F REQUENTLY ASKED QUESTIONS

What is Jumper Cable?

Jumper cable is the same as 4

pair solid conductor building

cable This means that its

transmission performance is

the same as regular

horizontal cable

With jumpered connections you only use as much

wire as you need Therefore, a jumpered

transmission path will always be shorter than a

patched path A jumpered solution also has lower

loss and lower crosstalk as well as a neater

appearance

What is Patch-By-Exception?

This is a product feature of HIGHBAND 8,

HIGHBAND 10, HIGHBAND 25 and Ultim8 that

allows the normal cross connect configuration to be

wired up using jumper cable When a change in

configuration is required the new connection can

simply be made by plugging a HIGHBAND patch

cord into the module This instantly sets up the new

configuration by overriding the jumpered

connection Some of the advantages of

Patch-By-Exception with HIGHBAND are:

- Lower cost due to the economy of using jumper

cable instead of patch cords

- Any temporary patches are easily seen by the

network administrator increasing control and

record accuracy

- The normal connection configuration can be

restored simply by removing the patch cord

- Neat and tidy cable management due to

elimination of patch cord slack Lower

transmission loss

- Easy removal of jumpered patches (no plug or

locking tab to snare on other patches)

- Eliminates potential user damage to modular

patching such as bent patch panel pins, cord

fracture or failure due to tightness or tangle, and

plug locking tab breakage

- If temporary patches are to become permanent,

they can be replaced by jumper cross connections

when convenient The removed patch cords can

be kept handy for future use

Does HIGHBAND have a disconnect test facility?

Yes The HIGHBAND 8, HIGHBAND 10, HIGHBAND 25, Ultim8 and Compact 8 modules use a disconnect contact allowing test access to a circuit without breaking the circuit or removing wires You can also leave

jumpers in place and patch the same circuit to another port (i.e

Patch-By-Exception)

Why use HIGHBAND instead

of RJ45 patch panels?

There are many reasons why you would choose

HIGHBAND over RJ45 patching Refer to the technology comparison HIGHBAND vs RJ, document under the HIGHBAND tech-tips area on this CD-ROM

What advantages does HIGHBAND provide that a 110 system w ill not?

There are many Refer to the technology comparison HIGHBAND vs 110 Type, document under the HIGHBAND tech-tips area on this CD-ROM

Does my standard KRONE tool terminate

w ires on HIGHBAND?

Yes HIGHBAND has been designed to be compatible for use with the existing KRONE Termination Tools

Why use HIGHBAND 16 and 20 M odules?

When high density patching is considered more important than the disconnect or jumpering facility, HIGHBAND 16 and 20 modules may be more appropriate than HIGHBAND 8, 10 and 25 pair modules