1. Trang chủ
  2. » Ngoại Ngữ

Electrical principles crossword

1 62 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 1
Dung lượng 101,16 KB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

The _____ side of a transformer has voltage induced to it.. The primary _____ of a transformer has voltage applied to it.. The motor configuration named Capacitor Start Capacitor Run is

Trang 1

1

2 3 4 5    

6      

  7      

     

8 9 10 11      

12      

      13      

14 15    

16 17    

        18

    19      

  20 21 22      

23 24

25 26 27 28        

  29 30      

      31      

32 33 34      

  35      

36      

37 38 39      

40      

41 42 43    

        Across

3 An open  _ will close at 115 degrees Fahrenheit

5 If more current flows thru a wire than it's rated for it will become

_ to the touch

6 Electricity can be changed to heat, light,  _, or magnetism

7 The  _ side of a transformer has voltage induced to it

8 A sine wave is a graphic plot of one  _ of AC voltage

11 The primary  _ of a transformer has voltage applied to it

12 A circuit can have as many  _ as needed

13 Run capacitors will come in a metal or  _ plastic container

16 _ flow in a conductor will create heat

17 The motor configuration named Capacitor Start Capacitor Run is

abbreviated  _ 

19 An ungrounded  _ is a name for a hot wire

22 Resistance is the  _ to current flow

25 Sometimes a capacitor is simply called a  _ 

27 In a heat pump the only electrical difference between heating and

cooling is the  _ 

31 The

32 A circuit needs a power source, a  _ , and a load to work

34 On an analog ohmmeter every time you change the scale you

must  _ the meter

35 A  _ means

36 Current is measured in  _ 

37 Some run capacitors may have a painted  _ to mark the side

that should be connected to the fused line

39 _ is a name for switch

40 A line or  _ diagram will show us physical wiring

connections

41 Transformers are rated in  _ 

42 When we replace a relay we need to know the coil voltage and the

switch  _ and amp rating

Down

1 In a heat pump defrost cycle, it will take a combination of temperature and _ to initiate defrost

2 A mechanical switch is controlled automatically by outside  _ like temperature or pressure & etc

4 The main winding in a single phase motor is called the  _ winding

5 An RVS can be energized in  _ or cooling

7 The most useful wiring diagram to us is the Ladder  _ 

9 A run cap may be filled with  _ to dissipate heat

10 The secondary side of a transformer has voltage  _ into it

14 Used to protect wires

15 When using an ohmmeter the first step is to kill the power, the  _ step is

to isolate the component

18 Ground wires should be run  _ with no switches or fuses in line

20 A  _ is a graphic plot of one cycle of AC voltage

21 _ voltage drops are caused by dirty contacts, loose wires, and frayed wires

23 The abbreviation for a run capacitor

24 277v power is mainly used for  _ lights

26 A Heat  _ will always have an RVS

28 If voltage output of a transformer is less than the input, it is called a  _ down transformer

29 We should expect to  _ a reading from 215 volts to 250 volts on what we now call a 240:120VAC 1 phase power source

30 EMF is measured in  _ 

31 The main job of capacitors is to increase starting  _ 

33 The main enemy of all electrical devices is  _ 

38 A delta transformer will have a conductor called a wild  _ 

40 Ohm's  _ states, E = I x R

43 FLA can be found on the motors  _ plate

 

Ngày đăng: 25/08/2016, 16:11

TỪ KHÓA LIÊN QUAN

w