EN 12828, Heating systems in buildings — Design of water-based heating systems

prEN 15603:20073), Energy performance of buildings — Overall energy use and definition of energy ratings

Annex P (informative)

Examples of national data

Table P.1 Gross boiler seasonal efficiency for single boiler for space heating (source: NL) Boiler type (efficiencies at net values) Gross seasonal boiler efficiency Local gas or oil heater (inclusive pilot flame) 65 %

– no test data 75 %

– full load net efficiency ≥ 88,5 % 80 % – Gaskeur HR 100 label

(part load net efficiency ≥ 101 %) 90 % – Gaskeur HR 104 label

(part load net efficiency ≥ 105 %) 92,5 % Gas fired air heater

(excl. pilot flame)

– Gaskeur HR 107 label

(part load net efficiency ≥ 108 %) 95 % Oil fired boiler for a single dwelling, within the heated space

or

Oil fired boiler for a non residential building with a “user surface” ≤ 500 m2, within the heated space

Efficiency exclusive pilot flame.

75 %

Oil fired boiler for a single dwelling outside the heated space or

Oil fired boiler in a collective heating installation for more dwellings

or

Oil fired boiler for a non residential building with a “user surface” > 500 m2 or with the boiler outside the heated space All efficiencies exclusive pilot flame.

70 %

Table P.1 Gross boiler seasonal efficiency for single boiler for space heating (source: NL) Boiler type (efficiencies at net values) Gross seasonal boiler efficiency Gas fired boiler for a single dwelling, within the heated space

or

Gas fired boiler for a non residential building with a “user surface” ≤ 500 m2, within the heated space

θgen,f,desa ≤ 55 °C θgen,f,desa > 55 °C

– no test data 75 % 75 %

– full load net efficiency ≥ 88,5 % 80 % 80 % All efficiencies excl.

pilot flame

– Gaskeur HR 100 label

(part load net efficiency ≥ 100 %) 92,5 % 90 % – Gaskeur HR 104 label

(part load net efficiency ≥ 104 %) 95 % 92,5 % – Gaskeur HR 107 label

(part load net efficiency ≥ 107 %) 97,5 % 95 % Gas fired boiler for a single dwelling outside the heated space

or

Gas fired boiler in a collective heating installation for more dwellings

or

Gas fired boiler for a non residential building with a “user surface” > 500 m2 or with the boiler outside the heated space

θgen,f,desa ≤ 55 °C θgen,f,desa > 55 °C

– no test data 70 % 70 %

– full load net efficiency ≥ 88,5 % 75 % 75 % All efficiencies excl.

pilot flame

– Gaskeur HR 100 label

(part load net efficiency ≥ 100 %) 87,5 % 85 % – Gaskeur HR 104 label

(part load net efficiency ≥ 104 %) 90 % 87,5 % – Gaskeur HR 107 label

(part load net efficiency ≥ 107 %) 92,5 % 90 %

a θgen,f,des is design boiler flow temperature.

Table P.2 Gross boiler seasonal efficiency for domestic hot water (source: NL)

Boiler type (efficiencies at net values) Gross seasonal

boiler efficiency Individual boilers

Gas fired hot water heater or combi-boiler 30 %

Gas fired hot water heater Gaskeur CW label 40 %

Gas fired combi-boiler Gaskeur CW label 50 %

Gas fired combi-boiler Gaskeur HR / CW label 60 %

Collective systems

Gas fired hot water storage heater (> 70 kW) 50 %

Table P.3 Default seasonal efficiency based on fuel, boiler age and type (source UK)

Fuel, boiler age and type Default seasonal

efficiency Gas, pre-1979, balanced or open-flue, floor mounted 55 % Gas, 1979 to 1997, balanced or open-flue, floor mounted 65 %

Gas, pre-1998, balanced or open-flue, wall mounted 65 %

Gas, pre-1998, fan assisted flue, high thermal capacity 68 % Gas, pre-1998, fan assisted flue, low thermal capacity 72 %

Gas, pre-1998, condensing 85 %

Gas, 1998 onward, non-condensing, with permanent pilot light 69 % Gas, 1998 onward, non-condensing, with automatic ignition 73 % Gas, 1998 onward, condensing, with permanent pilot light 79 % Gas, 1998 onward, condensing, with automatic ignition 83 %

Oil, pre-1985 65 %

Oil, 1985 to1997 70 %

Oil, 1998 onward, non-condensing 79 %

Oil, condensing 83 %

Solid fuel, manual feed, installed in unheated space 55 %

Solid fuel, manual feed, installed in heated space 60 %

Solid fuel, auto feed, installed in unheated space 60 %

Solid fuel, auto feed, installed in heated space 65 %

Bibliography

[1] prCEN/TR 15615, Explanation of the general relationship between various CEN standards and the Energy Performance of Buildings Directive (EPBD) ("Umbrella document")

[2] EN ISO 15927-1, Hygrothermal performance of buildings — Calculation and presentation of climatic data — Part 1: Monthly means of single meteorological elements (ISO 15927-1:2003)

[3] ISO 13600:1997, Technical energy systems — Basic concepts

[4] ISO 13602-2, Technical energy systems — Methods for analysis — Part 2: Weighting and aggregation of energywares

National Annex NA

Inspection class tables for use in the UK

NA.1 General

The inspection class tables given in this Annex for use in the UK should be used instead of the default inspection class tables given in Annex A.

Inspection classes are based on:

• fuel type;

• power (boiler effective rated output)

where “effective rated output” (expressed in kW) is the maximum calorific output specified and guaranteed by the manufacturer as being deliverable during continuous operation while complying with the useful efficiency indicated by the manufacturer.

Table NA.1 — Definition of boiler inspection classes

Fuel type Natural gas and LPG Oil Solid fuel

Power k 100 kW > 100 kW k 100 kW > 100 kW k 100 kW > 100 kW

NA.2 Boiler inspection

Table NA.2 — User, building and boiler identification data required for use in 5.2 (to be used instead of Table A.2)

Fuel type Natural gas and LPG Oil Solid fuel

Power k 100 kW > 100 kW k 100 kW > 100 kW k 100 kW > 100 kW

Date of inspection Required Required Required Required Required Required Customer name Required Required Required Required Required Required Customer address Required Required Required Required Required Required Installation address Required Required Required Required Required Required Responsible person Optional Required Optional Required Optional Required Boiler manufacturer Required Required Required Required Required Required Boiler model name Required Required Required Required Required Required Boiler model qualifier (if any) Required Required Required Required Required Required Boiler serial number Optional Required Optional Required Optional Required Boiler manufacture date or year 1 Required Required Required Required Required Required Boiler fuel Required Required Required Required Required Required Boiler fuel feed type 2 Optional Optional Optional Optional Required Required Boiler is condensing/non-

condensing Optional Required Optional Required Optional Optional

Boiler type (regular/combi) Required Optional Required Optional Optional Optional Boiler duty (heating/domestic

hot water/both) Required Required Required Required Required Required Boiler effective rated output Required Required Required Required Optional Required Boiler minimum rated output Optional Required Optional Required Optional Optional Boiler ignition 3 Optional Optional Optional Optional Optional Optional Boiler seasonal efficiency 4 Required Required Required Required Required Required Boiler, date last serviced Optional Required Optional Required Optional Required System circulation 5 Optional Required Optional Required Optional Required Boiler interlock 6 Required Required Required Required Optional Required Boiler sequence control 7 Required Required Required Required Optional Required Boiler hot water pipes insulated Optional Required Optional Required Optional Required Weather (outside temperature)

compensation Optional Required Optional Required Optional Required

1 If not available, estimate age of boiler.

2 Automatic or manual.

3 Permanent pilot light or not.

4 Warning to be given that estimate of seasonal efficiency relies upon adequate system controls.

5 Fully pumped/semi-gravity/gravity.

6 Interlock means boiler switched off by thermostat(s) when heating and hot water have attained the required temperature.

7 In multiple boiler installations only.

Table NA.3 — Procedures and methodologies required for boiler inspection for use in 5.9 (to be used instead of Table A.3)

Table NA.4 — Default seasonal efficiency for boilers in dwellings based on fuel, boiler age and type, for use in 5.9

Fuel type Any

Power k 70 kW > 70 kW Any

Auxiliary classification property Dwelling 1 Dwelling 2 Not a dwelling 2

Boiler seasonal

efficiency 5 Database

reference Annex N.1.1 Suitable 3 Suitable Suitable Default tables NA.4 or

Annex N.1.2 Suitable 4 Suitable Suitable Boiler directive

data Annex N.1.3 Suitable Suitable Suitable

1 For a boiler k 70kW effective rated output in a dwelling, the preferred order is database reference then default tables then boiler directive data.

2 For a boiler > 70kW effective rated output, or any building that is not a dwelling, the preferred order is database reference then boiler directive data then default tables.

3 The preferred source is the UK Government’s Boiler Efficiency Database www.sedbuk.com

4 If no entry can be found in the Boiler Efficiency Database, Table NA.4 should be used.

5 Warning to be given that estimate of seasonal efficiency relies upon adequate system controls.

Fuel, boiler age and type Default seasonal efficiency

Gas, pre-1979, balanced or open-flue, floor mounted 55 % Gas, 1979-1997, balanced or open-flue, floor mounted 65 % Gas, pre-1998, balanced or open-flue, wall mounted 65 % Gas, pre-1998, fan assisted flue, high thermal capacity 68 % Gas, pre-1998, fan assisted flue, low thermal capacity 72 %

Gas, pre-1998, condensing 85 %

Gas, 1998 onward, non-condensing, with permanent pilot light 69 % Gas, 1998 onward, non-condensing, with automatic ignition 73 % Gas, 1998 onward, condensing, with permanent pilot light 79 % Gas, 1998 onward, condensing, with automatic ignition 83 %

Oil, pre-1985 65 %

Oil, 1985-1997 70 %

Oil, 1998 onward, non-condensing 79 %

Oil, condensing 83 %

Solid fuel, manual feed, installed in unheated space 55 % Solid fuel, manual feed, installed in heated space 60 % Solid fuel, auto feed, installed in unheated space 60 % Solid fuel, auto feed, installed in heated space 65 %

NA.3 Heating system inspection

Inspection classes are based on building type:

• dwelling with a single boiler of effective rated output 100kW;

• all other dwellings and buildings.

where “effective rated output” (expressed in kW) is as defined in NA.1.

Table NA.5 — User and heating system, identification information for use in 6.3 (to be used instead of Table A.4)

Table NA.6 — Space heating emission sub-system, identification information for use in 6.8 (to be used instead of Table A.5)

Building type Dwelling with

single boiler k 100kW Other building

Date of inspection Required Required

Customer name Required Required

Customer address Required Required

Installation address Required Required

Responsible person Optional Required

Building category and use 1 Optional Required

Building characteristics 2 Required Required

Age of the heating system 3 Optional Required

1 As defined in Directive 2002/91/EC (Energy Performance of Buildings Directive) Annex General framework for the calculation of energy performance of buildings section 3.

2 If a heat load calculation is to be carried out as an option in Table NA.12, building characteristics need not be determined here.

Otherwise sufficient information about the building (such as size, age, built form, build quality) should be obtained to allow boiler effective rated output to be compared with likely heat demand. Where boilers are grossly over-sized relative to the heat demand, this should be reported; however, a detailed heat load calculation is not necessary to determine gross over-sizing.

3 Estimated as 0-10 years/10-20 years/>20 years.

Building type Dwelling with

single boiler k 100kW Other building

Type of heat emitters 1 Optional Optional

Heat emitter hydraulic connection

type 2 Optional Optional

Number of heat emitters Optional Optional

1 For each zone.

2 Direct/by-pass or two pipes/single pipes.

Table NA.7 — Space heating emission control sub-system, identification information for use in 6.9 (to be used instead of Table A.6)

Table NA.8 — Space heating distribution sub-system, identification information for use in 6.10 (to be used instead of Table A.7)

Table NA.9 — Generation sub-system, identification information for use in 6.11.1 (to be used instead of Table A.8)

Building type Dwelling with

single boiler k 100kW Other building

Type of local control 1 Required Required

All radiators have TRVs 2 (yes/no) Required Required

Type of central control 3 Required Required

Time control type 4 Required Required

Optimised control (yes/no) Optional Required

Night-time set-back (yes/no) Optional Required

Are controls protected against unauthorised alteration of settings? (yes/no)

Optional Required

List of controls available to users Optional Optional

User instruction available Optional Optional

1 Manual/zone/room.

2 Discount radiators without a TRV in rooms controlled by a room thermostat.

3 None/room thermostat (for whole system)/external temperature compensation.

4 None/fixed time schedule/occupancy based (eg; a programmer).

Building type Dwelling with

single boiler k 100kW Other building

Expansion system type 1 Optional Optional

Multiple zones with independent

controls (yes/no) Optional Required

System circulation 2 Required Required

Number of circulation pumps Optional Optional

Unbalancing symptoms 3 Optional Optional

1 Open vented/sealed.

2 Pumped/gravity.

3 For example, unequal room temperatures, time delay, different %Fs on emitters.

Building type Dwelling with

single boiler k 100kW Other building

Number of boilers installed Optional Required

Total installed nominal power Optional Optional

Boiler fuel(s) Optional Optional

Table NA.10 — Heating system boiler, identification information for use in 6.11.2 (to be used instead of Table A.9)

Building type Dwelling with

single boiler k 100kW Other building

Boiler manufacturer Required Required

Boiler model name Required Required

Boiler model qualifier (if any) Required Required

Boiler serial number Optional Required

Boiler manufacture date or year 1 Required Required

Boiler fuel Required Required

Boiler fuel feed type 2 Optional Optional

Boiler is condensing/non-

condensing Optional Required

Boiler type (regular/combi) Required Optional

Boiler duty (heating/domestic hot

water/both) Required Required

Boiler effective rated output Required Required

Boiler minimum rated output Optional Required

Boiler ignition 3 Optional Optional

Boiler seasonal efficiency 4 Required Required

Boiler, date last serviced Optional Required

Boiler interlock 5 Required Required

Boiler sequence control 6 Required Required

Boiler hot water pipes insulated Optional Required

1 If not available, estimate age of boiler.

2 Automatic or manual.

3 Permanent pilot light or not.

4 Warning to be given that estimate of seasonal efficiency relies upon adequate system controls.

5 Interlock means boiler switched off by thermostat(s) when heating and hot water have attained the required temperature.

6 In multiple boiler installations only.

Table NA.11 — Procedures and methodologies required for heating system boiler inspection for use in 6.11.12 (to be used instead of Table A.10)

Table NA.12 — Procedures and methodologies for generation sub-system sizing for use in 6.12.1 (to be used instead of Table A.11)

Table NA.13 — Procedures and methodologies for determination of performance of space heating sub-systems for use in 6.13 (to be used instead of Table A.12)

Fuel type Any

Power k 70 kW > 70 kW Any

Auxiliary classification property Dwelling 1 Dwelling 2 Not a dwelling 2

Boiler seasonal

efficiency 5 Database

reference Annex N.1.1 Suitable 3 Suitable Suitable Default tables NA.4 or

Annex N.1.2 Suitable 4 Suitable Suitable Boiler directive

data Annex N.1.3 Suitable Suitable Suitable

1 For a boiler k 70 kW effective rated output in a dwelling, the preferred order is database reference then default tables then boiler directive data.

2 For a boiler > 70 kW effective rated output, or any building that is not a dwelling, the preferred order is database reference then boiler directive data then default tables.

3 The preferred source is the UK Government’s Boiler Efficiency Database www.sedbuk.com

4 If no entry can be found in the Boiler Efficiency Database, Table NA.4 should be used.

5 Estimate of seasonal efficiency may be qualified by absence of adequate system controls, identified in Tables NA.7 and NA.14.

Building type Dwelling with

single boiler k 100kW Other building

Heat load calculation 1 O.1.1 Optional Optional

Existing heat load

calculation O.1.2 Optional Optional

Energy signature 2 O.1.3 Optional Optional

Fuel consumption O.1.4 Optional Optional

Emitters installed O.1.5 Optional Optional

1 See note under “Building characteristics” in Table NA.5.

2 Preferred methodology: energy signature.

Building type Dwelling with

single boiler k 100kW Other building

Emission EN 15316-2-1 Optional Optional

Emission control EN 15316-2-1 Optional Optional

Distribution EN 15316-2-3 Optional Optional

NOTE Tabulated calculation method in each case.

Table NA.14 — Domestic hot water sub-system, identification information for use in 6.14 (to be used instead of A.13)

Building type Dwelling with

single boiler k 100kW Other building

Type of domestic hot water

production 1 Required Required

Heat source type and duty 2 Required Required

Boiler effective rated output 3 Required Required

Primary circuit circulation 4 Required Required

Type of domestic hot water

production control 5 Optional Required

Storage volume Optional Optional

Storage vessel thermostat and

boiler interlock 6 Required Required

Storage vessel insulation 7 Required Required

Status of domestic hot water

piping insulation Required Required

1 Instantaneous/storage.

2 Dedicated generator/heating system generator.

3 Not required where the heating system boiler is used.

4 Pumped/gravity.

5 Note if hot water production is subject to time control.

6 For example, a cylinder thermostat connected such that boiler is switched off when hot water (and space heating, if provided from the same boiler) has/have attained the required temperature.

7 State if has factory foam insulation or a jacket with thickness > 75mm.

Một phần của tài liệu Bsi bs en 15378 2007 (2008) (Trang 84 - 98)

Tải bản đầy đủ (PDF)

(98 trang)