The AFD houses custom termination, termination/splice and slack storage panels for use as an above ground fiber cross-connect system.. Description Features and Benefits The AFD System •
Trang 1D I S T R I B U T I O N S Y S T E M
Trang 2The AFD above ground fiber distribution system provides access, storage and cable management for passive outside plant fiber optic installations The AFD houses custom termination, termination/splice and slack storage panels for use as an above ground fiber cross-connect system.
The AFD is a heavy-duty, weather-resistant cabinet providing superior cable manage-ment and protection of fibers The AFD is a single-sided cabinet designed to provide front access for both splicing and terminating fibers.
The cabinets are quickly installed utilizing ADC's exclusive fiberglass mounting sleeve system (FMS) Installed with a cover in an area where future growth is anticipated, the FMS can be used to store cables until growth necessitates the installation of a cabinet When the anticipated growth occurs, simply replace the cover with the appropriate adapter plate and mount the cabinet to the plate.
The cabinets may also be pole or wall mounted or installed onto a concrete pad.
Description
Features and Benefits The AFD System
• Rugged aluminum construction permits placement in high traffic areas
- Provides superior protection of cables, splices and panels, offering a long, corrosion-resistant, problem-free service life
• Positive door stop
- Prevents accidental closing and provides wind protection
• Industry standard latch with hasp for padlock provisions
- Door latches include built-in padlock hasp for additional security
• Available in light green or sand
- Aesthetically pleasing colors for pedestal and remote terminal applications
• Designed to meet Bellcore 487 and NEMA 4 specifications for durability
• Mounts to fiberglass mounting sleeve (FMS)
- FMS provides easy, quick installation with flexibility, excellent storage and protection of cables
• Pole mounting bracket available
- Allows cabinet to be mounted vertically on a pole
• Modular growth
- Consists of (9) mounting positions for modular placement of termination, termination/splice or slack storage panels for network flexibility and growth
The Cabinet
• All front access cabinet
• Modular panels allow up to 72 terminations, using standard connectors, 144 terminations with LX.5 adapter/connectors
• Slack storage panel provides superior cable management while allowing a single length patch cord
to be used within the cabinet The Panels
• Termination
- 12, 24, 36 and 48 termination panels available using standard connectors (24, 48, 72 and 96 using LX.5 adapter/connectors)
- Equipped with factory connectorized OSP cable stubs in lengths up to 400 meters
• Termination/Splice
- 12, 24, 36 and 48 fiber panels available using standard connectors (24, 48, 72 and 96 using LX.5 adapter/connectors)
Trang 3New Fiber Plant
Overlay
Feeder Cable
CENTRAL OFFICE
OFFICE PARK
(24 Fibers)
(12 Fibers) Growth
(12 Fibers)
(12 Fibers) (12 Fibers)
Distribution Cables AFD SYSTEM
AFD
Up to 36 Fibers
AFD SYSTEM
CENTRAL OFFICE
CENTRAL OFFICE
Up to 36 Fibers
AFD
Demarcation Point
ADC's above ground Fiber Serving Area Interface (FSAI) fiber cable management sys-tem has been specifically designed for outside plant applications including:
• feeder/distribution cross-connect
• fiber flexibility points: allows test, access, monitor of fiber circuits; rapid turn-up of service; economical upgrade of the network
• demarcation/collocation points
• fiber-in-the-loop (FITL) hub terminals
Trang 4(1) Mounting Position (9 Total)
Front View
AFD Cabinet (Front Door Open)
Template for
Configuring an
AFD System
Use this drawing as a
template as you design
your AFD System.
Copy this page, complete
and fax to your ADC
customer service
representative
Step One: Select a cabinet (choose color) (see page 6) Catalog Number _
Step Two: Select termination, termination/splice or blank panel(s) (see pages 6-8)
Storage Panel is recommended
Positions*
Total*
*Panels chosen must occupy <9 mounting positions
Step Three:Select a mounting option (sleeve, pad, wall or pole mount,
see pages 9-10)
Catalog Number _
Catalog Number _
Catalog Number _
Step Four: Patch Cords (see page 11) Catalog Number _ Quantity _
Trang 5AFD System
Sample
Configuration
Step One: Select a cabinet (choose color) Catalog Number AFD-09CGN
Step Two: Select termination, termination/splice or blank panel(s)
Storage Panel is required
Quantity Module Positions*
Total* 9
*Panels chosen must occupy <9 mounting positions
Step Three: Select a mounting option
Catalog Number FMS-20000 Catalog Number FCVR-200AFD09 Catalog Number FCVR-200CVR
Step Four: Patch Cords Catalog Number FPCM-SPFC-1.5M Quantity: 24
Trang 6Above Ground
Enclosures
Ordering Information
Step 1:
AFD Cabinet
AFD above ground cross-connect
cabinet Front access only.
Colors:
Sand Light Green
31" x 15.6" x 14.25"
(78.74 x 39.62 x 36.20 cm)
Ordering Information
Dimensions (H x W x D)
40 lbs (88.2 kg)
Weight
AFD-09SND AFD-09CGN
Catalog Number Description
23"
31"
15.6"
13.10"
14.25" 15.6"
Step 2:
Storage Panel
Vertical storage panel
Occupies three mounting positions
Ordering Information
AFD-3STORE
Catalog Number
17.5" x 4.46" x 2.25"
(44.45 x 11.33 x 5.72 cm)
Dimensions (H x W x D) Description
17.50"
4.46"
Step 2:
Blank Panels
1 2 3 4
Ordering Information
AFD-BLPT01 AFD-BLPT02 AFD-BLPT03 AFD-BLPT04
Catalog Number
17.5" x 1.5"
17.5" x 3"
17.5" x 4.5"
17.5" x 6"
Dimensions (H x W) Mounting Positions
Trang 7*See Diagram A for cable construction details.
Parameters for standard OSP cable:
Mode Field Diameter 1310 nm: 9.3+0.5um Mode Field Diameter 1550 nm: 10.5+1.0um
AFD- P D
Connector Type
Cable Armoring
D Dielectric
A Single Armor
Cable Stub Length (meters)
Example: 0 3 1 = 31 meters
1 2 5 = 125 meters
A B C D
Panel Type
Cable Construction*
L Loose Buffer Tube
R 12 Fiber Ribbon, Central Tube
Catalog Number
12 Position
24 Position
36 Position
48 Position
2 4 3 8 6 7 A B Y
PCFC PCST PCFC Zirconia Sleeve PCSC Zirconia Sleeve
ST® Receptacle PCSC
SC, 8° angled polish
FC, 8° angled polish LX.5™ angled polish
B C D E F G
Cable Fiber Count
12 Fiber
24 Fiber
36 Fiber
48 Fiber
72 Fiber
96 Fiber
Step 2:
AFD Termination
Module
Panel Type A
12 position
(24 position with LX.5™)
1 mounting position
Panel Type B
24 position (48 position with LX.5™)
2 mounting positions
Panel Type C
36 position (72 position with LX.5™)
3 mounting positions
Panel Type D
48 position (96 position with LX.5™)
4 mounting positions
17.5"
(44.75 cm)
10.42"
(26.47 cm)
17.5"
(44.75 cm)
10.42"
(26.47 cm)
17.5"
(44.75 cm)
10.42"
(26.47 cm)
17.5"
(44.75 cm)
10.42"
(26.47 cm)
1.5"
(3.81 cm)
3.0"
(15.24 cm)
- Factory-terminated
OSP cable (one per
module) shipped with
a customer defined
stub length (up to 400
meters)
- Splicing will be done in
a customer-provided
OSP splice enclosure
Trang 8Catalog Number AFD-TS
Splice Chip Type
1 2 3 4 6 7 8 N
Bare Fusion Heat Shrink Fusion Mechanical/Ribbon Rotary
Fiberlok®
Northern Telecom Raychem Universal
No Chip Included
Connector Type
PCFC PCST PCFC Zirconia Sleeve PCSC Zirconia Sleeve
ST® Receptacle for Build-out Attenuators PCSC
SC, 8° angled polish
FC, 8° angled polish LX.5™ angled polish
2 4 3 8 6 7 A B Y
Pigtail Type
A B
Single Fiber, Corning Ribbon, 12 Fiber Ribbon Unit
Panel Type
12 Position
24 Position
36 Position
48 Position
A B C D
Step 2:
AFD Termination/
Splice Module
- Installed with
factory-terminated pigtails,
routed to internal
splice tray(s)
- OSP cable spliced
directly within module
in the field
- One cable clamp is
provided with each
termination/splice
module
- Splice protection
sleeves are not
included Order
separately See
catalog 1038.
- Moisture blocking kits
and grounding kits for
armored OSP cables are
not included with
termination splice
modules Ordered
separately See
catalog 1038.
Panel Type A
12 position
(24 position with LX.5™)
1 mounting position
Panel Type B
24 position (48 position with LX.5™)
2 mounting positions
Panel Type C
36 position (72 position with LX.5™)
3 mounting positions
Panel Type D
48 position (96 position with LX.5™)
4 mounting positions
17.5"
(44.75 cm)
10.42"
(26.47 cm)
17.5"
(44.75 cm)
10.42"
(26.47 cm)
17.5"
(44.75 cm)
10.42"
(26.47 cm)
17.5"
(44.75 cm)
10.42"
(26.47 cm)
1.5"
(3.81 cm)
3.0"
(15.24 cm)
Trang 9Step 3:
AFD Cabinet
Mounting Options
Fiberglass In-ground
Mounting Sleeve
(recommended
mounting method)
Medium fiberglass mounting sleeve.
Recommended mounting sleeve See
below for adapter plate and cover requirements/options.
Adapter plate required for mounting AFD-100 cabinet to FMS-20000
sleeve One FCVR-200CVR required
to cover unused space.
Cover for covering second opening
on FMS-20000 mounting sleeve
Used when cabinet is being mounted onto sleeve.
(2) Covers for covering both openings
on FMS-20000 mounting sleeve
Used when cabinet will not be
installed onto mounting sleeve.
30" x 68" x 47"
(76.2 x 172.72 x 119.38 cm)
29.8" x 38.5"
(75.7 x 97.8 cm)
29.8" x 38.5"
(75.7 x 97.8 cm)
Each Cover:
29.8" x 38.5"
(75.7 x 97.8 cm)
Ordering Information
Dimensions (H x W x D)
245 lbs (111.4 kg)
120 lbs (54.5 kg)
145 lbs (65.9 kg)
Each Cover:
145 lbs (65.9 kg)
Weight
FMS-20000
FCVR-200AFD09
FCVR-200CVR
FCVR-200CVRS
Catalog Number Description
,
,
AFD
FCVR-200 AFD09 FCVR-200CVR
FMS-20000
15.6"
14.25"
31"
30.0"
47.0"
68.0"
29.81"
38.5"
Trang 10Pole mounting kit for AFD Sand
Green
Ordering Information
AFD-09PMK-SDN AFD-09PMK-GRN
Catalog Number Description
Pole Mounting
AFD Pole Mount
Concrete pad mount
frame For use with AFD
cabinets only
20" x 17" x 6"
(50.8 x 43.18 x 15.24 cm)
Ordering Information
Dimensions (H x W x D)
AFD-09PMF
Catalog Number
35 lbs
(15.88 kg)
Weight Description
FLEXIBLE INNER DUCT
6.00" minimum (15.20 cm)
4.00" minimum (10.20 cm) to 6.00"
(15.20 cm)
1.00"
(2.54 cm) 4.00" (10.20 cm)
90 ° BEND CONDUIT
SAND OR GRAVEL
COMPACTED SOIL
Step 3:
AFD Cabinet
Mounting
Options
Concrete Pad
Mounting
Wall Mounting
Wall mounting kit for AFD Sand
Green
Ordering Information
AFD-09WMK-SND AFD-09WMK-GRN
Catalog Number Description
AFD Wall Mount
Pole attachment straps and clamps not included.
Hardware for mounting to wall not included.
Trang 11Catalog Number _ _ - _ - _ - 1.5M Cable/Fiber Option
Corning Fiber (connector
on both ends) Lucent Fiber (connector
on both ends)
Singlemode Connector Type
SPFC SPST SPSC APFC APSC AE2
Ultra PCFC Ultra PCST Ultra PCSC Angled PCFC 8° Angled PCSC 8° Angled E-2000
For hybrid patch cords: enter both connector types in this field Separate them with a slash mark Example: FPC-SPFC/PSC-S-3M
Length (in meters)
FPC
S D L
Corning SMF-28 or Lucent Depressed Cladding Corning SMF-DS (Dispersion Shifted) Corning SMF-LS (Longspan Dispersion Shifted)
Configuration Option
Standard 3 mm cable Dual cable (2.5 x 3.4 mm)*
900 micron cable Dual zip cable*
D 9 Z
LEAVE BLANK
Step 4:
Ultra Physical
Contact Fiber
Optic Patch
Cords
* Standard breakout is 18" Contact ADC Customer Service for additional breakout options
Catalog Number _ _ _ - 1.5M-
Cable/Fiber Option
Singlemode Connector Type
Length in Meters
FPC Corning Fiber (connector on both ends) FPA Lucent Fiber
(connector on both ends)
2 M
2.0 mm dual zip*
2.0 mm single
SPFC SPSC SPST APFC APSC AE2
Ultra PCFC Ultra PCSC Ultra PCST Angled PCFC 8° Angled PCSC 8° Angled E-2000
Configuration Option
* Standard breakout is 18"
Contact ADC Customer Service for additional breakout options
For hybrid patch cords, enter both
connector types in this field
Separate them with a slash mark Example: FPC2-SPFC/PSC-1.5M
3mm Cable
Singlemode
2mm Cable
Singlemode
For hybrid patch cords, enter both
connector types in this field
Separate them with a slash mark Example: FPC2-SPFC/PSC-1.5M
1.7mm Cable
Singlemode
Catalog Number _ _ _ - 1.5M-
Cable/Fiber Option
Singlemode Connector Type
Length in Meters
FPC Corning Fiber (connector on both ends) FPA Lucent Fiber
(connector on both ends)
Configuration Option
ALX5 Angled LX.5™
* Standard breakout is 18"
Contact ADC Customer Service
Trang 12From North America, Call Toll Free: 1-800-366-3891, Ext 3475
Outside of North America: +1-612-938-8080
FAX: (612) 946-3292
Web Site: http://www.adc.com
For a complete listing of ADC's international sales office locations, please refer to our web site.
Specifications published here are current as of the date of publication of this document Because we are continuously improving our products, ADC reserves the right to change specifications
ADC Telecommunications, Inc.
P.O Box 1101 Minneapolis, Minnesota 55440-1101
Longitudinal Ripcord
MDPE Outer Jacket Water Blocking Tape
Longitudinal Ripcord
Outer Strength Members
Water Blocking Agent
Filled Tubes Containing Optical Fibers
Dielectric Central Member
Longitudinal Ripcord
MDPE Jacket Water Blocking Agent
Longitudinal Ripcord
Corrugated Steel Armor
Water Blocking Agent
Outer Strength Members Water Blocking Tape Filled Tubes Containing Optical Fibers
Dielectric Central Member
Ripcord Water Blocking Element
Fiber Ribbons
Filled Buffer Tube
Ripcord Dielectric
Strength Members Barrier
Tape MDPE
Ripcord Water Blocking Element
Fiber Ribbons
Filled Buffer Tube
Ripcord Dielectric
Strength Members Barrier
Tape MDPE
For additional cable types, please contact your ADC sales representative
Diagram A