find strategy to maneuver power level by controlling - control rod movement with automatic boron ppm, or - control boron pppm with automatic control rod. - fully withdrawn position is 38[r]
Trang 16 e-CORSIM practice
Jonghwa Chang jhchang@kaeri.re.kr
Trang 2Input MAS_INP
XS-Library
Restart MAS_RST
Output MAS_OUT
Summary MAS_SUM
Restart MAS_RST
Pin Info.
MAS_PPI MAS_PEI
MAS_PPI: Pin by Pin Information File MAS_PEI: Pin Enthalpy File
MASTER interface files
MASTER : A 3D nodal diffusion code developed by KAERI
Trang 3- Pause before next phase
- Read and execute fragmented input
- Show key parameter to GUI at the end of a phase
GUI feature :
- Initialize by reading master input
- Display key parameters on user demand
- Activate controls
- Prepare fragmented input for MASTER (EXE and EDT card)
- Invoke MASTER and wait
e‐CORSIM flow
• e-CORSIM is a graphic user interface for MASTER training course
MASTER status diagram
Trang 4setup: e-Cosim Setup.msi
Installed directory structure
Trang 5L/P search – setup loading pattern
Xenon transient – Xenon oscillation or Load following simulation
Trang 6Cycle 1 Cycle 2 Cycle 3 Cycle 4 Cycle 5 Cycle 6 Cycle 7
Trang 7FA Type
Fuel Enrichment (w/o U-235) No of Fuel Rods per FA No of BA Rods per
FA
BA Content (w/o)
Loaded Cycle Normal Zoned Normal Zoned
Trang 8FA Type
Fuel Enrichment (w/o U-235) No of Fuel Rods per FA No of BA Rods per
FA
BA Content (w/o)
Loaded Cycle Normal Zoned Normal Zoned
Trang 9D2 F2,G2,H2,J2,K2,K6 K4
Trang 10 With Axial Cutback
5%
5%
Trang 115 - Lead Regulating Bank
4 - Second Regulating Bank
3 - Third Regulating Bank
2 - Fourth Regulating Bank
1 - Fifth Regulating Bank
Trang 12180°
270°90°
M
M
M M
8 ADDITIONAL LOCATIONS FOR SHUTDOWN CEA’S
45 FIXED RHODIUM IN-CORE NEUTRON DETECTOR STRINGS
2 NEUTRON SOURCE ASSEMBLIES
(M) (S) (●) (◆)
4-finger
12-finger
Trang 13FA ID
180°
270°90°
Trang 14FA ID Previous Cycle Location
180°
270°90°
M-12 D2 L-03 D1 D-03 C1 K-12 B0 B-12 B0 J-07 B0 P-12 C1 F-12 D1 M-03 D2 E-03 C1 D-12 D0
P-11 D2
C1
C1 P-07 D0 H-15 C1
C1
D2 N-11 D0 B-11
E0 D1
C-04 C1 F-06 D2 G-05 B2 J-13 C0 R-07 B1 H-07 C0 A-07 B2 G-13 D2 L-07 C1 L-05 D1
E0 D2
F-02 B0 M-02 C1 G-14 C0 G-15 B2 F-08 C0 N-13 C1 H-14 C0 C-13 B2 H-04 C0 J-15 C1 J-14 B0 D-02 D2
D2
B0 G-07 D0 R-08 B1
C1 P-08 B1 C-08 C1
B1 J-08 D0 A-08 B0
D2 J-05
E0 D2
F-14 B0 M-14 C1 G-02 C0 G-01 B2 H-12 C0 N-03 C1 H-02 C0 C-03 B2 K-08 C0 J-01 C1 J-02 B0 D-14 D2
E0 D1
C-12 C1 E-11 D2 E-09 B2 J-03 C0 R-09 B1 H-09 C0 A-09 B2 G-03 D2 J-11 C1 K-10 D1
D0 P-05 D2
C1
C1 P-09 D0 H-01 C1
C1
D2 N-05 D0 B-05 C1
M-04 D2 L-13 D1 D-13 C1 K-04 B0 B-04 B0 G-09 B0 P-04 C1 F-04 D1 M-13 D2 E-13 C1 D-04 D0
D2
B0 F-01
FA Type No of FAs
Trang 15FA ID Previous Cycle Location
180°
270°90°
DS E2
K-14 E0 J-15 D2
C1
D2 D-13 E0 G-15 E2
E2 F-08 E2
C0 G-05 E2 F-04 D0 M-14 C0 G-07 D0 D-14 E2 K-04 C0
E2 B-10 E2 K-06
F1 E0
R-09 C0
E0
D2 N-12 E2 D-06 D2
E0 B-11
D0 D-08 B1 H-03 D0
D2 R-08 C0 J-07 C1
E2 P-08
E0 B-05
F1 E0
R-07 C0
E2 F-10 E2
C0 G-11 E2 F-12 D0 M-02 C0 J-09 D0 D-02 E2 K-12 C0
E2 B-06 E2 K-08
DS E2
K-02 E0 J-01 D2
C1
D2 D-03 E0 G-01 E2
E2
E0 E-02
FA Type No of FAs
Trang 16FA ID Previous Cycle Location
180°
270°90°
M-12 F0 A-09 E0 F-01 F2
E2
F2 L-09 E0 K-01 E0 R-09 F2 D-12 F1
P-11 F0
E2 D-02 F1 F-02 F2 G-03 F2 H-02 F2 J-03 F1 K-02 E2
F0 G-01 F1 B-11
G0 E0
A-06 E2
F2
F2 J-05 F1 B-06 E2 K-04 E1 J-09 E0
E0 L-03 E1 G-09 E2 F-04 F1 P-06 F2
F2 K-06
E2 R-08 B1 N-08 E2
E2 D-13 F2 P-08 E2
F2 K-08
E0 L-13 E1 G-07 E2 F-12 F1 P-10 F2
F2 L-11
G0 E0
A-10 E2
F1 P-05 F0
E2 D-14 F1 F-14 F2 G-13 F2 H-14 F2 J-13 F1 K-14 E2
F0 G-15 F1 B-05 F2
M-04 F0 A-07 E0 F-15 F2
E2
F2 L-07 E0 K-15 F0 R-07 F2 D-04 F1
F2
F2 K-10
FA Type No of FAs
Trang 17FA ID Previous Cycle Location
180°
270°90°
H0 G0
J-15 G2 C-09 G2
F2
G2 J-05 G2 N-09 G0
G2 L-11 G0
F2 K-13 G0 B-11 F1 B-12 G2 F-08 F1 P-12 G0 P-11 F2
G0 A-09 G2 D-12
H0 G2
J-03 F2
G1
G2 E-07 G0 L-02 F1
G1 B-10
G2 P-08 B1 H-13 G2
E2 E-10 G2 H-06 F2
DS G-09
G1 B-06
H0 G2
J-13 F2
G2 M-04 G0
F2 K-03 G0 B-05 F1 B-04 G2 K-08 F1 P-04 G0 P-05 F2
G0 A-07 G2 E-05
H0 G0
J-01 G2 C-07 G2
F2
G2 J-11 G2 N-07 G0
DS
G1 F-02
FA Type No of FAs
Trang 18FA ID Previous Cycle Location
180°
270°90°
J0 H0
E-02 H0 J-15 H1
H2
H1 K-02 H0 G-15 H0
G2 H-09 H0
H2 J-13 H2 E-09 G0 K-12 H0 C-03 G0 F-12 H2 L-09 H2
H0 P-05 G2 D-08
J0 H0
R-09 H2
G0
H1 B-06 H2 J-05 G2 B-04 H2 D-04 G2
G2 L-03 H2 M-04 G2 P-04 H2 G-05 H1
G0 C-12
H1 F-08 G2 C-06 H1
H2 K-06 H0 N-03 H2
H2 E-11
G2 L-13 H2 M-12 G2 P-12 H2 G-11 H1
G0 C-04
J0 H0
R-07 H2
G2 M-08 H0
H2 J-03 H2 E-07 G0 K-04 H0 N-13 G0 F-04 H2 L-07 H2
H0 P-11 G2 H-07
J0 H0
E-14 H0 J-01 H1
H2
H1 K-14 H0 G-01 H0
H2
G0 D-03
FA Type No of FAs
Trang 19FA ID Previous Cycle Location
180°
270°90°
H2 F-04 J0 J-15 H2 H-13 J0 G-15 H2 K-04 H1
J2
H1 F-13 H2
J2 L-11 J0 B-11 F2
F2 G-12 J0 P-11 J2
H2 K-06 H1
H0
J2 G-03 H2 H-15 J2
H0
H1 C-10
K0 J2
D-04 H0 E-13 F2 H-04 J1 E-09 J1 K-14 J2 H-14 J1 F-14 J1 L-09 F2 M-08 H0 L-13 J2
F2 M-09 J2 C-07 J1 P-10 C1 D-07 J0 N-13 J1 G-07 J0 C-13 C1 M-07 J1 B-10 J2 N-07 F2
J0 A-09 H2
N-08 J2
H2 R-08 J2
J1 G-09 D2 E-05 J1
J2 B-08 H2
J2 F-08 H2 C-08 J0
F2 M-07 J2 C-09 J1 P-06 C1 D-09 J0 N-03 J1 J-09 J0 C-03 C1 M-09 J1 B-06 J2 N-09 F2
J0 A-07 H2
K0 J2
L-05 H0 E-03 F2 D-08 J1 E-07 J1 K-02 J2 H-02 J1 F-02 J1 L-07 F2 H-12 H0 L-03 J2
H0
H1 C-06 H2
J2 D-12 J0 B-05 F2
F2 G-04 J0 P-05 J2
H2 K-10 H1
J2
H1 F-03 H2
F-12 J0 J-01 H2 H-03 J0 G-01 H2 K-12
FA Type No of FAs
Trang 20Select restart file and fuels
- Select cycle 2, 4, and 6 for cycle 7
Trang 21Just after install ‐ End of cycle 6
button controls drag and drop FA information rotate button
Core information
Trang 22Press “Fix Core” then “Single Run” for quick check
Drag and drop between “Core” and “NEWFUEL” or “REFUEL”
• keep Checker board pattern
• keep Octant symmetry
Checker board pattern
- better for lowering peak power
Fxy
Fxy
Trang 23 copy New_cy7_USERDATA files to USERDATA directory.
Trang 24click “Cycle depletion until “Completed”
click “Result View”
Trang 25Letdown curve
Trang 26click “Reactivity Calculation”
- take long time !
Trang 27select a starting point (by EFPD) MAS_RST.YG3Q_0210.00
efpd
Trang 28Quick check if xenon oscillation is stable by sudden control rod movement
Trang 29find strategy to maneuver power level by controlling
- control rod movement with automatic boron ppm, or
- control boron pppm with automatic control rod
- fully withdrawn position is 381 cm.
when it is impossible to withdraw Execution stops !
- begin with boron search for accurate initialization
Practice :
Find 0(100%) - 3 (50%) – 6 (50%) - 3 (100%) cycle
use boron search first to make accurate equillibrium
Trang 30PDIL : power dependent insertion limit (to limit consequence of rod ejection accident) AO(axial offset) limit : to limit consequence of DNB, LOCA
Boron search only
Too large axial offset
at full power
Trang 31Control rod position search only
PDIL violation Insertion limit
turn to ppm search until 75% power
Too large axial offset
at full power
* practice : use ppm search and rod position search to keep limits
Trang 32e-CORSIM is convenient tool for training Nuclear Design
- set up Loading pattern
- compute Feedback coefficients
- check Xenon oscillation
- simulate Load Following