Obligatory references if applying this annex

Một phần của tài liệu Bsi bs en 15378 2007 (2008) (Trang 30 - 38)

EN 15316-2-1, Heating systems in buildings — Method for calculation of system energy requirements and system efficiencies — Part 2-1: Space heating emission systems

EN 15316-2-3, Heating systems in buildings — Method for calculation of system energy requirements and system efficiencies — Part 2-3: Space heating distribution systems

Table A.4 User and heating system, identification information (for use in 6.3)

Heated surface All

Type of building Residential Non residential

Nominal heat generation power < 100 kW > 100 kW < 100 kW > 100 kW Owner / administrator name Required Required Required Required

Address Required Required Required Required

Total floor area or volume Required Required Required Required Heated floor area or volume Required Required Required Required

Age of the building a Required Required Required Required

Height above sea level Required Required Required Required Design outside temperature Required Required Required Required

Building category and use b Required Required Required Required

Building height Required Required Required Required

Type of building thermal insulation c Required Required Required Required Conservation of building insulation d Required Required Required Required Building plans / sketch Optional Required Optional Required

List of heated zones Required Required Required Required Occupancy patterns and timing Required Required Required Required Date of installation of the heating system Required Required Required Required Heating system design Required Required Required Required Commissioning reports Optional Required Optional Required

Energy declaration e Required Required Required Required

Functional diagram Required Required Required Required

Control system identification Required Required Required Required Location of main components Required Required Required Required Attached systems data Required Required Required Required Heating medium quality reports Optional Required Optional Required

a 0 to 20 Years / 20 to 50 Years / more than 50 years.

b House / apartment / office/ etc. as defined in EPBD annex.

c Non insulated / external insulation / internal insulation.

d Original / improved / damaged.

e Depending on installation date.

Table A.5 Space heating emission sub-system, identification information (for use in 6.8)

Heated surface All

Type of building Residential Non residential

Nominal heat generation power < 100 kW > 100 kW < 100 kW > 100 kW

Type of heat emitters a Required Required Required Required

Heat emitter hydraulic connection type b Required Required Required Required Number of heat emitters Optional Required Optional Required

a For each zone.

b Direct / by-pass or two pipes / single pipe.

Table A.6 Space heating emission control sub-system, identification information (for use in 6.9)

Heated surface All

Type of building Residential Non residential

Nominal heat generation power < 100 kW > 100 kW < 100 kW > 100 kW

Type of local control a Required Required Required Required

Type of central control b Required Required Required Required

Setting of outdoor reset function for flow temperature

Required Required Required Required

Time control type c Required Required Required Required

List of controls available to users Required Required Required Required User instruction available Required Required Required Required

a Manual / zone / room.

b None / external temperature compensation.

c None / fixed time schedule / occupancy based.

Table A.7 Space heating distribution sub-system, identification information (for use in 6.10)

Heated surface All

Type of building Residential Non residential

Nominal heat generation power < 100 kW > 100 kW < 100 kW > 100 kW

Network typology a Required Required Required Required

Expansion system type b Required Required Required Required

List of zones Required Required Required Required

Circulation type c Required Required Required Required

Status of piping insulation of space heating

distribution system Required Required Required Required

Circulation pump(s) maximum rated power Required Required Required Required Circulation pump(s) set power Required Required Required Required Circulation pump(s) type d Required Required Required Required Circulation pump(s) working point e Optional Required Optional Required

Unbalancing symptoms f Required Required Required Required

a Zones / vertical columns.

b Open vented / closed.

c Gravity / forced.

d Fixed speed / adjustable speed / constant differential pressure / variable/proportional differential pressure.

e Head and flow rate.

f Example: unequal room temperatures, time delay, different ∆θs on heat emitters.

Table A.8 Generation sub-system, identification information (for use in 6.11.1)

Heated surface All

Type of building Residential Non residential

Nominal heat generation power < 100 kW > 100 kW < 100 kW > 100 kW Number of boilers installed Required Required Required Required Total installed nominal power Required Required Required Required

Fuel(s) Required Required Required Required

Type of generation control Required Required Required Required Hydraulic circuit functional diagram Required Required Required Required

Spare units Required Required Required Required

Other generation sub-systems, type Required Required Required Required

Table A.9 Heating system boiler, identification information (for use in 6.11.2)

Fuel type Gaseous and liquid Solid

Nominal heat generation power < 100 kW > 100 kW < 100 kW > 100 kW

Boiler duty (heat/dhw) Required Required Required Required

Fuel(s) Required Required Required Required

Fuel feed typology a Optional Optional Required Required

Boiler manufacturer Required Required Required Required

Boiler model Required Required Required Required

Boiler serial number Optional Optional Optional Optional

Maximum power rated input b Required Required Required Required Maximum power rated output c Optional Optional Optional Optional Minimum power rated input b Required Required Required Required Minimum power rated output c Optional Optional Optional Optional Boiler manufacture date or year Required Required Required Required

Boiler classification d Optional Optional Optional Optional

Condensing/non condensing Required Required Required Required CE labelling efficiency stars (if available) Required Required Required Required Burner manufacturer and model e Required Required Required Required

Burner power range e Required Required Required Required

Power modulation type f Required Required Required Required

a Automatic or manual.

b Combustion power.

c Net power to heating system.

d Bxx or Cyyy : typology of air flue gas circuit, fan position etc.

e If a separate burner is fit to the boiler.

f Fixed, stepped (multistage), continuous modulation.

Table A.10 Procedures and methodologies required for heating system boiler inspection (for use in 6.11.2)

Fuel type Gaseous and liquid Solid fuel

Nominal heat generation power

(ref. annex) < 100 kW > 100 kW < 100 kW > 100 kW Measurement M.1 Suitable Suitable Suitable Suitable Combustion

power

Maintenance

data M.2 Suitable NO Suitable NO

Measurement C.1 Suitable Suitable Suitable Suitable Boiler basic

settings and combustion efficiency

Maintenance

data C.2 NO NO NO NO

Surface

temperature N.5.1.1 Suitable Suitable Suitable Suitable Losses

through the envelope (radiation losses) a

Tabulated

values N.5.1.2 Suitable Suitable Suitable Suitable

Losses through the chimney with burner off a

Tabulated values

N.5.2 Suitable Suitable Suitable Suitable

Tabulated values

N.5.3.1 Suitable Suitable Suitable Suitable Stand-by

operation N.5.3.2 Suitable Suitable Suitable Suitable Total stand-

by losses test a

Auxiliary heater N.5.3.3 Suitable Suitable Suitable Suitable Database

reference N.1.1 Suitable Suitable Suitable Suitable Default tables N.1.2 Suitable Suitable Suitable Suitable Boiler directive

data N.1.3 Suitable Suitable Suitable Suitable

Boiler cycling method

N.1.4 Suitable Suitable Suitable Suitable Boiler

annual efficiency

Total stand-by

losses N.1.5 Suitable Suitable Suitable Suitable

Settings verification L suitable Suitable Suitable Suitable

a As required by the selected methodology for boiler annual efficiency.

Table A.11 Procedures and methodologies required for generation sub-system sizing (for use in 6.12.1)

Fuel type Gaseous and liquid Solid

Nominal heat generation power

(ref. annex)

< 100 kW > 100 kW < 100 kW > 100 kW Heat load calculation O.1.1 Suitable Suitable Suitable Suitable Existing heat load calculation O.1.2 Suitable Suitable Suitable Suitable

Energy signature O.1.3 Suitable Suitable Suitable Suitable

Fuel consumption O.1.4 Suitable Suitable Suitable Suitable

Heat emitters installed O.1.5 Suitable Suitable Suitable Suitable NOTE Preferred methodology: energy signature.

Table A.12 Procedures and methodologies required for determination of performance of space heating sub-systems (for use in 6.13)

Building type Residential Non residential

Nominal heat generation power

(reference)

< 100 kW > 100 kW < 100 kW > 100 kW Emission Tabulated

calculation method

EN 15316-2-1 Suitable Suitable Suitable Suitable

Emission

control Tabulated calculation method

EN 15316-2-1 Suitable Suitable Suitable Suitable

Distribution Tabulated calculation method

EN 15316-2-3 Suitable Suitable Suitable Suitable

Table A.13 Domestic hot water sub-system, identification information (for use in 6.14)

Type of building Residential Non residential

Nominal heat generation power < 100 kW > 100 kW < 100 kW > 100 kW Type of domestic hot water production a Required Required Required Required Heat source type and duty b Required Required Required Required

Boiler nominal power Required Required Required Required

Heat exchanger capacity Required Required Required Required

Storage volume Required Required Required Required

Type of domestic hot water production control

Required Required Required Required

Type of recirculation c Required Required Required Required

Circulation pump(s) maximum rated power Required Required Required Required Circulation pump(s) set power Required Required Required Required Circulation pump(s) type d Required Required Required Required

Recirculation timing Required Required Required Required

Status of domestic hot water piping

insulation Required Required Required Required

a Instantaneous / storage.

b Specific generator / heating system generator.

c Gravity / forced.

d Fixed speed / adjustable speed / constant differential pressure / variable/proportional differential pressure.

Annex B (informative)

Examples of national inspection class tables

Một phần của tài liệu Bsi bs en 15378 2007 (2008) (Trang 30 - 38)

Tải bản đầy đủ (PDF)

(98 trang)