Trang 1

Material Safety Data Sheet PRODUCT NAME PAGE

( 1 /8) MAGNETIC PARTICLE SPRAY SM-15

SECTION 1 CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Identity (Trade Name As Used On Label); MAGNETIC PARTICLE SPRAY SM-15

Recommended use of the chemical and restrictions on use; Black Magnetic Particle Spray

Manufacturer Name /Address:

NAMBANG CNA CO., LTD /392-3 Chupal-ri, Paengsung-Eup, Pyongtaek-si, Kyonggi-do,

KOREA 451-805 TEL: 8231 651 5911-8 FAX: 8231 691 6441 /8231 6586441 Date Prepared; Nov 19 2010

SECTION 2 HAZARD IDENTIFICATION

Hazard Class

Hazard Class Hazard category

Specific target organ toxicity(Single exposure) 3(Narcotic effects)

GHS label elements, including precautionary statements

Signal word Danger

- Extremely flam m able aerosol

Hazard statement - Flammable liquid and vapour

- May cause drowsiness or dizziness

- Keep away from heat/sparks/open flames/hot surfaces.-No smoking

- Do not spray on an open flame or other ignition source

- Pressurized container: Do not pierce or burn, even after use

- Keep container tightly closed

Prevention - Ground/Bond container and receiving equipment.

Precautionary - Use explosion-proof electrical/ventilating/lighting/ /equiprn ent. statements - Use only non-sparking tools.

- Take precautionary measures against static discharge

- Wear protective gloves/eye protection/face protection

- Avoid breathing dustlfume/gas/mist/vapours/spray

- Use only outdoors or in a well-ventilated area

Response - IF ON SKIN (or hair): Remove/Take off immediately all contaminated

Trang 2

PRODUCT NAME MAGNETIC PARTICLE SPRAY SM-15 ( 2 / 8 )

clothing Rinse skin with water/shower

- In case of fire: Use for extinction

- IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing

- Call a POISON CENTER or doctor/physician if you feel unwell

- Protect from sunlight Do not expose to temperatures exceeding Storage 50 'C/122 QF.

- Store locked up

- Store in a well-ventilated place Keep container tightly closed

- Dispose of contents/container to "'in accordance with local/ Disposal

regional/national/international regulations(to be specified)

Other hazards which do not result in classification

In

SECTION 3 COMPOSITION/INFORMATION ON INGREDIENTS

-Hydrotreated light distillate 64742-47-8 >49

-SECTION 4 FIRST AID PROCEDURES

Eye contact; Immediately flush eyes with plenty of water for at least 15 minutes Remove contact lenses,

if present and easy to do Continue rinsing Get medical attention if irritation develops and persists Skin contact; Immediately flush skin with plenty of water Get medical attention if irritation develops and persists For minor skin contact, avoid spreading material on unaffected skin Wash clothing separately before reuse Take off immediately all contaminated clothing

Inhalation; Move to fresh air Oxygen or artificial respiration if needed Call a physician if symptoms develop or persist

Trang 3

PRODUCT NAME MAGNETIC PARTICLE SPRAY SM-15

PAGE

( 3 / 8 )

Ingestion: Immediately call a POISON CENTER or doctor/physician Never give anything by mouth to a victim who is unconscious or is having convulsions Do not induce vomiting without advice from poison control center Do not use mouth-to-mouth method if victim ingested the substance Induce artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device Rinse mouth thoroughly If vomiting occurs, keep head low so that stomach content doesn't get into the lungs

SECTION 5 FIRE-FIGHTING MEASURES

Suitable extinguishing media: Use water spray to keep fire exposed containers cool If substance does ignite, use C02, dry chemical or foam

Specific hazards arising from the chemical: No information found

Special protective equipment and precautions for fire fighters: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other positive pressure mode Combustion by-products include phosgene and hydrogen chloride gases Structural firefighters' clothing provides only lim ited protection to the com bustion products of this material

SECTION 6 ACCIDENTAL RELEASE MEASURES

Personal precautions: Ensure adequate ventilation Keep unnecessary personnel away Keep out of low areas Keep people away from and upwind of spill/leak Ventilate closed spaces before entering them Do not touch damaged containers or spilled material unless wearing appropriate protective clothing Wear appropriate protective equipment and clothing during clean-up

Environmental precautions: Do not contaminate water

Methods for containment: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area) Dike the spilled material, where this is possible Prevent entry into waterways, sewer, basements or confined areas Use water spray to reduce vapors or divert vapor cloud drift

Methods for cleaning up:

- Large Spills: Dike far ahead of spill for later disposal Use a non-combustible material like vermiculite, sand or earth to soak up the product and place into a container for later disposal Use only non-sparking tools

- Small Spills: Wipe up with absorbent material (e.g cloth, fleece)

SECTION 7 HANDLING AND STORAGE

Trang 4

PRODUCT NAME MAGNETIC PARTICLE SPRAY SM-15 ( 4 / 8 )

Handling; Vapors may form explosive mixtures with air Do not smoke Take precautionary measures against static discharges All equipment used when handling the product must be grounded Use only in area provided with appropriate exhaust ventilation Wear personal protective equipment Avoid prolonged exposure Wash thoroughly after handling DO NOT handle, store or open near an open flame, sources of heat or sources of ignition Protect material from direct sunlight Use non-sparking tools and explosion-proof equipment

Storage; Store in cool place Store in a well-ventilated place Keep container tightly closed Keep away from heat, sparks and open flame Outside or detached storage preferred The pressure in sealed containers can increase under the influence of heat This material can accumulate static charge which may cause spark and become an ignition source Prevent electrostatic charge build-up by using common bonding and grounding techniques Keep in an area equipped with sprinklers Keep out of the reach of children Keep from contact with oxidizing materials

SECTION 8 EXPOSURE CONTROLS / PERSONAL PROTECTION

Airborne Exposure Limits;

Hydrotreated light distillate

TWA: 5 mg/m'

STEL: 10 mg/m'

Propane

1000 ppm (1800 mg/m') OSHA TWA

2500 ppm ACGIH TWA

Butane: TWA: 800 ppm (1900 mq/m')

Engineering controls; A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details

Personal protective equipment;

- Eye / face protection; Chemical goggles are recommended Face-shield Provide eyewash station and safety shower

- Skin protection; Wear chemical protective equipment that is specifically recommended by the manufacturer It may provide little or no thermal protection Wear protective gloves

Trang 5

PRODUCT NAME MAGNETIC PARTICLE SPRAY SM-15

PAGE l

(5/8) I

- Respiratory protection; Wear positive pressure self-contained breathing apparatus (SCBA) When workers are facing concentrations above the exposure limit they must use appropriate certified respirators

SECTION 9 PHYSICAL / CHEMICAL CHARACTERISTICS

Appearance; Black particle suspension

Odor; Mild hydrocarbon odor

Odour threshold; No information found

Ph; No information found

Melting point/freezing point; No information found

Initial boiling point and boiling range; No information found

Flash point; -105°C (Propane)

Evaporation rate; No information found

Flammability (solid, gas); No information found

Upper/lower flammability or explosive limits; No information found

Vapour pressure; No information found

Vapour density; No information found

Specific Gravity (H20= 1); 0.78 ± 0.05

Relative density; No information found

Solubility(ies); Insoluble

Partition coefficient; n-octanol/water: No inform ation found

Auto-ignition temperature; No information found

Decomposition temperature; No information found

Viscosity; No information found

Molecular Weight; No information found

SECTION 10 STABILITY AND REACTIVITY

STABILITY; Stable under ordinary conditions of use and storage

Hazardous Polymerization; Will not occur

Conditions to Avoid; Heat, flames and sparks Incompatible materials

Incompatability (Materials to Avoid); Strong oxidizing agents

Hazardous Decomposition Products; carbon oxide

Trang 6

MAGNETIC PARTICLE SPRAY SM-15

PAGE

( 6 / 8 )

SECTION 11 TOXICOLOGICAL INFORMATION

Magnetic particle

-Acute toxicity

- Oral; No information found

- Dermal; No information found

- Inhalation; No information found

Skin corrosion/irritation; No information found

Serious eye damage/irritation; No information found

Respiratory or skin sensitization; No information found

Germ cell mutagenicity; No information found

Carcinogenicity; No information found

Reproductive toxicity; No information found

Specific target organ toxicity (single exposure); No information found

Specific target organ toxicity (repeated exposure); No information found

Aspiration hazard; No information found

Hydrotreated light distillate

-Acute toxicity

- Oral; LD50 >5000 mg/kg (rat)

- Dermal; LD50 2000 mg/kg (rabbit)

- Inhalation; LC50 5.2 mg/I/4hr (rat)

Skin corrosion/irritation; No information found

Serious eye damage/irritation; No information found

Respiratory or skin sensitization; No information found

Germ cell mutagenicity; No information found

Carcinogenicity; No information found

Reproductive toxicity; No information found

Specific target organ toxicity (single exposure); No information found

Specific target organ toxicity (repeated exposure); No information found

Aspiration hazard; No information found

-

Propane-Acute toxicity

- Oral; No information found

- Dermal; No information found

- Inhalation; LD50 570000 ppm /15min (rat)

Trang 7

PRODUCT NAME MAGNETIC PARTICLE SPRAY SM-15

PAGE

(7 /8 )

Skin corrosion/irritation; No information found

Serious eye damage/irritation; No information found

Respiratory or skin sensitization; No inform ation found

Germ cell mutagenicity; No information found

Carcinogenicity; No information found

Reproductive toxicity; No information found

Specific target organ toxicity (single exposure); No information found

Specific target organ toxicity (repeated exposure); No information found

Aspiration hazard; No information found

-

Butane-Acute toxicity

- Oral; No information found

- Dermal; No information found

- Inhalation; LC50 277374 ppm /4hr (rat)

Skin corrosion/irritation; No inform ation found

Serious eye damage/irritation; No information found

Respiratory or skin sensitization; No information found

Germ cell mutagenicity; No information found

Carcinogenicity; No information found

Reproductive toxicity; No information found

Specific target organ toxicity (single exposure); No information found

Specific target organ toxicity (repeated exposure); No information found

Aspiration hazard; No information found

Toxicity; No information found

Persistence and degradability; No information found

Bioaccumulative potential; No information found

Mobility in soil; No information found

Other adverse effects; No information found

Trang 8

PRODUCT NAME

MAGNETIC PARTICLE SPRAY SM-15

PAGE I

(8/8) ,

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility Processing, use or contamination of this product may change the waste management options State and local disposal regulations may differ from federal disposal regulations Dispose of container and unused contents in accordance with federal, state and local requirements

SECTION 14 TRANSPORT INFORMATION

Proper Shipping Name; Aerosol

Class No 2

SECTION 15 REGULATORY INFORMATION

Follow all regulation in your country

SECTION 16 OTHER INFORMATION

This information has been faithfully prepared on the basis of various knowledge and information and is not

to guarantee the quality of this product Also, this information can be changed without prior notice in accordance with introduction of new knowledge and test results, etc For inquiries, please contact us or the place of product purchase