POWER INJECTOR PARAMETERS VOLUME OF CONTRAST-ml RATE ml/sec TIME OF INJECTION – sec SCAN DELAY TIME - sec... CONTRAST ADMINISTRATION AND SCANNING METHODS• BOLUS TRACKING • BOLUS TIMING •
Trang 1CT ANGIOGRAPHY
Trang 2CT IMAGE OF THE BLOOD
VESSEL OPACIFIED BY
CONTRAST
Trang 3REQUIREMENTS FOR CTA
Trang 4PATIENT PREP.
Trang 5INFORMED CONSENT
Trang 6
PATIENT PREP.
• BUN 7-20 mg/dl
• CREAT.- 0.6 –1.2 mg/dl
• IODINE ALLERGY- STEROID THERAPY
• HYPERVENTILATION BEFORE EXAM FOR BETTER BREATHOLD
Trang 9UTILIZED
Trang 10GAUGE SUITABLE FOR CTA
18 OR 20
Trang 11CONTRAST ADMINISTERED
WITH POWER INJECTOR
Trang 21ACQUSITION PARAMETERS
Trang 22• USUALLY ROUTINE CT PRECEDES A CTA EXAM THE ROUTINE EXAM IS USED AS A REFERENCE SCAN
HELPING TO DETERMING THE
SCANNING RANGE IN CTA
Trang 23SLICE THICKNESS
• SLICE
THICKNESS
• SPATIAL RESOLUTION
Trang 25SPIRAL PITCH
RESOLUTION
Trang 26SPIRAL PITCH
• UP TO 2
Trang 27kVp, mA, TIME
• SIMILAR TO NON- CTA EXAM OF THE SAME BODY PART
Trang 28RECONSTRUCTION
INTERVAL
• 50% OF OVERLAP
Trang 30CONTRAST ADMINISTRATION
Trang 31POWER INJECTOR
Trang 32POWER INJECTOR
PARAMETERS
VOLUME OF CONTRAST-ml
RATE ml/sec TIME OF INJECTION – sec
SCAN DELAY TIME - sec
Trang 33CONTRAST WARMER
WHY???
Trang 34RATE OF INJECTION
3-5 ml/sec
Trang 35ORAL CONTRAST????
WATER NEGATIVE CONTRAST
Trang 37CONTRAST ADMINISTRATION AND SCANNING METHODS
• BOLUS TRACKING
• BOLUS TIMING
• MANUAL PRESET TIME
Trang 38CARE BOLUS
Trang 39
SMART PREP
Trang 40
SURE START
Trang 41Bolus tracking- PE
Trang 42PE?
Trang 43Tracking slice
Trang 44Bolus tracking- Carotids and
Circle of Willis
Trang 46Circle of Willis
Trang 47Circle of Willis?!
40 SEC
Trang 48Renal arteries 25-30 sec.
Trang 50ABDOMINAL AND FEMORAL RUNOFF
Trang 52CARDIAC CT
Trang 53TWO TECHNIQUES TO REDUCE MOTION ARTIFACTS IN CARDIAC
CT
• PROSPECTIVE TRIGGERING
• RETROSPECTIVE GATING
Trang 54Prospectively ECG-Triggered Sequential
Scanning
Cardiac CT applications require the
synchronization of data acquisition to the cardiac cycle, i.e to the movement of the heart For
sequential imaging, a prospective trigger is
derived from the ECG-trace to initiate the CT-scan with a certain delay time after the R-wave The
true delay time is calculated from a given phase parameter (e.g a percentage of the RR-interval time) for each cardiac cycle individually based on
a prospective estimation of the RR-intervals
Usually, the delay is defined such that the scans are acquired during the diastolic phase of the
heart
Trang 55Retrospectively ECG-Gated Spiral Scanning
For "retrospectively ECG-gated spiral scanning" a continuous spiral scan is acquired with the ECG-
signal recorded simultaneously The acquired scan data is selected for image reconstruction with
respect to a pre-defined cardiac phase Similar to ECG-triggered sequential scanning a certain R-wave delay time defines the start point of data that is
used for image reconstruction ECG-gated spiral
scanning has several advantages over
ECG-triggered sequential scanning The continuous
acquisition allows for reconstruction of overlapping slices Due to the retrospective analysis of the ECG, the technique is less sensitive to arrhythmia.
Trang 56BOTH METHODS REQUIRE
ECG MONITORING
DIASTOLIC PHASE
Trang 57SCANNING DURING
RR INTERVAL
Trang 58Retrospective ECG-Gating
Trang 59
CARDIAC CT PROCEDURES
• CARDIAC ANGIOGRAM
• CALCIUM SCORING
Trang 61CALCIUM SCORING
NO IV CONTRAST USED
Trang 62CARDIAC ANGIOGRAM
Trang 63CALCIUM SCORING
Trang 65CARDIAC ANGIOGRAM
Trang 66CTA - MPR
PLANE?
Trang 67PLANE?
Trang 68MIP - CTA
Trang 69
SSD -CTA
Trang 70VR - CTA
Trang 71CINE CTA
Trang 73• INACCURATE
Trang 74• EDITING REQUIRED
Trang 76STEREOSCOPIC VIEWING