micro-DLC System ADC's PG-Flex micro-DLC provides feeder F1, distribution F2 or drop "pair relief" in areas of the network suffering from copper pair shortages.. It enables Local Exchang
Trang 1micro-DLC System
ADC's PG-Flex micro-DLC provides feeder
(F1), distribution (F2) or drop "pair relief" in
areas of the network suffering from copper
pair shortages It enables Local Exchange
Carriers (LECs) to quickly and
cost-effective-ly meet held order demands for POTS or
ISDN services in these areas PG-Flex is a far
superior alternative to expensive and time
consuming alternatives of cable
rearrange-ments, laying more cable or installing a large
capacity Digital Loop Carrier (DLC) system
The PG-Flex micro-DLC is a highly versatile
platform supporting both indoor and
out-door pair relief applications Remote
termi-nals (RTs), which are deployed in 24-channel
increments, are available in 24, 48 and
96-channel configurations Outside plant
hard-ened enclosures include 24/48-channel
ver-sions with complete lightning protection for
installation at crossboxes or existing
DLC/SLC cabinets Indoor RTs, available in 24/48/96-channel versions, provide a cost-effective alternative to standard D4 channel banks All PG-Flex remotes are line-powered reducing the need for costly batteries and UPS systems
Features:
• Line powered and environmentally hardened remote terminals
• Requires no local power or battery supplies
• Traditional HDSL transmission architecture
• 24-channel system architecture
• Extended temperature rating
• Supports POTS and ISDN services
• Supports MLT testing (TR-909)
• Indoor and outdoor specific remotes
• TR-57 (VF) switch interface
• Supports crisis/temporary service needs
Trang 21/02 • 100040PR
Application
Figure 1 Basic PG-Flex Configuration
CO
Residential or Business Customers Crossbox
PG-Flex RT
Up to 24 Lines PG-Flex COT
HDSL
Figure 2 Feeder Relief at the Crossbox
CO
Business
Strip Mall
HDSL HDSL
PG-Flex COT
PG-Flex RT
PG-Flex RT
Figure 3 Relief to end-customer location
Trang 31/02 • 100040PR
Description
General Specifications
COT and RT equipment are designed to operate over an extended temperature range RTs meet the environmental conditions found in the outside plant The following specifications apply to all PG-Flex hardware:
Temperature: -40º to +65º C (-40º to +150º F)
Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 ft (-60 to 4,000 m)
COT Equipment Specifications
COT Shelves Dimensions (HxWxD): FCS-718: 8.75 x 19.0 x 11.75 in (22.2 x 48.3 x 29.9 cm)
FCS-719: 8.75 x 23.0 x 11.75 in (22.2 x 58.4 x 29.9 cm) Weight: FCS-718: 15.5 lbs (7.0 kg) FCS-719: 20.2 lbs (9.2 kg)
Mounting: EIA hole spacing on universal mounting flanges Finish: zinc plated and aluminum irridited
Terminations: Subscriber Lines: 25-pair Amphenol or wire wrap
HDSL Lines: wire wrap Alarm Relays: wire wrap
CO Battery: screw terminal Metallic Bypass: wire wrap PGTC Interface: 25-pair Amphenol System Power Input Voltage: Fused -42 to -56 VDC
Requirements Input Power: 145 watts (maximum)
Line Output Voltage: ±130 VDC (maximum) Line Output Power: 100 watts (maximum) POTS Channel Interface Analog Impedance: 900 W
(FLC-703 L4) DC Off-Hook Resistance: 960 W
Ringer Equivalence: 0.9 REN at 20 Hz Ring Detection at COT: 65 to 104 Vrms @20 to 60 Hz, superimposed on a DC component of -36 to -56 VDC
ISDN Channel Interface “U” Interface: per ANSI T1.601-1992
RT Equipment Specifications
Ring Output Voltage (At Station): >40 Vrms AC at full load
Generator Output Voltage DC Pedestal: -75 VDC to -40 VDC
Frequency: 20, 25, 30 Hz (±1 Hz) (programmable at system setup and fixed for the entire system) Crest Factor: 1.2 to 1.6
Output Load: 15 REN maximum per system
RT Power Input Voltage: ±130 VDC to ±70 VDC
Supply Input Power: <40 watts
POTS Analog Impedance: 600 W
DC Loop Current: >23 mA into off-hook DC resistance Ringer Output Drive: 5 REN maximum per port
RT DC Supervisory Range: 960 W (Max cable loop resistance, minus 430 W for handset, is 530 W)
RT Idle State Loop Voltage (On-Hook): >40 VDC (Note: ring is negative with respect to Tip)
RT Loop Closure Detection (Off-Hook): RT recognizes resistance between tip and ring £960 W as loop closure
RT On-Hook Detection: The RT recognizes a resistance ³10 kW as an on-hook condition ISDN “U” Interface: per ANSI T1.601-1992
Wire Gauge
26 AWG
PG-Flex Distance Table
24-Channel HDSL
9.0 kft
Subscriber Drop
6.3 kft
Trang 4RT Equipment Catalog Number Description
FRE-765 FRE-860 FRE-865 FRE-867 FRE-868 FRE-869
Remote Terminals L4A L1 L1 L1B L1 L1B L1 L2 L3 L4 L1 L2
Gel-filled IDC •
AMP Quiet Front •
Protection Included in IDC •
Auxiliary Power AMP Quiet Front •
Dimensions Height (in/cm) 19.25/48.9 23.6/59.9 23.6/59.9 23.6/59.9 23.6/60.2 23.6/60.2 22.7/57.8 22.7/57.6 22.7/57.8 22.7/57.6 22.7/57.7 22.7/57.7
Width (in/cm) 14.25/36.2 8.7/22.1 8.7/22.1 8.7/22.1 17.25/43.7 17.25/43.7 11.3/28.6 6.0/15.2 11.3/28.6 6.0/15.2 23.0/58.4 23.0/58.4 Depth (in/cm) 5.93/15.0 6.8/17.3 6.8/17.2 6.8/17.2 6.8/17.2 6.8/17.2 7.25/18.4 7.25/18.4 7.27/18.4 7.25/18.4 7.25/18.4 7.25/18.4
Kilograms 11.9 13.6 15.4 15.4 25.4 25.4 11.3 6.8 11.3 6.8 20.9 20.9
R T C o n f i g u r a t i o n s
COT Equipment Catalog Number Description
O r d e r i n g I n f o r m a t i o n
The table below identifies the different features and capabilities of the PG-Flex Remote Terminals