HDSL Slimline Repeater The Soneplex HDSL Slimline Repeater operates with ADC's Soneplex HDSL Central Office and Remote modules to extend the effective length of HDSL spans to 24,000 ft u

Trang 1

HDSL Slimline Repeater

The Soneplex HDSL Slimline Repeater operates with ADC's Soneplex HDSL Central Office and Remote modules to extend the effective length of HDSL spans to 24,000 ft using one repeater

or 36,000 ft with two repeaters It inserts into a single slot of any industry-standard 239-mechanics outdoor enclosure, or ADC’s Soneplex Radiator™ or EnCaser™ 819

ADC's Soneplex system is the lowest total cost solution for carriers to grow their T1 business services Focused on providing flexible end-to-end solutions, the Soneplex system saves carriers money on T1-based services over copper or fiber using HDSL, HDSL2, traditional T1 repeater or optical DS2 technology in a single platform From operations, maintenance, provisioning and high-speed backbone connections to central office space and cabling, the Soneplex system is designed to take costs out of today's T1 delivery approach, adding profit

to your bottom line

Features:

• Occupies a single slot in any industry-standard 239-mechanics outdoor enclosure

• Fully complies with Bellcore’s GR-1089 A3 voltage specification for safe span powering

• Provides full sectionalization capability in the Soneplex platform

• Supports advanced HDSL performance monitoring, and enhanced customer and network loopbacks

• Extends HDSL’s effective reach to 24,000 feet with one repeater or 36,000 feet with two repeaters

Trang 2

ADC Telecommunications, Inc., P.O Box 1101, Minneapolis, Minnesota USA 55440-1101

Specifications published here are current as of the date of publication of this document Because we are continuously improving our

products, ADC reserves the right to change specifications without prior notice At any time, you may verify product specifications by

contacting our headquarters office in Minneapolis ADC Telecommunications, Inc views its patent portfolio as an important corporate

asset and vigorously enforces its patents Products or features contained herein may be covered by one or more U.S or foreign patents.

100457 03/02 Original ©2002 ADC Telecommunications, Inc All Rights Reserved An Equal Opportunity Employer

Web Site: www.adc.com

From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-946-3292 For a complete listing of ADC's global sales office locations, please refer to our web site.

Description

A single HDSL Slimline Repeater in the local loop regenerates the HDSL signal, extending the 12,000 ft distance over which a full-duplex DS1 signal can be carried to 24,000 ft Two HDSL Slimline Repeaters may

be used to carry the signal up to 36,000 feet ADC’s ±130 VDC powering design provides maximum span power while complying fully with Bellcore GR-1089 A3 voltage safety standards The HDSL Slimline Repeater is fully compatible with the Soneplex system’s extensive management capabilities, including performance monitoring, sectionalization and enhanced customer and network loopbacks Up to 24 HDSL Slimline Repeaters may be deployed in ADC’s EnCaser 819 outside plant apparatus case Up to 16 HDSL Slimline Repeaters may be deployed in ADC’s Soneplex Radiator case

2B1Q HDSL DSX-1

RLX

3

12,000 FT (35 dB)

CENTRAL OFFICE

CENTRAL OFFICE

DS1

SONEPLEX HDSL

CORE

NETWORK

SONEPLEX HDSL SLIMLINE REPEATER

2B1Q HDSL

12,000 FT (35 dB)

2B1Q HDSL

12,000 FT (35 dB)

SONEPLEX HDSL SLIMLINE REPEATER

SONEPLEX HDSL

Specifications

Dimensions (HxWxD): 2.63 x 0.75 x 6.67 inches (6.68 x 1.9 x 16.94 cm)

Weight: 0.8 lbs (0.36 kg)

Operating Temperature: -40°F to 149°F (-40°C to 65°C) ambient temperature inside repeater case

Line Power: ±130 VDC Nominal

Power Consumption: 5.5 Watts maximum per repeater

HDSL Interface

Output Signal Level: 13.5 ±0.5 dBm

Impedance: 135 Ω

Loop Loss Allowed: Up to 35 dB, CO to repeater; first repeater to second repeater, or repeater

to customer premises

System Compatibility: 239-mechanics or ADC Soneplex Radiator and EnCaser repeater cases

Status Indicators: Front panel status and maintenance LEDs