David Schwind Tom Schindler Charles M Salter Associates IncSan Francisco, CA, USA CINEMA SOUND ISOLATION Consultants in Acoustics & Audio/Visual System Design... CINEMA AS A SOUND SOURC
Trang 1David Schwind Tom Schindler Charles M Salter Associates Inc
San Francisco, CA, USA
CINEMA SOUND ISOLATION
Consultants in Acoustics
& Audio/Visual System Design
Trang 2NEW ISSUES FACING DEVELOPERS
NOISIER SITES NEXT TO RAILWAY TRACKS, FREEWAYS, AND AIRPORTS
INCLUSION IN MIXED-USE RESIDENTIAL AND RETAIL BUILDINGS
Trang 3CINEMA AS A NOISE RECEIVER
ON-SITE NOISE (AND VIBRATION)
MEASUREMENTS
RAILWAY
-AIRBORNE NOISE, GROUND VIBRATION
-ISOLATE CINEMAS WITH RUBBER BEARINGS
Trang 4CINEMA AS A SOUND SOURCE
Trang 5THE ROLE OF SOUND ISOLATION
IN THE CINEMA PRESENTATION
-BOTH TOP AND BOTTOM OF RANGECRUCIAL TO THE SUCCESSFUL
IMPLEMENTATION OF MULTI-CINEMA
Trang 6INTRUSIVE SOUND SOURCES
IMPACTING CINEMAS
EXTERIOR/EXTERNAL NOISE
-TRAFFIC, AIRCRAFT, ETC
-ADJACENT TENANTS
PATRONS IN ENTRY LOBBIES,
FOYER SOUND SYSTEMS, ELEVATORS,AND ADJACENT CONCESSION AREASSOUND SYSTEMS IN
ADJACENT CINEMAS
Trang 8SOUND ISOLATION
Trang 9F IB ERGLA SS BA TT IN SULAT IO N
(3 ) LA YERS 15 m m (5 /8 ”)
G YPSUM BOARD
(2 ) LA YERS 15 m m (5 /8 ”) GYPSUM BOARD ON RES ILE IN T
Trang 10DOUBLE FRAME DEMISING WALL
BATT IN SULAT IO N
(1 ) LA YER 19 m m (3 /4") and (2 ) LA YERS 12 5 m m (1/2 ") GYPSUM BOARD ON EA CH OUTS ID E STUD FA CE
146 m m (6 ")
M ETA L STUD , 600 m m (24 ") O C
550 m m
(22 ")
Trang 11BLOCK/FRAME DEMISING WALL
50 m m (2 ") SEPA RAT IO N , M IN IM UM
190 m m (8 ") SO L ID CO RE O R SO L ID GROUTED M A SONRY
Trang 12DEMISING WALLS/THX RECOMMENDATION COMPARISON
-10 0 10 20 30 40 50 60 70 80 90 100
DOUBLE FRAME WALL TRANSMISSION LOSS
SINGLE FRAME WALL TRANSMISSION LOSS
SINGLE STUD
RESILIENT CHANNNEL
DOUBLE FRAME
BLOCK/FRAME
Trang 13BLOCK/DOUBLE RESULTING INTRUSIVE SOUND LEVEL
SINGLE RESULTING INTRUSIVE SOUND LEVEL
Trang 14FRAME-DISCONTINUOUS ROOF SYSTEM
AT DEMISING WALL
Trang 15VERTICAL SOUND
ISOLATION
Trang 16F IN ISH C E IL IN G (N RC -0 60 )
CONCRETE FLOOR DECK
WITH ACOUSTICAL TILE CEILING
Trang 17CONCRETE FLOOR DECK WITH RESILIENTLY SUSPENDED
F IN ISH C E IL IN G (N RC -0 60 )
IN SULA T IO N
15mm (5 /8 ”) PLYW OOD
150 m m (6 ”)
Trang 18100mm (4 ”) RE IN FO RCED
2400 kg/m 3 (150 lb /ft 3 ) CONCRETE
15 m m (5 /8 ”) PLYW OOD
50 m m (2 ”) RES IL IEN T SYSTEM
Trang 19CONCRETE FLOATING FLOOR
WITH STADIUM SEATING
19 m m (3 /4 ”)
NEO PRENE PAD
2400 kg/m 3 (150 lb /ft 3 ) CONCRETE
15 m m (5 /8 ”) PLYW OOD
50 m m (2 ”) RES IL IEN T SYSTEM
STRUCTURA L D ECK (150 m m (6 ”) CONCRETE)
Trang 20CINEMA FLOOR/CEILING PERFORMANCE
-10 0 10 20 30 40 50 60 70 80 90 100
150 mm (6”) THICK SLAB WITH GYPSUM BOARD CEILING- TRANSMISSION LOSS
100 mm (4 “) THICK FLOATING SLAB OVER STRUCTURAL SLAB TRANSMISSION LOSS
CONCRETE FLOOR DECK WITH
ACOUSTICAL TILE CEILING
CONCRETE FLOOR DECK WITH
RESILIENT CEILING
CONCRETE FLOATING FLOOR
Trang 21CINEMA FLOOR/CEILING PERFORMANCE
-10 0 10 20 30 40 50 60 70 80 90 100
CONCRETE FLOOR DECK WITH
ACOUSTICAL TILE CEILING
CONCRETE FLOOR DECK WITH
RESILIENT CEILING
CONCRETE FLOATING FLOOR
RESULTING INTRUSIVE SOUND LEVEL (SLAB W/
Trang 22MEASURE SOUND LEVELS ON NOISY SITESDEFINE THE ACOUSTICAL CRITERIA
SELECT INTER-CINEMA DOUBLE WALLS
DON’T NEGLECT VERTICAL ISOLATION
DON’T LOCATE CINEMAS DIRECTLY
ADJACENT RESIDENCES
Trang 23Charles M Salter Associates Inc
Consultants in Acoustics
& Audio/Visual System Design
CINEMA SOUND ISOLATION