The E1 QFLC system consists of a rack mounted central exchange shelf and a wall or rack mounted customer premises shelf.. In contrast to fibre optic terminal systems FOTS, which require

Trang 1

The Soneplex System from ADC The T1/E1 Service Delivery Experts

Trang 2

ADC has designed a family of Fibre Loop Converters (FLCs) that provide a cost-effective alternative to deploying service over copper while avoiding the high capital investment

of primary multiplexers and Fibre optic terminals This family includes products designed for economical distribution of single or multiple 2.048 Mb signals

The E1 Quad FLC multiplexes up to four 2.048 Mb signals for transport over two fibres

at typical distances of 72 Km (44 miles) The E1 QFLC system consists of a rack mounted central exchange shelf and a wall or rack mounted customer premises shelf

In contrast to fibre optic terminal systems (FOTS), which require a variety of modules to start up operation, the E1 QFLC module is a stand-alone system and does not require additional plug-in equipment

The E1 QFLC was designed to be installed quickly Installation is accomplished by simply plugging a single module into the chassis and conducting basic checks Exten-sive, built-in self-test circuitry allows the E1 QFLC to isolate module failures and alert maintenance personnel via standard office alarms

The E1 QFLC supports 1+1 redundancy to protect against single point failures of both optical facilities or electronic equipment The E1 QFLC features two sets of bit-error rate (BER) threshold select switches These switches enable the technicians to select the BER at which the module will: 1) declare a minor alarm to indicate that the BER has exceeded an early warning level and 2) initiate protection switching in a system config-ured in a protect mode The BER threshold at which protection switching occurs may be set according to the performance levels developed for access systems

Utilizing remote loopback, end-to-end performance can be tested at the local end By pressing the remote alarm display switch, local front panel LEDs instantly display remote module status This is used to determine the cause of a remote alarm, and provide detail necessary to determine whether or not to dispatch a technician to the far end

Description

Features and Benefits

• Universal chassis concept supports optical hubs and is compatible with ADC’s entire FLC family of O/E products

Mechanical housing can accommodate a wide variety of plug-in modules

The universal chassis provides a broad platform from which new services can be delivered

• Single module system

No need to inventory different working and protect modules, or different near and far-end modules One part number does it all, reducing investment in spare inventory and simplifying circuit provision-ing and installation.

• Optional 1+1 redundancy

Protection against Fibre facility or equipment failures Unprotected circuits can be upgraded later to provide protection, thereby lowering the initial cost of installation.

• Dual selectable BER threshold setting

Provides selectable BER thresholds for protection switching and early warning minor alarm Switching and minor alarm levels can be set according to service requirements.

Features and

Benefits

Trang 3

• Remote (far-end) alarms can be displayed locally

Simplifies trouble diagnostics and allows single-ended trouble shooting This reduces field dispatches and improves responsiveness to potential service interruption.

• Remote housekeeping alarm transport

Housekeeping alarm inputs provide monitoring of external equipment at the remote site, such as fire and door alarms Reduces investment in external alarm reporting systems.

• Individual E1 remote loopback capability

Allows single-ended testing of each E1 link to aid in trouble sectionalization.

• Automatic configuration matching

Simplifies installation by allowing a technician to provision only one module in a link The remaining local, remote and protection modules automatically provision themselves correctly.

• Optional wall mount battery back-up

Provides a minimum of eight hours back-up in the event of commercial power failure, ensuring uninterrupted service Available in 110 VAC or 220/240 VAC versions.

• Voice service channel

- One full duplex connection per QFLC module

- Eliminate separate voice facility during installation

• Laser cutoff safety

- Automatically shuts off laser upon cable disconnect

- Eliminates hazardous conditions

• High power laser transmitter

- Optical power budget at 3 0-33 dB

• Temperature hardened design

- Operating temperature range -40 ° C to 65 ° C

- Humidity range 5% to 95%, non-condensing

• Backward compatible with E1Q-B2LDFC E1 QLFC module

• Extended DC input voltage operating range -40 VDC to -72 VDC

• SNMP access through SNMP map system

- Central control for up to 192 E1 service delivery points

Features and

Benefits

Trang 4

Providing fibre-based E1 services in urban applications requires low first cost installa-tion and the capability to serve multiple customer locainstalla-tions By placing the universal rack mount shelf in the central exchange, up to eight different customer locations may

be served from a single platform Service turn-up is fast, as only one plug-in part number is needed, whether the service is 1:1 protected or unprotected

KEY

–––––––––––––––––––––––––

DDF: Digital Distribution Frame FDP: Fibre Distribution Panel NID: Network Interface Device QFLC: E1 Quad Fibre Loop Converter

Point to Multipoint

By installing the universal chassis at a central location, service providers can support multiple customers in a variety of applications Since the universal chassis supports all FLC modules, modules can be mixed or matched depending on service requirements Described on the following pages are several applications which take advantage of the flexibility in the Fibre Loop Converter system

For more information on ADC products supporting service delivery in the local loop, contact your nearest ADC sales office, listed on the back cover

ADC product offering includes:

• Fibre cable management products

• Copper access and cross-connect products

• Premises multiplexers and circuit termination units

• Outside plant enclosures

Point to Multipoint

Building High Rise

Hut

REH Remote Pedestal

REH Remote Pedestal

Central Exchange Hut Business Park

Office Building

Office Building Office Building

QFLC NI D

N I D QFLC

E1 Electrical

Central Exchange

Office Building

FDP

QFLC N I D

QFLC NI D

Point to

Multipoint

Central Exchange

Trang 5

Remote Pedestals As fibre deployment extends into the loop, remote pedestals and cabinets are being fed

with fibre optic cable from a hut or central exhange The QFLC is ideal for this applica-tion, providing up to 8 E1s in a 4" chassis

KEY

–––––––––––––––––––––––––

DDF: Digital Distribution Frame FDP: Fibre Distribution Panel FOT: Fibre Optic Terminal QFLC: E1 Quad Fibre Loop Converter AS: Access Server

To Central Exchange

Remote Pedestal

E1 Electrical

QFLC

1 - 240 Homes

••

FOT

QFLC

AS

Remote Pedestal

QFLC

AS

Hut

REH Remote

Pedestal

REH

Remote

Pedestal

Central

Exchange

Suburban

Business Parks

With the installation of an eight position rack mount shelf in a central exchange or controlled environmental vault (CEV), a service provider can support multiple custom-ers, each of which would have a wall or rack mount chassis on their premises The E1 Quad Fibre Loop Converter allows the service provider to take advantage of any unused Fibre already terminated at the building premises, thereby providing E1 service in the most economical means possible As the customer’s service requirements become more critical, the service provider can install an additional E1 QFLC on each end of the link to fully protect the system

KEY

–––––––––––––––––––––––––

DDF: Digital Distribution Frame FDP: Fibre Distribution Panel FOT: Fibre Optic Terminal QFLC: E1 Quad Fibre Loop Converter

Central

Exchange

Hut

Business Park

To Central Exchange

Hut

E1 Electrical

QFLC

FOT

Trang 6

High Rise

Customer Premises

E1 Distribution

The Fibre Loop Converter family makes all-fibre building risers an economical reality Referenc-ing the application drawReferenc-ing, you can see many possible configurations that allow for fibre drops on each floor A primary or higher level multiplexer can be located in the base-ment of a high rise building and the E1s can

be deployed to the various floors of the build-ing via E1 QFLC modules

A series of wall mount chassis can be mounted in the wiring closets of each floor

In all situations, an AC power receptacle is all that is required to power the units;

battery back-up is also available

KEY

–––––––––––––––––––––––––

DDF: Digital Distribution Frame FOT: Fibre Optic Terminal MUX: Primary Multiplexer QFLC: E1 Quad Fibre Loop Converter

Central

Exchange

Building High Rise

Ordering

Information

Description Eight Position Universal Rack Mount Chassis

19" or 23" (48.26 or 58.42 cm), -48 VDC, wire-wrap connector

Rear access

Two Position QFLC Chassis

Wire-wrap connector, front access 23" (58.42 cm) rack mounting FRM-FAW02B 23" (58.42 cm) rack mounting (BNC) FRM-FAW02D

Four Position Universal Wall Mount Chassis RJ48 terminations

Wire-wrap terminations

110 VAC redundant power supplies

110 VAC with battery back-up -48 VDC

Catalog Number

FRM-RAW08B

FWM-WWA04A FWM-WWD04B FWM-WWX04A

* See Accessories section for 220 VAC battery backup option.

Building High Rise

To Central

M U X QFLC

M U X QFLC

E1 Electrical

To Central

M U X QFLC

M U X QFLC

E1 Electrical

Trang 7

Description Catalog Number

Ordering

E1 Quad Fibre Loop Converter Micro Processor Unit (MPU)

One per eight position universal chassis; mounts in MPU card slot

Accessories Optional Equipment for Wall Mount Chassis

Swing out bracket for universal wall mount chassis Mounting bracket to rack mount the four position wall mount chassis or battery back-up system

110 VAC battery back-up system for use with FWM-WWX04A 220/240 VAC battery back-up system for use with FWM-WWX04A

Optional Equipment for Two Position Chassis

Used to vertically mount two position chassis Bracket to mount two position QFLC chassis vertically in a cabinet FLC-HDW007

or on a wall

E1Q-B2LDFC FLC-A10MPU

FLC-HDW005 FLC-HDW006 FLC-AC/48V FLC-AC/BB2

Input Frequency:

Input Level:

Output Frequency:

Interface Standard:

Output Signal:

Input/Output Impedance:

OPTICAL Fibre Cable:

Operating Wavelength:

Optical Connector:

Transmit Device:

Receive Device:

2.048 Mbps ± 200 bps; up to four E1 lines; shaped line loss relative to nominal DDF level

0 to -6.0 dB; up to four E1 lines; HDB3 format 2.048 Mbps ± 200 bps

Bipolar Within CCITT G.703 template and level standards

120 Ω nominal at 1024 kHz

9/125 µ m singlemode nominal

1305 nm ± 35 nm FC

Laser PIN Photodiode

Specifications continue on next page

Trang 8

Specifications published here are current as of the date of publication of this document Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice At any time, you may verify product specifications by contacting our

ADC Telecommunications, Inc.

P.O Box 1101

Minneapolis, Minnesota 55440-1101

FAX: (612) 946-3292

From North America, Call Toll Free: 1-800-366-3891, Ext 3223

Outside of North America: 612-938-8080

Home Page Address: http://www.adc.com

International Sales Offices: Belgium 32-2-712-6500 • United Kingdom 44-734-441955

• Montreal, Quebec (514) 677-9166 • Vancouver, BC (604) 270-1675 • Toronto, Ont.

(905) 629-3104 • Ottawa, Ont (613) 723-2171 • Singapore 65-225-8228 •Venezuela

58-2-286-1444 • Mexico City, Mexico 525-658-4519 • Buenos Aires, Argentina (541)

449-2669 • Sao Paulo, Brasil 55-11-3040-0666 • Sydney, Australia 61-2-9975-1499 •

Melbourne, Australia 61-3-9585-3931 • Beijing, China 86-10-6500-7001 • Dusseldorf,

Germany 49-211-530-6550 • Seoul, Korea 82-2-333-8989

OUTPUT POWER Low Power Setting:

High Power Setting:

Receiver Dynamic Range:

Minimum Optical Budget:

Low Power Setting:

High Power Setting:

BER Threshold For Protection Switching:

For Minor Alarm:

POWER Supply Voltage:

Supply Current:

PHYSICAL Dimensions (HxWxD):

Weight:

ENVIRONMENTAL Temperature Operating:

Storage:

Humidity Operating:

Storage:

-5 to -8 dBm; -6.2 dBm typical -3 to -6 dBm, -4.6 dBm typical -4 to -39 dBm

30 dB; 32.8 dB typical

33 dB; 34.4 dB typical 8.5 x 10 -4 to 1 x 10 -10 user selectable threshold

1 x 10 -6 to 1 x 10 -10 user selectable threshold

-40 VDC to -72 VDC

275 mA typical @ -48V/300 mA maximum @ -48V

27.2 x 3.8 x 25.4 cm (10.7" x 1.5" x 10.0") 64 kg (1 lb 6.5 oz.)

-40 ° C to 65 ° C (-40 ° F to 149 ° F) -55 ° C to 80 ° C (-67 ° F to 176 ° F) 5% to 95%, non-condensing 5% to 95%, non-condensing

Specifications

Ngày đăng: 17/01/2014, 08:20