Fiber Connectivity In the backbone or to the desk,optical networks achieve peakperformance with ADC’s high density frames, fiber connectors, patch cords, raceways, and panels featuri
Trang 11st Edition
Trang 2w w w a d c c o m • + 1 - 9 5 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Introduction 3
Featured Products Category 6 4–Pair Outdoor Cable 4
Limited Combustible Category 6 Cable 7
Copper Connectivity Solutions 11
CopperTen Category 6A Solutions 11
Category 6 Solutions 16
Fiber Connectivity Solutions 20
TFP Series Fiber Panels 20
RMG Series Fiber Panels 22
Accessories 23
Broadcast Connectivity Security Solutions 27
ICON® I-W Modular Wall Mount System 27
Wall Mount Bulkhead Panels 28
Connector Products 32
ADC Precision Connector Products 34
Connector Ordering Information 36
Cabling Solutions
Trang 3world's first complete system
to meet the IEEE requirements for 10G Ethernet over 100 meters of the UTP cable.
Fiber Connectivity
In the backbone or to the
desk,optical networks achieve peakperformance
with ADC’s high density frames, fiber connectors,
patch cords, raceways, and
panels featuring integrated
cable management and bend radius protection.
Category 6 & 5e Ethernet
ADC's TrueNet Category
6 & 5e patch panels, patch cords, and cable are
impedance matched to deliver extra bandwidth
and better attenuation with zero bit errors.
Copper Cables
ADC’s high-performance riser
and plenum cable supports
backbone and horizontal
applications TrueNet copper
cables feature patented
enhance signal speed and
strength while minimizing
cable size and crosstalk.
Outdoor Cabling
ADC's outback cable is designed for outdoor use making it ideal for providing IP video to outdoor security cameras.
Internal Security
IP Cameras Card Readers Security Monitors Electronic Locks
Coax Video Solutions
ADC’s BNC video panels and connectos are recognized
as the industry leader in video performance.
Fiber Cables
Fiber cables including: cost saving interlocked armored versions, plenum rated dry loose tube small diameter Indoor/outdoor cables, single mode reduced water peak, and standard or laser optimized multimode configurations.
ADC’s TrueNet® IP Security Cabling System is the integrated portfolio of high-performance copper and fiber cable, connectivity, and cable management products from ADC The precisely tuned TrueNet system exceeds TIA/EIA standards and provides a clear path for uninterrupted IP data and video throughput within the entire network.
True End-to-End Solutions
The TrueNet system delivers proven cable, connectivity, and cable management solutions for fiber,
10 Gigabit Ethernet over UTP, and Category 6/5e from the data center to remote IP security devices.
Trang 4The Outback cable is a 4-pair, 23 gauge Category
6 data cable designed for outdoor use The cable
combines excellent transmission performance and
weather resistant properties It is intended for
outdoor installation, in buried conduit or as aerial
cable making it ideal for outside security IP video
applications The core contains a water blocking
tape which isolates the core from moisture.
Features
Patented AirES® conductor insulation technology enables improved signal strength and speed with superior electrical performanceManufactured with lead free materials Moisture barrier core wrap protects pairs
Common Applications:
4/16 Mb/s Token Ring (IEEE 802.5)100VG-Any LAN (IEEE 802.12)10BASE-T (IEEE 802.3)52/155 Mb/s ATM (ATM Forum)
100 Mb/s TP-PMD
622 Mb/s ATM (ATM Forum)Broadband & Baseband Video1000BASE-T (Gigabit Ethernet)100BASE-T (“Fast Ethernet”)
1 Gigabit Networking System (WGNA)100BASE-T4 (“Fast Ethernet”)1.2 Gb/s ATM (ATM Forum)100BASE-TX (“Fast Ethernet”)
77 Channel Broadband Video
Category 6 4–Pair Outdoor Security Cable
Trang 5Horizontal Cable Requirements
Reel – 1000 ft 42.5 kg/km (29 lbs./kft) TN6TOSP-BK02
O r d e r i n g I n f o r m a t i o n
Trang 6Category 6 4–Pair Outdoor Cable
FREQ MHZ
FITTED IMPEDANCE Ohms
INSERTION LOSS dB/100 m
RETURN LOSS dB/100 m
PAIR-PAIR NEXT dB/100 m
PSNEXT dB/100 m
Spec Max Spec Min Spec Min Spec Min Spec
PSACR dB/100 m
PAIR-PAIR ELFEXT dB/100 m
PSELFEXT dB/100 m
LCL dB/100 m
Min Spec Min Spec Min Spec Min Spec Min
Trang 7ADC’s TrueNet Category 6 Limited Combustible
Cable addresses some of the combustibility and
toxicity safety concerns that network installers
and users have raised regarding the proliferation
of traditional plenum cable Combustibility and
toxicity have long been an industry issue, and
as more and more cable proliferates, especially
in plenum or air-carrying environments, safety
concerns continue to trouble network installers
and users The long standing requirements
and de facto standard of NFPA 262 outline the
combustibility requirements allowable in plenum
spaces However, today many feel that this is
not enough In an effort to reduce this danger
to personnel and equipment further, many users
desire to specify limited combustible cabling
(CMP-50) beyond the basic plenum requirements
Through the use of AirES technology, ADC is
able to deliver its TrueNet Limited Combustible
cable that not only exceeds the CMP-50
standards, but also performs well beyond
Category 6 requirements.
ADC’s AirES technology is a unique patent
design that incorporates channels of air within
the insulation that run the length of the cable
and reduce the amount of material required to
insulate the conductor Since AirES cables require
less insulation material within the cable itself
(32% less) there is less material to burn Less fuel
means less smoke and less toxicity in air-return
environments In addition AirES improves virtually
every attribute associated with the structured
cabling system—signal strength and integrity,
easier installation, increased signal speed,
improved wire management, reduced crosstalk,
even reduced space requirements.
Applications
4/16Mbps Token Ring (IEEE 802.5) 10Base-T (IEEE 802.5)
100Mbps TP-PMD Broadband and baseband video 100Base-T (Fast Ethernet) 100Base-T4 (Fast Ethernet) 100Base-TX (Fast Ethernet) 100VG-AnyLAN (IEEE802.12) 52/155 Mbps ATM (ATM Forum) 622Mbps ATM (ATM Forum) 1000Base-T (Gigabit Ethernet) 1Gbps Networking System (WGNA) 1.2Gbps ATM (ATM Forum)
77 Channel broadband video
Compliances
UL Subject 444 (UL)-C(UL) Type CMP ICEA S-90-661 NEC 800 Type CMP ISO/IEC 11801 Class E ETL verified TIA/EIA-568-B.21-1 Category 6 horizontal cable requirements
Trang 8Limited Combustible Category 6 Cable
Trang 9Insertion Loss dB/100 m
Return Loss dB/100 m
Pair-Pair NEXT dB/100 m
PSNEXT dB/100 m
PSACR dB/100 m
Pair-Pair ELFEXT dB/100 m
PSELFEXT dB/100 m
LCL dB/100 m
Trang 10Limited Combustible Category 6 Cable
4-pair cable, clear jacket: Nominal OD: 0.205 inches (5.2 mm) Maximum Average OD: 0.205 inches (5.2 mm)
Reel packaging – 1000 ft spool 31 TN6ESD-CL02
4-pair cable, Blue jacket: Nominal OD: 0.205 inches (5.2 mm) Maximum Average OD: 0.205 inches (5.2 mm)
Reel packaging – 1000 ft spool 31 TN6ESD-BL02
O r d e r i n g I n f o r m a t i o n
Trang 11An integral part of ADC’s TrueNet Structured Cabling System, CopperTen® is the world’s first
Augmented Category 6 Structured Cabling System to enable 10 Gigabit Ethenet over a full 100 meters
of UTP cable Installed in high performance networks worldwide, the system’s patent-pending design minimizes alien crosstalk and insertion loss and meets the performance requirements of IEEE 802.3an and TIA 568-B.2-10 draft standards.
Data Cables
Patch Panels
Data Cables
XX = Jacket Color: BL = Blue, WT = White, GY = Gray, GN = Green, YL = Yellow, RD = Red
YY = Length: 02 = 1000 ft, 04 = 2000 ft, 05 = 2500 ft
1 RU 24-port Patch Panels
Rear wire manager included
•
•
•
•
Trang 12Copper Connectivity Solutions
TrueNet® CopperTen® Category 6A Structured Cabling Systems Modular Jacks
Patch Cords
Modular Jacks
XX = Jack Color: 01 = White, 02 = Ivory, 03 = Gray, 04 = Black, 05 = Red, 06 = Blue, 07 = Green, 08 = Yellow,
09 = Violet, 10 = Orange
RJ45-RJ45 UTP patch cord
X = Color: 0 = White, 1 = Red, 2 = Blue, 3 = Yellow, 4 = Green, 6 = Gray
Snagless plug design with built-in strain relief
UL 1863 safety ratingMeets performance requirements of TIA/EIA 568-B.2-10 draft standards
•
•
•
•
Trang 13Faceplate Mounting Options
Termination Block
4-pair to 4-pair blue patch cord 6451 2 401-XX
XX = Length: 10 = 4 ft, 20 = 7 ft, 30 = 10 ft, 40 = 15 ft
O r d e r i n g I n f o r m a t i o n
Faceplate Mounting Options
XX = Color: WT = White, IV = Ivory, GY = Gray, BK = Black
Designed to support 10 Gigabit performance by countering negative effects of alien crosstalk
•
•
•
•
Trang 14CopperTen Augmented Category 6 8-Pair Block
Copper Connectivity Solutions
TrueNet® CopperTen® Category 6A Structured Cabling Systems
Design for use with ADC TrueNet Universal Mounting System (UMS) and Type 105 Rod-Mount Bracket
20 year TrueNet CopperTen warranty
O r d e r i n g I n f o r m a t i o n
BX (Box=10 each)
A key component of the TrueNet channel solution, ADC’s highest performing termination block, offers versatility not possible with patch panels The CopperTen 8-pair block’s unique center port eliminates the need to remove cables for testing and because patch cords are “temporary”, the system saves thousands over traditional patched solutions Installations are hardwired providing the cleanest, most secure, reliable and high performing Category 6a system available.
Trang 15High-density design with 24 ports in a single rack unit
Unique polymer design helps eliminate alien crosstalk
Rear cable manager included
The CopperTen Augmented Category 6 Angled Patch Panel optimizes 10 Gb/s transmission
performance with offset jack positioning to counter the negative effects of alien crosstalk The angled port design improves all aspects in managing horizontal cable and patch cables while improving density when used with Glide Cable Management It also makes modifications easy, avoids unintended disconnects and cable damage, and protects bend radius to avoid violations that result in signal degradation.
An integral part of ADC’s TrueNet Structured Cabling System, CopperTen is the world’s first
UTP structured cabling system to enable 10 Gigabit Ethernet over a full 100 meters Installed in high-performance networks worldwide, the system’s patent-pending design minimizes alien crosstalk and insertion loss and meets the performance requirements of IEEE 802.3an and TIA 568-B.2-10 draft standards
Trang 16Copper Connectivity Solutions
TrueNet® Category 6 Structured Cabling Systems
The TrueNet Category 6 solution is a fully integrated family of precisely tuned components each designed
to operate at optimum performance with the other This solution is unmatched in data throughput and is supported by the most comprehensive and thorough warranty in the industry: the TrueNet Zero Bit-Error warranty The warranty guarantees that the structured cabling system will remain error free for a full 5 years and includes a 20-year electrical performance and free of defect warranty The result is a remarkable advanced and high performing end-to-end channel guaranteed beyond the typical industry requirements
to maximize network throughput and minimize downtime Numerous component options are available for versatility and flexible adaptation to meet any infrastructure requirement.
Data Cables
Patch Panels
Data Cables
XX = Jacket Color: BL = Blue, WT = White, GY = Gray, GN = Green, YL = Yellow, RD = Red
YY = Length: 02 = 1000 ft, 04 = 2000 ft, 05 = 2500 ft, RB = 1000 ft reel in a box
1 RU 24-port Patch Panels
Rear wire manager includedDesigned to support gigabit ethernet transmission speeds
•
•
•
•
Trang 17Right/left angle patch panel
O r d e r i n g I n f o r m a t i o n
KM8 RJ45 UTP modular 568A/B jack
XX = Color: WT = White, IV = Ivory, GY = Gray, BK = Black
O r d e r i n g I n f o r m a t i o n
Features
Patented right/left angle eases stress
on patch cords allowing for easy cable management
45-degree silver-plated IDCs provide secure reliable gas-tight connections
Wire can be terminated with either a KRONE
or 110 toolUniversal A/B wiring label
•
•
•
•
Trang 18Copper Connectivity Solutions
TrueNet® Category 6 Structured Cabling Systems
Patch Cords
Highband® 25 Blocks
RJ45-RJ45 plug UTP PVC patch cord
300-pair field assembly kit with back mount frame 6450 1 101-00
O r d e r i n g I n f o r m a t i o n
Features
Impedance matched patch cord for maximum throughput
Patented AirES Technology
Up to 28% smaller outer diameter than other patch cords
UL 1863 listed and Category 5e performance verified
•
•
•
Trang 19Faceplate Mounting Options
Ultim8 blocks
96-pair (24-port) field assembly kit, universal mounting system 6636 1 596-46
Patch Cords
Ultim8 - Ultim8 UTP straight through TP6TH-XXYY
XX = Color: BL= Blue, WT = White, GY = Gray, GN = Green, YL = Yellow, RD = Red
4-port all-fit surface mount box 6644 1 224-XX
XX = Color: 01 = White, 02 = Ivory, 03 = Gray, 04 = Black, 22 = Electrical Ivory
See ADC TrueNet Catalog for a wide range of faceplates, surface mount boxes and multimedia boxes
O r d e r i n g I n f o r m a t i o n
Features
Test port provides “look-both-ways” testing and circuit monitoring using ADC test cordsPerformance exceeds TIA/EIA Category 6 component specifications
Provides unique patch-by exception functionality
•
•
•
Trang 20Fiber Connectivity Solutions
TrueNet® TFP Series Fiber Panels
The TrueNet Fiber Connectivity portfolio is a
diverse family of products designed to operate
at optimum performance with each other This
solution is supported by the most comprehensive
and thorough warranty in the industry: the
TrueNet Zero Bit-Error Warranty The warranty
guarantees that the structured cabling system
will remain error free for a full 5 years and
includes a 20-year optical performance and free
of defect warranty The result is a remarkable
advanced and high performing end-to-end
channel guaranteed beyond the typical industry
requirement to maximize network throughput
and minimize downtime Numerous standard
component options are available for versatility
and flexible adaptation to meet any infrastructure
requirement
Configurations and catalog numbers listed below
are considered part of the TrueNet Fiber standard
portfolio and are readily available.
Features
Utilizes angle-left/angle-right adapters for easy access and bend radius protection Completely modular footprint for ease of use and maximum versatility
Rear access makes field termination or splicing fast and efficient
Best application: mounted in cabinets to
consolidate fiber from servers, switches, routers and SANs
•
•
•
•
Trang 21Termination only empty chassis; black
1 RU, accommodates 2 TFP modular adapter packs; black TFP-1UT00-000B
2 RU, accommodates 4 TFP modular adapter packs; black TFP-2UT00-000B
5 RU, accommodates 12 TFP modular adapter packs, T-handle; black TFP-5TT00-000B
TFP adapter packs
Loaded with 12 multimode LC (beige) adapters (total 24 fiber terminations)
Loaded with 6 multimode SC duplex (beige) adapters (total 12 fiber terminations)
Loaded with 12 multimode LC (aqua) adapters (total 24 fiber terminations)
Loaded with 6 multimode SC duplex (aqua) adapters (total 12 fiber terminations)
Loaded with 12 singlemode LC duplex (blue) adapters (total 24 fiber terminations)
Loaded with 6 singlemode SC duplex (blue) adapters (total 12 fiber terminations)
O r d e r i n g I n f o r m a t i o n