Multifunction Swing-Out Universal Chassis Loaded with a fiber, DS1 and DS3 module Multifunction Swing-Out Chassis Loaded with one CSU and an 8-termination front • 4- and 8-termination D
Trang 12nd Edition
Trang 33/08
Multifunction Panel
Introduction and Applications 1
Modules DS1 Interconnect Module: 4-Termination 4
DS1 Interconnect Module: 8-Termination 4
DS1 Monitor Module 4
DS1 Front Cross-Connect Module: 8-Termination 5
DS3 Interconnect Module 6
Individual DS3 Circuit 6
Splice/Storage Fiber Plug-In Module: 6-Termination 7
Ethernet Category 5e Module 7
Module Ordering Information 8
Chassis Ordering Information Swing-out Chassis 10
Bulkhead Chassis 10
QCP Wire Distribution Panels Introduction and Applications 11
QCP Standard Panel Ordering Information 200/400-Pair Standard Panel – 19" EIA 12
200/400-Pair Standard Panel – 23" WECO 12
300/600-Pair Standard Panel – 19" EIA 13
300/600-Pair Standard Panel – 23" WECO 13
QCP DCS Panel Ordering Information 14
QCP Accessories Ordering Information 15
Impedance Matching Panel Introduction and Applications 16
Impedance Matching Panel Ordering Information 18
Wired Assemblies Introduction and Applications 19
Bantam Connectorized Jackfields 2-wire Jackfield 21
4-wire Jackfield 21
6-wire Jackfield 21
Ordering Information 22
Voice Frequency Jackfield Ordering Information 23
Bantam Prewired Jackfields 2-wire Jackfield 24
4-wire Jackfield 24
6-wire Jackfield 24
Ordering Information 25
Telephone Line Isolation Panel Ordering Information 27
Timing Jackfields Ordering Information 28
Trang 4•
Connectorized Cables
Introduction 29
Category 2, 3 and 5 Cables Ordering Information 30
Terminal Blocks Connectorized Terminal Blocks Ordering Information 31
Wire-wrap Terminal Blocks Ordering Information 32
Molded Terminal Blocks Ordering Information 32
Terminal Blocks Accessories Ordering Information 33
Specifications QCP Wire Distribution Panels 34
Impedance Matching Panel 36
Wired Assemblies 37
Connectorized Cables 49
Connectorized Terminal Blocks 53
Index 56
Table of Contents
Trang 5Multifunction Panel 1
QCP Wire Distribution Panels 11
Impedance Matching Panel 16
Wired Assemblies 19
Connectorized Cables 29
Terminal Blocks 31
Specifications 34
Index 56
Trang 7Multifunction Swing-Out Universal Chassis
(Loaded with a fiber, DS1 and DS3 module)
Multifunction Swing-Out Chassis
(Loaded with one CSU and an 8-termination front
• 4- and 8-termination DS1 interconnect modules available in wire-wrap or RJ IN/OUT connections
• 8-termination monitor module
• 8-termination DSX-1 cross-connect modules available in wire-wrap or RJ IN/OUT connections
• 1-circuit DS3 MPOP interconnect module with a modular design for growth up to three DS3 circuits
• Fiber connector module
• CSU mounting shelf
• 4-termination Cat 5e Ethernet module
Trang 8Customer Premise Applications
As end customers require more and more services, service providers (CAPs, CATV, utilities and RBOCs) are taking a more active role in providing and maintaining the switch services at the customer premises location Figure 1 shows an integrated access concentrator at the customer premises location, with the multifunction panel providing a demarcation point, as well as nonintrusive monitoring, testing and patching, all within one integrated chassis.
Wireless Cell Site Applications
In today’s competitive wireless market, the ability to test, monitor and patch the RF signal prior
to sending the signal is essential in ensuring the downstream signal’s quality Figure 2 illustrates
a typical base station with incoming signals connected to the multifunction panel before going
to the up/down converter.
MUX DS3 T1 Voice Data SONET
Multifunction Panel MultifunctionPanel with
RF Module
Up/Down Converter Radio
Equipment
Demarcation
Multifunction Panel MultifunctionPanel
T1/E1 OR T3/STS-1
Integrated Access Concentrator
Protector
Demarcation
Figure 2 Figure 1
Trang 9Wireless Multifunction Panel with DS1, DS3, Ethernet or Fiber Applications
The multifuction panel enables patching, termination and rearranging of circuits as traffic patterns change and demands on the network grow It connects network elements such as office repeaters, digital switches, channel banks, digital loop carriers, multiplexers and digital loop switches.
MTSO
Mobile Telephone Switching Office
Option 1: Mutifunction Panel with DSX
DS3 Module M3/1 DSX BTS
Cross-Connect w/ Loopback
N E T W O R K
Multifunction Panel
Cross-Base Station
Plexer
Multi-Option 2: Mutifunction Panel
FDP
Figure 3
(Cellular/PCS Site Options)
Trang 10MFP-261001
Trang 13Ethernet Category 5e Module
MFP 242003-8W6-Termination
Trang 14Additional configurations available.
DS1 interconnect modules
For applications in which cross-connect functionality is not required
4-termination – supports 2 T1 circuits
8-termination – supports 4 T1 circuits
14-termination – supports up to 7 T1 circuits
DS1 monitor module
8 circuit DS1 with monitor ports front IN/OUT RJ48X, Rear wire-wrap IN/OUT
MFP-261001
DS1 front cross-connect module
8-termination – supports 4 T1 circuits
One-position interconnect module with space for growth; total capacity of 3 DS3 circuits
Individual DS3 circuits
O r d e r i n g I n f o r m a t i o n
Trang 15Splice/storage fiber plug-in module
6-position splice chips for fiber module
Trang 163-position, swing-out chassis, front and rear access,
cable management for twisted pair, fiber and coax,
mounts in 19" (483 mm) or 23" (584 mm) EIA/WECO
racks or wall mount, adjustable flush, 25 mm (1"), 51
mm (2") or 127 mm (5") mounting
89 mm x 439 mm x 267 mm (3.5" x 17.3" x 10.5")
Trang 17• Circuit traceability and simplicity in wiring.
• Greater accuracy resulting in less time required during system installation, maintenance and future updating since all contacts are color-coded and all connections are made at the front of the QCP bays
• Easy accommodation of traffic pattern changes, since reconfiguring is done mostly
at the front of the QCP bays
• Simpler office layouts, since office equipment can be installed where space is available The QCP system is then installed in the same equipment rack for rack lineup and serves
as the intermediate distribution frame for that equipment
• Greater accuracy in office record-keeping, since the panel labeling and color-coding correspond to office record keeping formats
Features
• Color-coded wire termination contacts
• Fanning panels and wireways to keep all
wire parallel with minimum crossover
• Easy to read panel designations on
white panels
• Single-sided frame administration
• Various densities of wire termination are
available, with the maximum density allowing up to 10,000 terminations on
an 8’ bay Circuit identification and wire routing are still manageable, even at these maximum densities
ADC’s quick connect panel (QCP) provides an
excellent means of connecting communications
circuits displaying easy circuit identification and
efficient wire management.
Wire Termination Contacts
This panel is available with either the insulation
displacement split cylinder contacts or wire-wrap
pins The split cylinder contact provides for a
quick punch-down method of termination, which
is much faster than other methods requiring
patch cords, soldering, or wire-wrapping; yet
this contact termination is just as reliable as
wire-wrapping The QCP insulation displacement
contact evenly distributes the holding force of
the cylinder, allowing many insertion/withdrawal
cycles and providing strain relief for the wire
resulting in a safe insulated termination This
contact furnishes a gas tight connection, while
handling a variety of wire types.
Cable and Wire Routing
QCP Panels are provided with an arrangement of
fanning panels and wireways for easy wiring and
minimal wire congestion A quadrant dressing
scheme is used to route wires to the side of the
bay and then up or down the vertical wireways,
either to other panels or to an express trough
to another bay The backsides of the bays are
provided with brackets for easy routing and tying
of cables.
See pages 34-35 for specifications.
Individual QCP Cylinder
Correct Strain Relief for Wire
Stress Point Caused by Incorrect Strain Relief
Trang 18QCP Wire Distribution Panel
Standard Panel (200/400-Pair)
19" EIA 1.75" rack spacing
Connectorized panels with rear 50-pin plug connector
23" WECO 2" rack spacing
Connectorized panels with rear 50-pin plug connector
Non-connectorized panels
O r d e r i n g I n f o r m a t i o n
Custom panels are available Minimum quantities apply
Trang 19Standard Panel (300/600-Pair)
19" EIA 1.75" rack spacing
Connectorized panels with rear 50-pin plug connector
Non-connectorized panels
23" WECO 2" rack spacing
Connectorized panels with rear 50-pin plug connector
Non-connectorized panels
O r d e r i n g I n f o r m a t i o n
Custom panels are available Minimum quantities apply
Trang 20Features and Benefits
• Convenient access point to monitor, test or
reconfigure circuits, eliminating work on the DCS backplane and enabling troubleshooting without uncabling
• Preplanned, durable access point for
troubleshooting in a "direct connect"
application: a 1 for 1 circuit connection, through the front and rear side of the same termination contact by terminating network element wires on the front and the DCS cable
on the back of the panel
• In an interconnect application, allows rerouting
of circuits by terminating the DCS and network element cables on the rear of the panel and interconnecting them on the front
• Available in 112- and 224-circuit sizes The 112-
circuit panel is configured with pin groups of 4x28 and provides the easiest work access The 224-circuit panel is configured with pin groups
of 8x28 and provides the highest termination density, saving space
• Excellent cable management with a variety of filler panels, stand-off brackets, fanning panels, fanning rings and dust covers
• Available with shield pins as optional bonding points If used, the shield pins provide a means for DCS/network element sheath continuity
• Easily tested without clipping shortened pigtails within the same cable sheath The QCP contacts are available for applications needing frequent test access
• Centralized termination, interconnection and access to digital transmission lines between the DCS and the network elements
• An alternative to hardwiring digital telecommunications equipment directly
to the DCS
• A fallback option for interconnection of network elements if the DCS fails
Connectorized panel wire-wrap
Trang 21QCP replacement kit includes instructions and the following:
Trang 22The 75/120 Ohm impedance-matching panel provides a solution for incompatible network interfaces
by creating an interchange between twisted pair and coaxial network elements A balun converts the unbalanced 75 Ohm impedance of a coaxial cable into the balanced 120 Ohm impedance of a twisted pair While ensuring quality and reliability, the panel allows continuous signal transmission through otherwise incompatible interfaces Frequently used in central office environments, this panel is often deployed by system integrators in co-location facilities.
Trang 23The impedance matching panel ensures digital signal reliability during the conversion from 75 Ohms
to 120 Ohms This panel is ideal for central office and co-location facilities where original equipment manufacturer (OEM) product interface incompatibilities frequently occur.
NetworkElement A
NetworkElement BTwisted Pair
Features and Benefits
Panels available with 8, 16, 24, or 32 circuits
Easily matches existing network equipment circuit counts
Multiple connector interface type and location options
Variety of configurations available to complement existing network designs
Preinstalled cable management bars
Reduces cable congestion and simplifies maintenance
Cable management rings with labeling
Ensures proper cable routing and circuit identification
Reversible mounting brackets
Each panel fits into 19" or 23-inch racks, or can be wall mounted
Support signal rates up to E1 (2.048 Mbps)
Impedance Matching Bay in Network
Trang 24Impedance Matching Panel
Balun Interface Location
Catalog Number BAL - F -
Balun Interface Type
D 64-pin plug connectors
See page 36 for panel dimensions and specifications
* Minimum order required for these connectors
Trang 25In the central office, wired assembly jackfields,
inserted into VF circuits between different office
equipment, provide jack access for testing and
rerouting (patching) circuits.
Pioneered by ADC, these jackfields with bantam
jacks are available in a prewired, prewired
and connectorized, or connectorized only
configuration; and completely assembled in our
plant No need for expensive wiring connections
in the field ADC bantam jackfields are available
in virtually any circuit configuration required
Included are 2-wire, 4-wire, and 6-wire circuits
for primary, secondary, intermediate, test and
out-of-service functions Equally important, each
jackfield is checked, inspected and tested in
our plant.
See pages 37-48 for Specifications
JC6/48M
Trang 26MOD EQ OUT MON
M E
M E
LINE EQ SIG
T1 R1 R T RECEIVE TRANSMIT
4-WIRE ANALOG TRUNK
SB SG
DEM EQ IN
MOD EQ OUT
MON
Trang 27The JC4 bantam jackfield provides 24
four-wire circuits,including monitor jacks
Circuit connections are made through standard
50-pin connectors on the rear of the chassis
Equipment IN and MOD are receptacles;
Equipment OUT and DEMOD are plugs
• Front panel hinged for internal access
• Horizontal designation strips furnished
with a white card and clear window for circuit identification
• Vertical designation cards printed with
row functions
4-Wire Jackfield
6-Wire Jackfield
R T1
LINE DROP R T1
LINE DROP/
MON
R T
LINE DROP MON
R1 T1
DEM EQ IN MON
MOD EQ OUT MON
R T
R1 T1
DEM EQ IN
MOD EQ OUT
R T
JC4/24M
JC4/24
R1 T1
DEM EQ IN MON
MOD EQ OUT MON
R T
M E E M
LINE EQ SIG
JC6/48M
Features
The JC2 bantam jackfield provides 48
two-wire circuits, including monitor jacks Circuit
connections are made through standard 50-pin
connectors mounted on the rear of the chassis
Line connectors are receptacles, drops are plugs
• Front panel hinged for internal access
• Horizontal designation strips furnished
with a white card and clear window for circuit identification
• Vertical designation cards printed with
row functions
Features
The JC6 bantam jackfield provides 12 or 48
six-wire circuits, consisting of DEM/MOD, EQ
IN/ EQ OUT, MOD and Signal jacks Circuit
connections are made through standard 50-pin
connectors on the rear of the chassis Equipment
IN and MOD are receptacles; Equipment OUT
and DEMOD are plugs
• Front panel hinged for internal access
• Horizontal designation strips furnished
with a white card and clear window for circuit identification
• Vertical designation cards printed with
row functions
Trang 28Bantam Connectorized Jackfields
2-wire jackfield
With primary Line/Drop or
Signal E/M
45 mm x 483 mm x 203 mm (1.75" x 19" x 8")
With primary Line/Drop or Signal E/
M plus a third row of monitor jacks
With Voice Frequency jacks,
(1.75" x 19" x 8")
With Voice Frequency jacks, DEM/
MOD, EQ IN/EQ OUT, monitor jacks
6-wire jackfield
With monitor and signal E/M jacks;
signal jacks on right side of panel
45 mm x 483 mm x 203 mm (1.75" x 19" x 8")
Trang 29Bantam Connectorized Jackfields
Voice Frequency Jackfield
ADC voice frequency (VF) jackfields support the network manager who needs to access, monitor, test and patch VF circuits VF jackfields allow monitoring and testing of VF circuits, on either side of the line (telco or modem, transmit or receive), without circuit interruption Circuit paths for both 2-wire and 4-wire lines can be changed with a single action ADC VF jackfields save space, are easily installed and aid in VF line organization Special plugs to split, open and terminate lines are available.
Features
ADC’s voice frequency jackfield provides complete
access and patch facilities for 24 four-wire or 48
two-wire lines LINE and MODEM jacks on the
front allow patching of any line to any modem
access for test equipment Front panel MONITOR
jack access provides a bridging connection
across the line All jacks are prewired to 50-pin
connectors located at the rear of the panel The
jacks accept three conductor bantam plugs (two
conductors plus braided shield)
• Horizontal designation strips furnished with
a white card and clear window for circuit identification
• Row functions are permanently marked for
ease of operation
• Plexiglass dust cover provided
• FCC registered (Part 68)
R T
LINE MOD MON TRANSMIT
LINE MOD MON
R T
RECEIVE
DMMOJ-1
(1.75" x 19" x 8")
DMMOJ-1
O r d e r i n g I n f o r m a t i o n
Trang 30The JB4 bantam jackfield provides 24
four-wire circuits, including monitor jacks Circuit
connections are made by wiring the equipment
to easy-access wire-wrap terminal blocks on the
back of the jackfield
• Front panel hinged for internal access
• Horizontal designation strips furnished
with a white card and clear window for circuit identification
• Vertical designation cards printed with
row functions
4-Wire Jackfield
6-Wire Jackfield
Features
The JB2 bantam jackfield provides 48 or 96
two-wire circuits, including monitor jacks Circuit
connections are made by wiring the equipment
to easy-access wire-wrap terminal blocks on the
back of the jackfield
• Front panel hinged for internal access
• Horizontal designation strips furnished
with a white card and clear window for circuit identification
• Vertical designation cards printed with
row functions
Features
The JB6 bantam jackfield provides 12 or 48
six-wire circuits, consisting of DEM/MOD, EQ
IN/EQ OUT, MON and Signal jacks Circuit
connections are made by wiring the equipment
to easy-access wire-wrap terminal blocks on
the back of the jackfield
• Front panel hinged for internal access
DEM EQ IN MON
MOD EQ OUT MON
R T
JB4/24M
R T
LINE DROP MON
JB2/48M
Trang 31Bantam Prewired Jackfields
2-wire jackfield
With primary Line/Drop or Signal E/M
plus a third row of monitor jacks
45 mm x 483 mm x 203 mm (1.75" x 19" x 8")
4-wire jackfield
With Voice Frequency jacks,
(1.75" x 19" x 8")
With Voice Frequency jacks, DEM/
MOD, EQ IN/EQ OUT, monitor jacks
Trang 32Telephone Line Isolation Panel
The telephone line isolation panel provides a safe
and easy means of accessing phone lines for
testing at power substations and also provides
lightening protection
The PI-250 panel and associated plugs are
specially designed to provide protection up to
20,000 volts between the line side and the
equipment side as well as between the adjacent
circuits within the panel The panels are available
in several versions The three types of available
plugs; looping plugs, shorting plugs and reverse
polarity plugs have color-coded handles for
easy identification.
The panel is usually located at or near the
demarcation between the telephone company’s
in-plant or building wiring, usually at the point of
entrance into the building The panel allows line
access for repair personnel while protecting them
from high voltages on the lines during electrical
storms and power failures.
One side of the panel is the telephone company
side where telephone cables enter the power
substations The other side is the power
company equipment side To open the phone
circuits for testing in either direction, you simply
remove the plugs from the panel, opening the
phone company lines from the power company
equipment Lines can be accessed in both
directions through telephone type jacks,
recessed within the molded panel in such a way
as to make accidental contact with the jacks
extremely difficult.
The isolation panel is completely enclosed in
a transparent safety shield, making it virtually
impossible for test personnel to come in contact
with the active circuits The specially designed
ADC plugs are rated at 20,000 volts, well over
the necessary protection level.
ADC’s telephone line isolation panel also provides
a less time-consuming, less costly and more
efficient means of access No more unwrapping
circuits or breaking solder connections All
you do is remove a plug and your circuits are
automatically disconnected for testing.
Telephone Isolation Panel Jack Schematic
TO ISOLATING DEVICE
CENTRAL OFFICE
Looping Plug
(PJ40)
TO ISOLATING DEVICE
OFFICE
Reverse Polarity Plug
(PJ42)
Trang 33Telephone Line Isolation Panel
Height shown is the height of the panels with plug Without the plugs, the height of panels with wire-wrap terminations is 13.18 mm (5.19"); the height of the panels with screw terminals is 13.72 mm (5.4")
Panels with wire-wrap terminations
PI-250-8
Plugs
O r d e r i n g I n f o r m a t i o n
Trang 34Timing jackfields provide 20 circuits for
termination of a timing source generator
These panels provide patching and monitoring
capabilities for T1 clock output The panels’
outputs are individually cabled to any piece of
equipment requiring a T1 clock.
Timing jackfields
Bantam timing jackfield;
2-wire digital jackfield;
includes monitor jacks
89 mm x 483 mm x 203 mm
AUX-3A0001
Bantam timing jackfield;
2-wire digital jackfield;
includes monitor jacks;
terminal blocks are jumpered
AUX-3A0003
O r d e r i n g I n f o r m a t i o n