Aerospace series - Connectors, optical, rectangular, rack and
panel, multicontact, 1,25 diameter ferrule, with removable alignment sleeve holder - Part 001: Technical specification
Série aérospatiale - Connecteurs, optiques, rectangulaires,
à contacts multiples, rackables, férule diamètre 1,25,
équipés d'un porte sleeve démontable - Partie 001:
Spécification technique
Luft- und Raumfahrt - Optischer Rechtecksteckverbinder, Gehäuse, Einschub, Steckverbinder, Multipin, Ferrulendurchmesser 1,25 mm, demontierbarer Zentrierhülsenhalter - Teil 001: Technische
Lieferbedingungen
This European Standard was approved by CEN on 11 July 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
C O M I T É E U R O P É E N D E N O R M A L I S A T I O N
E U R O P Ä I S C H E S K O M I T E E F Ü R N O R M U N G
Trang 4Contents Page
Foreword 3
Introduction 4
1 Scope 4
2 Normative references 4
3 Terms and definitions 5
4 Description 5
5 Design 6
6 Definition drawings 6
7 Tests 16
8 Quality assurance 19
9 Designation and marking 23
Trang 5Foreword
This document (EN 4640-001:2009) has been prepared by the Aerospace and Defence Industries Association
of Europe - Standardization (ASD-STAN)
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD,
prior to its presentation to CEN
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by August 2009, and conflicting national standards shall be withdrawn at
the latest by August 2009
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom
Trang 6Introduction
This family of fibre optic connectors is derived from ARINC Specification 600 connectors It is suitable for use
on aerospace onboard applications It provides easy access for optical contact end face cleaning
The optical contacts are capable of accepting single cable sizes up to a maximum of 2 mm outside diameter
1 Scope
This standard specifies the general characteristics, the conditions for qualification, acceptance and quality
assurance, as well as the test programs and groups for rectangular multipin fibre optic connectors
2 Normative references
The following referenced documents are indispensable for the application of this document For dated
references, only the edition cited applies For undated references, the latest edition of the referenced
document (including any amendments) applies
EN 2591-100*, Aerospace series — Elements of electrical and optical connection — Test methods —
Part 100: General
EN 3197, Aerospace series — Installation of aircraft electrical and optical interconnection systems 1
EN 3909, Aerospace series — Test fluids and test methods for electric components and sub-assemblies
EN 4639-101, Aerospace series — Connectors, optical, rectangular, modular, multicontact, 1,25 mm diameter
ferrule, with removable alignment sleeve holder — Part 101: Optical contact for cable EN 4641-100 —
Operating temperatures between – 65 °C and 125 °C — Product standard
EN 4640-002, Aerospace series — Connectors, optical, rectangular, rack and panel, multicontact, 1,25 diameter
ferrule, with removable alignment sleeve holder — Part 002: Specification of performance and contact
arrangements
EN 4640-003, Aerospace series — Connectors, optical, rectangular, rack and panel, multicontact, 1,25 diameter
ferrule, with removable alignment sleeve holder — Part 003: Plug optical connector — Product standard
EN 4640-004, Aerospace series — Connectors, optical, rectangular, rack and panel, multicontact, 1,25 diameter
ferrule, with removable alignment sleeve holder — Part 004: Receptacle optical connector — Product standard
EN 9133, Aerospace series — Quality management systems — Qualification procedure for aerospace
standard parts
ARINC Specification 600, Air Transport Avionics Equipment Interfaces 2
MIL-I-81969/14, Installing and removal tools, connector electrical contact, type III, class 2, composition B 3
* And all parts quoted in this standard
1 Published as ASD Prestandard at the date of publication of this standard
2 Published by: AERONAUTICAL RADIO, INC 2551 Riva road, Annapolis, Maryland 21401-7435 USA
3 Published by: Department of Defence (DOD), the Pentagon, Washington, D.C 20301 USA
Trang 73 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 2591-100 apply
4 Description
4.1 General
This document describes an optical connector insert to be installed in plug and receptacle housings
Plug and receptacle housings conform to ARINC Specification 600
The precise alignment of the optical contacts is accomplished by alignment sleeves held in a removable sleeve holder
The plug connector contain male insert as specified in EN 4640-003
The receptacles connector contain female insert as specified in EN 4640-004
The female insert is composed of an insert and a removable sleeve holder as specified in EN 4640-004
The sleeve holder is delivered with the female insert It is considered as a part of the female insert (specific design per manufacturer)
The sleeve holder can be supplied separately only for repair purpose
The optical contact is in accordance with EN 4639-101
The connectors are keyed as specified in ARINC Specification 600
Connector type designation as specified in ARINC Specification 600
4.2 Receptacle
Receptacle description as specified in ARINC Specification 600
4.3 Plug
Plug description as specified in ARINC Specification 600
4.4 Materials and surface treatment
Trang 84.4.3 Optical contacts and alignment sleeves
The contacts shall be of suitable materials as specified in EN 4639-101
The optical alignment sleeves shall be of suitable materials as specified in EN 4640-002
The optical contacts are sprung-loaded The spring force is defined in the product standard (EN 4639-101)
4.4.4 Metallic or non-metallic materials
The materials used for inserts, seals and grommets shall have a hardness and mechanical characteristics
consistent with the required use
5 Design
5.1 Housing
The connector housing design as specified in ARINC Specification 600
5.2 Connector inserts
The connector insert carrying the optical contacts shall be in hard material and have a cross section and radii
such that no cracks, flaking or breaks can occur in normal operation
The mechanical contacts retention system shall be integrated in the connector insert
Sealing of the rear face of the connector insert can be provided by a grommet adapted to the external
diameter of the cable
The design shall permit individual installation of the contacts without removal of the connector insert
Fitting and removal of the contacts shall be from the rear For ease of operation, tools as per MIL-I-81969/14-03
(P/N for size 16) may be used
Contact position identification shall be permanent and contrasted on the rear face of the insert or grommet
Trang 91 Receptacle connector 5 Mechanical bottom of receptacle
2 Mechanical bottom of plug 6 Plug connector
3 Front face of the insert 7 ∅ Pin cavity position A
Trang 103 Mechanical bottom of the receptacle
NOTE Other dimensions in accordance with ARINC Specification 600
Figure 2
Trang 11The mating dimensions of plug (free position) are shown in Figure 3
Key
1 (unmated position)
2 Mechanical bottom of the plug
NOTE Other dimensions in accordance with ARINC Specification 600
Figure 3 6.5.1 Receptacle with female insert and plug with male insert
The displacement of the optical contact in the connector is shown in Figure 4
Dimensions and tolerances are in millimetres
Mating position Key
1
Trang 126.5.2 Receptacle connector
Key
1 # 22 Electrical contact 6 Bloc side
2 Sleeve holder 7 Rack side
3 # 12 Electrical contact 8 Plug
4 # 16 Electrical contact 9 Optical contact
a Values for # 22, # 20, # 16, # 12 electrical contacts are
for « contact entering mating insulator » extracted from
ARINC Specification 600 These values are given for
information only Refer to ARINC Specification 600 for
more information
b Values for # 22, # 20, # 16, # 12 electrical contacts are for « contact electrically engaged » extracted from ARINC Specification 600 These values are given for information only Refer to ARINC Specification 600 for more information
Trang 136.5.3 Coupling contact condition
Key
1 ∅D2 - Sleeve cavity inner diameter
2 Sleeve to sleeve-holder cavity stop
3 Optical contact to sleeve-holder stop
Condition: in every case, J >>>> 0
The different shapes and dimensions of the sleeve cavity must be defined to warranty this condition
Figure 6 6.5.4 Contact arrangements
Identification of the contact position shall be permanently marked in contrasting colour on the rear face of the module
Contact arrangements 20F12Q8 for shell size 2 or 3: see Figure 7
Trang 14Receptacle rear face Plug rear face Plug front face
Number of contacts Contact size Insert cavity location
12 Optical contact RR/RR 1 thru 12
8 FR/FR (Receptacle side) 8 (Quadrax)
RR/RR (Plug side) AA thru HH
NOTE RR/RR = Contacts are REAR RELEASE / REAR REMOVABLE
FR/FR = Contacts are FRONT RELEASE / FRONT REMOVABLE
Figure 7
Receptacle front face (without sleeve holder)
Trang 15Contact arrangements 36F36 for shell size 2 or 3: see Figure 8
5 End of the optical contacts
6 Angular position of the optical contact polarization key
Number of contacts Contact size Insert cavity location
36 Optical contact RR/RR 1 thru 36
Receptacle front face (without sleeve holder)
Trang 16Contact arrangements 17F12Q2 for shell size 2 or 3: see Figure 9
6 3 cavities for # 16 electrical contacts
7 2 cavities for # 8 quadrax contacts
Contact body is grounded to the connector shell
8 Angular position of the optical contact polarization key
Number of contacts Contact size Insert cavity location
12 Optical contact RR/RR 1 thru 12
3 FR/FR (Receptacle side) 16 (Electrical)
RR/RR (Plug side) 13 thru 15
2 FR/FR (Receptacle side) 8 (Quadrax) 16 thru 17
NOTE RR/RR = Contacts are REAR RELEASE / REAR REMOVABLE
FR/FR = Contacts are FRONT RELEASE / FRONT REMOVABLE
Figure 9
Receptacle front face (without sleeve holder)
Trang 17Contact arrangements 12F12 for shell size 1: see Figure 10
Key
1 Ref on ribs
2 Keyway
3 12 optical cavities
4 End of the optical contacts
5 Cavity for sleeve-holder screw (on receptacle side)
6 Angular position of the optical contact polarization key
Number of contacts Contact size Insert cavity location
12 Optical contact RR/RR 1 thru 12
NOTE RR/RR = Contacts are REAR RELEASE / REAR REMOVABLE
FR/FR = Contacts are FRONT RELEASE / FRONT REMOVABLE
Figure 10
Receptacle front face (without sleeve holder)
Trang 187 Tests
7.1 Tests according to EN 2591-100 series
The tests of EN 2591-100, applicable in the context of this standard as well as the details necessary for implementing them and for inspecting connector characteristics, are given in Table 1
Table 1
6101 Optical elements - Visual examination
No loosening of parts, cracks, excessive wear, or detached parts Optical face undamaged and free from contamination when examined at 100 × magnification minimum
102 Examination of dimensions and mass
According optical contact Product Standard
NOTE In the case of a Qualified Inspection System, the parts unrelated to a Production Batch, may be used
6301 Optical elements - Endurance at temperature For performance and test method requirements refer to the applicable Product Standard for the component
and cable under test
302 Climatic sequence For performance and test method requirements refer to the applicable Product Standard for the component
and cable under test
6303 Optical elements - Cold/low pressure and damp heat Not applicable
6305 Optical elements - Rapid change of temperature For performance and test method requirements refer to the applicable Product Standard for the
component and cable under test
6314 Optical elements - Immersion at low air pressure Not applicable
6315 Optical elements - Fluid resistance See Table 2 for fluids, number of cycles, temperature and time of immersion, and temperature of third phase
6316 Optical elements - Ozone resistance Not applicable
6318 Optical elements - Fire resistance Not applicable
continued
Trang 19Table 1 (continued)
319 Gastightness of solderless wrapped connections Not applicable
320 Simulated solar radiation at ground level Not applicable
6321 Optical elements - Damp heat, cyclic test Connector mated, 2 cycles Method A
6323 Optical elements - Thermal shock (Hermetically sealed devices) Not applicable
6324 Optical elements - Interfacial sealing Not applicable
6401 Optical elements - Acceleration steady state Not applicable
6403 Optical elements - Vibrations Method B, Figure 2, Table 1, Level E 3 axes (X, Y and Z), 8 hours / axe
6404 Optical elements - Transverse load Not applicable
6406 Optical elements - Mechanical endurance For performance and test method requirements refer to the applicable Product Standard for the component
and cable under test
407 Durability of contact retention system and seals For performance and test method requirements refer to the applicable Product Standard for the component
and cable under test
Arrangement size
Coupling force
N max
Uncoupling force
N min
F12 (12F12) 105 12 F17 (17F12Q2) 140 23,3 F20 (20F12Q8) 225 29,6 F36 (36F36) 300 36
These values are increased by 50 % at – 25 °C and
by 25 % after test EN 2591-308 Inserts fully populated
410 Insert retention in housing (axial) Not applicable
411 Insert retention in housing (torsional) Not applicable
412 Contact insertion and extraction forces
Contact size Axial load (N)