Steel Sheet Piles > U SectionOriental Sheet Piling Rep Office- 62 A 23 Pham Viet Chanh St, W19 Binh Thanh Dist Tel: 8405 207_HP090 927 0033 Since the beginning of the 20th century milli
Trang 1Steel Sheet Piles > U Section
Oriental Sheet Piling Rep Office- 62 A 23 Pham Viet Chanh St, W19
Binh Thanh Dist Tel: 8405 207_HP090 927 0033
Since the beginning of the 20th century millions of tons of U sheet piles have been used all over the world for every kind
of structure
The advantages of U piles are multiple:
-• A wide range of sections forming several series with various geometrical characteristics, offering the choice of the section technically and economically best suited for a specific project
• The combination of great wave depth with important flange thickness giving excellent statical properties
• Easy fixing of tie rods and swivelling attachments, even under water
Section Dimensions Sectional area Mass Moment of section Elastic moment Static section Plastic
mm mm mm mm cm 2 /m kg/m kg/m 2 cm 4 /m cm 3 /m cm 3 /m cm 3 /m
AU
14 750 408 10,0 8,3 132 77,9 104 28710 1410 820 1663
AU 16 750 411 11,5 9,3 147 86,3 115 32850 1600 935 1891
AU 17 750 412 12,0 9,7 151 89,0 119 34270 1665 975 1968
AU 18 750 441 10,5 9,1 150 88,5 118 39300 1780 1028 2082
AU 20 750 444 12,0 10,0 165 96,9 129 44440 2000 1157 2339
AU 21 750 445 12,5 10,3 169 99,7 133 46180 2075 1200 2423
AU 23 750 447 13,0 9,5 173 102,1 136 50700 2270 1285 2600
AU 25 750 450 14,5 10,2 188 110,4 147 56240 2500 1420 2866
AU 26 750 451 15,0 10,5 192 113,2 151 58140 2580 1465 2955
PU 12 600 360 9,8 9,0 140 66,1 110 21600 1200 715 1457
PU
12
10/10 600 360 10,0 10,0 148 69,6 116 22580 1255 755 1535
PU 16 600 380 12,0 9,0 159 74,7 124 30400 1600 925 1878
PU 20 600 430 12,4 10 180 84,3 141 43000 2000
PU 22 600 450 12,1 9,5 183 86,1 144 49460 2200 1275 2580
Trang 2PU 25 600 452 14,2 10,0 199 93,6 156 56490 2500 1435 2899
PU 32 600 452 19,5 10,0 242 114,1 190 72320 3200 1825 3687
L 3 S 500 400 14,1 10,0 201 78,9 158 40010 2000 1175 2389
L 4 S 500 440 15,5 10,0 219 86,2 172 55010 2500 1455 2956
JSP 3 400 250 13,0 - 191 60,0 150 16800 1340 730
-JAPAN / KOREA SHEET PILES
Dimensions and Sectional Properties
Section
Type
Width
(B)
Hei-ght (H)
Avg Coat-ing Area*
Thick-ness (T)
Sec-tional Area (A)
Wei-ght (W)
Moment
of Inertia (Lx)
Setion Mod-ulus
Sec-tional Area
Wei-ght (W)
Moment
of Inertia (Ix)
Section Mod-ulus (Zx)
mm mm m 2/ m mm cm 2 kg/m cm 4 cm 3 cm 2 /m kg/m 2 cm 4 /m cm 3 /m
III 400 125 0.55 13.0 76.42 60.0 2,220 223 191.0 150 16,800 1,340
III A 400 150 0.57 13.1 74.40 58.4 2,790 250 186.0 146 22,800 1,520
IV 400 170 0.63 15.5 96.99 76.1 4,670 362 242.5 190 38,600 2,270
IV A 400 185 0.62 16.1 94.21 74.0 5,300 400 235.1 185 41,600 2,250
III L 500 170 0.69 12.0 87.90 69.0 4,420 352 175.8 138 27,500 1,620
IV L 500 200 0.73 17.0 111.50 87.5 7,080 470 223.0 175 50,000 2,500
VL 500 200 0.71 24.3 133.80 105.0 7,960 520 267.6 210 63,000 3,150
VI L 500 225 0.75 27.6 153.00 120.0 11,400 680 306.0 240 86,000 3,820
Trang 3C III 400 125 13.0 60.0
* Mean value of front and back areas
Section
w H t Sectional area Weight Unit of Inertia Moment of Section Modulus Sectional area Weight Unit of Inertia Moment of Section Modulus
mm mm mm cm 3 kg/m cm 4 cm 3 cm 2 /m kg/m2 cm 4 /m cm 3 /m
*ISP-II
ISP-III
*ISP IV
* These sizes indicated by an asterisk (*) are not included in regular rolling schedules.
Should you need any futher information Pls feel free to call:
(84.8) 8405 207 - HP 090 927 0033