You must read this Manual when installing the Exaopc OPC Interface Package.Pack-This Manual consists of the following chapters: • Chapter 1 Installation Procedure Overview This chapter d
Trang 1NTPF100 Exaopc OPC Interface Package Installation Manual
IM 36J02A12-01E
IM 36J02A12-01E
23rd Edition
Trang 2This Installation Manual describes how to install and set up the Exaopc OPC Interface age You must read this Manual when installing the Exaopc OPC Interface Package.
Pack-This Manual consists of the following chapters:
• Chapter 1 Installation Procedure Overview
This chapter describes the overall installation procedure of the Exaopc OPC InterfacePackage
• Chapter 2 Hardware Setup
This chapter describes DIP Switch setup to be finished before Software installation
• Chapter 3 Requirements for Installation
This chapter describes requirements and setup items to be checked before Exaopc stallation such as required environment
in-• Chapter 4 Initially Installing Exaopc
This chapter describes the Windows setup, control bus driver installation and Exaopc stallation procedure
in-• Chapter 5 Connecting to CENTUM system
This chapter describes the setup procedure to be required to connect to CENTUM tem
sys-• Chapter 6 Configuring Exaopc Client Computer
This chapter describes how to configure an Exaopc client computer connected to anExaopc server computer(s) via a network
• Chapter 7 Reinstallation or Upgrade
This chapter describes the procedures and precautions for reinstalling or upgradingExaopc
• Chapter 8 Installation and Setup of OPC Server Redundancy Function (Exaopc-RD)This chapter describes the installation procedure and the setup procedure to configureOPC server redundancy functionality
• Chapter 9 IT Security Settings
This chapter describes details of security models of IT security settings and how to use ITSecurity Setting Tool
• Chapter 10 Setting the Exaopc Product Security function
• Chapter 11 Important Information on Operating Exaopc
This chapter describes important information on the operation of Exaopc
• Chapter 12 Troubleshooting
This chapter describes possible causes of problems and their solutions
• Chapter 13 Online Manual
This chapter describes the online manual installation procedure and how to use it
• Appendix 1 Combine Exaopc and Other Products
Trang 3Safety Precautions for Use
• To protect the system controlled by the Product and the Product itself and to ensure safeoperation, please observe the safety precautions described in this Manual YokogawaElectric Corporation ("YOKOGAWA") assumes no liability for safety if users fail to observethe safety precautions and instructions when operating the Product
• If the Product is used in a manner not specified in the User's Manuals, the protection vided by the Product may be impaired
pro-• If any protection or safety circuit is required for the system controlled by the Product or forthe Product itself, please install it externally
• Be sure to confirm the specifications and required settings of the devices that are used incombination with the Product by referring to the instruction manual or other documents ofthe devices
• Use only spare parts that are approved by YOKOGAWA when replacing parts or ables of the Product
consum-• Do not use the Product and its accessories such as power cords on devices that are notapproved by YOKOGAWA Do not use the Product and its accessories for any purposeother than those intended by YOKOGAWA
• Modification of the Product is strictly prohibited
• The following symbols are used in the Product and User's Manuals to indicate the panying safety precautions:
accom-Indicates that caution is required for operation This symbol is labeled on the uct to refer the user to the User's Manuals for necessary actions or behaviors inorder to protect the operator and the equipment against dangers such as electricshock In the User's Manuals, you will find the precautions necessary to preventphysical injury or death, which may be caused by accidents, such as electric shockresulting from operational mistakes
Prod-<French> Signale qu'il faut faire preuve de prudence pendant le fonctionnement
Ce symbole, apposé sur le produit, demande à l'opérateur de se reporter aux manuels de l'utilisateur pour savoir les actions ou comportements nécessaires afin de protéger l'équipement ou l'opérateur contre les dangers tels qu'une élec-trocution Les manuels de l'utilisateur présentent les précautions nécessaires afin d'éviter des blessures corporelles ou la mort, qui peuvent être causées par des accidents tels qu'une électrocution suite à une erreur de fonctionnement
Indicates that caution is required for hot surface Note that the devices with thissymbol become hot The risk of burn injury or some damages exists if the devicesare touched or contacted
<French> Signale qu'il faut faire preuve de prudence avec la surface brûlante Les appareils sur lesquels est apposé ce symbole risquent de devenir brûlants Tout contact physique ou matériel avec ces appareils risque de provoquer des brûlures
Indicates an AC supply
Indicates a DC supply
Trang 4Indicates the OFF position of a power on/off switch.
• Hand over the User's Manuals to your end users so that they can keep the User's uals on hand for convenient reference
Man-• Thoroughly read and understand the information in the User's Manuals before using theProduct
• For the avoidance of doubt, the purpose of the User's Manuals is not to warrant that theProduct is suitable for any particular purpose but to describe the functional details of theProduct
• Contents of the User's Manuals are subject to change without notice
• Every effort has been made to ensure the accuracy of contents in the User's Manuals.However, should you have any questions or find any errors, contact us or your local dis-tributor The User's Manuals with unordered or missing pages will be replaced
• Except as specified in the warranty terms, YOKOGAWA shall not provide any warranty forthe Product
• YOKOGAWA shall not be liable for any indirect or consequential loss incurred by eitherusing or not being able to use the Product
• YOKOGAWA makes no warranties, either expressed or implied, with respect to the ware Product's merchantability or suitability for any particular purpose, except as speci-fied in the warranty terms
Soft-• Purchase the appropriate number of licenses of the Software Product according to thenumber of computers to be used
• No copy of the Software Product may be made for any purpose other than backup; wise, it is deemed as an infringement of YOKOGAWA's Intellectual Property rights
other-• Keep the software medium of the Software Product in a safe place
• No reverse engineering, reverse compiling, reverse assembling, or converting the ware Product to human-readable format may be performed for the Software Product
Soft-• No part of the Software Product may be transferred, converted, or sublet for use by anythird-party, without prior written consent from YOKOGAWA
Trang 5Documentation Conventions
The following symbols are used in the User's Manuals
WARNING Indicates precautions to avoid a danger that may lead to death orsevere injury
CAUTION Indicates precautions to avoid a danger that may lead to minor ormoderate injury or property damage
IMPORTANT Indicates important information required to understand operations or
functions
Indicates additional information
Indicates referenced content
In online manuals, you can view the referenced content by clickingthe links that are in green text However, this action does not apply
to the links that are in black text
The following typographical conventions are used throughout the User's Manuals
• Δ Mark
Indicates that a space must be entered between character strings
Example:
.ALΔPIC010Δ-SC
• Character string enclosed by braces { }
Indicates character strings that may be omitted
Example:
.PRΔTAG{Δ.sheet name}
• Characters enclosed by brackets [ ]
When characters are enclosed by brackets in the description of a key or button operation,
it indicates a key on the keyboard, a button name in a window, or an item in a list boxdisplayed in a window
Example:
To alter the function, press the [ESC] key
The following conventions are used within a command syntax or program statement format:
• Characters enclosed by angle brackets < >
Indicate character strings that user can specify freely according to certain guidelines
Trang 6#define <Identifier> <Character string>
• " "
Indicates previous command or argument that may be repeated
Example:
Imax (arg1, arg2, )
• Characters enclosed by brackets [ ]
Indicate character strings that may be omitted
Example:
sysalarm <format character string> [, <output value>…]
• Characters enclosed by separators | |
Indicates character strings that can be selected from more than one option
Example:
opeguide <format character string> [, <output value> ]
OG, <element number>
Trang 7set-Copyright and Trademark Notices
The copyright of the programs and online manuals contained in the software medium of theSoftware Product shall remain with YOKOGAWA
You are allowed to print the required pages of the online manuals for the purposes of using oroperating the Product; however, reprinting or reproducing the entire document is strictly pro-hibited by the Copyright Law
Except as stated above, no part of the online manuals may be reproduced, transferred, sold,
or distributed to a third party in any manner (either in electronic or written form including, out limitation, in the forms of paper documents, electronic media, and transmission via thenetwork) Nor it may be registered or recorded in the media such as films without permission
ei-• Adobe, Acrobat, and Reader are either registered trademarks or trademarks of AdobeSystems Incorporated in the United States and/or other countries
• All other company and product names mentioned in the User’s Manuals are trademarks
or registered trademarks of their respective companies
• We do not use TM or ® mark to indicate those trademarks or registered trademarks in theUser’s Manuals
• We do not use logos in the User’s Manuals
Trang 8NTPF100 Exaopc OPC Interface Package Installation Manual
3 Requirements for Installation 3-1
4 Initially Installing Exaopc 4-1
4.1 Windows Setup Items 4-3
4.1.1 Information Required for Setup 4-44.1.2 Setting Items when Installing Windows 4-64.1.3 Security Model 4-74.1.4 Product Security 4-84.1.5 Precautions for Installing Windows Operating System 4-9
4.2 Setting Up Windows 4-10
4.2.1 Configuring on Windows 10 4-114.2.2 Configuring on Windows 7 4-164.2.3 Configuring on Windows Server 2008 R2 4-25
4.3 Setting Network 4-32
4.3.1 Procedure 1 Setting Network 4-334.3.2 Procedure 2 Setting Control Bus Driver 4-344.3.3 Procedure 3 Setting the Vnet/IP Open Communication Driver
4-384.3.4 Procedure 4 Configuring Windows Network Settings 4-414.3.5 Procedure 5 Set IP Addresses 4-474.3.6 Procedure 6 Set Bindings 4-534.3.7 Procedure 7 Change Computer Name 4-554.3.8 Procedure 8 Confirming that the Driver has been Installed Properly
4-57
4.4 Exaopc Installation Procedure 4-63 4.5 Configuring Windows Environment Settings for Each User 4-75
4.5.1 Configuring on Windows 7 4-764.5.2 Configuring on Windows Server 2008 R2 4-78
Trang 94.7 Exaopc Process Execution Account 4-82 4.8 Microsoft Windows Hotfix 4-83
5 Connecting to CENTUM System 5-1
5.1 Settings Required for Connecting to CENTUM VP/CENTUM CS 3000
System 5-2 5.2 Settings Required for Connecting to a CENTUM CS System 5-9
6 Configuring Exaopc Client Computer 6-1
6.1 Exaopc Client Setup 6-2 6.2 Setting Up Windows (Windows 7/Windows Server 2008 R2) 6-11
6.2.1 Procedures Common to All Security Models 6-126.2.2 Setup Procedure for Legacy model 6-146.2.3 Setup Procedure for Standard model 6-26
6.3 Setting Up Windows (Windows 8.1/Windows Server 2012/Windows
Server 2012 R2) 6-30 6.4 Setting Up Windows (Windows 10) 6-31
7 Reinstallation or Upgrade 7-1
7.1 Updating or Deleting Control Bus Driver 7-2
7.1.1 TCP/IP Inconsistency Detect Tool 7-107.1.2 TCP/IP Inconsistency Repair Tool 7-12
7.2 Reinstalling or Upgrading Exaopc 7-15
8 Installation and Setup of OPC Server Redundancy Function
(Exaopc-RD) 8-1
8.1 Installing Exaopc-RD on Client Computer 8-3
8.1.1 Preparations before Installation 8-48.1.2 Exaopc-RD Installation Procedure 8-7
8.2 Installing Exaopc-RD (HDA equalization module) on Exaopc 8-18 8.3 Setting Up Exaopc-RD on Client Computer 8-20 8.4 Setting Up Exaopc-RD (HDA equalization module) on Exaopc 8-23 8.5 Setting Up the Windows Network 8-24 8.6 Exaopc-RD Version Upgrading Procedure 8-26
8.6.1 Exaopc-RD Version Upgrading Procedure on Client Computer
8-278.6.2 Exaopc-RD (HDA equalization module) Version Upgrading
Procedure on Exaopc 8-28
9 IT Security Setting 9-1
9.1 Security Models can be Selected when Installing Exaopc 9-2 9.2 Cautions when Selecting “Standard Model” 9-3 9.3 Security Configuration Items 9-5
10 Setting the Exaopc Product Security function 10-1
10.1 Selection of logon method 10-2
10.1.1 Initial setting values 10-310.1.2 Selecting procedure of logon method (Exaopc) 10-410.1.3 Selecting procedure of logon method (Exaopc-RD) 10-6
Trang 1010.2.1 Logon user registration procedure (Exaopc) 10-810.2.2 Logon user registration procedure (Exaopc-RD) 10-10
11 Important Information on Operating Exaopc 11-1
11.1 Procedure to Use If You Cannot Set the Computer Name to Match the
Station Name 11-2 11.2 Application Program Execution Environment 11-3 11.3 Important Information for Reinstalling Exaopc or Doing Additional
Exaopc Installations 11-4 11.4 License Protection 11-5 11.5 Important Information for Using Uninterruptible Power Supply (UPS)
Software 11-6 11.6 Using the Utilities 11-7 11.7 Collecting and Storing Large Quantity of Data at High Speed 11-8 11.8 Connection with a CENTUM CS which has an Enet and Ethernet
Communication 11-9 11.9 Replacing the Card for Control Bus 11-10 11.10 Exaopc Applications That Can Be Called Up from the Start Menu 11-11 11.11 Precautions for using Windows 10 11-12
12 Troubleshooting 12-1
13 Online Manual 13-1
Trang 11NTPF100 Exaopc OPC Interface Package Installation Manual
Trang 12This chapter describes preparations for installing the Exaopc OPC Interface Package, and theoverall flow of the installation procedure.
In this Manual, all the OPC server functions (Product codes: NTPF100-S1, NTPF100-S3,NTPF100-S6, NTPF100-SB) are collectively referred to as “Exaopc (NTPF100)”, and the OPCserver redundancy function (Product code: NTPF100-SX) is referred to as “Exaopc-RD
(NTPF100-SX)”
Furthermore, Exaopc (NTPF100) may be abbreviated as “Exaopc” and Exaopc-RD
(NTPF100-SX) as “Exaopc-RD” unless there is possibility of misunderstanding
Perform the installation procedures and setups in the following chapters corresponding to theProduct code
Chapter 2 Hardware Setup
Chapter 3 Requirements for Installation
Chapter 4 Initially Installing Exaopc
Chapter 5 Connecting to CENTUM system
Chapter 6 Configuring Exaopc Client Computer
Chapter 9 IT Security Settings
Chapter 10 Setting the Exaopc Product Security function
Refer to the following Chapters as necessary:
Chapter 7 Reinstallation or Upgrade
Chapter 11 Important Information on Operating Exaopc
Chapter 12 Troubleshooting
Chapter 13 Online Manual
Chapter 8 Installation and Setup of OPC Server Redundancy Function (Exaopc-RD)
Installation procedure flow is shown below
Trang 13End
(1) Determine system configuration.
(3) Install Windows (Chapter 4)
(4) Install the Windows network functions
(Chapter 4)
(5) Install Exaopc (Chapter 4)
(7) Configure Exaopc Client Computer (Chapter 6)
(6) Connect to the CENTUM system (Chapter 5)
(2) Hardware Setup (Chapter 2)
Scope of this Manual
• Determine the control bus address for Exaopc station (For CS cassettes only)
• Determine the computer name of Exaopc station.
• Determine the security model.
• Set up the control bus Interface card (VF702/VF701) or the Vnet/IP interface card (VI702/VI701)
• Check the Ethernet card.
• Requirements before Installation (Chapter 3).
• Install Windows.
• Set the computer name.
• Install Service Pack.
• Install the Ethernet adapter and TCP/IP.
• Install the control bus driver.
(For CS cassettes only)
• Configure the Windows network settings.
• Install Exaopc
• IT Security Setting (Chapter 9).
• Exaopc Product Security function (Chapter 10).
• Configure the settings for connecting to the CENTUM system.
• Configure a client computer(s) connected to an Exaopc server(s) via a network.
• Configure Windows security settings.
(8) OPC server verification • Verify with the tool that the Exaopc OPC server has started itself properly.
Figure 1-1 Installation procedure flow chart
In this Manual, a computer with the Exaopc OPC Interface Package installed is referred to as
“Exaopc station.” Also note that Windows OS version may be abbreviated as “Windows.”
IMPORTANT
When upgrading software, confirm release note issued separately
Follow these steps to install Exaopc and configure the settings
l Determining system configuration
• Determine the system configuration If you are using an Exaopc CS series cassette(*1),determine the control bus address of an Exaopc station
• Determine the computer name of an Exaopc station The computer name is the same asthe station name “STNddss” (dd: domain number; ss: station number)
• Exaopc offers security models as IT security correspondence When installing Exaopc,work corresponding to the security model is required Please decide the security model
in advance
*1: In this Manual, the Exaopc cassettes for connecting to CENTUM VP, CENTUM CS 3000, or CENTUM CS are collectively referred to as “CS series cassette“ or “CS cassettes.”
Trang 14Exaopc Security Guide (IM 36J02A01-01E)
l Hardware Setup
• Set up the DIP switch on the control bus Interface card (VF702/VF701) or the Vnet/I terface card (VI702/VI701) and check the Ethernet card
Pin-SEE
ALSO For more information about hardware setup, refer to:
2., “Hardware Setup” on page 2-1
l Installing Windows
• Check whether your computer meets the hardware and software requirements for
Exaopc
• Install Windows Set the computer name during this process
• Also install Windows Service Pack
• Be sure to install an Ethernet adapter and TCP/IP when you install Windows
l Installing Windows network functions
• Install the control bus driver through the network control panel when using CS cassettes
• Configure setup items related to Windows Network, such as TCP/IP protocols and work bindings
net-SEE
ALSO For more information about installing Windows network functions, refer to:
• 3., “Requirements for Installation” on page 3-1
• 4., “Initially Installing Exaopc” on page 4-1
l Installing Exaopc
• Make the preparations corresponding to the selected security model
• Reboot your computer and install Exaopc
• Configure the settings after installing Exaopc
• Configure the IT Security settings for the Exaopc station
• Configure the security settings for OPC client(s) to access data via the Exaopc station
SEE
ALSO For more information about installing Exaopc, refer to:
• 4., “Initially Installing Exaopc” on page 4-1
• 10., “Setting the Exaopc Product Security function” on page 10-1
l Connecting to CENTUM system
• When Exaopc installation is completed, perform necessary operations for connecting tothe CENTUM system
SEE
ALSO For more information about necessary operations in the CENTUM system, refer to:
Trang 15l Configuring Exaopc Client Computer
• Configure an Exaopc client computer(s) connected to the Exaopc station (server er) via a network
comput-Exaopc is now ready to use
SEE
ALSO For more information about configuring Exaopc client computer, refer to:
6., “Configuring Exaopc Client Computer” on page 6-1
l OPC server verification (Exaopc R3.20 or later)
• The “OPC Connection Confirm Tool” allows easy check for whether the Exaopc OPCserver function operates properly
• Run the “OPC Connection Confirm Tool” from the Exaopc station or the Exaopc clientcomputer(s) and connect to the DA server to read sample data
SEE
ALSO For more information about “OPC Connection Confirm Tool”, refer to:
9.1, “OPC Connection Confirm Tool” in the NTPF100 Exaopc OPC Interface Package Guide Manual (IM 36J02A11-01E)
The diagram below shows where to perform each installation procedure The numbers in thediagram correspond with the numbers in the “Figure Installation procedure flow chart.”
Trang 16OPC Client Configure Exaopc Client Computer (7)
Exaopc Access Environment OPC connection confirm
Windows, Service Pack Security Setup (*4) Network Setup Windows Setup
Windows, Service Pack
Security Setup (*1)
Computers installed with the system builder function or EWS
Engineering Station
Engineering Setup Engineering Function
Control Station Group
Network Setup Windows Setup
Control Bus Driver Control Bus Card (V net or Vnet/IP) (3)
(5) (4), (5)
(4) (2) (3), (5)
OPC Server computer
Ethernet Ethernet or Enet
Control network
Exaopc station
Exaopc Setup Window (8)
(6) HIS or ICS
• OPC connection confirm (*3)
• Exaopc Server Monitor (*3) Setup Tool
• ExaopcExecAccountChange Tool (*2)
• IT Security Tool (*2)
• Exaopc Product Security
OPC Server Function
Figure 1-2 Overall View of Installation Procedure
*1: A security setup is made when Exaopc is installed
*2: Use it only when required for such as security model change
*3: This tool is used for confirmation or monitoring of Exaopc operations
*4: On client computers, configure Windows security settings according to the procedure inChapter 6
Trang 172 Hardware Setup
This Chapter describes how to setup the hardware before the Exaopc installation It is sary to set domain and station numbers for the following switches before installing the soft-ware:
neces-• Control Bus interface card (VF702/VF701): for CENTUM VP, CENTUM CS 3000,
CENTUM CS
• Vnet/IP interface card (VI702/VI701): for CENTUM VP, CENTUM CS 3000
TIP Specifically, before installation, be sure that the control bus interface card for the PC is correctly set When
the domain number and station number are correctly defined and a Control Bus is properly connected, the SND and RCV lamps turn on at power-on.
If the RCV lamp turns on while the SND lamp does not, check the dip switch setting of the corresponding card.
Before installing software, reconfirm that these settings are correct
Check that the Ethernet card are properly installed in a PC
• During maintenance work use a wrist strap with a ground wire via a grounding resistance
of 1 M ohm Be sure to ground the wrist strap
• When performing maintenance work on a desk or a table, place a conductivity sheetgrounded via a grounding resistance of 1 M ohm The maintenance person must wear awrist strap while performing maintenance work Take any plastic and other materials thatcan easily be charged away from the work area
• Exercise caution so as not to touch any of the maintenance parts while the wrist strapand a conductivity sheet are not being used
Trang 18The following two types of control bus interface cards are available These cards have thesame functionality.
• VF702 (for PCI Express)
• VF701 (for PCI bus)
The Control Bus interface card has DIP switches for setting the domain number and the tion number The combination of domain number and station number determines the stationaddress
sta-You must set the DIP switches before you configure network settings
This section describes how to set the DIP switches The DIP switch locations are the same onVF702 and VF701 cards
STATION
DOMAIN SW1 SW2 DOM STN
DIP switches
Station number Domain number
Figure 2.1-1 Location of DIP Switches
A domain is a collection of stations that are connected on one control bus network Set a main number from 1 to 16
do-1
0
DOMAIN NO.
MSB : Most Significant Bit
LSB : Least Significant Bit
(MSB)(LSB)
P 0 0
Domain number (5 bits) Fixed to 0 (2 bits) Parity of the domain number (1 bit) (odd parity)
1 2 3 4 5 6 7 8
Figure 2.1-2 Domain Number Setting DIP Switches
SEE
ALSO For more information about domain numbers and the corresponding DIP switch positions, refer to:
“n Domain Numbers and DIP Switch Positions” on page App.2-1
Trang 19Station number (7 bits)
MSB : Most Significant Bit
LSB : Least Significant Bit
Parity of the station number (1 bits) (odd parity)
1 2 3 4 5 6 7 8
Figure 2.1-3 Station Number Setting DIP Switches
SEE
ALSO For more information about station numbers and the corresponding DIP switch positions, refer to:
“n Station Numbers and DIP Switch Positions” on page App.2-1
• Install VF702/VF701 in the computer after setting up Windows but before configuring thenetwork settings
• Install the control bus driver when you restart the computer after installing VF702/VF701.Follow the procedure in this manual to install the driver
After you have set the station address on the VF702/VF701 card, follow these steps to install
it in the computer:
1 Turn off the power of the computer For safety, remove the power plug from the outlet
2 Remove the cover of the computer
3 Unscrew the screws fixing the slot cover and remove the slot cover
4 Insert the VF702/VF701 card in the corresponding slot and fix it to the slot
5 Mount the cover back on the computer
6 Write the station address on the label that comes with the VF702/VF701 card and paste it
in the front or other easy-to-see location of the computer
Trang 20You need to install a Vnet/IP interface card (VI702) in the computer that is to be connected on
a Vnet/IP network
The VI702 card is for PCI Express, and the VI701 card is for PCI
The Vnet/IP interface card has DIP switches for setting the domain number, station numberand action mode The combination of domain number and station number determines the sta-tion address
You must set the DIP switches properly before configuring network settings
This section describes how to set the DIP switches
DIP switches Station number Domain number
Operating mode
SW1 SW2
DOMAIN
STATION
SW4
Figure 2.2-1 Locations of the DIP Switches
A domain is a collection of stations that are connected on one control bus network Set a main number from 1 to 16
do-1
0
DOMAIN NO.
MSB : Most Significant Bit
LSB : Least Significant Bit
(MSB)(LSB)
P 0 0
Domain number (5 bits) Fixed to 0 (2 bits) Parity of the domain number (1 bit) (odd parity)
1 2 3 4 5 6 7 8
Figure 2.2-2 Domain Number Setting DIP Switches
SEE
ALSO For more information about domain numbers and the corresponding DIP switch positions, refer to:
“n Domain Numbers and DIP Switch Positions” on page App.2-1
Trang 21n Setting the Station Number
Station numbers should be set in the range of 1 to 64; it is recommended to set starting from
64 in the descending order
Station number (7 bits)
MSB : Most Significant Bit
LSB : Least Significant Bit
Parity of the station number (1 bits) (odd parity)
1 2 3 4 5 6 7 8
Figure 2.2-3 Station Number Setting DIP Switches
SEE
ALSO For more information about station numbers and the corresponding DIP switch positions, refer to:
“n Station Numbers and DIP Switch Positions” on page App.2-1
Trang 22Before installing software, reconfirm that these settings are correct Check that the Ethernetcard are properly installed in a PC.
The Ethernet is required when a network other than the Control Bus is connected
Confirm that the Ethernet card is properly inserted and connected to the network via the
prop-er cable
SEE
ALSO For more information about the setup procedure, refer to:
4.3, “Setting Network” on page 4-32
For more information about inserting card to PC, refer to:
The network adapter manual
Trang 233 Requirements for Installation
The hardware and software environment required for the operation of the Exaopc is described
in this Chapter
Be sure to confirm that the environment is properly provided before installing the software
The following items should be ready for use:
• Exaopc software medium NTPKM01 (1)
• Important Notice on License Number (IM 36J10A40-01E)
IMPORTANT
Install Exaopc-RD in a PC other than the OPC server (Exaopc) Exaopc and Exaopc-RD aresupplied with the same software medium These software installers are identified according toeach license number
SEE
ALSO For more information about OPC Server Redundancy (Exaopc-RD) installation, refer to:
8., “Installation and Setup of OPC Server Redundancy Function (Exaopc-RD)” on page 8-1
This section describes the hardware and software requirements for the OPC server (Exaopc)and the OPC server redundancy function (Exaopc-RD)
The computer (PC/AT compatible machine) requirements differ between Exaopc and
Exaopc-RD The hardware requirements for Exaopc also differ, depending on whether the function tosupport the CENTUM VP consolidated alarm management Software for HIS (hereinafter re-ferred to as CAMS for HIS) is applied
SEE
ALSO For more information about the environmental requirements for Exaopc and Exaopc-RD, refer to:
NTPF100 Exaopc OPC Interface Package (GS 36J02A10-01E)
When installing Yokogawa solution-based software packages (SBPs), install Exaopc ahead ofthese packages Yokogawa solution-based software package includes Exaquantum, Exapilot,AAASuite, Exaplog, and APC products
It is assumed that security patches are applied according to the customer’s security policy.YOKOGAWA recommends to apply security patches to Exaopc systems It is recommended
to apply all required security patches before the system goes into operation and also applysecurity patches that are released after the system went into operation as promptly as possi-ble YOKOGAWA offers security patch application services Contact YOKOGAWA Service formore information
Trang 24n Customization at Installation of Windows 10
When using Windows 10 Enterprise LTSB computers, customize the Windows settings duringinstallation of Windows 10
SEE
ALSO For more information about the customization at Installation of Windows 10 Enterprise LTSB, refer to:
Appendix 3., “Customization at Installation of Windows 10” on page App.3-1
Trang 254 Initially Installing Exaopc
This chapter explains the initial installation procedure of Exaopc and various setups related tothis installation after the hardware setup
Operation
l Windows Network Setup
To properly install and operate Exaopc, it is necessary that the Windows network (more thanone adapter and TCP/IP protocol) has been installed and properly operated
Be sure to set a computer name and IP address in a PC where the network has been alreadyinstalled
ALSO For more information about setting a computer name and IP address, refer to:
4.3, “Setting Network” on page 4-32
l Installing the Service Pack
To operate Exaopc properly, it is necessary to install the service pack of Windows
If the Windows configuration is changed in a PC where the service pack has been installed,the service pack must be reinstalled
In the following cases be sure to reinstall the service pack
• After the configuration change (deletion/addition) of the TCP/IP protocol, an error red in the TCP/IP protocol service
occur-• When a configuration change such as addition of a printer or a network adapter is made,the dialog of “Some Windows files need to be copied” was displayed upon the configura-tion setup
SEE
ALSO For more information about checking which service pack of Windows is compatible with the version of Exaopc, refer to:
“n Hardware and Software Environment” on page 3-1
l Windows Virtual Memory
This virtual memory is required for stable operation of Exaopc Be sure to expand the ry
memo-SEE
ALSO For more information about virtual memory settings, refer to:
4.2, “Setting Up Windows” on page 4-10
Trang 274.1 Windows Setup Items
The setup items for Windows required after it has been installed are described in this Chapter
Trang 28The following information is required for the setup:
IMPORTANT
• When using CS cassettes make sure to match the names of a computer and a station
• Set the computer name within eight characters for the computer with Exaopc for
CENTUM VP Batch/CS Batch 3000 installed
A computer name is a name used to identify each computer on the Windows network An bitrary computer name can be specified using the Windows Control Panel
ar-A station name (for CS cassettes only) is a name uniquely and fixedly specified according tothe Control bus address in the CENTUM system
When connecting to CENTUM VP or CENTUM CS 3000, you must note the following points:
• Even if no control bus interface card is installed, installed the control bus driver before ing the Test Function
us-• If using the Expanded Test Functions, be sure not to duplicate the control bus addressthat needs to be set for each connected PC
The IP addresses set for control bus adapters should be the same control bus addressesset on System View for the PCs
Example: 172.16.dd.ss
The IP addresses for different PCs should not be identical
Note that the address can be the same as “domain number.station number” used for theHIS, but that the address should not be the same as “domain number.station number”usedf or the FCS
Set from 1 to 16 for the domain number Set from 1 to 64 for station number
Trang 29Note the following items regarding to the subnet mask:
• Use the exist setting of the current network environment when installing Exaopc in an isting network environment
ex-• Use the default value determined by the IP address when installing Exaopc in a newlyprovided local network environment (IP address: 172.17.dd.ss, subnet mask:
255.255.0.0)
When using CS cassettes, use the default IP address for the Control Bus (IP address:
172.16.dd.ss, subnet mask: 255.255.0.0)
Perform the installation tasks as the user with Windows administrator privileges The userswith administrator privileges vary depending on the setup procedure performed and its condi-tions
The administrative user accounts that can be used to perform the new installation are shown
as follows:
Table 4.1.1-1 Administrative user accounts that can be used to perform the new installation
Model and User Management Type to be Applied
Stand-alone type Domain/Combination type
Administrator of local user Administrator of local user DomainAdmins of domain user(*1)
*1: The PC should connect to the domain.
When creating an “administrative user” as a Windows user, make sure that the user belongs
to the applicable group(s) in the table The user who has performed an installation will matically belong to the EXA_MAINTENANCE group
SEE
ALSO For more information about connection to a CENTUM VP/CENTUM CS 3000 system, refer to:
5.1, “Settings Required for Connecting to CENTUM VP/CENTUM CS 3000 System” on page 5-2
Trang 30The Windows setting items regarding to network settings are explained as follows.
For a Exaopc with CS cassettes, the computer name should be the same as the stationname
The computer name can be modified after Windows installation
Choose “Typical Settings” for network settings This installs the “Client for Microsoft Network,”
“File and Printer Sharing of Microsoft Network” and “TCP/IP Transport protocol with automaticaddressing” as default even though the network adapters are not installed
Trang 314.1.3 Security Model
Select the security model to be installed The installation procedure differs for each securitymodel
When Standard Model is selected as the security model for Exaopc, work on the Exaopc ent side (YOKOGAWA solution-based software package) is required in addition to the workbefore and after installation of Exaopc
cli-Perform the installation according to the description in this manual
ALSO For more information about the security models, refer to:
Exaopc Security Guide (IM 36J02A01-01E)
For more information about the work when setting a security model, refer to:
• “l For Standard Model (Standalone Management)” on page 4-80
• “l For Standard Model (Domain Management)” on page 4-80
Trang 32The Exaopc R3.70 or later implements the user authentication mechanism at the time of cessing to an OPC server If, on accessing to any OPC data, the user is not successful inuser authentication through the process of logon to the OPC server, the data access via theOPC server will be disabled.
ac-This Security performs user authentication according to the security function of CENTUM
Al-so, such a mechanism, that does not use “PROG”, which has been used as a user for Exaopc
on the CENTUM builder, will be supported Advance to product security settings after the stallation is completed
Trang 33in-4.1.5 Precautions for Installing Windows Operating
“EXA” are automatically created If the user name is mistakenly set as Exaopc needs to beinstalled again after deleting this EXA user account
l Administrator Password
When starting the Windows pre-installed General-purpose computer for the first time, it mayprompt for entering the administrator password In this case, a password for the administratormust be confirmed and entered If the password for the administrator is omitted, various ad-ministration hindrances may occur such as part of software packages may not be correctly in-stalled or operation log may not be properly saved
Trang 34Before installing the software for this product, you need to change the Windows settings onyour computer to the recommended settings.
This configuration should be performed on the computer where the Windows OS and its ice packs have been installed
Trang 35Follow these steps to configure the system performance setting:
1 Sign in as an administrative user
2 Open Control Panel
3 Select [System and Security] > [System] > [Advanced system settings]
The System Properties dialog box appears
4 Select the [Advanced] tab, and click [Settings] in the Performance section
The Performance Options dialog box appears
5 Click the [Visual Effects] tab and select [Let Windows choose what’s best for my er]
comput-6 Click [OK]
A custom size is recommended for setting the virtual memory Follow these steps:
1 Sign in as an administrative user
2 Open Control Panel
3 Select [System and Security] > [System] > [Advanced system settings]
The System Properties dialog box appears
4 Select the [Advanced] tab, and click [Settings] in the [Performance] section
The Performance Options dialog box appears
5 Select the [Advanced] tab, select [Programs] under [Adjust for best performance of] andthen, in the [Virtual Memory] area, click [Change]
The Virtual Memory dialog box appears
6 Clear the [Automatically manage paging file size for all drives] check box
7 Select [Custom size] and set the Initial size and the Maximum size to a value 1.5 timesthe main memory capacity
For example, set the custom size to 9216 MB if the main memory capacity is 6 GB, or
12288 MB if 8 GB
8 Click [Set] and then click [OK]
TIP After setting the virtual memory, a message box for restarting the computer to validate the virtual memory
may be displayed If displayed, follow the instruction of the dialog to restart the computer.
Trang 36n Power Options
This section describes how to configure the Power Options settings Some of the items in theexplanation may not be displayed on your computer, depending on the computer's hardwareconfiguration If not displayed, the function of that item is not available on your computer
1 Sign in as an administrative user
2 Open Control Panel
3 Select [Hardware and Sound] > [Power Options]
The Power Options window appears
4 Select [High performance] under Preferred plans, and click [Change plan settings] to theright of it
The Edit Plan Settings window appears
TIP If High performance does not appear under Preferred plans, click [Show additional plans] Select [High
per-formance] and then click [Change plan settings] to the right of it.
5 Click [Change advanced power settings]
The Power Options dialog box appears
TIP Some of the advanced setting items explained hereafter may not be displayed, depending on the computer
configuration If not displayed, the functions of such items are not available.
6 Under Hard disk, set the setting for Turn off hard disk after to [Never]
7 Configure the Sleep settings as follows:
• [Sleep after]: Never
• [Allow hybrid sleep]: Off
• [Hibernate after]: Never
• [Allow wake timers]: Disable
8 Set the setting for Power button action under Power buttons and lid to [Shut down]
9 Under Display, set the setting for Turn off display after to [Never]
10 Click [OK]
TIP Configure the UPS service settings after installing the software for this product.
You must turn off fast startup before installing the control bus driver or Vnet/IP open cation driver
communi-Follow these steps to turn off fast startup:
1 Sign in as an administrative user
2 Open the Control Panel
3 Select [Hardware and Sound] > [Power Options]
The Power Options window appears
4 In the left pane, click [Choose what the power button does]
The System Settings window appears
Trang 376 The [Turn on fast startup (recommended)] check box appears under [Shutdown settings].Clear the check box if it is selected.
TIP If the [Turn on fast startup (recommended)] check box does not appear, this setting is not required.
7 Click [Save changes]
8 Restart the computer
IMPORTANT
After turning off fast startup, you must restart the computer
The Windows Defender software detects and removes spy ware
It is recommended to turn off this function because it is not used with this product
In a domain environment, turn off Windows Defender on domain member PCs at a time bymeans of a domain management operation such as Group Policies
In a workgroup environment, turn off Windows Defender by using the Local Group Policy tor
Edi-l Turning Off Windows Defender in Local Group Policy Editor
Follow these steps to turn off Windows Defender:
1 Sign in as an administrative user
2 Open Command Prompt
3 Enter gpedit.msc
Local Group Policy Editor appears
4 In the left pane, select [Computer Configuration] > [Administrative Templates] > [WindowsComponents] > [Windows Defender]
5 In the right pane, double-click [Turn off Windows Defender]
The Turn off Windows Defender dialog box appears
6 Select [Enabled] and click [OK]
Windows Update is a feature that updates Windows
In this product, you must disable Windows Update for the following reasons:
• With Windows Update enabled, it takes longer time to install the software for this product
• Components running the software for this product are expected to run continuously, butthe computer will restart automatically when Windows Update is enabled
TIP To use Windows Server Update Service (WSUS), install the software for this product first, manually enable
Windows automatic updates, and then set the WSUS.
Follow these steps to disable Windows Update:
1 Sign in as an administrative user
2 Open the Command Prompt
Trang 384 In the left pane, select [Computer Configuration] > [Administrative Templates] > [WindowsComponents] > [Windows Update].
5 In the right pane, double-click [Configure Automatic Updates]
The Configure Automatic Updates dialog box appears
6 Select [Disabled] and click [OK]
The Defragmenter Tool can be used to reorganize the fragmented files on computer hard disk
so as to improve the computer performance Since the performance of this product may beaffected when defragmenter is running, it is recommended to disable the schedule of the peri-odic disk defragmentation
Moreover, you may manually start the disk defragmenter when you feel the disk performance
is getting worse or when you perform system maintenance
1 Sign in as an administrative user
2 Open Control Panel
3 Select [System and Security] > [Administrative Tools] > [Defragment and Optimize
Drives]
The Optimize Drives window appears
4 Click [Change settings]
The Optimize Drives dialog box appears
5 Clear the [Run on a schedule (recommended)] check box and click [OK]
Figure 4.2.1-1 Optimize Drives dialog box
If you are using Windows 10, you must enable NET Framework 3.5.1 as it is disabled by fault Follow these steps to enable NET Framework 3.5.1 by using the Windows 10 installa-tion medium:
de-1 Sign in as an administrative user
2 Insert the Windows 10 installation medium into the drive
3 Right click on the Command Prompt, select [Run as Administrator]
Trang 39dism /online /enable-feature /featurename:NetFX3 /all /Source:<DVDDrive>:\sources\sxs\ /limitaccess
5 Confirm that the message, "The operation completed successfully." appears
6 Follow these steps to confirm that NET Framework 3.5.1 has been enabled:
a Open Control Panel
b Select [Programs] > [Programs and Features]
The Programs and Features window appears
c In the left pane, click [Turn Windows features on or off]
The Windows Features dialog box appears
d Confirm that a black square is shown in the [.NET Framework 3.5 (including NET 2.0and 3.0)] check box
Figure 4.2.1-2 Windows Features dialog box
In installation of Exaopc the time synchronization with Internet server options disabled Please
do not change the setting
The TCP/IP Inconsistency Detect Tool should be used while performing the installation Wheninconsistency is found, TCP/IP Inconsistency Repair Tool should be used to repair the set-tings
SEE
ALSO For more information about the TCP/IP Inconsistency Detect Tool and TCP/IP Inconsistency Repair Tool, fer to:
re-• 7.1.1, “TCP/IP Inconsistency Detect Tool” on page 7-10
• 7.1.2, “TCP/IP Inconsistency Repair Tool” on page 7-12
Trang 40Follow these procedures when you use a Windows 7 computer.
Ensure that the file system is in the NTFS format If the partition of the operating system isalready formatted in FAT, reinstall the operating system to reformat it into NTFS Partitions notinstalled with OS should also be formatted into NTFS
Follow these steps to configure the system performance setting:
1 Log on as an administrative user
2 Open Control Panel
3 Select [System and Security] > [System] > [Advanced system settings]
The System Properties dialog box appears
4 Select the [Advanced] tab, and click [Settings] in the Performance section
The Performance Options dialog box appears
5 Click the [Visual Effects] tab and select [Let Windows choose what’s best for my er]
comput-Figure 4.2.2-1 Performance Options Dialog Box (Visual Effects Tab)
6 Click [OK]