CASE STUDYIndoor Wireless Coverage Multilevel Corporate Technology Campus Customer A global telecommunications manufacturer recently moved into a new 500,000-square-foot world headquarte
Trang 1CASE STUDY
Indoor Wireless Coverage
Multilevel Corporate Technology Campus
Customer
A global telecommunications manufacturer recently moved into a new 500,000-square-foot world headquarters facility housing just under 5,000 employees Two major wireless service providers supplied service
to a majority of the company’s mobile phone users Nearly 60 percent of those phone users at the new campus complained they could not make
or receive wireless calls within the facility
The Problem
Mobile phones have become a primary means of communication in many people’s lives, including those working within this company’s customer service department But as employees moved into the new state-of-the-art facility, it became apparent that this vital line of communication was in jeopardy
The new facility is a three-building campus, constructed of brick, concrete, and steel, with extensive use of low-e, architectural and solar glass Each three-story building has one or two levels below ground The buildings are connected by skyways and an 8-foot concrete basement tunnel The construction materials used throughout the facility make transmitting and receiving RF signals extremely difficult Inside, the design of the facility created many more challenges due to its open architecture and frequent use of 3-foot-thick concrete pillars, hampering quality wireless coverage throughout the facility
Trang 2CASE STUDY
The company has placed a premium on customer service, and a critical benchmark to that is the
customer’s ability to reach a knowledgeable customer service person on the first call For this reason, many customer service representatives forward their desk calls to their mobile phone when away from their desk But if they couldn’t receive mobile calls within the facility, they wouldn’t be able to maintain their excellent level of customer service
The ADC Solution
The alternatives for providing RF coverage within the new facility were less than ideal The company studied many possible options to solve the problem, but most were either too expensive or sacrificed quality for cost savings One option was to place base transceiver stations (BTS) within the facility Base stations are typically only used for in-building applications when the call capacity required within the building justifies offloading traffic from the macro system The potential revenue from the
in-building coverage would need to be extremely high to justify the cost of a BTS Another option was to radiate the signal through “leaky coaxial” cable While this is a low-cost alternative, it requires added amplification to maintain signal strength, resulting in degradation of the signal-to-noise ratio Still another consideration was to install a wireless office system in only the building that customer service representatives worked, but this would restrict their mobility and hamper them from receiving customers’ calls while in other parts of the campus
The client’s Network Technology Services department chose ADC’s Digivance® Indoor Coverage Solution for its flexibility and scalability, and because it’s the only all-digital distributed antenna system (DAS) that transports RF signals digitally within buildings ADC’s systems engineers performed the initial design, conducted a walk-through to measure signal levels throughout the building, and determined the necessary equipment ADC’s Systems Integration engineers then routed the cables and installed the equipment
Because 85 percent of the mobile service used by this company’s employees is primarily provided through two different service providers, the system was designed to accommodate both of the major service providers RF signals are relayed to the building via airlink from two directional antennas placed on the roof Each antenna points toward the nearest macro cell site for the specified service provider The Digivance ICS system then interfaces with the cell sites through Digivance Remote Interface Units (RIU), which provide necessary signal level adjustments on both the uplink and downlink paths
By using ADC’s patented technology, the Digivance ICS digitizes the entire designated RF band and digitally transports it over fiber, a technology through which signals are replicated at full dynamic
range regardless of the fiber length or number of splits Digital RF transport introduces no loss due to attenuation and no degradation of the quality of the signal Because the entire bandwidth is digitized, transportation of the signal is transparent to modulation technology, and the signal is reconstructed at full bandwidth In addition, balancing the system is not required, saving valuable installation and setup time ADC’s patented digital RF transport technology also maintains the signal’s high dynamic range, which increases the capability for data throughput and enables the system to handle the high data rates
of broadband service
The Digivance ICS system is modular, consisting of a digital host unit (DHU), optional digital expansion unit (DEU), and digital remote units (DRU) The modules are connected by pairs of multimode fiber The flexible architecture allows DRUs to be connected either directly to the DHU or indirectly connected via the DEU Each DHU and DEU can accommodate up to six connections, either additional DEUs or DRUs DEUs can be daisy-chained without affecting system performance Additional DRUs can then be added, with the only limitation being the noise figure (Noise figure can be calculated using the formula 8 dB + [10 log N] where N is the number of antennas.) Digivance ICS is a cost-effective, flexible system that maintains end-to-end gain characteristics while allowing network planners to optimize indoor coverage for their specific environment
Trang 3CASE STUDY
The Digivance ICS’ flexible features easily accommodate the building’s open architecture challenges with
the ability to transport signals 1500 to 2250 feet In the many wide-open areas (some as long as 50
feet) cables had to be “home run,” or run down to the basement and back up through another riser
For many indoor coverage products that use fiber to their expansion hub and Category 5 cable to the
remote antennas, this would require the use of many expansion hubs - each having unused ports - and
the system would quickly become cost-prohibitive Digivance ICS digitizes the signal and transports it
over fiber between the DEU and the DRU, and because fiber length does not impact signal quality within
the optical budget operating window, the home runs were not a problem for the Digivance ICS system
Benefits Realized by the Customer
Since it’s installation, the Digivance ICS has been given high marks by employees at the facility All of the
employees using the two selected service providers reported an increase in their wireless coverage, and
of those, 70 percent said they have since increased minutes of use as a direct result
The following diagram illustrates how the Digivance ICS was designed to provide the best solution
throughout the client’s facility Measurements indicate signal strength (RSSI) prior to and immediately
following installation
The new system has been a win-win situation for the company as well as the two major wireless service
providers The company’s customer service representatives, whose constant, uninhibited contact with the
outside world is critical to their company’s bottom line, can now conduct business clearly The service
providers who rely on the business of these customers have experienced +20 dB or more in signal
improvement, and dropped calls have been eliminated as a result The increase in usage has resulted in
increased potential for new revenue and greater customer satisfaction
DRU DRU
DRU DRU
Digital Host Unit
RF Input
RF Output
DRU DRU DRU
DRU DRU
Digital Expansion Unit
DRU DRU
DRU DRU
Digital Expansion Unit
DRU DRU
DRU
DRU DRU
Digital Expansion Unit
DRU DRU DRU
DRU DRU
Digital Expansion Unit
DRU
Trang 4-70 -70
-(95)
-70
-(95)
-80
-(95)
-60
-(97)
-60 -75
-80 -70
-(97)
-65
-(97)
-70 -80
-101
-70
-(101)
-60
-101
-70
-(93)
-80
-85
-(93)
-80
-(93)
Client's Facility – Building C
Client's Facility – Building B
Client's Facility – Building A
-65 -75
-70
-(95)
-67
-(95)
-65
-(93) -75
-(97)
-70
-(95)
-60
-55 -60
-(97)
-65
-(95)
-70 -70
-(93)
-80
-(97)
-70
-(95)
-65
-100
measurement point DRU and antenna
Note: All values noted in dBm
Numbers in parentheses are interpolated values.
-70
-100
Signal strength without in-building coverage Signal strength with Digivance ICS
Signal strength improvement
95.147 Average
70.353
24.794
Web Site: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our Web site.
ADC Telecommunications, Inc., P.O Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice At any time, you may verify product specifications by contacting our headquarters office in Minneapolis ADC Telecommunications, Inc views its patent portfolio as an important corporate asset and vigorously enforces its patents Products or features contained herein may be covered by one or more U.S or foreign patents An Equal Opportunity Employer