Einzelader AWG 23/1 Aderisolation Paarschirm Gesamtschirm Außenmantel Application: n Installation cable within structured cabling systems acc.. to EN 50173 n To be used in pathway system
Trang 1Einzelader AWG 23/1 Aderisolation Paarschirm Gesamtschirm Außenmantel
Application:
n Installation cable within
structured cabling systems
acc to EN 50173
n To be used in pathway
systems
Possible Sevices:
n Ethernet 10 BaseT,
n Fast Ethernet 100 Base T,
n Gigabit Ethernet 1000
Base T
n ATM 155 Mbit/s
n TP-PMD 125 Mbit/s
n Cable sharing (same or
different sevices)
n CDDI/TPDDI (FDDI on
copper)
n Token Ring with 4/16
Mbit/s
n Analogue Telephony, ISDN
Profile view:
KRONE
Category 6 Installation Cable S-STP, LSZH
Einzelader AWG 23/1 Aderisolation Paarschirm Gesamtschirm Außenmantel
Copper wire AWG 23/1 core insulation Aluminium foil copper braid outer jacket
KRONE GmbH Beeskowdamm 3-11 Germany - 14167 Berlin Phone: +49 30 8453-1422 Fax: +49 30 8453-1412
http://www.krone.com
e-mail: vertrieb@krone.com
Trang 2Conductor bare copper wire AWG 23/1 (0,57 mm)
PE-insulation with approx 0,4 mm wall
Thickness, Core approx 1,4 mm
Lay up 4 x 2 cores paired
Core colours: wh/bu, wh/og, wh/gn,
wh/bn pair in metal foil Overall shielding Tinned copper braid
Outer jacket Halogen-free and flame retardant
Material (LSFRZH),
Colour: orange RAL 2003
Outer diameter: approx 7,5 mm
Inkjet marking, black:
KRONE PREMISNET CAT6 S-STP LSZH FR
4P AWG23 SBC 3P VERIFIED ISO/IEC 11801/ EN50173/IEC 60332-3
CAT C <week/year> LA <KRONE
70532062> <METERMARKER>
Standardisation:
n According to EN50167, EN 50173, ISO/IEC 11801 and
prEN 50288-5-1 (edition January 2001)
n According to European Guideline 73/23/EWG
(CE-marking)
n 3 P (Third Party Testing) verified, Copenhagen, DK
Mechanical Characteristics:
n Bendradius
During installation 8 x O.D
Installed 4 x O.D
n Weight ca 66 kg/km
n Tensile strength 360N
Thermal characteristcs:
Transport and storage -20°C up to + 60°C Installation 0°C up to + 50°C Operation -20°C up to + 60°C
Chemical Characteristics:
n Oil, fuel no
n Acid, leach gering
n Organic solvents yes
Fire Performance:
Flame retardent ISO 60332-1, 60332-3 Kat.C Smoke density IEC 61034-1, 61034-2 Halogen-free IEC 60754-2
Propagation of fire no Fire load 670 kJ/m (0,19 kwh/m)
Electrical Characteristics:
DC loop resistance typ 158 Ohm/km Resistance unbalance max 2 % Mutual capacity 45 pF/m Nominal velocity of
Propagation NVP-Wert) Impedance 100 +/- 15 Ohm
Screening attenuation up to 1000MHz min 60dB Transfer impedance at 10MHz nom 5mOhm/m Attenuation and NEXT see table
Cat.6 Installation Cable S-STP, LSZH, orange, round, spool 1000m 7053 2 062-25
Frequenz [MHz] 1 4 10 16 20 31,25 62,5 100 155 200 250 300
attenuation [dB/100m] 1,9 3,6 5,7 7,2 8,1 10,1 14,4 18,3 23,1 26,2 29,3 32,3
Next [dB] 90,0 90,0 90,0 90,0 90,0 90,0 83,0 77,7 72,1 68,9 65,8 63,2
ACR [dB] 88,1 86,4 84,3 82,8 81,9 79,9 68,6 59,4 49,0 42,7 36,5 30,9
EL FEXT [dB] 90,0 90,0 90,0 90,0 90,0 87,0 84,0 73,0 76,0 68,0 66,0 63,0
RL [dB] 30,0 30,0 30,0 30,0 28,0 26,0 25,0 24,0 22,0 20,0 20,0 18,0
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
9 0
1 0 0
f r e q u e n c y [M H z ] at t enuat ion [dB/1 0 0 m ] N e x t [ d B ]