in 3.1.8 to 3.1.12 of EN 50123-1 It may be of a design suitable for temporary insertion or permanent connection onto live primary circuit conductors

The frequency range shall be from d.c to a minimum of 1 kHz

A current transducer shall operate correctly up its continuous thermal current Ith, which shall be at maximum ambient temperature, at two times the specified main or primary

circuit thermal current and shall be able to withstand INcw of the main or primary circuit for

the time specified Rated accuracy, within specified tolerances, shall apply within the range

from 0 to 1,2 Ith for measuring transducers and in the range from 0 to 2 Ith for protection transducers Performance requirements different from these shall be by agreement between supplier and purchaser

NOTE Attention should be paid to EMC emissions and immunity in locating the sensor

Preferred secondary signal may either be a voltage in the range from 0 V to 10 V or a current in the range from 4 mA to 20 mA (e.g 0 mA to 20 mA, 4 mA to 20 mA or

0 mA to 10 mA)

When the transducer uses an auxiliary power supply, means shall be provided to indicate that the power supply is not available If the principle of operation of the transducer is electronic, then self-checking means shall be provided The need for this requirement depends on the duty of the transducer and shall be specified by the purchaser

Due consideration shall be given to providing adequate protection of the transducer and associated circuits against overloads and short circuits Care shall be taken that inductive

circuits can alter the inherent di/dt response

5.1.2 Isolating transducer requirements

The following requirements characterise the isolating transducer:

Trang 8

h) accuracy (± %);

n) loss of auxiliary power signal 1)

o) electronic circuitry self checking required 1)

5.1.3 d.c shunt requirements

The following requirements characterise the shunt:

5.1.4 Hall effect sensor requirements

The same as for an isolating transducer with the addition of

p) number of Hall effect devices

5.2 Mechanical characteristics

The enclosure of the transducer may be metal enclosed, or of insulating material Both may

have earthed metal mounting feet

Mechanical stress caused by the operation of other devices within the switchgear or

adjacent to the transducer shall not cause damage or loss of accuracy to the transducer

Transducers intended for location near live conductors shall be provided with an insulated

enclosure, unless alternative arrangements are agreed with the purchaser

1) Requirement to be specified by the purchaser.

2) Refers to insulation mounting, if any.

Trang 9

- 7 - EN 50123-7-2:2003

6 Information to be exchanged between purchaser and supplier

The supplier shall give the requirements specified in 5.1.2, 5.1.3 and 5.1.4 as far as applicable and the purchaser shall confirm or complement these requirements as necessary

If requested the following information shall be provided by the supplier in addition to the requirements specified above:

a) insulation levels of the circuits;

b) short time withstand current of the primary circuit INcw in kA;

c) overload capability (current and time);

d) linearity range and tolerances;

e) thermal deviation of the secondary signal expressed per °C;

g) residual output (expressed in %) of the last signal, if any, value of the offset current (in order to control the transducer);

h) if inversion of polarity in the auxiliary supply may damage the device;

i) burden;

j) value of the input impedance of the device connected to the secondary side of the transducer

A rating plate shall be provided with at least the following: conversion ratio, insulation level, serial number and manufacturer’s name

7 Tests

7.1 Dielectric tests

Power-frequency voltage withstand test shall be a routine test The voltage shall be applied between all auxiliary power supply terminals and the primary side and between the secondary terminals and the auxiliary power supply

An impulse test for transducers used on systems having UNm greater than 2,5 kV, is a type test made between input terminals and all other terminals including the transducer mounting feet

Power frequency test values shall be taken from Table 1 of EN 50123-1

7.2 Calibration test

This is a routine test

Linearity shall be checked against the declared accuracy in the range from 0 and 1, 2 Ith

when used for measurement purposes or in the declared accuracy range (at least from 0 to

2 Ith)when used for protection purposes

Trang 10

The purpose of this test is to verify declared accuracy over the specified operating range and record variations When voltage variations of the auxiliary can affect the calibration, the test shall be repeated at the maximum auxiliary supply voltage limits

7.3 Other tests

A type test shall be carried out to check that di/dt is correctly followed

This may be performed as a high frequency input current test, where the di/dt at I = 0 is to

be at least equal to the highest di/dt response required by the detecting device

7.4 EMC tests

EMC tests shall be in accordance with the EN 50121 series

Trang 11

blank

Trang 12

389 Chiswick High Road

London

W4 4AL

BSI is the independent national body responsible for preparing British Standards It presents the UK view on standards in Europe and at the international level It is incorporated by Royal Charter.

Revisions

British Standards are updated by amendment or revision Users of British Standards should make sure that they possess the latest amendments or editions.

It is the constant aim of BSI to improve the quality of our products and services

We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover

Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996 7400.

BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards.

Buying standards

Orders for all BSI, international and foreign standards publications should be addressed to Customer Services Tel: +44 (0)20 8996 9001

Fax: +44 (0)20 8996 7001 Email: orders@bsi-global.com Standards are also available from the BSI website at http://www.bsi-global.com.

In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested.

Information on standards

BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service Various BSI electronic information services are also available which give details on all its products and services Contact the Information Centre

Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: info@bsi-global.com Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards For details

of these and other benefits contact Membership Administration

Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001

Email: membership@bsi-global.com.

Information regarding online access to British Standards via British Standards Online can be found at http://www.bsi-global.com/bsonline.

Further information about BSI is available on the BSI website at http://www.bsi-global.com.

Copyright

Copyright subsists in all BSI publications BSI also holds the copyright, in the

UK, of the publications of the international standardization bodies Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI.

This does not preclude the free use, in the course of implementing the standard,

of necessary details such as symbols, and size, type or grade designations If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained.

Details and advice can be obtained from the Copyright & Licensing Manager Tel: +44 (0)20 8996 7070 Fax: +44 (0)20 8996 7553

Email: copyright@bsi-global.com.

Ngày đăng: 14/04/2023, 08:35

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN